• Title/Summary/Keyword: in-circuit test

Search Result 1,629, Processing Time 0.025 seconds

Investigation of the Estimation of Time-Varying Voltage Sags Considering the Short Circuit Contributions of Rotating Machines (회전기의 기여에 의한 시변성의 순간전압강하 예측에 관한 연구)

  • Yun Sang-Yun
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.6
    • /
    • pp.315-322
    • /
    • 2005
  • In this article, 1 would like to explore the estimation method of time-varying voltage sags in large industrial systems considering the short circuit contributions of rotating machines. For the power distribution system of KEPCO(Korea Electric Power Corporation), the magnitude of initial symmetrical short circuit current is generally not changed. However, in industrial systems which contain a number of rotating machines, the magnitude of voltage sag is generally changed from the initial to the clearing time of a fault due to the decreasing contribution of rotating machines for a fault current. The time-varying characteristics of voltage sags can be calculated using a short circuit analysis that is considered the time-varying fault currents. For this, the prediction formulations of time-varying voltage sags are proposed using a foreign standard. The proposed method contains the consideration of generator and motor effects. For the test of proposed formulations, a simple system of industrial consumer is used for the comparison conventional and proposed estimation method of voltage sag characteristics.

Analysis on the Mass Loss in Self-blast type $SF_6$ Gas Circuit Breaker (Self-blast형 $SF_6$ 가스 차단기의 노즐용삭 분석)

  • Jeong, Young-Woo;Bae, C.Y.;Ahn, H.S.;Choi, J.W.;Oh, I.S.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1422-1423
    • /
    • 2006
  • In our study, the PTFE nozzle ablation in the high-voltage self-blast type $SF_6$ gas circuit breaker was investigated. The test circuit breaker has the structure that the pin electrode is moving and the pressure reservoir volume and the dimension is almost same as commercial 145kv 40kA circuit breaker for similar result in real circuit breaker. The variation of current and arcing time was the range of $36kA_{rms}$(symmetry) - $40kA_{rms}$(asymmetry) and 10-16 ms. From the measured data the tendecy of the mass loss of the nozzle to current load and arc energy was estimated. In this process, the distance from the arc to nozzle(PTFE) surface, area which was exposed to arc and stroke contour was considered. These results will be used to enhance the accuracy of the computational fluid dynamics analysis in circuit breaker and estimate the residual life time of a circuit breaker.

  • PDF

Electromagnetic energy harvesting from structural vibrations during earthquakes

  • Shen, Wenai;Zhu, Songye;Zhu, Hongping;Xu, You-lin
    • Smart Structures and Systems
    • /
    • v.18 no.3
    • /
    • pp.449-470
    • /
    • 2016
  • Energy harvesting is an emerging technique that extracts energy from surrounding environments to power low-power devices. For example, it can potentially provide sustainable energy for wireless sensing networks (WSNs) or structural control systems in civil engineering applications. This paper presents a comprehensive study on harvesting energy from earthquake-induced structural vibrations, which is typically of low frequency, to power WSNs. A macroscale pendulum-type electromagnetic harvester (MPEH) is proposed, analyzed and experimentally validated. The presented predictive model describes output power dependence with mass, efficiency and the power spectral density of base acceleration, providing a simple tool to estimate harvested energy. A series of shaking table tests in which a single-storey steel frame model equipped with a MPEH has been carried out under earthquake excitations. Three types of energy harvesting circuits, namely, a resistor circuit, a standard energy harvesting circuit (SEHC) and a voltage-mode controlled buck-boost converter were used for comparative study. In ideal cases, i.e., resistor circuit cases, the maximum electric energy of 8.72 J was harvested with the efficiency of 35.3%. In practical cases, the maximum electric energy of 4.67 J was extracted via the buck-boost converter under the same conditions. The predictive model on output power and harvested energy has been validated by the test data.

Broadband Noise Reduction of Smart Panels using Piezoelectric Shunt Circuits (압전션트 회로를 이용한 지능패널의 광대역 소음저감에 관한 연구)

  • 정영채;김재환;이중근;하성호
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.624-629
    • /
    • 2003
  • In this paper, broadband shunt technique for increasing transmission loss is experimentally investigated. Piezoelectric shunt damping is studied using resonant shunt circuit and negative capacitor shunt circuit. A resonant shunt circuit is implemented by using a resistor and inductor. Negative Capacitor shunt damping is similar in nature to resonant shunt damping techniques, as a single piezoelectric material is used to dampen multi-mode. Performance of both methods is experimentally studied for noise reduction. This is based upon SAE J1400 test method and a transmission loss measurement system is provided for it. This paper will present the test setup fer transmission loss measurement and the tuning procedure of shunt circuits. Finally the results of sound transmission tests will be shown.

  • PDF

Syndrome Testable Design for Large MOSPLA's (신드롬 테스트가 용이한 대규모 MOSPLA의 설계)

  • Seok Bung Han
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.24 no.3
    • /
    • pp.527-534
    • /
    • 1987
  • This paper proposes a new syndrome-testable design method for large MOSPLA's. In the conventional syndrome test method, the testing array circuit for testability is added but it has the defect that the circuit gives effect on the normal operation of the basic PLA circuit. Therefore, by adding the shift registers to the product lines of the basic MOSPLA's this defect is eliminated and the number of test patterns is decreased. In order to reduce the number of fault free syndromes to be predetermined, also, one output line, which is connected to all product lines is added. Therefore the number of output lines be observed is decreased. And the analytical method to compute fault free syndromes is presented. By unsing this method, the time and the effort to compute the syndromes are decreased.

  • PDF

A Study on the Expandable Bobbin Type Multiple Integrated Coupled-Inductor Applied 4-Pralleled Switching Rectifier (보빈 적층 방식의 다중 공유결합 인덕터를 이용한 4병렬 스위칭 정류기에 관한 연구)

  • Yoo, Jeong Sang;Ahn, Tae Young
    • Journal of the Semiconductor & Display Technology
    • /
    • v.18 no.4
    • /
    • pp.18-24
    • /
    • 2019
  • In this paper, expandable bobbin type multiple integrated coupled-inductor applied 4-paralled switching rectifier was proposed. To design the proposed inductor easily, inductance designing formula was derived through magnetic circuit analysis of the 4-paralleled integrated coupled-inductor. Furthermore, to verify practicality of the proposed inductor, it was applied in 600W class 4-paralleled interleaved switching rectifier, and the steady-state characteristics of the proposed inductor and discrete inductors were compared. Consequently, it was showed that the proposed inductor can replace the conventional discrete inductors with alternative electrical characteristic standard, hence miniaturization of the SMPS can be achieved. From the test result, test circuit with the proposed inductor showed maximum 97.1% of power conversion efficiency and under 18W of power loss where the circuit with discrete inductors showed 96.7% and 20W respectively.

A Study on the Development of Controller which is used Electric Operating Cell(EOC) for Vacuum Circuit Breaker and the Controller Performance Certification Test (진공차단기용 전자식 보조접점 컨트롤러 개발 및 성능인증시험에 관한 연구)

  • Lee, Ki-Seon;Park, Jung-Cheul;Chu, Soon-Nam
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.64 no.3
    • /
    • pp.130-137
    • /
    • 2015
  • This study is about the controller development of the Electric Operating Cell(EOC) which will replace the Mechanical Operated Cell(MOC) of the vacuum circuit breaker which has been used in the power plant and the performance test for the developed controller. The controller developed through this study was manufactured considering the harsh installation environment and electrical condition of the power plant, and the controller performance certification test for confirming the product reliability was taken to know whether or not to withstand fully in various electrical and mechanical problems. Items for performance certification test were AC power frequency voltage withstand test, combined surge immunity test, 1 [MHz] oscillatory SWC test, fast transient SWC test, radiated electromagnetic interference test, vibration test. As a result, all tests has passed an examination without malfunction.

The Korean Elementary Students' Conceptions of the Simple Electric Circuit

  • Seo, Sang-Oh;Kwon, Jae-Sool
    • Journal of The Korean Association For Science Education
    • /
    • v.22 no.5
    • /
    • pp.944-956
    • /
    • 2002
  • The purpose of this study was to investigate students' conceptions of the simple electric circuit using a battery and a bulb. 19 fourth grade students from a rural elementary school in Korea participated in this study. Data on the children's understandings of electric circuit were collected through three sources; prediction tests, drawing tests and individual interviews. The prediction tests were paper and pencil tests composed of 10 problems, predicting whether bulbs in 10 simple circuit diagrams would light. For each prediction, the children were asked to provide a written explanation of their thinking. The drawing tests consisted of 6 problems. One was to draw the inside of the bulb base, and the others were to make the wire connections between a battery and a bulb in the diagrams, to light the bulb. The interviews were conducted with seven children who showed differing degrees of understanding. No student was aware of the wire connections inside the bulb base. Many students stated whether the bulb would light or not, according to the tip of the bulb contacting the positive battery terminal and an end of wire contacting the negative battery terminal. Most of them thought that the tip of the bulb should contact the positive battery terminal, so that the bulb would light. In short, students did not use a scientific conception of electric current to predict and explain the electric circuit.

Evaluation of IC Electromagnetic Conducted Immunity Test Methods Based on the Frequency Dependency of Noise Injection Path (Noise Injection Path의 주파수 특성을 고려한 IC의 전자파 전도내성 시험 방법에 관한 연구)

  • Kwak, SangKeun;Kim, SoYoung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.4
    • /
    • pp.436-447
    • /
    • 2013
  • In this paper, Integrated circuit(IC) electromagnetic(EM) conducted immunity measurement and simulation using bulk current injection(BCI) and direct power injection(DPI) methods were conducted for 1.8 V I/O buffers. Using the equivalent circuit models developed for IC electromagnetic conducted immunity tests, we investigated the reliability of the frequency region where IC electromagnetic conducted immunity test is performed. The insertion loss for the noise injection path obtained from the simulation indicates that using only one conducted immunity test method cannot provide reliable conducted immunity test for broadband noise. Based on the forward power results, we analyzed the actual amount of EM noise injected to IC. We propose a more reliable immunity test methods for broad band noise.

Improved Current Source using Full-Bridge Converter Type for Thyristor Valve Test of HVDC System (HVDC 시스템의 SCR 사이리스터 밸브 시험을 위한 Full-Bridge Converter 방식의 개선된 전류원 회로)

  • Jung, Jae-Hun;Cho, Han-Je;Goo, Beob-Jin;Nho, Eui-Cheol;Chung, Yong-Ho;Baek, Seung-Taek
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.4
    • /
    • pp.363-368
    • /
    • 2015
  • This paper deals with an improved current source using full-bridge converter type for thyristor valve test of HVDC system. The conventional high-current and low-voltage source of synthetic test circuit requires additional auxiliary power supply to provide the reverse voltage for the auxiliary thyristor valve during turn-off process. The proposed circuit diagram to provide the reverse voltage is extremely simple because no additional component is required. The reverse voltage can be obtained from the input DC voltage of the high-current and low-voltage power supply. The operation principle and design method of the proposed system are described. Simulation and experimental results in scaled down STC of 200 V, 30 A demonstrate the validity of the proposed scheme.