• Title/Summary/Keyword: in-circuit test

Search Result 1,629, Processing Time 0.027 seconds

The Design of Multi-channel Synchronous Communication IC Using FPGA (FPGA를 이용한 다채널 동기 통신용 IC 설계)

  • Yang, Oh;Ock, Seung-Kyu
    • Journal of the Semiconductor & Display Technology
    • /
    • v.10 no.3
    • /
    • pp.1-6
    • /
    • 2011
  • In this paper, the IC(Integrated Circuit) for multi-channel synchronous communication was designed by using FPGA and VHDL language. The existing chips for synchronous communication that has been used commercially are composed for one to two channels. Therefore, when communication system with three channels or more is made, the cost becomes high and it becomes complicated for communication system to be realized and also has very little buffer, load that is placed into Microprocessor increases heavily in case of high speed communication or transmission of high-capacity data. The designed IC was improved the function and performance of communication system and reduced costs by designing 8 synchronous communication channels with only one IC, and it has the size of transmitter/receiver buffer with 1024 bytes respectively and consequently high speed communication became possible. It was designed with a communication signal of a form various encoding. To detect errors of communications, the CRC-ITU-T logic and channel MUX logic was designed with hardware logics so that the malfunction can be prevented and errors can be detected more easily and input/output port regarding each communication channel can be used flexibly and consequently the reliability of system was improved. In order to show the performance of designed IC, the test was conducted successfully in Quartus simulation and experiment and the excellence was compared with the 85C3016VSC of ZILOG company that are used widely as chips for synchronous communication.

A Detection Method of Resistive Leakage Current Flowing through ZnO Arrester Blocks (산화아연 피뢰기소자에 흐르는 저항분 누설전류의 검출기법)

  • 이복희;강성만
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.3
    • /
    • pp.67-73
    • /
    • 2001
  • This paper resents a developed measuring device of resistive leakage current and a fundamental discussion of deterioration diagnosis for Zinc Oxide(ZnO) arrester blocks. We have developed the leakage current detection device for ageing test and durability evaluation for ZnO arrester blocks. The resistive leakage current can be used as an indicator to discriminate whether the ZnO arrester blocks is in good state or in bad. The resistive leakage current measuring system with the compensation circuit was designed and fabricated. The sauce tests for ZnO arrester blocks were investigated by observing the resistive leakage current together with fast Fourier transform analysis. The proposed monitoring systems for the resistive leakage current can effectively be used to investigate the electrophysical properties of ZnO arrester blocks in laboratory and to develop the techniques of forecasting the deterioration of ZnO arresters in electric power systems.

  • PDF

Development of Strain-gauge-type Rotational Tool Dynamometer and Verification of 3-axis Static Load (스트레인게이지 타입 회전형 공구동력계 개발과 3축 정적 하중 검증)

  • Lee, Dong-Seop;Kim, In-Su;Lee, Se-Han;Wang, Duck-Hyun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.9
    • /
    • pp.72-80
    • /
    • 2019
  • In this task, the tool dynamometer design and manufacture, and the Ansys S/W structural analysis program for tool attachment that satisfies the cutting force measurement requirements of the tool dynamometer system are used to determine the cutting force generated by metal cutting using 3-axis static structural analysis and the LabVIEW system. The cutting power in a cutting process using a milling tool for processing metals provides useful information for understanding the processing, optimization, tool status monitoring, and tool design. Thus, various methods of measuring cutting power have been proposed. The device consists of a strain-gauge-based sensor fitted to a new design force sensing element, which is then placed in a force reduction. The force-sensing element is designed as a symmetrical cross beam with four arms of a rectangular parallel line. Furthermore, data duplication is eliminated by the appropriate setting the strain gauge attachment position and the construction of a suitable Wheatstone full-bridge circuit. This device is intended for use with rotating spindles such as milling tools. Verification and machining tests were performed to determine the static and dynamic characteristics of the tool dynamometer. The verification tests were performed by analyzing the difference between strain data measured by weight and that derived by theoretical calculations. Processing test was performed by attaching a tool dynamometer to the MCT to analyze data generated by the measuring equipment during machining. To maintain high productivity and precision, the system monitors and suppresses process disturbances such as chatter vibration, imbalances, overload, collision, forced vibration due to tool failure, and excessive tool wear; additionally, a tool dynamometer with a high signal-to-noise ratio is provided.

Construction and basic performance test of an ICT-based irrigation monitoring system for rice cultivation in UAE desert soil

  • Mohammod, Ali;Md Nasim, Reza;Shafik, Kiraga;Md Nafiul, Islam;Milon, Chowdhury;Jae-Hyeok, Jeong;Sun-Ok, Chung
    • Korean Journal of Agricultural Science
    • /
    • v.48 no.4
    • /
    • pp.703-718
    • /
    • 2021
  • An irrigation monitoring system is an efficient approach to save water and to provide effective irrigation scheduling for rice cultivation in desert soils. This research aimed to design, fabricate, and evaluate the basic performance of an irrigation monitoring system based on information and communication technology (ICT) for rice cultivation under drip and micro-sprinkler irrigation in desert soils using a Raspberry Pi. A data acquisition system was installed and tested inside a rice cultivating net house at the United Arab Emirates University, Al-Foah, Al-Ain. The Raspberry Pi operating system was used to control the irrigation and to monitor the soil water content, ambient temperature, humidity, and light intensity inside the net house. Soil water content sensors were placed in the desert soil at depths of 10, 20, 30, 40, and 50 cm. A sensor-based automatic irrigation logic circuit was used to control the actuators and to manage the crop irrigation operations depending on the soil water content requirements. A developed webserver was used to store the sensor data and update the actuator status by communicating via the Pi-embedded Wi-Fi network. The maximum and minimum average soil water contents, ambient temperatures, humidity levels, and light intensity values were monitored as 33.91 ± 2 to 26.95 ± 1%, 45 ± 3 to 24 ± 3℃, 58 ± 2 to 50 ± 4%, and 7160-90 lx, respectively, during the experimental period. The ICT-based monitoring system ensured precise irrigation scheduling and better performance to provide an adequate water supply and information about the ambient environment.

Compact and Wideband Coupled-Line 3-dB Ring Hybrids (Coupled Line으로 구성된 작고 넓은 대역폭을 가지는 3-dB Ring Hybrids)

  • Ahn, Hee-Ran;Kim, Jung-Joon;Kim, Bum-Man
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.8
    • /
    • pp.862-877
    • /
    • 2008
  • In this paper, two types of wideband 3-dB ring hybrids are compared and discussed to show the ring hybrid with a set of coupled-line sections better. However, the better one still has a realization problem that perfect matching can be achieved only with -3 dB coupling power. To solve the problem, a set of coupled-line sections with two shorts is synthesized using one- and two-port equivalent circuits and design equations are derived to have perfect matching, regardless of the coupling power. Based on the design equations, a modified ${\Pi}-type$ of transmission-line equivalent circuit is newly suggested. It consists of coupled-line sections with two shorts and two open stubs and can be used to reduce a transmission-line section, especially when its electrical length is greater than ${\pi}$. Therefore, the $3\;{\lambda}/4$ transmission-line section of a conventional ring hybrid can be reduced to less than ${\pi}/2$. To verify the modified ${\Pi}-type$ of transmission- line equivalent circuit, two kinds of simulations are carried out; one is fixing the electrical length of the coupled-line sections and the other fixing its coupling coefficient. The simulation results show that the bandwidths of resulting small transmission lines are strongly dependent on the coupling power. Using modified and conventional ${\Pi}-types$ of transmission-line equivalent circuits, a small ring hybrid is built and named a compact wideband coupled-line ring hybrid, due to the fact that a set of coupled-line sections is included. One of compact ring hybrids is compared with a conventional ring hybrid and the compared results demonstrate that the bandwidth of a proposed compact ring hybrid is much wider, in spite of being more than three times smaller in size. To test the compact ring hybrids, a microstrip compact ring hybrid, whose total transmission-line length is $220^{\circ}$, is fabricated and measured. The measured power divisions($S_{21}$, $S_{41}$, $S_{23}$ and $S_{43}$) are -2.78 dB, -3.34 dB, -2.8 dB and -3.2 dB, respectively at a design center frequency of 2 GHz, matching and isolation less than -20 dB in more than 20 % fractional bandwidth.

Effect of Home Training on Male College Students Body Composition and Fitness (홈트레이닝이 남자 대학생의 신체 조성과 체력에 미치는 효과)

  • Han Jun Hee;Jae Hoon Lee;Ji Sun Kim;Yoo Sung Oh
    • Journal of the Korean Applied Science and Technology
    • /
    • v.41 no.2
    • /
    • pp.413-423
    • /
    • 2024
  • Sixteen male college students were divided into two groups: a face-to-face group(n=8) and a real-time non-face-to-face exercise group(n=8), engaging in 30minute sessions twice a week for a duration of 8 weeks. Body composition and physical strength were measured as dependent variables before and after the home training period. For data analysis, a two-way ANOVA with repeated measures was conducted to evaluate the effects on body composition and physical strength, considering differences in exercise methods and measurement periods. Post hoc analysis using Bonferroni correction was applied. To compare the mean difference in change between groups, the pre-post difference was calculated, and an independent t-test was performed. The statistical significance level was set at p<.05. The results showed that 8 weeks of home training led to an increase in skeletal muscle mass and improvements in muscle strength, muscular endurance, and cardiorespiratory endurance in male college students, regardless of whether they participated in face-to-face or real-time non-face-to-face exercise. Moreover, there was no significant difference in exercise effectiveness between the face-to-face and real-time non-face-to-face exercise methods. Thus, these findings suggest that real-time non-face-to-face exercise can be as effective as face-to-face exercise in enhancing skeletal muscles and physical strength in male college students. Additionally, if a real-time non-face-to-face exercise program is validated for individuals with mobility issues or the elderly, it could serve as an effective alternative for those who face challenges in participating in face-to-face exercise sessions.

Application of Adsorption Characteristic of Ferrous Iron Waste to Phosphate Removal from Municipal Wastewater (폐산화철의 흡착특성을 이용한 도시하수내 인 처리)

  • Kim, Jin-Hyung;Lim, Chae-Sung;Kim, Keum-Yong;Kim, Dae-Keun;Lee, Sang-Ill;Kim, Jong-Soo
    • Korean Journal of Environmental Agriculture
    • /
    • v.27 no.3
    • /
    • pp.231-238
    • /
    • 2008
  • This study proposed the method of phosphate recovery from municipal wastewater by using ferrous iron waste, generated from the mechanical process in the steel industry. In the analysis of XRD, ferrous iron waste was composed of $Fe_3O_4$ (magnetite), practically with $Fe^{2+}$ and $Fe^{3+}$. It had inverse spinel structure. In order to identify the adsorption characteristic of phosphate on ferrous iron waste, isotherm adsorption test was designed. Experimental results were well analyzed by Freundlich and Langmuir isotherm theories. Empirical constants of all isotherms applied increased with alkalinity in the samples, ranging from 1.2 to 235 $CaCO_3/L$. In the regeneration test, empirical constants of Langmuir isotherm, i.e., $q_{max}$ (maximum adsorption capacity) and b (energy of adsorption) decreased as the frequency of regeneration was increased. Experiment was further performed to evaluate the performance of the treatment scheme of chemical precipitation by ferrous iron waste followed by biological aerated filter (BAF). The overall removal efficiency in the system increased up to 80% and 90% for total phosphate (TP) and soluble phosphate (SP), respectively, and the corresponding effluent concentrations were detected below 2 mg/L and 1 mg/L for TP and SP, respectively. However, short-circuit problem was still unsolved operational consideration in this system. The practical concept applied in this study will give potential benefits in achieving environmentally sound wastewater treatment as well as environmentally compatible waste disposal in terms of closed substance cycle waste management.

Study on the Emergency Broadcasting System Using Ultrasonic Waves (초음파를 이용한 비상방송시스템에 관한 연구)

  • Baek, Dong-Hyun
    • Fire Science and Engineering
    • /
    • v.33 no.6
    • /
    • pp.186-189
    • /
    • 2019
  • NFSC 202 stipulates that if a loudspeaker or wiring on one floor of a building is shorted because of fire, it should not interfere with the fire notification on the other floors. To address this problem, this study proposes an ultrasonic transmitter/receiver consisting of an ADC, HPF, and LPF in an emergency broadcasting system that can operate regardless of the volume level of the amplifier output loudspeaker capacity. After transmitting the transmission frequency at -12 dB (110 kHz), it is received at -18 dB by transmitting -12 dB in case of short circuit depending on the frequency characteristics. Typically, depending on the loudspeaker capacity, it is received from -24 dB to -66 dB. In case of disconnection, it exceeds -66 dB and no data are received. It is also possible to check the track status during fire or general broadcasting. Thus, it was confirmed that the system is suitable for NFSC 202 regulations. Furthermore, as the current system is replaced, the inspection or test criteria should be amended or revised.

Electrochemical Impedance Study on the Rebar Corrosion in Cement Mortar Containing Chloride Ions (전기화학적 임피던스법을 이용한 염함유 시멘트 모르터내의 철근부식 연구)

  • Nam, Sang Cheal;Paik, Chi-Hum;Cho, Won Il;Cho, Byung Won;Yun, Kyung Suk;Chun, Hai Soo
    • Applied Chemistry for Engineering
    • /
    • v.9 no.6
    • /
    • pp.811-816
    • /
    • 1998
  • Rebar corrosion in cement mortar containing chloride ions was investigated by electrochemical AC impedance spectroscopy. Corrosion of mild steel bar was accelerated by an acceleration test equipment in short period. Impedance values obtained from AC-impedance method could be adapted to the proposed electrochemical equivalent circuit model and they were consistent with calculated values obtained by CNLS fitting method. The weight loss of rebar could be calculated by charge transfer resistance($R_2$) with time and it was close to real value.

  • PDF

Design and Implementation of the Hi인 Power Ka-band Waveguide Diplexer with an E-plane T-junction (고전력 전송이 가능한 Ka 대역 E-평면 T형 분기 도파관 다이플렉서의 설계 및 구현)

  • Yun So-Hyeun;Uhm Man-Seok;Yom In-Bok
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.7 s.98
    • /
    • pp.732-739
    • /
    • 2005
  • In this paper, the design and implementation of the Ka-band(20/30 GHz) waveguide diplexer with an E-plane T-junction are described. The waveguide diplexer consists of a transmit filter and a receive filter combined to the antenna port via an E-plane T-junction. The reason why the E-plane T-junction structure was selected is to reduce PIM(Passive Intermodulation) level as the split-plane is located in the low electrical current zone. The optimization was performed using the equivalent circuit so that the computation time might reduce. The structure of the diplexer was designed to handle high power and the multipaction analysis was performed. The multipaction margin was greater than 12 dB and satisfied with ESA/ESTEC recommendation. The manufactured diplexer shows minimum return loss of 22 dB, maximum insertion loss of 0.20 dB and maximum isolation of -40 dB for both transmitted receive bands. Those mean the analysis results of the waveguide diplexer were well agreed with the electrical performance test.