• Title/Summary/Keyword: in-circuit test

Search Result 1,629, Processing Time 0.029 seconds

Price-Based Quality-of-Service Control Framework for Two-Class Network Services

  • Kim, Whan-Seon
    • Journal of Communications and Networks
    • /
    • v.9 no.3
    • /
    • pp.319-329
    • /
    • 2007
  • This paper presents a price-based quality-of-service (QoS) control framework for two-class network services, in which circuit-switched and packet-switched services are defined as "premium service class" and "best-effort service class," respectively. Given the service model, a customer may decide to use the other class as a perfect or an imperfect substitute when he or she perceives the higher utility of the class. Given the framework, fixed-point problems are solved numerically to investigate how static pricing can be used to control the demand and the QoS of each class. The rationale behind this is as follows: For a network service provider to determine the optimal prices that maximize its total revenue, the interactions between the QoS-dependent demand and the demand-dependent QoS should be thoroughly analyzed. To test the robustness of the proposed model, simulations were performed with gradually increasing customer demands or network workloads. The simulation results show that even with substantial demands or workloads, self-adjustment mechanism of the model works and it is feasible to obtain fixed points in equilibrium. This paper also presents a numerical example of guaranteeing the QoS statistically in the short term-that is, through the implementation of pricing strategies.

Design of LED Lighting System using Bluetooth Wireless Communcation (Bluetooth 무선 통신 기능을 이용한 LED 조명시스템 설계)

  • Kim, Hye Myeong;Yang, Woo Seok;Cho, Young Seek;Park, Dae Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.2
    • /
    • pp.1-7
    • /
    • 2015
  • The Light Emitting Diode(LED) lighting control system proposed in this thesis is made up of a sensor module, a microcontroller, Bluetooth wireless communication, LED Driver, and LED downlight. The sensor module, comprised of an infrared sensor, an illumination sensor, and a temperature sensor, was designed to one Printed Circuit board(PCB). The system is able to identify the environment information collected by the sensor, and make it possible to control lighting automatically and manually through sensors. In addition, depending on users' conditions, a color temperature can be controlled. CS-1000, a spectroradiometer, was employed to measure the changing values of a color temperature in 8 steps. According to a test, it was found that it was possible to change a color temperature from 3187K of Warm White LED to 5598K of Cool White LED. The Bluetooth based wireless communication technique makes it possible to control more lighting devices than other wireless communication techniques does.

Analysis of Output Characteristics of High-Power Shingled Photovoltaic Module due to Temperature Reduction (고출력 슁글드 태양광 모듈의 온도 저감에 따른 출력 특성 분석)

  • Bae, Jae Sung;Yoo, Jang Won;Jee, Hong Sub;Lee, Jae Hyeong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.33 no.6
    • /
    • pp.439-444
    • /
    • 2020
  • An increase in the temperature of photovoltaic (PV) modules causes reduced power output and shorter lifetime. Because of these characteristics, demands for the heat dissipation of PV modules are increasing. In this study, we attached a heat dissipation sheet to the back sheet of a shingled PV module and observed the temperature changes. The PV shingled module was tested under Standard Test Conditions (STCs; irradiance: 1,000 W/㎡, temperature: 25℃, air mass: 1.5) using a solar radiation tester, wherein the temperature of the PV module was measured by irradiating light for a certain duration. As a result, the temperature of the PV module with the heat dissipation sheet decreased by 3℃ compared to that without a heat dissipation sheet. This indicated that the power loss was caused by a temperature increase of the PV module. In addition, it was confirmed that the primary parameter contributing to the reduced PV module output power was the open circuit voltage (Voc).

An Efficient Hardware Implementation of AES Rijndael Block Cipher Algorithm (AES Rijndael 블록 암호 알고리듬의 효율적인 하드웨어 구현)

  • 안하기;신경욱
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.12 no.2
    • /
    • pp.53-64
    • /
    • 2002
  • This paper describes a design of cryptographic processor that implements the AES (Advanced Encryption Standard) block cipher algorithm, "Rijndael". An iterative looping architecture using a single round block is adopted to minimize the hardware required. To achieve high throughput rate, a sub-pipeline stage is added by dividing the round function into two blocks, resulting that the second half of current round function and the first half of next round function are being simultaneously operated. The round block is implemented using 32-bit data path, so each sub-pipeline stage is executed for four clock cycles. The S-box, which is the dominant element of the round block in terms of required hardware resources, is designed using arithmetic circuit computing multiplicative inverse in GF($2^8$) rather than look-up table method, so that encryption and decryption can share the S-boxes. The round keys are generated by on-the-fly key scheduler. The crypto-processor designed in Verilog-HDL and synthesized using 0.25-$\mu\textrm{m}$ CMOS cell library consists of about 23,000 gates. Simulation results show that the critical path delay is about 8-ns and it can operate up to 120-MHz clock Sequency at 2.5-V supply. The designed core was verified using Xilinx FPGA board and test system.

AN ELECTROCHEMICAL STUDY ON THE CORROSION RESISTANCE OF THE VARIOUS IMPLANT METALS (수종 임플랜트 금속의 내식성에 관한 전기화학적 연구)

  • Jeon Jin-Young;Kim Yung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.3
    • /
    • pp.423-446
    • /
    • 1993
  • Titanium and its alloys are finding increasing use in medical devices and dental implants. The strong selling point of titanium is its resistance to the highly corrosive body fluids in which an implant must survive. This corrosion resistance is due to a tenacious passive oxide or film which exists on the metal's surface and renders it passive. Potentiodynamic polarization measurement is one of the most commonly used electro-chemical methods that have been applied to measure corrosion rates. And the potentiodynamic polarization test supplies detailed information such as open circuit, rupture, and passivation potential. Furthermore, it indicates the passive range and sensitivity to pitting corrosion. This study was designed to compare the corrosion resistance of the commonly used dental implant materials such as CP Ti, Ti-6A1-4V, Co-Cr-Mo alloy, and 316L stainless steel. And the effects of galvanic couples between titanium and the dental alloys were assessed for their useful-ness-as. materials for superstructure. The working electrode is the specimen , the reference electrode is a saturated calomel electrode (SCE), and the counter electrode is made of carbon. In $N_2-saturated$ 0.9% NaCl solutions, the potential scanning was performed starting from -800mV (SCE) and the scan rate was 1 mV/sec. At least three different polarization measurements were carried out for each material on separate specimen. The galvanic corrosion measurements were conducted in the zero-shunt ammeter with an implant supraconstruction surface ratio of 1:1. The contact current density was recorded over a 24-hour period. The results were as follows : 1. In potential-time curve, all specimens became increasingly more noble after immersion in the test solution and reached between -70mV and 50mV (SCE) respectively after 12 hours. 2. The Ti and Ti alloy in the saline solution were most resistant to corrosion. They showed the typical passive behavior which was exhibited over the entire experimental range. Therefore no breakdown potentials were observed. 3. Comparing the rupture potentials, Ti and Ti alloy had the high(:st value (because their break-down potentials were not observed in this study potential range ) followed by Co-Cr-Mo alloy and stainless steel (316L). So , the corrosion resistance of titanium was cecellent, Co-Cr-Mo alloy slightly inferior and stainless steel (316L) much less. 4. The contact current density sinks faster than any other galvanic couple in the case of Ti/gold alloy. 5. Ag-Pd alloy coupled with Ti yielded high current density in the early stage. Furthermore, Ti became anodic. 6. Ti/Ni-Cr alloy showed a relatively high galvanic current and a tendency to increase.

  • PDF

Design of an eFuse OTP Memory of 8 Bits for PMICs and its Measurement (PMIC용 8비트 eFuse OTP Memory 설계 및 측정)

  • Park, Young-Bae;Choi, In-Hwa;Lee, Dong-Hoon;Jin, Liyan;Jang, Ji-Hye;Ha, Pan-Bong;Kim, Young-Hee
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.05a
    • /
    • pp.722-725
    • /
    • 2012
  • In this paper, we design an 8-bit eSuse OTP (one-time programmable) memory based on a $0.35{\mu}m$ BCD process using differential paired eFuse cells which can sense BL data without a reference voltage and also have smaller sensing resistances of programmed eFuse links. The channel widths of a program transistor of the differential eFuse OTP cell are splitted into $45{\mu}m$ and $120{\mu}m$. Also, we implement a sensing margin test circuit with variable pull-up loads in consideration of variations of the programmed eFuse resistances. It is confirmed by measurement results that the designed 8-bit eFuse OTP memory IP gives a better yield when the channel width is $120{\mu}m$.

  • PDF

Corrosion mitigation of photovoltaic ribbon using a sacrificial anode (희생양극을 이용한 태양광 리본의 부식 저감)

  • Oh, Wonwook;Chan, Sung-Il
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.3
    • /
    • pp.681-686
    • /
    • 2017
  • Degradation is commonly observed in field-aged PV modules due to corrosion of the photovoltaic ribbon. The reduced performance is caused by a loss of fill factor due to the high series resistance in the PV ribbon. This study aimed to mitigate the degradation by corrosion using five sacrificial anodes - Al, Zn and their alloys - to identify the most effective material to mitigate the corrosion of the PV ribbon. The corrosion behavior of the five sacrificial anode materials were examined by open circuit potential measurements, potentiodynamic polarization tests, and galvanic current density and potential measurements using a zero resistance ammeter. Immersion tests for 120 hours were also conducted using materials and damp heat test tests were performed for 1500 hours using 4 cell mini modules. The Al-3Mg and Al-3Zn-1Mg sacrificial anodes had a low corrosion rate and reduced drop in power, making then suitable for long-term use.

Development And Application of Three-phase Inverter Output Wave Generator based on SPWM Control to Verify the Performance of LCL filters (LCL 필터의 성능 검증을 위한 SPWM 제어기반의 3상 인버터 출력 파형 발생 장치 개발 및 적용 연구)

  • Im, Dong-Kyun;Kang, Chang-Kyun;Ha, Won-Jin;Sandagdorj, Chuluunbaatar;Ko, Yun-Seok
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.5
    • /
    • pp.841-852
    • /
    • 2022
  • In this paper, a 3-phase inverter output waveform generator based on SPWM control was developed to verify the performance of the LCL filter. In order to obtain a test signal for verifying the performance of the filter, first, a DSP-based 3-phase SPWM signal generation algorithm was developed, and then a three-phase voltage source inverter circuit was designed using three half-bridge gate drivers. Next, one LCL filter was experimentally fabricated to verify the effectiveness of the developed SPWM-based 3-phase inverter output waveform generator as a test signal generator, and a DSP-based performance verification system was experimentally constructed. Finally, by comparing the three-phase voltage waveform before and after the LCL filter obtained in the output control experiment with the given time ratio, the effectiveness of the SPWM-based 3-phase inverter output waveform generator was verified.

Corrosion resistance assessment of nickel-titanium endodontic files with and without heat treatment

  • Tatiana Dias Costa;Elison da Fonseca e Silva;Paula Liparini Caetano ;Marcio Jose da Silva Campos ;Leandro Marques Resende ;Andre Guimaraes Machado;Antonio Marcio Resende do, Carmo
    • Restorative Dentistry and Endodontics
    • /
    • v.46 no.1
    • /
    • pp.6.1-6.10
    • /
    • 2021
  • Objectives: The aim of this study was to evaluate the corrosion resistance of heat-treated (Reciproc and WaveOne) and non-heat-treated (ProTaper and Mtwo) superelastic nickel-titanium endodontic files when immersed in a 5.25% sodium hypochlorite solution. Materials and Methods: Anodic polarization curves were obtained with potential sweeps that began at the open circuit potential or corrosion potential (Ecorr). The pitting potential (Epit) was identified on the anodic polarization curve as the potential at which a sudden increase in current was observed. The micromorphology of the 28 tested files was analyzed before and after the electrochemical assay using scanning electron microscope (SEM). The data were analyzed using 1-way analysis of variance with the post hoc Bonferroni test (for Ecorr) and the Student t-test for independent samples (for Epit). Results: The mean Ecorr values were 0.506 V for ProTaper, 0.348 V for Mtwo, 0.542 V for Reciproc, and 0.321 V for WaveOne files. Only WaveOne and Protaper files exhibited pitting corrosion, with Epit values of 0.879 V and 0.904 V, respectively. On the SEM images of the ProTaper and WaveOne files, cavities suggestive of pitting corrosion were detected. Conclusions: Signs of corrosion were observed in both heat-treated and non-heat-treated files. Of the evaluated files, WaveOne (a heat-treated file) and ProTaper (a non-heat-treated file) exhibited the lowest corrosion resistance.

The Effects of Artificial Dead Space on the Pulmonary Ventilation of Intubated Children with Mechanical Ventilation (기관 삽관후 인공호흡기를 적용한 개심술 환아의 인공기도 체외 용적이 폐환기 상태에 미치는 영향)

  • 유정숙;윤선희;송계희;민열하
    • Journal of Korean Academy of Nursing
    • /
    • v.31 no.1
    • /
    • pp.31-42
    • /
    • 2001
  • This study was done to evaluate the effect reducing artificial dead space on intubated children. Data were collected from July 1st, 1998 to August 31st, 1999. The subjects were selected from a pediatric intensive care unit of 'S' hospital and intubated with 3.5 mm or 4.5 mm endotracheal tube after open heart surgery. They were composed of 34 patients : 17 patients were assigned to the experimental group and the rest of them were placed in the control group. The artificial airway volume was minimized in the experimental group, and the control group maintained the artificial airway volume. ETCO2, PaCO2, SPO2 were measured as indicators of pulmonary ventilation. The tools of this study were GEM-Premier and Space-Lab patient monitors. The data were analyzed using the SPSS/PC+ program. The $\chi$2 -test was used to find general characteristics. The t-test was used to test the homogenety of the pulmonary ventilation status and mechanical ventilation setting before intervention between the two groups. Also, the paired t-test was used to examine the hypothesis. The results can be summerized as : 1. CO2 can be expelled effectively from the body in case artificial dead space was decreased. 2. As the artificial dead space was reduced, the difference between ETCO2 and PaCO2 was decreased, in other words pulmonary ventilation was improved. 3. If the artificial dead space occupied above 15 percent of tidal volume, the effect of CO2 was retention revealed in the body. 4. If the artificial dead space occupied below effect. Based on the results, the following is suggested to be applied practically : 1. A kind of the ventilator circuit acting artificial dead space should be removed from the intubated children with mechanical ventilaion. 2. The endotracheal tube should not be cut because extra-body space of the endotracheal tube did not have an effect on the dead space of the intubated children. Since the researcher could not cover this aspect in the study, they recommend the following. 1. The study should be extended to the other pulmonary disease patients for the effect of improving pulmonary ventilation. 2. Also, further studying with a more narrow interval in the extra-body space of the artificial airway will be able to explain the point of artificial dead space with proper ventilation.