• Title/Summary/Keyword: in-circuit test

Search Result 1,629, Processing Time 0.037 seconds

Flexible Durability of Ultra-Thin FPCB (초박형 FPCB의 유연 내구성 연구)

  • Jung, Hoon-Sun;Eun, Kyoungtae;Lee, Eun-Kyung;Jung, Ki-Young;Choi, Sung-Hoon;Choa, Sung-Hoon
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.21 no.4
    • /
    • pp.69-76
    • /
    • 2014
  • In this study, we developed an ultra-thin flexible printed circuit board(FPCB) using the sputtered flexible copper clad laminate. In order to enhance the adhesion between copper and polyimide substrate, a NiMoNb addition layer was applied. The mechanical durability and flexibility of the ultra-thin FPCB were characterized by stretching, twisting, bending fatigue test, and peel test. The stretching test reveals that the ultra-thin FPCB can be stretched up to 7% without failure. The twisting test shows that the ultra-thin FPCB can withstand an angle of up to $120^{\circ}$. In addition, the bending fatigue test shows that the FPCB can withstand 10,000 bending cycles. Numerical analysis of the stress and strain during stretching indicates the strain and the maximum von Mises stress of the ultra-thin FPCB are comparable to those of the conventional FPCB. Even though the ultra-thin FPCB shows slightly lower durability than the conventional FPCB, the ultra-thin FPCB has enough durability and robustness to apply in industry.

Configuration of Test Field for Introduction of IEC 60364-4-44 to Domestic System (IEC 60364-4-44의 국내 도입을 위한 실증시험장 구성)

  • Nam, Kee-Young;Choi, Sang-Bong;Jeong, Seong-Whan;Lee, Jae-Duck;Ryoo, Hee-Suk;Kim, Dae-Kyeong;Jung, Dong-Hak
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.731-732
    • /
    • 2007
  • This paper presents the final configuration of test field and test items for the application of IEC 60364-4-44 in Korea. IEC 60364-4-44 provides rules for the protection against the effects of conducted and radiated disturbances on electrical installations. Especially this standard deals with the protection of low voltage facility against the ground fault in the high voltage side of power distribution system. Many countries define the regulations on the use of electrical facilities based on their own power system and technical references which are considered to be suitable for them. The background of circuit of IEC 60364-4-44 is based on the ungrounded system as most of European countries. However, domestic electric power distribution system is based on multi-grounding system different from European system. Therefore, it is necessary to evaluate or prove the effect of the IEC 60364-4-44 for introducing and applying it to the domestic grounding system as a national standard. The authors with KEA(Korea Electric Association) carried out a project on the application of IEC 60364-4-44 to Korean electrical installations of buildings sponsored by Korean ministry of commerce, industry and energy for three years(2004.4.1$\sim$2007.3.31). The test field is established in K.E.R.I.(Korea Electrotechnology Research Institute), which is the purpose of evaluating the formula to calculate touch voltage and stress voltage in the IEC standards. This paper presents some considerations and final configuration of test field to evaluate and introduce the IEC 60364-4-44 applicable to domestic rule for the protection against ground fault.

  • PDF

Development and Verification of Lightning Induced Transient Protection Device for Avionics Computer (항공기 탑재 컴퓨터용 간접낙뢰 보호장치 개발 및 검증)

  • Sim, Yong-gi;Ahn, Tae-sik;Park, Jun-hyun;Han, Jong-pyo;Yang, Seo-hee
    • Journal of Advanced Navigation Technology
    • /
    • v.19 no.5
    • /
    • pp.395-402
    • /
    • 2015
  • This paper introduces the design details and test procedures of the lightning induced transient protection device for protecting the damage caused by indirect lightning strike on the computer mounted on the aircraft. Lightning induced surge voltage is bring a malfunction or damage to the aircraft electrical and electronic equipment, that is referred to indirect effects of lightning. In order to protect the electronic equipment on aircraft from the indirect effects of lightning, that is achieved by analyzing the effect on aircraft from lightning and protect design for each devices. In this paper, we introduce an indirect lightning strike level decisions, the protection circuit design method according to the chosen level through the RTCA DO-160G Section 22 category analysis and selection was performed in order to protect the damage caused by indirect lightning strikes in the protected equipment. In addition, we show the indirect lightning effects verification test performed to validate the designed protection circuits.

Predicting the Significance of On-Chip Inductance Issues Based on Inductance Screening Results (Interconnect Scaling에 따른 온칩 인터커넥 인덕턴스의 중요성 예측)

  • Kim, So-Young
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.48 no.3
    • /
    • pp.25-33
    • /
    • 2011
  • As chip operating frequency increases, there is growing concern about on-chip interconnect inductance. This paper presents a two-step inductance screening tool to select interconnects with significant inductance effects in a VLSI design. Test chips designed in different CMOS technology nodes are examined. The inductance screening results show that 0.1% of the nets in a design have inductance problems with chips running at its operating frequency, supporting the necessity of a screening process instead of adding inductance model to all the nets in the design. The increase in resistance due to geometry scaling will strongly affect the significance of inductance on delay as technology and frequency scale. Since higher frequency worsens inductance problem and geometry scaling alleviates it, inductance screening tool can provide useful guidelines to circuit designers.

Design and Fabrication of a Surge Generator with Coupling/Decoupling Networks (커플링/디커플링 네트워크 내장 서지발생장치의 설계 및 제작)

  • Kim, Nam-Hoon;Kang, Tae-Ho;Shin, Han-Sin;Kil, Gyung-Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.33 no.2
    • /
    • pp.130-134
    • /
    • 2020
  • Metal oxide varistors (MOVs) protect circuits and devices from transient overvoltages in electric power systems. However, a MOV continuously deteriorates owing to manufacturing defects or repetitive protective operations from transient overvoltages. A deteriorated MOV may result in a short circuit or a line-ground accident. Previous studies focused on the analysis of deterioration mechanisms and condition diagnosis techniques for MOVs owing to their recent growth of use. An accelerated deterioration experiment under the same conditions in which a MOV operates is essential. In this study, we designed and fabricated a surge generator that can apply a surge current to a MOV connected to AC mains. The coupling network operates at a low impedance against the surge current from the surge generator and transfers the surge current to the MOV under test. It also acts as a high impedance against AC mains for the AC voltage not to be applied to the surge generator. The decoupling network operates at a high impedance against the surge current and blocks the surge current from AC mains. It also acts as a low impedance against AC mains for the AC voltage to be applied to the MOV under test. The prototype surge generator can apply the 8/20 us up to 15 kA on AC voltages in the approximate range of 110~450 V, and it fully operates on a LabVIEW-based program.

X-band Tx and Rx Filters of Earth Terminals for Satellite Communications (위성통신 단말용 X 대역 송수신 필터)

  • Kwak, Changsoo;Uhm, Manseok;Jin, Bongcheol;Seo, Hakkeum;Suh, Joonsuk;Yom, Inbok
    • Journal of Satellite, Information and Communications
    • /
    • v.9 no.2
    • /
    • pp.52-57
    • /
    • 2014
  • In this paper, designs and test results of X-band Tx and Rx filters for satellite communications are presented. The passbands are 7.9 ~ 8.4 GHz and 7.25 ~ 7.75 GHz for the Tx filter and the Rx filter respectively. Both of the filters require very high rejection performance between the two passbands. In order to make these filters in an in-line type, non-resonating node method was adopted and E-plane junction was used for the non-resonating node. Design procedures of circuit model design and full-wave electromagnetic model design are described. The test results show that all the performances meet requirements including temperature variations and the sizes are smaller than those of domestic commercial filters by about 30 ~ 40 %.

Design and Fabrication of an Electromagnetic Flowmeter (전자기유량계의 설계 및 제작)

  • Lim, Ki-Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.10
    • /
    • pp.1385-1392
    • /
    • 2003
  • An electromagnetic flowmeter(EMF) was developed and its characteristics were compared with a commercial EMF. The developed EMF was designed as the 100 mm nominal diameter. A signal processing circuit was also developed for generating the magnetic field and converting the flow signal to flowrate and flow quantity. In order to obtain a more stable and reliable flow signal, the double magnetizing frequency was adopted for magnetizing the coil of the EMF. For the characterization of the developed EMF, the uncertainty of calibrator was estimated within $\pm$0.5 %. The evaluation procedure of the uncertainty followed the ISO Guide to the Expression of Uncertainty in Measurement. It was found that the flow signals between the electrodes were about $\pm$60-$\pm$300$\mu$V, which were sufficient for the discrimination of flowmeter and the protection of noise. The test results against the calibrator showed the good linearity in the range of 3 ㎥/h and 70 ㎥/h. A commercialized design of the EMF based on the current study will be technically more competitive in domestic and foreign market.

A Study on the Parameters Estimation for SOC and SOH of the Battery (SOC 및 SOH 추정을 위한 파라미터 추정기법에 관한 연구)

  • Park, Sung-Jun;Song, Gwang-Suk;Park, Seong-Mi
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.5
    • /
    • pp.853-863
    • /
    • 2020
  • As the battery ages, the internal resistance of the battery increases, so the loss due to the internal resistance increases at the same charging current, causing the battery temperature to rise, which further accelerates battery aging. Therefore, it is necessary to optimize the charging conditions according to the aging of the battery or the current charge amount, and to accurately estimate this, estimation of the parameters of the equivalent circuit is most important. This paper proposes a new measurement technique that can measure the internal resistance of a battery by analyzing a specific high frequency voltage and current applied to the battery. In addition, in order to test the validity of the proposed measurement technique, the current charging amount was estimated based on the measured internal resistance, and the terminal voltage of the constant current charging mode was automatically set and operated. As a result, good results were obtained regardless of the battery voltage. If this equipment is installed in the charging device, it is believed that it will be of great help in the stability management of the aging reusable battery.

A Study on Analysis of Wavelength-Conversion Function in DWDM Network of Multiple Wavelength Environment (다중 파장 환경의 DWDM 망에서 파장 변환 기능에 대한 분석)

  • Kim, Yong-Seong;Lee, Jae-Dong;Woo, Chong-Ho
    • The Journal of Korean Association of Computer Education
    • /
    • v.9 no.1
    • /
    • pp.97-106
    • /
    • 2006
  • In the next-generation Internet backbone network, DWDM technology was appeared as an alternative to solve circuit shortage of existing TDM-based Internet. In this DWDM Network, it is inevitable to consider wavelength-conversion function as well as RWA in case of setting up connection for the efficient use of resources and customer satisfaction. This study is to describe an efficient strategy for the wavelength-conversion function with a limited range and for the use of a wavelength converter with the selected node, and to verify the optimum use of a wavelength converter through the performance test.

  • PDF

Analysis of Cold Gas Flow in Puffer Type GCB Considering the Real Gas Property of $SF_6$ ($SF_6$ 가스의 실제 기체특성을 고려한 파퍼식 가스차단기 내의 냉가스 유동해석)

  • 김홍규;정진교;박경엽
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.3
    • /
    • pp.129-134
    • /
    • 2004
  • To analyze the performance of the gas circuit breaker(GCB), the flow field variables such as temperature, pressure and density should be evaluated accurately In the puffer chamber of puffer type GCB, the pressure rise may Exceed 20 bar and in this range of high pressure, $SF_6$ gas deviates the ideal gas property. Therefore, the real gas property of $SF_6$ should be taken into consideration for the accurate analysis of flow field. This paper presents the analysis technique of cold gas flow in GCB employing the real gas state equation of SF6. The FVFLIC method is Employed to solve the axisymmetric Euler equation. To reduce the computational effort of real gas state equation, the relationship between density and pressure is approximated by the polynomial at the temperature of 300K. The proposed method is applied to the test GCB model and simulation results show good agreement with the experimental ones.