• Title/Summary/Keyword: in-circuit test

Search Result 1,629, Processing Time 0.028 seconds

Reliability Analysis of Measurement System by Observability Identification technique (기관측성 판정기법에 의한 측정시스템의 신뢰도분석)

  • Lee, Eung-Hyuk;Hong, Kwak-No;Hyun, Moon-Young
    • Proceedings of the KIEE Conference
    • /
    • 1987.11a
    • /
    • pp.125-128
    • /
    • 1987
  • This paper deals with the topological observability analysis and the derivation of a reliability evaluation formula of a measurement system for state estimation. An analogy of the DC power flow method to the DC circuit analysis is introduced, and all the relationship between power flows and phase angles are replaced by the corresponding current-voltage relation. As a result, a set of topological measurement equation expressed in the form of the incidence matrix is derived for the topological analysis, and the observability test is carried out by examining the rank of the measurement matrix. The reliability evaluation formula was derived experimentally by testing the observability of sample systems of IEEE-14, IEEE-3.0, IEEE-57.

  • PDF

Development of a Compact 50 kV, 10 kW Transformer for High Frequency Switch Mode (50 kV, 10kW 소형 고주파 전원장치 변압기 개발)

  • Son, Y.G.;Oh, J.S.;Jang, S.D.;Cho, M.H.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07f
    • /
    • pp.2027-2029
    • /
    • 1998
  • We have developed a compact high frequency switch mode converter (HFSMC) power supply with DC 50 kV output voltage and 10 kW output power. Since the inverter circuit uses 25 kHz rescharging scheme, the current is flowing with t kHz. For the efficient output voltage transform performed a simple design process using the transformer principle and the commercial specification. For the DC 50 kV output, we employed 7 pa windings of secondary coils for the series stac connection of the output with full-bridge rectifi In this paper the design detail and the test re the high frequency transformer together with HFSMC power supply are presented.

  • PDF

Development of an active gust generation mechanism on a wind tunnel for wind engineering and industrial aerodynamics applications

  • Haan, Fred L. Jr.;Sarkar, Partha P.;Spencer-Berger, Nicholas J.
    • Wind and Structures
    • /
    • v.9 no.5
    • /
    • pp.369-386
    • /
    • 2006
  • A combination Aerodynamic/Atmospheric Boundary Layer (AABL) Wind and Gust Tunnel with a unique active gust generation capability has been developed for wind engineering and industrial aerodynamics applications. This facility is a cornerstone component of the Wind Simulation and Testing (WiST) Laboratory of the Department of Aerospace Engineering at Iowa State University (ISU). The AABL Wind and Gust tunnel is primarily a closed-circuit tunnel that can be also operated in open-return mode. It is designed to accommodate two test sections ($2.44m{\times}1.83m$ and $2.44m{\times}2.21m$) with a maximum wind speed capability of 53 m/s. The gust generator is capable of producing non-stationary gust magnitudes around 27% of the mean flow speed. This paper describes the motivation for developing this gust generator and the work related to its design and testing.

A Study on Heat Transfer Performances of a Heat Pipe Heat Sink for Power Control Semiconductors (전력제어 반도체용 히트파이프 냉각기의 열전달 성능 연구)

  • 강환국;김재진;김철주
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.8
    • /
    • pp.701-709
    • /
    • 2001
  • In this days, heat pipe heat sink has been widely applied to power controllers for railway substations to remove heat from power semiconductors(diodes or thyristors). The heat pipe heat sink consists of a aluminum heating block for mounting the thyristor, 2~3 heat pipes and large number of aluminum fins. The present study was to get fundamental informations of the structure, design parameters and heat transfer performances of heat pipe heat sink. Series of operational test for a unit with 3 heat pipes were performed and its heat flow circuit was analysed from the experimentally obtained data on wall temperature distribution. Total resistance was ranged 0.02~$0.03^{\circ}C$/W for a power range from 40W to400W. The time to get the steady state was approximately longer than 20 minutes, and overshooting was not occurred during start up operation.

  • PDF

Load-Adaptive Address Energy Recovery Technique for Plasma Display Panel

  • Lee Jun-Yeong
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2005.05a
    • /
    • pp.192-200
    • /
    • 2005
  • A high speed address recovery technique for AC plasma display panel(PDP) is proposed. By removing the GND switching operation, the recovery speed can be increased and switching loss due to GND switch also becomes to be reduced. The proposed method is able to perform load-adaptive operation by controlling the voltage level of energy recovery capacitor, which prevents increasing inefficient power consumption caused by circuit loss during recovery operation. Thus, th e technique shows the minimum address power consumption according to various displayed images, different from prior methods operating in fixed mode regardless of images. Test results with 50' HD single- scan PDP(resolution : $1366{\times}768$) show that less than 350ns of recovery time is successfully accomplished and about $54\%$ of the maximum power consumption can be reduced, tracing minimum power consumption curves.

  • PDF

Flight Model Development of Linearized Channel Amplifier (선형화 채널 증폭기 비행모델 개발)

  • Hong, Sang-Pya;Go, Yeong-Mok;Yang, Ki-Dug;Ra, Keuk-Hwan
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.8 no.3
    • /
    • pp.83-90
    • /
    • 2009
  • This paper presents the design and measurement of a flight model for a Ku-Band Linearized Channel Amplifier. All MMICs, Variable Gain Amplifier (VGA), Variable Voltage Attenuator ('.IVA), Branch line Coupler and Detector for Pre-distorter are fabricated using a Thin-Film Hybrid process. The performance of the fabricated module is verified through the radio frequency circuit simulation tool and electrical function test in space environment.

  • PDF

Design and Fabrication of Self-Oscillating Mixer Using Subharmonic Injection Locked Oscillator for 5GHz (주입 동기 방식을 이용한 5GHz 대역 자기발진 주파수 혼합기의 설계 및 제작)

  • 류재종;이주갑;류원열;윤영섭;최현철
    • Proceedings of the IEEK Conference
    • /
    • 2003.11c
    • /
    • pp.86-89
    • /
    • 2003
  • In this paper, Self-Oscillating Mixer is designed by oscillator that was based on a general nonlinear input-output model for the subharmonic injection locked oscillator is analysed. We have designed and fabricated the Self-Oscillating Mixer for 5GHz by proposed subharmonic injection locked oscillator based frequency synthesizer structure that have characteristic of good frequency sensitivity, good phase noise. The design strategy leading to an optimized SILO with regards to its locking range is described and a test SOM circuit is demonstrated a 4dB conversion gain at 280MHz IF frequency from the carrier.

  • PDF

High Reliability Optical Splitters Composed of Planar Lightwave Circuits (PLC Optical Splitter(1${\times}$32)의 신뢰성 평가)

  • Gu, Hyeon-Deok;Im, Hae-Yong;Park, Jong-Hyeok;Park, Gang-Hui
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2008.07a
    • /
    • pp.265-266
    • /
    • 2008
  • The environmental and mechanical reliability of planar lightwave circuit (PLC)-type optical splitter modules is investigated with references [1, 3]. The module is composed of Y-branching silica-based waveguides on Si connected to optical fiber with UV-curable adhesives and is packaged in a metal case which is filled with humidity-resistant resin. High optical performance such as low loss, low reflection, and thermal stability are obtained through the use of this fiber connection technique. Ten reliability tests including long-term environmental and mechanical and ALT test were carried out for more then ten $1{\times}32$ channel PLC splitter modules.

  • PDF

A Study on Battery Simulator Including Aging and Dynamic Impedance Model (노화 및 동특성 임피던스 모델을 포함한 배터리 시뮬레이터에 관한 연구)

  • Lee, Jong-Hak;Kim, Soo-Bin;Oh, Sang-Keun;Song, Seung-Ho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.3
    • /
    • pp.171-180
    • /
    • 2020
  • This paper presents the implementation and control methods of a battery simulator. The proposed battery simulator can emulate the dynamic characteristics of any actual battery using the second RC ladder model of the equivalent circuit. Moreover, it can emulate the variation of impedance, which is the result of the change of battery characteristics due to the aging effect. The parameters of the battery simulator can be derived from the sequence of tests of the actual battery or only from the data supplied by the battery manufacturer. Proposed methods for the battery simulator are tested by extensive experiments. Test results show that the proposed battery simulator can emulate not only the dynamic characteristics but also the aging effects of the actual battery in real time.

Characteristics Analysis of the Solenoid Valve for Exhaust Brake (배기 브레이크용 솔레노이드 밸브의 특성 해석)

  • 윤소남;함영복
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.1
    • /
    • pp.190-195
    • /
    • 2004
  • An exhaust brake system is composed of a gate valve, a pneumatic cylinder and an on-off solenoid valve. An on-off solenoid valve which is a key component of the exhaust brake system ought to have characteristics such as high reliability and long life for reducing the foot brake and tires damage, and for driver's fatigue relief of middle/large size vehicles running a long distance. In this paper, an on-off solenoid valve which is used for vehicle brake system was studied. For the performance evaluation of the on-off solenoid, electromagnetic characteristics and dynamic characteristics are analyzed. On the basic study for the performance improvement of exhaust brake system, pneumatic circuit and pneumatic valve of on-off solenoid type were suggested and the performance of pneumatic valve through the test procedure was evaluated.