• Title/Summary/Keyword: impression materials

Search Result 313, Processing Time 0.023 seconds

A Study on Design Characteristics in Casa Battle and Gaudi′s Philosophy of Architecture (카사 바트요의 조형적 특성과 가우디의 건축적 사고 연구)

  • Kim Dae Nyun
    • Journal of the Korean housing association
    • /
    • v.15 no.5
    • /
    • pp.21-32
    • /
    • 2004
  • The purpose of this study is to interpret Gaudi's philosophy of architecture through an analysis of the design characteristics in his remodeling of Casa Battlo. A review of the literature related to Casa Battlo as well as a field study in Barcelona to see the building were made for this study. The conclusions were as follows; Casa Battle is one of the best examples of Gaudi's attempts at creating a surreal atmosphere and should be evaluated in light of the following considerations: 1) Casa Battle as a remodeled house presented its own restrictions to Gaudi that he overcame by introducing characteristic design elements into the remodeling process; 2) the achievement, a perfect sculpture expressing continuity through a gorgeous colour scheme using different materials and design motifs with a dynamic spiral shape, originated from Gaudi's observations of nature and his experiences working in modeling studios; 3) a visualized embodiment of Gaudi's naturalism and functionalism through the impression of perpetual movement and continuity as formative symbols of genesis, life, death, and transmigration of the soul, originated from Gaudi's personal experiences of the early deaths of several close family members; 4) the design is meant to show the same processes of creation used by nature rather than a mere imitation of nature. Gaudi was not only a person dedicated obsessively to his profession as an architect, but also a rationalist fundamentally in the way he operated. It was expected that this study could be employed as a small stimulus to challenge the paradigm of housing remodeling projects -a hot issue in today's Korea- especially in their philosophical aspect.

A Study on Used Colors Characteristic of Case Study for Children Play Therapy Center (국내.외 놀이치료 시설의 사례분석을 통한 사용 색채 특성에 관한 연구)

  • Choi, Jin-Hee
    • Korean Institute of Interior Design Journal
    • /
    • v.20 no.4
    • /
    • pp.29-36
    • /
    • 2011
  • This study aims to be the useful resources for selecting play therapy facility in the future by analysis of used colors in the play therapy facility as the subsequent studies of the thesis of KIID in 2010, titled 'Study on the planning factors of case study for children's play therapy center'. As research method of this study, the overall understanding about play therapy facility was improved through theoretical considerations, and it was about the Moon-Spencer's theory of color harmony which will be used for the framework of case study. In Section 3, the field trips at 6 facilities were conducted as the case research and the data research through website was conducted for case study. Moon-Spencer's theory of color harmony used the Munsell's color Order System, so after measuring CMYK value of the picture for the case research through photo shop, the color, brightness and saturation were measured through Munsell Conversion program. The following three kinds of features were drawn by research of the harmony and disharmony of used colors for the cases after substituting the theory of color harmony through the measured color. brightness, and saturation. First. series Y and YR were used mainly for warm image as the concept of play therapy room. Second, the various colors were used for comfortable image like home. But the various patterns were used by mixing for the therapy room F, so it gives confusing impression. Third, series YR and achromatic color as the color of wood were used unavoidably for using materials of manufactured goods.

Ceramic molar crown reproducibility by digital workflow manufacturing: An in vitro study

  • Jeong, II-Do;Kim, Woong-Chul;Park, Jinyoung;Kim, Chong-Myeong;Kim, Ji-Hwan
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.4
    • /
    • pp.252-256
    • /
    • 2017
  • PURPOSE. This in vitro study aimed to analyze and compare the reproducibility of zirconia and lithium disilicate crowns manufactured by digital workflow. MATERIALS AND METHODS. A typodont model with a prepped upper first molar was set in a phantom head, and a digital impression was obtained with a video intraoral scanner (CEREC Omnicam; Sirona GmbH), from which a single crown was designed and manufactured with CAD/CAM into a zirconia crown and lithium disilicate crown (n=12). Reproducibility of each crown was quantitatively retrieved by superimposing the digitized data of the crown in 3D inspection software, and differences were graphically mapped in color. Areas with large differences were analyzed with digital microscopy. Mean quadratic deviations (RMS) quantitatively obtained from each ceramic group were statistically analyzed with Student's t-test (${\alpha}=.05$). RESULTS. The RMS value of lithium disilicate crown was $29.2\;(4.1){\mu}m$ and $17.6\;(5.5){\mu}m$ on the outer and inner surfaces, respectively, whereas these values were $18.6\;(2.0){\mu}m$ and $20.6\;(5.1){\mu}m$ for the zirconia crown. Reproducibility of zirconia and lithium disilicate crowns had a statistically significant difference only on the outer surface (P<.001). The outer surface of lithium disilicate crown showed over-contouring on the buccal surface and under-contouring on the inner occlusal surface. The outer surface of zirconia crown showed both over- and under-contouring on the buccal surface, and the inner surface showed under-contouring in the marginal areas. CONCLUSION. Restoration manufacturing by digital workflow will enhance the reproducibility of zirconia single crowns more than that of lithium disilicate single crowns.

Evaluation of internal fit of interim crown fabricated with CAD/CAM milling and 3D printing system

  • Lee, Wan-Sun;Lee, Du-Hyeong;Lee, Kyu-Bok
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.4
    • /
    • pp.265-270
    • /
    • 2017
  • PURPOSE. This study is to evaluate the internal fit of the crown manufactured by CAD/CAM milling method and 3D printing method. MATERIALS AND METHODS. The master model was fabricated with stainless steel by using CNC machine and the work model was created from the vinyl-polysiloxane impression. After scanning the working model, the design software is used to design the crown. The saved STL file is used on the CAD/CAM milling method and two types of 3D printing method to produce 10 interim crowns per group. Internal discrepancy measurement uses the silicon replica method and the measured data are analyzed with One-way ANOVA to verify the statistic significance. RESULTS. The discrepancy means (standard deviation) of the 3 groups are $171.6\;(97.4){\mu}m$ for the crown manufactured by the milling system and 149.1 (65.9) and $91.1\;(36.4){\mu}m$, respectively, for the crowns manufactured with the two types of 3D printing system. There was a statistically significant difference and the 3D printing system group showed more outstanding value than the milling system group. CONCLUSION. The marginal and internal fit of the interim restoration has more outstanding 3D printing method than the CAD/CAM milling method. Therefore, the 3D printing method is considered as applicable for not only the interim restoration production, but also in the dental prosthesis production with a higher level of completion.

Evaluation of the marginal and internal fit of a single crown fabricated based on a three-dimensional printed model

  • Jang, Yeon;Sim, Ji-Young;Park, Jong-Kyoung;Kim, Woong-Chul;Kim, Hae-Young;Kim, Ji-Hwan
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.5
    • /
    • pp.367-373
    • /
    • 2018
  • PURPOSE. To evaluate the fit of a crown produced based on a 3D printed model and to investigate its clinical applicability. MATERIALS AND METHODS. A master die was fabricated with epoxy. Stone dies were fabricated from conventional impressions (Conventional stone die group: CS, n=10). Digital virtual dies were fabricated by making digital impressions (Digital Virtual die group: VD, n=10). 3D data obtained from the digital impression was used to fabricate 3D printed models (DLP die group: DD, n=10, PolyJet die group: PD, n=10). A total of 40 crowns were fabricated with a milling machine, based on CS, VD, DD and PD. The inner surface of all crowns was superimposed with the master die files by the "Best-fit alignment" method using the analysis software. One-way and 2-way ANOVA were performed to identify significant differences among the groups and areas and their interactive effects (${\alpha}=.05$). Tukey's HSD was used for post-hoc analysis. RESULTS. One-way ANOVA results revealed a significantly higher RMS value in the 3D printed models (DD and PD) than in the CS and DV. The RMS values of PD were the largest among the four groups. Statistically significant differences among groups (P<.001) and between areas (P<.001) were further revealed by 2-way ANOVA. CONCLUSION. Although the fit of crowns fabricated based on the 3D printed models (DD and PD) was inferior to that of crowns prepared with CS and DV, the values of all four groups were within the clinically acceptable range (<$120{\mu}m$).

Diagnostic Value of Preoperative Ultrasonographic Evaluation on Thyroid Cancer (갑상선 암의 판정에 대한 술전 초음파의 의의)

  • Yoon Kil-Hoon;Ryou Kie-Sun;Jung Jin-Young;Jo Jae-Hyun;Kim Myung-Wook;So Euy-Young
    • Korean Journal of Head & Neck Oncology
    • /
    • v.15 no.1
    • /
    • pp.66-69
    • /
    • 1999
  • Background and Objectives: It is critical to distinguish benign from malignant thyroid nodule and to select a patient for surgery. Even though the U/S study dose not make great contribution to diagnose a malignant thyroid nodule, it is widely used in the evaluation of anatomic feature of thyroid. The authors tried to estimate the efficacy of the U/S study in preoperative diagnosis of malignant thyroid nodule. Materials and Method: At the department of General Surgery of Ajou University, 75 patients who were operated after diagnosis with thyroid nodule by U/S study between July 1996 to June 1997 were retrospectively analyzed. By comparing the U/S impression that implies malignant thyroid nodule to FNAC and post-operative pathologic results ware as follows. Results: 1) Absence of cystic change, presence of internal hypoechogenicity, lobulation, calcification, thick and irregular halo, and nodule more than 4cm in diameter on U/S were considered significant statistically for the diagnosis of malignancy(Chi-square test, p<0.05) 2) Presence of internal hypoechogenicity or thick and irregular halo has the validity in Logistic regression analysis. 3) FNAC was done in 65 case. 19 case were malignant, 11 case were suspicious and 46 patients were benign (sensitivity 52.6%, specificity 87%). 4) The findings of U/S which are hypoechogenic and thick and irregular halo show 82% sensitivity and 97% specificity. In combination with the findings of FNAC that imply benign or suspicious lesions, the sensitivity was 100% and the specificity was 97%. Conclusion: This study suggest that the hypoechogenicity and thick and irregular halo on U/S are important information for the diagnosis of thyroid malignancy which were considered benign or suspicious after FNAC.

  • PDF

Accuracy of 3D white light scanning of abutment teeth impressions: evaluation of trueness and precision

  • Jeon, Jin-Hun;Kim, Hae-Young;Kim, Ji-Hwan;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.6
    • /
    • pp.468-473
    • /
    • 2014
  • PURPOSE. This study aimed to evaluate the accuracy of digitizing dental impressions of abutment teeth using a white light scanner and to compare the findings among teeth types. MATERIALS AND METHODS. To assess precision, impressions of the canine, premolar, and molar prepared to receive all-ceramic crowns were repeatedly scanned to obtain five sets of 3-D data (STL files). Point clouds were compared and error sizes were measured (n=10 per type). Next, to evaluate trueness, impressions of teeth were rotated by $10^{\circ}-20^{\circ}$ and scanned. The obtained data were compared with the first set of data for precision assessment, and the error sizes were measured (n=5 per type). The Kruskal-Wallis test was performed to evaluate precision and trueness among three teeth types, and post-hoc comparisons were performed using the Mann-Whitney U test with Bonferroni correction (${\alpha}=.05$). RESULTS. Precision discrepancies for the canine, premolar, and molar were $3.7{\mu}m$, $3.2{\mu}m$, and $7.3{\mu}m$, respectively, indicating the poorest precision for the molar (P<.001). Trueness discrepancies for teeth types were $6.2{\mu}m$, $11.2{\mu}m$, and $21.8{\mu}m$, respectively, indicating the poorest trueness for the molar (P=.007). CONCLUSION. In respect to accuracy the molar showed the largest discrepancies compared with the canine and premolar. Digitizing of dental impressions of abutment teeth using a white light scanner was assessed to be a highly accurate method and provided discrepancy values in a clinically acceptable range. Further study is needed to improve digitizing performance of white light scanning in axial wall.

A new method to measure the accuracy of intraoral scanners along the complete dental arch: A pilot study

  • Iturrate, Mikel;Lizundia, Erlantz;Amezua, Xabier;Solaberrieta, Eneko
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.6
    • /
    • pp.331-340
    • /
    • 2019
  • PURPOSE. The purpose of this study is to assess the accuracy of three intraoral scanners along the complete dental arch and evaluate the feasibility of the assessment methodology for further in vivo analysis. MATERIALS AND METHODS. A specific measurement pattern was fabricated and measured using a coordinate measuring machine for the assessment of control distances and angles. Afterwards, the pattern was placed and fixed in replica of an upper jaw for their subsequent scans (10 times) using 3 intraoral scanners, namely iTero Element1, Trios 3, and True Definition. 4 reference distances and 5 angles were measured and compared with the controls. Trueness and precision were assessed for each IOS: trueness, as the deviation of the measures from the control ones, while precision, as the dispersion of measurements in each reference parameter. These measurements were carried out using software for analyzing 3-dimensional data. Data analysis software was used for statistical and measurements analysis (α=.05). RESULTS. Significant differences (P<.05) were found depending on the intraoral scanner used. Best trueness values were achieved with iTero Element1 (mean from 10 ± 7 ㎛ to 91 ± 63 ㎛) while the worst values were obtained with Trios3 (mean from 42 ± 23 ㎛ to 174 ± 77 ㎛). Trueness analysis in angle measurements, as well as precision analysis, did not show conclusive results. CONCLUSION. iTero Element1 was more accurate than the current versions of Trios3 and True Definition. Importantly, the proposed methodology is considered reliable for analyzing accuracy in any dental arch length and valid for assessing both trueness and precision in an in vivo study.

Marginal and internal fit of 3D printed provisional crowns according to build directions

  • Ryu, Ji-Eun;Kim, Yu-Lee;Kong, Hyun-Jun;Chang, Hoon-Sang;Jung, Ji-Hye
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.4
    • /
    • pp.225-232
    • /
    • 2020
  • PURPOSE. This study aimed to fabricate provisional crowns at varying build directions using the digital light processing (DLP)-based 3D printing and evaluate the marginal and internal fit of the provisional crowns using the silicone replica technique (SRT). MATERIALS AND METHODS. The prepared resin tooth was scanned and a single crown was designed using computer-aided design (CAD) software. Provisional crowns were printed using a DLP-based 3D printer at 6 directions (120°, 135°, 150°, 180°, 210°, 225°) with 10 crowns in each direction. In total, sixty crowns were printed. To measure the marginal and internal fit, a silicone replica was fabricated and the thickness of the silicone impression material was measured using a digital microscope. Sixteen reference points were set and divided into the following 4 groups: marginal gap (MG), cervical gap (CG), axial gap (AG), and occlusal gap (OG). The measurements were statistically analyzed using one-way ANOVA and Dunnett T3. RESULTS. MG, CG, and OG were significantly different by build angle groups (P<.05). The MG and CG were significantly larger in the 120° group than in other groups. OG was the smallest in the 150° and 180° and the largest in the 120° and 135° groups. CONCLUSION. The marginal and internal fit of the 3D-printed provisional crowns can vary depending on the build angle and the best fit was achieved with build angles of 150° and 180°.

A Study of Functional Evaluation in Stroke Patients (뇌졸중 환자의 기능평가에 대한 연구 -Modified Barthel Index 및 PULSES Profile에 의한 평가성적을 중심으로-)

  • Ahn Jung-Kuk;Lim Hye-Hyun;Ahn So-Yoon
    • The Journal of Korean Physical Therapy
    • /
    • v.4 no.1
    • /
    • pp.43-57
    • /
    • 1992
  • This study was conducted from August, 1980 to March, 9991 to the 40 subjects who were admitted to Kosin Medical Center and received rehabilitation treatment and discharged under the impression of stroke. The objectives are to evaluate the function of the activites of daily living and comprehensive function and find the status of rehabilitation treatment by Modified Barthel Index and PULSES Profile when first requested or rehabilitation treatment(T1), at 2 weeks after rehabilitation treatment(T2), at discharge(T3) and at the time of ambulatory treatment after 2 weeks(T4). The study materials were clinical charts and functional evaluation sheets, and the results are as follows : 21 subject$(52.5\%)$ were male, 19 subjects$(47.5\%)$ were female, and the age distribution was from 19 to 70 in age, the average age was 52.7. By the classification of diagnosis, 21 subjects$(52.5\%)$ were cerebral hemorrhage, 8 subjects$(20.2\%)$ were cerebral thrombosis, 6 subjects$(15.0\%)$ were cerebral embolism, and 5 subjects$(12.5\%)$ were cerebral infarction. The Barthel Index scores were 35.7, 54.5, 71.8, 88.7 on the average at T1, T2, T3, T4 respectively. The PULSES scores were 16.4, 13.7, 11.4, 8.7 on the average at T1, T2, T3, T4 respectively. Regarding the Pearson's correlation coefficient between the Barthel Index scores and the PULSES scores, it was -0.7991(P>0.001) at T1 and -0.8986(P>0.001) at T3, then beth of correlations were very high.

  • PDF