• Title/Summary/Keyword: implant occlusion

Search Result 402, Processing Time 0.023 seconds

Maxillary Resorption under Complete Dentures Opposing Mandibular Implant Supported Fixed Prosthesis: A Literature Review and Case Report (하악 임플란트 고정성 보철에 대합되는 상악 총의치 하방의 골흡수에 대한 고찰 및 증례보고)

  • Kim, Bo-Kuk;Kim, Yu-Lee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.4
    • /
    • pp.426-433
    • /
    • 2013
  • When restoring edentulous patients with lower complete denture, the smaller supportive and retentive area of mandible can lead to poor support and stability, denture dislodgement and pain resulting discomfort. In this situation, implant prosthesis can improve esthetics, stability and occlusal force. Whereas, patients with a upper complete denture can adjust more easier because of palate. Therefore, it is suggested to rehabilitate fully edentulous patients with lower implant-supported, upper complete denture as one of the treatment options. So, we are going to report the case and literature review about how the lower implant prosthesis opposing to upper complete denture affects the bone resorption of maxillary residual ridge.

Multidisciplinary approach of the problem of unaesthetic implants in the maxillary anterior dentition (비심미적 임플란트의 심미성 회복을 위한 다각적 접근법)

  • Joo, Ji-Young;Choi, Jeomil;Lee, Ju-Youn
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.31 no.2
    • /
    • pp.126-133
    • /
    • 2015
  • Periodontal tissue destroyed by inflammation is difficult to achieve regeneration of the tissue and esthetic restorations only by surgical methods. In particular, improvement of esthetics is more difficult if the problem is related to the implant. A 23 year old woman suffered from unesthetic anterior implant prosthesis. According to her dental history, a repeated bone graft and soft tissue graft failed at a local dental clinic. It was needed to resolve the inflammation and to improve the esthetics. A free gingival graft and ridge augmentation accompanied by guided bone regeneration and a vascularized interpositional periosteal connective tissue graft was performed. Instead of implant prosthesis, a conventional fixed bridge was adopted for better esthetic result. The patient was satisfied with the esthetic conventional fixed prosthesis. This case report introduces esthetic rehabilitation of unesthetic implant prosthetics in the maxillary anterior dentition by a combination of surgical and prosthetic approaches.

Implant assisted obturator in patient after maxillectomy: a case report (상악골 절제 환자에서 임플란트를 이용한 구개폐쇄장치 증례)

  • Seo, Yoon-Hee;Lee, Joon-Seok;Song, Young-Gyun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.4
    • /
    • pp.322-329
    • /
    • 2016
  • Reconstruction of the maxillectomy with an obturator is to restore masticatory, swallowing, phonetic and esthetic problems. Stress created by lateral forces is minimized by the proper selection of an occlusal scheme, elimination of premature occlusal contacts, and wide distribution of supporting area. It should be considered that properly designed retainers reduce the stresses transmitted to the abutment while the obturator is in function. The following clinical report presents palatal obturator treatment with implant assisted removable partial denture (IARPD) design that restores normal function and esthetics in patients who experienced maxillectomy and dental implant failure.

Full mouth rehabilitation of a patient with severe periodontitis using immediate loading after computer aided flapless implant surgery (심한 치주질환을 가진 환자에서 computer aided flapless surgery와 즉시 부하를 통한 전악 구강 회복 증례)

  • Kang, Seong hun;Choi, Yeon jo;Ryu, Jae jun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.1
    • /
    • pp.46-55
    • /
    • 2018
  • Oral rehabilitation of a patient having severe periodontitis with alveolar bone resorption and periodontal inflammation presents a challenge to clinicians. However, if appropriate implant placement according to the bone shape is selected, unnecessary bone grafting or soft tissue surgery can be minimized. In recent years, using cone beam CT and software, it has become possible to operate the planned position with the surgical guide made with 3D printing technology. This case was a 70 years old female patient who required total extraction of teeth due to severe periodontitis and performed a full-mouth rehabilitation with an implant - supported fixed prosthesis. During the surgery, the implant was placed in a flapless manner through a surgical guide. Immediate loading of the temporary prosthesis made by CAD/CAM method before surgery was done. Since then, we have produced customized abutments and zirconia prostheses, and have reported satisfactory aesthetic and functional recovery.

3-DIMENSIONAL FINITE ELEMENT ANALYSIS ON THE INFRAOCCLUSION OF FIXED IMPLANT PROSTHESIS FOR PARTIAL EDENTULISM (부분 무치악의 고정성 임플랜트 보철의 저위교합에 관한 3차원 유한요소법적 연구)

  • Kim, In-Seob;Choi, Choong-Kug;Chung, Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.3
    • /
    • pp.632-649
    • /
    • 1996
  • The purpose of this study was to examine, by the method of 3-dimentional finite element analysis. how infraocclusion affected the stress distribution in surrounding bone and osseointegrated prosthesis. The 3-dimentional finite element mandibular models were made, in which the first and second molars were removed and the two osseointegrated implants were placed in the first and second molar sites and implant supported fixed prostheses were constructed. Analysis of equivalent stress and displacement induced by strong occlusion or infraocclusion was performed under vertical or inclined distributed loads. The results were as follows; 1. Under vertical load of 50N or 500N, the model in which infraocclusion had not been allowed showed greater stress on implants and the supporting bone than on natural teeth. 2. In the model in which infraocclusion of $30{\mu}m$ had been allowed, implant-prosthesis on the molars had no contact with opposing teeth under vertical load of 50N, However with the same allowed infraocclusion and the model under vertical load of 500N, implant prosthesis on the second molar had contact with opposing teeth, and stress distribution occured properly on natural teeth and implants. 3. Under $45^{\circ}$ inclined load, the model in which infraocclusion had not been allowed showed greater stress on implants and the supporting bone than on natural teeth. There was greater stress in the case of $45^{\circ}$ inclined load than in the case of vertical load. 4. Under $45^{\circ}$ inclined load of 50N or 500N, the model in which infraocclusion of $30{\mu}m$, had been allowed showed no occlusal contact on the implants and occlusal contact on the natural teeth. 5. In partially edentulous cases with implant supported prosthesis, we can prevent excessive load on implants by allowing infraocclusion.

  • PDF

Utilization of digital technology in fabricating mandibular implant overdenture for skeletal class II edentulous patient: A case report (2급 악간관계를 보이는 하악 무치악 환자에서 디지털 진단기술을 이용한 임플란트 피개의치 수복증례)

  • Lee, Yeun-Yi;Hong, Seoungjin;Paek, Janghyun;Noh, Kwantae;Kwon, Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.4
    • /
    • pp.364-373
    • /
    • 2019
  • Unlike class I patients, skeletal class II patients have unstable occlusion thus leading to instability of mandibular complete denture. Therefore, mandibular implant overdenture has been the standard of care due to its advantages in stability and retention. The types of attachments can be divided into two categories: solitary and bar type. The indications vary between two categories. In this clinical report, digital technology was utilized from the implant planning to the choice of appropriate attachment. Implants were placed at the desired location as previously planned in terms of angle and depth. Maxillary removable partial denture and mandibular implant overdenture are expected to have fair prognosis.

Machining Tolerance of Various Implant Systems and their Components (치과용 임플란트 시스템의 기계적 가공오차에 관한 연구)

  • Kim, Hyeong-Seob;Kwon, Kung-Rock;Han, Jung-Suk
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.1
    • /
    • pp.57-65
    • /
    • 2008
  • Purpose: Misfit of implant components was very important in terms of prosthodontics. they has been linked to prosthetic complications such as screw loosening and fracture. Although there are many results about rotational freedom or machining tolerance between fixture and abutments, the data about domestic implant systems are lacking. The aim of this in vitro study was to evaluate the rotational freedom of domestic external and internal connection implant systems between their fixtures/anlaogs and abutments comparing imported systems. Materials and Methods: Rotational freedom between abutments and fixtures/analogs was investigated by using digitalized rotational angle measuring device. (1) 1 domestic external connection system(Neobiotec) and 2 imported external connection systems(Nobel Biocare, Anthorgyr), (2) 1 domestic internal connection system(Dentium) and 4 imported external connection systems(Nobel Biocare, Anthorgyr, Straumann, Frident Dentsply), and (3) 1 domestic zirconia external connection abutment(ZirAce) were evaluated. Each group has 3 samples. Mean values for each group were analyzed. Results: The differences relative to rotational freedom between domestic and imported implant systems were observed but domestic external connection implant system showed about 2.67 degrees(in case of fixture) and internal connection system showed about 4.3 degrees(in case of fixture). Domestic zirconia abutment showed less than 3 degrees of rotational freedom in a situation where the abutment was connected to an implant fixture egardless of domestic or imported systems. Conclusion: Newly developed digitalized rotational angle measuring device has high measuring resolution. The rotational freedom of domestic implant systems were similar to imported implant systems.

Detorque Values of Various Compatible Dental Implant Screws (호환 가능한 수종의 치과용 임플란트 나사의 풀림토크값에 대한 연구)

  • Lee, Ju-Ri;Lee, Dong-Hwan;Hwang, Jae-Woong;Choi, Jung-Han
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.3
    • /
    • pp.273-283
    • /
    • 2010
  • This study evaluated the effect of 3 different compatible screws on the detorque values in a multiple implant-supported superstructure and single implant abutments. An implant superstructure directly connected to 4 implants was screwed to 6 experimental dental stone casts made by acrylic resin splinted impressions, using 20 Ncm. The detorque values of screws were measured twice. Three compatible abutment screws used in this study were TorqTite screw, Gold-Tite screw, and, Titanium screw. And, using single implant abutments (GoldAdapt Engaging abutments), the detorque values of 3 different screws were measured twice on 2 implants of 5 experimental casts. According to statistical analysis of detorque values using mixed model at a .05 level of significance, no statistically significant differences among 3 different compatible screws were found in a multiple implant-supported superstructure (p>0.05). But, in single implant abutments, statistically significant differences among 3 different compatible screws were found (p=0.0175). The detorque values of TorqTite(p=0.0462) and Titanium(p=0.0348) screws were significantly higher than those of Gold-Tite screw, but no statisticantly significantlydifferences were found between TorqTite and Titanium screws(p>0.05). Therefore, various compatible screws showed significant effects on the detorque values for single implant abutment, but, showed no significant effects for a multiple implant-supported superstructure.

Effects of Coronal Thread Pitch in Scalloped Implant with 2 Different Connections on Loading Stress using 3 Dimensional Finite Element Analysis (연결부 형태가 다른 두 가지 scallop 임플란트에서 경부 나사선 피치가 응력 분포에 미치는 영향 : 삼차원적유한요소분석)

  • Choi, Kyung-Soo;Park, Seong-Hun;Lee, Jae-Hoon;Huh, Jung-Bo;Yun, Mi-Jung;Jeon, Young-Chan;Jeong, Chang-Mo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.2
    • /
    • pp.111-118
    • /
    • 2013
  • Purpose of present study is to investigate the effects of thread pitch in coronal portion in scalloped implant with 2 different connections on loading stress using 3 dimensional finite element analysis. Scalloped implant with 4 different thread pitches (0.4mm, 0.5mm, 0.6, and 0.7mm) in the coronal part was modeled with 2 different implant-abutment connections. Platform matching connection had the same implant and abutment diameter so that they were in flush contact at the periphery while platform mismatching connection had smaller abutment diameter than implant so that their connection was made away from periphery of implant-bone interface. Occlusal loading of 100N force was applied vertically and 30 degree obliquely to all 8 models and the maximum von Mises bone stress was identified. Loading stress as highly concentrated in cortical bone. Platform mismatching scalloped implant with small thread pitch (0.4mm) model had consistently lowest maximum von Mises bone stress in vertical and oblique loads. Platform matching model had lowest maximum von Mises bone stress with 0.6mm thread pitch in vertical load and with 0.4mm thread pitch in oblique load. Platform mismatching connection had important roles in reducing maximum von Mises bone stress. Scalloped implant with smaller coronal thread pitch showed trend of reducing maximum von Mises bone stress under load.

Conversion of implant overdenture to an implant assisted removable partial denture in maxilla: case report (상악 임플란트 피개의치에서 임플란트 보조 국소의치로의 전환: 증례보고)

  • Seong-Soo Cho;Min-Gyu Song;Yoon-Hyuk Huh;Chan-Jin Park;Lee-Ra Cho;Kyung-Ho Ko
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.1
    • /
    • pp.54-63
    • /
    • 2024
  • The long-term use of an implant overdenture shows problems, such as wear of attachment, concentrated occlusal forces on the anterior teeth, fracture of artificial teeth and rotation of denture. By transitioning to an Implant-assisted removable partial denture (IARPD) using additional implant placement, the problems can be solved. In this case report, a transition was made from implant overdenture to IARPD utilizing surveyed crowns to distribute occlusal forces concentrated on anterior teeth and to prevent denture rotation in a skeletal Class III patient. Design of definitive prosthesis with appropriate function and aesthetics was determined through several stages of provisional restorations. In this case, appropriate posterior occlusion and maintenance of peri-implant bone level of definitive prosthesis were observed.