• Title/Summary/Keyword: implant failure

Search Result 305, Processing Time 0.019 seconds

Prognosis following dental implant treatment under general anesthesia in patients with special needs

  • Kim, Il-hyung;Kuk, Tae Seong;Park, Sang Yoon;Choi, Yong-suk;Kim, Hyun Jeong;Seo, Kwang-Suk
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.17 no.3
    • /
    • pp.205-213
    • /
    • 2017
  • Background: This study retrospectively investigated outcomes following dental implantation in patients with special needs who required general anesthesia to enable treatment. Method: Patients underwent implant treatment under general anesthesia at the Clinic for the Disabled in Seoul National University Dental Hospital between January 2004 and June 2017. The study analyzed medical records and radiographs. Implant survival rates were calculated by applying criteria for success or failure. Results: Of 19 patients in the study, 8 were males and 11 were females, with a mean age of 32.9 years. The patients included 11 with mental retardation, 3 with autism, 2 with cerebral palsy, 2 with schizophrenia, and 1 with a brain disorder; 2 patients also had seizure disorders. All were incapable of oral self-care due to serious cognitive impairment and could not cooperate with normal dental treatment. A total of 27 rounds of general anesthesia and 1 round of intravenous sedation were performed for implant surgery. Implant placement was performed in 3 patients whose prosthesis records could not be found, while 3 other patients had less than 1 year of follow-up after prosthetic treatment. When the criteria for implant success or failure were applied in 13 remaining patients, 3 implant failures occurred in 59 total treatments. The cumulative survival rate of implants over an average of 43.3 months (15-116 months) was 94.9%. Conclusion: For patients with severe cognitive impairment who are incapable of oral self-care, implant treatment under general anesthesia showed a favorable prognosis.

Long-term Follow-up Results of Short-segment Posterior Screw Fixation for Thoracolumbar Burst Fractures

  • Lee, Yoon-Soo;Sung, Joo-Kyung
    • Journal of Korean Neurosurgical Society
    • /
    • v.37 no.6
    • /
    • pp.416-421
    • /
    • 2005
  • Objective: Despite general agreement on the goals of surgical treatment in thoracolumbar burst fractures, considerable controversy exists regarding the choice of operative techniques. This study is to evaluate the efficacy of short-segment fixation for thoracolumbar burst fractures after long-term follow-up and to analyze the causes of treatment failures. Methods: 48 out of 60 patients who underwent short-segment fixation for thoracolumbar burst fractures between January 1999 and October 2002 were enrolled in this study. Their neurological status, radiological images, and hospital records were retrospectively reviewed. Simple radiographs were evaluated to calculate kyphotic angles and percentages of anterior body compression (%ABC). Results: The average kyphotic angles were $20.0^{\circ}$ preoperatively, $9.6^{\circ}$ postoperatively, and $13.1^{\circ}$ at the latest follow-up. The average %ABC were 47.3% preoperatively, 31.2% postoperatively, and 33.3% at the latest follow-up. The treatment failure, defined as correction loss by $10^{\circ}$ or more or implant failure, was detected in 6 patients (12.5%). 5 out of 6 patients had implant failures. 2 out of 5 patients were related with osteoporosis, and the other 2 were related with poor compliance of spinal bracing. 3 patients with poor initial postoperative alignment had implant failure. 4 patients with screws only on the adjacent vertebrae and not on the injured vertebra itself showed poor initial and overall correction. Conclusion: With proper patient selection, adequate intraoperative reduction with screw fixation involving the injured vertebra, and strict postoperative spinal bracing, the short-segment fixation is an efficient and safe method in the treatment of thoracolumbar burst fracture.

A STUDY ON FAILURE STRENGTH OF THE IMPLANT PROSTHESIS LUTED WITH RESIN CEMENT BETWEEN GOLD CYLINDER AND SUPERSTRUCTURE (상부구조물과 금원주를 레진시멘트로 접착시킨 임프란트 보철물의 파절에 대한 연구)

  • Kim, Seung-Beom;Bae, Jeong-Sik
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.3
    • /
    • pp.438-447
    • /
    • 1996
  • This study was performed to determine the failure strength and pattern of implant prosthesis luted with resin cement between gold cylinder and superstructure, and to evaluate the bonding strength of resin cement. To evaluate failure strength and pattern, the groups were divided into 2. Group 1 : Casted gold cylinder Group 2 : Luted with resin cement between gold cylinder ans superstructure. To evaluate effects of the bonding strength of the implant prosthesis luted with resin cement according to storage condition, the groups were divided into 3 : Group A : Stored in waste at $37^{\circ}C$ for 24 hours. Group B : 1000 cycles thermocycled between $5^{\circ}C\;and\;55^{\circ}C$ in water. Group C : Stored in water at $37^{\circ}C$ for 30 days. The results were as follows. 1. Failure was found at gold screw in all specimens of group 1 & 2. 2. The bond strength in group 1 and 2 was 189.86 and 188.14kgf. There was no statistically significant difference between group 1 and 2(P>0.05). 3. The bond strength of group A, B and C was 53.28, 45,86 and 39.29Kgf. There result suggest the advantage of an improved fit of superstructure to the abutment and a simple procedure. But there was a measurable decrease of the bond strength according to storage condition. So, Further research is necessary to evaluate of the implant prosthesis luted with resin cement between gold cylinder and superstructure.

  • PDF

Fractures of implant fixtures: a retrospective clinical study

  • Yu, Han-Chang;Kim, Young-Kyun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.42
    • /
    • pp.13.1-13.6
    • /
    • 2020
  • Background: The aim of this study was to evaluate the factors that may affect implant fixture fractures. Methods: Patients who experienced implant fixture removal at Seoul National University Bundang Hospital from 2007 to 2015 due to implant fixture fracture were included. Implant/crown ratio, time of implant fracture, clinical symptoms before implant fracture, treatment of fractured implants, and the success and survival rate of the replaced implants were evaluated retrospectively. Results: Thirteen implants were fractured in 12 patients. Patient mean age at the time of fracture was 59.3 years. Of the 13 implants, 7 implants were placed at our hospital, and 6 were placed at a local clinic. The mean crown/implant ratio was 0.83:1. The clinical symptoms before fracture were screw loosening in five implants, marginal bone loss in five implants, and the presence of peri-implant diseases in five implants. All the fractured implants were removed, and 12 out of the 13 sites were re-implanted. Parafunctions were observed in two patients: one with bruxism and one with attrition due to a strong chewing habit. Conclusions: Several clinical symptoms before the fracture of an implant can predict implant fixture failure. Therefore, if these clinical symptoms are observed, appropriate treatments can be taken before more serious complications result.

The relationships between panoramic indices and dental implant failure (파노라마방사선사진 지수와 임플란트 실패와의 관계에 관한 연구)

  • Cho Hyun-Jung;Yi Won-Jin;Heo Min-Suk;An Chang-Hyeon;Lee Jin-Koo;Lee Sam-Sun;Choi Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.34 no.1
    • /
    • pp.25-30
    • /
    • 2004
  • Purpose: Several panoramic indices have been suggested to assess bone quality from the morphology and width of mandibular cortex on panoramic radiography. The purpose of this study was to compare dental implant failure group with control group in panoramic mandibular index (PMI), mandibular cortical index (MCI), and gonion index (GI) and to determine the effect of these panoramic indices on dental implant failure. Materials and Methods: A case-control study was designed. Test group (n=42) consisted of the patients who had their implants extracted because of peri-implantitis. Control group (n=139) consisted of the patients who retained their implants over one year without any pathologic changes and had been followed up periodically. They had dental implants installed in their mandibles without bone augmentation surgery from 1991 to 2001. The following measures were collected for each patients: 1) PMI, MCI, and GI were measured twice at one-week interval on preoperative panoramic views; and 2) age, sex, implant length, implant type, installed location, occluding dentition state, and complication were investigated from the chart record. Results: The PMI showed moderate level of repeatability. The intra-observer agreement of MCI and GI were good. There was statistically significant difference in PMI between two groups. There were significant different patterns of distribution of MCI and GI between two groups. Among the panoramic indices, PMI and MCI showed significant correlation with dental implant failure. Conclusion: Panoramic indices can be used as reference data in estimating bone quality of edentulous patients who are to have implants installed in their mandibles.

  • PDF

Analysis on cause of failure of guided bone regeneration during implant placement : A retrospective study (임플란트 시술 시 GBR의 실패 원인분석에 관한 후향적 연구)

  • Ko, Sun-Young;Oh, Jun-Ho;Lee, Seung-Jae;Kim, Hyung-Seop
    • Journal of Periodontal and Implant Science
    • /
    • v.38 no.3
    • /
    • pp.535-542
    • /
    • 2008
  • Purpose: The aim of this retrospective study is to evaluate survival rate of implant and bone formation, to analyze failure contribution factor. Material and Methods: A total of 52 consecutive patients(35 male, 17 female, mean age 49 years) with 104 osseous defects were treated during the period from October 2004 to June 2007 with a simultaneous or staged GBR approach using non-resorbable or resorbable membranes combined with autogenous bone grafts or xenograft(Bio-Oss, Bio-cera, BBP). Result: A total of 32(30,8%) of 104 GBR-treated sites failed the bone formation and a total of 5(5.6%) of 89 implants were removed. Early exposure of the membrane has significantly affected bone formation(p<0.05). Non-resorbable membrane showed more exposure of the membrane and low success rate of bone formation than resorbable membrane(p<0.05). There were no difference between success rate of bone formation and using autogenous bone or graft materials. There were no statistically significant difference between success rate of bone formation and smoking or using PRP. Mandible showed more success rate of bone formation than maxilla(p<0.05). Conclusion: Early exposure of the membrane, membrane type and maxilla/mandible type have influence on success rate of bone formation during GBR.

A retrospective study of the long-term survival of RESTORE® dental implants with resorbable blast media surface

  • Keun-Soo Ryoo;Pil-Jong Kim;Sungtae Kim;Young-Dan Cho;Young Ku
    • Journal of Periodontal and Implant Science
    • /
    • v.53 no.6
    • /
    • pp.444-452
    • /
    • 2023
  • Purpose: The aim of this study was to retrospectively evaluate the survival and failure rates of RESTORE® implants over a follow-up period of 10-15 years at a university dental hospital and to investigate the factors affecting the survival rate of these dental implants. Methods: A total of 247 RESTORE® dental implants with a resorbable blast media (RBM) surface inserted in 86 patients between March 2006 and April 2011 at the Department of Periodontology of Seoul National University Dental Hospital were included. Patients with follow-up periods of less than 10 years were excluded, and data analysis was conducted based on dental records and radiographs. Results: Over a 10- to 15-year period, the cumulative survival rate of the implants was 92.5%. Seventeen implants (6.88%) were explanted due to implant fracture (n=10, 4.05%), peri-implantitis (n=6, 2.43%), and screw fracture (n=1, 0.4%). The results of univariate regression analysis using a Cox proportional hazards model demonstrated that implants placed in male patients (hazard ratio [HR], 4.542; 95% confidence interval [CI], 1.305-15.807; P=0.017) and implants that supported removable prostheses (HR, 15.498; 95% CI, 3.105-77.357; P=0.001) showed statistically significant associations with implant failure. Conclusions: Within the limitations of this retrospective study, the RESTORE® dental implant with an RBM surface has a favorable survival rate with stable clinical outcomes.

Implant failure associated with oral bisphosphonate-related osteonecrosis of the jaw

  • Shin, Eun-Young;Kwon, Young-Hyuk;Herr, Yeek;Shin, Seung-Il;Chung, Jong-Hyuk
    • Journal of Periodontal and Implant Science
    • /
    • v.40 no.2
    • /
    • pp.90-95
    • /
    • 2010
  • Purpose: The aim of this study is to report a case of oral bisphosphonate-related osteonecrosis of the jaw (BRONJ) resulting in implant failure. Methods: A patient suspected of having BRONJ was referred to the Department of Periodontology, Kyung Hee University School of Dentistry for the evaluation and treatment of exposed bone around implants. Results: The patient, who had been taking oral bisphosphonates (BPs) for about a year, was successfully treated with systemic antibiotics, chlorhexidine mouth rinse, explantation, and surgical debridement of necrotic bone. Conclusions: The results of this case suggest that a patient taking BPs orally should be treated cautiously. Appropriate management including cessation of BPs and respective dental treatment may reduce the development of BRONJ.

Pseudotumor and Subsequent Implant Loosening as a Complication of Revision Total Hip Arthroplasty with Ceramic-on-Metal Bearing: A Case Report

  • Naik, Lokesh Gudda;Shon, Won Yong;Clarke, I.C.;Moon, Jun-Gyu;Mukund, Piyush;Kim, Sang-Min
    • Hip & pelvis
    • /
    • v.30 no.4
    • /
    • pp.276-281
    • /
    • 2018
  • Pseudotumors are not uncommon complications after total hip arthroplasty (THA) and may occur due to differences in bearing surfaces of the head and the liner ranging from soft to hard articulation. The most common causes of pseudotumors are foreign-body reaction, hypersensitivity and wear debris. The spectrum of pseudotumor presentation following THA varies greatly-from completely asymptomatic to clear implant failure. We report a case of pseudo-tumor formation with acetabular cup aseptic loosening after revision ceramic-on-metal hip arthroplasty. The patient described herein underwent pseudotumor excision and re-revision complex arthroplasty using a trabecular metal shell and buttress with ceramic-on-polyethylene THA. Surgeons should be aware of the possibility of a pseudotumor when dealing with revisions to help prevent rapid progression of cup loosening and implant failure, and should intervene early to avoid complex arthroplasty procedures.