References
- Blashi TJ (1996) An analysis and management of fractured implants: a clinical report. Int J Oral Maxillofac Implants 11:660-666
- Rangert B, Krogh PH, Langer B, Roekel NV (1995) Bending overload and implant fracture: a retrospective analysis. Int J Oral Maxillofac Implants 10: 326-334
- Kim YK, Kim SG, Yun PY, Hwang JW, Son MK (2010) Prognosis of single molar implants: a retrospective study. Int J Periodontics Restorative Dent 30(4):401-407
- Patterson EA, Johns RB (1992) Theoretical analysis of the fatigue life of fixture screws in osseointegrated dental implants. Int J Oral Maxillofac Implants 7:26-33
- Higuchi KW, Tiddo F (1995) Implant survival rates in partially edentulous patients: a 3-year prospective multicenter study. J Oral Maxillofac Surgery 53(3):264-268
- Eckert SE, Meraw SJ, Cal E, Ow R (2000) Analysis of incidence and associated factors with fractured implants: a retrospective study. Int J Oral Maxillofac Implants 15:662-667
- Chrcanovic BR, Kisch J, Albrektsson T, Wennerberg A (2018) Factors influencing the fractures of dental implants. Clin Implant Dent Relat Res 20(1):58-67. https://doi.org/10.1111/cid.12572
- Stoichkov B, Kirov D (2018) Analysis of the causes of dental implant fracture: a retrospective clinical study. Quintessence Int 49(4):279-286. https://doi.org/10.3290/j.qi.a39846
- Chitumalla R, Halini Kumari KV, Mohapatra A, Parihar AS, Anand KS, Katragadda P (2018) Assessment of survival rate of dental implants in patients with bruxism: a 5-year retrospective study. Contemp Clin Dent 9(Suppl2):S278-S282. https://doi.org/10.4103/ccd.ccd_258_18
- Piqozzi LB, Rehm DDS, Faqondes SC, Pellizzer EP, Grossi ML (2019) Current methods of bruxism diagnosis: a short communication. Int J Prosthodont 32(3):263-264. https://doi.org/10.11607/ijp.6196
- Okura K, Shigemoto S, Suzuki Y, Noguchi N, Omoto K, Abe S, Matsuka Y (2017) Mandibular movement during sleep bruxism associated with current tooth attrition. J Prosthodont Res 61(1):87-95. https://doi.org/10.1016/j.jpor.2016.06.003
- Al-Dwairi ZN, Al-Dagag ANF, Kielbassa AM, Lynch E (2017) Association between oral tori, occlusal force, and mandibular cortical index. Quintessence Int 48(10):841-849. https://doi.org/10.3290/j.qi.a38856
- Gholampour S, Gholampour H, Khanmohammadi H (2019) Finite element analysis of occlusal splint therapy in patients with bruxism. BMC Oral Health 19(1):205. https://doi.org/10.1186/s12903-019-0897-z
- Kumar A, Spivakovsky S (2018) Bruxism- is botulinum toxin an effective treatment? Evid Based Dent 19(2):59. https://doi.org/10.1038/sj.ebd.6401311
- Shemtov-Yona K, Rittel D, Levin L, Machtei EE (2014) Effect of dental implant diameter on fatigue performance. Part 1: mechanical behavior. Clin Impalnt Dent Relat Res 16:172-177
- Freitas-Junior AC, Bonfante EA, Martins LM, Silva NR, Marotta L, Coelho PG (2011) Effect of implant diameter on reliability and failure modes of molar crowns. Int J Prosthodont 24:557-561
- Moris IC, Faria AC, de Mattos MG, Ribeiro RF, Rodrigues RC (2012) Mechanical analysis of conventional and small diameter cornical implant abutments. J Adv Prosthodont 4:158-161
- Tabrizi R, Behnia H, Taherian S, Hesami N (2017) What are the incidence and factors associated with implant fracture? J Oral Maxillofac Surg 75(9):1866-1872. https://doi.org/10.1016/j.joms.2017.05.014
- Siddiqui AA, Caudill R (1994) Proceedings of the 4th international symposium on implant dentistry. J Prosthet Dent 72:623-634
- Gargallo Albiol J, Satorres-Nieto M, Puyuelo Capablo JL, Sanchez Garces MA, Pi Urgell J, Gay Escoda C (2008) Endosseous dental implant fractures: an analysis of 21 cases. Med Oral Patol Oral Cir Bucal 1 13(2):E124-E128
- Lee DW, Kim NH, Lee Y, Oh YA, Lee JH, You HK (2019) Implant fracture failure rate and potential associated risk indicators: An up to 12-year retrospective study of implants in 5,124 patients. Clin Oral Implant Res 30(3): 206-217
- Kim JS, Choi BR, Na YC (2012) Fracture of dental implants: case report. Journal of Dental Implant Research 31(3):84-87
- Morgan MJ, James DF, Pillar RM (1993) Fractures of the fixture component of an osseointegrated implant. Int J Oral Maxillofac Implants 8:409-414
- Koller CD, Pereira-Cenci T, Boscato N (2016) Parameters associated with marginal bone loss around implant after prosthetic loading. Braz Dent J 27(3):292-297. https://doi.org/10.1590/0103-6440201600874
- Hsu YT, Fu JH, Al-Hezaimi K, Wang HL (2012) Biomechanical implant treatment complications: a systematic review of clinical studies of implants with at least 1 year of functional loading. Int J Oral Maxillofac Implants 27(4):894-904
- Yi Y, Koak JY, Kim SK, Lee SJ, Heo SJ (2018) Comparison of implant component fractures in external and internal type: A 12-year retrospective study. J Adv Prosthodont Apr 10(2):155-162. https://doi.org/10.4047/jap.2018.10.2.155
Cited by
- Implant complications in bruxism patients vol.47, pp.2, 2020, https://doi.org/10.5125/jkaoms.2021.47.2.149
- Microstructural Analysis of Fractured Orthopedic Implants vol.14, pp.9, 2020, https://doi.org/10.3390/ma14092209