• Title/Summary/Keyword: impedance characteristics

Search Result 1,741, Processing Time 0.029 seconds

Humidity Sensitive Characteristics of CaTiO3 Thin Films (CaTiO3 박막의 감습특성)

  • Yook, Jae-Ho
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.62 no.2
    • /
    • pp.95-97
    • /
    • 2013
  • $CaTiO_3$ thin films using silk screen printing technology were fabricated and their humidity sensitive characteristics have been investigated. The specimens were sintered at $1000^{\circ}C$, $1050^{\circ}C$, $1100^{\circ}C$ for 1 hour and the best humidity sensitivity was shown in the specimens sintered at $1000^{\circ}C$. The humidity sensitivity decreased with increasing measuring frequencies and was stable at different abient temperatures. Hysteresis of impedance variation with increasing and decreasing relative humidity were negligible.

A Study on the Humidity Sensitive Characteristics of Perovskite-type Oxides Containing Alkaline Earth Ions (알칼리토족 이온을 함유한 페로브스카이트형 산화물의 감습특성에 관한 연구)

  • Yuk, J.H.;Lee, N.H.;Kang, D.H.;Han, S.O.;Park, K.H.;Lee, D.C.
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.737-739
    • /
    • 1992
  • The microstructure and humidity sensitive characteristics of $V_2O_5$ doped $CaTiO_3$ were studied. Sensing elements were prepared in bulk form. This element exhibits a porous structure. The grain grows and electrical conductivity increases as doping amount of $V_2O_5$ increases. The change of impedance and capacitance under different r.h is remarkable, and the conduction carriers of this element were ions.

  • PDF

An Antenna with Combination of Electric-Magnetic Radiators for NotePC Platform (전기-자기계 방사체 결합형 노트 PC용 안테나)

  • Kim, Yong-Jin;Kim, Jin-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.1
    • /
    • pp.24-28
    • /
    • 2010
  • This paper is presented on the antenna design for notepc platform. We present the antenna with combination of electric-magnetic radiator for dual-band Wireless Local Area Network (WLAN) service and a High Speed Downlink Packet Access (HSDPA) service. Due to the limited antenna space in notepc platform, the antennas for various wireless communication service should be located at a very small area. In this paper, the magnetic-type radiator works for high frequency band (1.7 - 2.1 GHz) application and the electric-type radiator works for low frequency band (820 - 960 MHz) application. This combination produces wide-band characteristics in the high frequency band. Simulation and experimental results of input impedance and gain characteristics of the proposed antenna are presented. There are good agreements between the simulated and measured S11 and gain values.

Development and/or Characteristics Evaluation of High Performance SPD(Surge Protective Device) (고성능 서지보호 시스템 개발 및 성능 평가)

  • Kim, Jae-Hoon;Kim, Ju-Han;Han, Sang-Ok;Kim, Sun-Ho;Koo, Kyung-Wan
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.3
    • /
    • pp.328-333
    • /
    • 2009
  • In this paper, we have developed high performance SPD(surge protective device) and evaluated the characteristics in comparison with typical SPD used in the inside and outside of the country. The new SPD was composed of MOV(metal oxide varistor), GDT(gas discharge tube) and impedance such as resistors, capacitors or varistors. To estimate operating the characteristic of the SPD which was developed, it was measured surge voltage caused by fault current or surge according to IEC 61000-4-5. As a result it was found that the power supply was cut off by high performance SPD when caused a short-circuit. In addition we could know that it could prevent ELB(earth leakage breaker)'s malfunction caused by surge.

The Propagation Characteristics of the Pressure in the Volume Loaded Fluid Transmission Line (체적부하를 갖는 유체 전달관로의 압력전파 특성)

  • 윤선주;손병진
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.11
    • /
    • pp.3075-3083
    • /
    • 1994
  • The applications of the electrical transmission line theory to the pressure propagation characteristics in the volume loaded fluid transmission line with step and impulse input wave is demonstrated in this paper. The method is based on the premise that the time response is the inverse Fourier transform of frequency spectrum of the wave which spectrum is a product of frequency spectrum of input pressure wave and system transfer function. The frequency response and transient response of step and impulse input wave in the volume loaded fluid transmission line is analysed by the Laplace transform and inverse Laplace transform with FFT numerical algorithm. The numerical solution of the distributed friction model is compared with the average friction model and the infinite product model. And the result is showed that FFT method may have major advantages for the simulation of fluid circuitary.

Analysis of the Electric-field Characteristics of V/UHF Antennas Installed on a Shipboard (함정 탑재 V/UHF 안테나의 전계 특성 분석)

  • Lee, Jin-Ho;Kwon, Joon-Hyuck;Song, Ki-Hwan
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.11 no.6
    • /
    • pp.74-80
    • /
    • 2008
  • Analysis of the electromagnetic environment on topside of a ship is needed for optimal arrangement of all kinds of antennas to be installed on the shipboard in order to minimize the probability of EMI of equipment and subsystems in real ship after construction phase. In this paper we analyze the characteristics of electric-fields such as radiation patterns and near E-fields of V/UHF antennas installed on a shipboard. We compare simulated results with measurements on the real ship for near E-fields to verify the reliability of the computed electromagnetic environment. Although there are various factors causing errors such as cable loss and impedance mismatching etc. when measuring near E-field, both data show similar trends in the range of the acceptable tolerance.

Analysis of current characteristics of outage generator for microgrid in outage mode operation (마이크로그리드용 순간정전발생기의 순간정전모드 동작시 전류특성 해석)

  • Lee, Y.H.;Min, B.H.;Nho, E.C.;Kim, I.D.;Chun, T.W.;Kim, H.G.
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.130-132
    • /
    • 2008
  • This paper describes the current characteristics of outage generator for microgrid in outage mode operation. The outage can be generated with 3-phase voltage disturbance generator. The STS current becomes very huge during the first cycle of the outage, and the magnitude of the current depends on the time impedance, series transformer leakage inductance, interfacing reactor of PCS, and the maximum allowable PCS output current. The current and load voltage waveform are analysed through simulation.

  • PDF

Analysis on the Characteristics of Voltage Unbalance Factor by Load Variations (부하 변동에 의한 전압불평형율의 특성 해석)

  • Kim, Jong-Gyeum;Park, Young-Jeen;Lee, Eun-Woong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.54 no.1
    • /
    • pp.47-53
    • /
    • 2005
  • Most of the loads in industrial power distribution systems are balanced and connected to three power systems. However, in the user power distribution systems, most of the loads are single & three phase and unbalanced, generating voltage unbalance. Voltage unbalance factor is mainly affected by load system rather than stable power system. Unbalanced voltage will draw a highly unbalanced current. As a result, the three-phase currents may differ considerably, thus resulting in an increased temperature rise in the machine. This paper presents a scheme on the characteristics of voltage and current unbalance factor under the load variation at the three phase 4-wire system. Load unbalance factor is measured by the power quality measurement apparatus and compared by the current unbalance factor. Two methods are indicated similar results. The voltage unbalance factor of the three-phase 4-wire system is approved by the field measurement. Each phase has an impedance each other by the unbalanced operation pattern and give rise to voltage unbalance.

FEM analysis of Quartz oscillator considering dimensions of electrode (전극형상을 고려한 수정진동자 해석 기법 연구)

  • 박승배;김종정;이덕훈;김태성
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.543-546
    • /
    • 2001
  • So far, the design methods of quartz crystal resonator have been developed. Recently, as the electronic package and semiconductor modules become smaller, the need to minimize the sizes of crystal components grows larger. but Minimizing crystal plate sizes has limitations because its temperature-frequency characteristics is worse and unwanted resonances occur. so appropriate design of electrode size and crystal plates is necessary. In this palter, Two-dimensional governing equations for electroded piezoelectric crystal plates with general symmetry have been solved from deduced equations from three-dimensional equations of linear piezoelectricity in most cases. In practice, electroded piezoelectric crystal plates have three-dimensional geometry, so simplified 2-dimensional equations and 2-D modeling are insufficient for explaining its resonance modes and characteristics. So, three-dimensional FEM(finite element method) analysis is done and its effectiveness is verified from analyzing practical crystal resonator model.

  • PDF

Arc Fault Circuit Interrupter Design for Electrical Fire Protection (전기화재 방지를 위한 아크고장전류 차단기 설계)

  • Ban, Gi-Jong;Kim, Lark-Kyo
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.5
    • /
    • pp.220-225
    • /
    • 2006
  • Arc Fault Current is an electric discharge which is occurred in two opposite electrode. In this paper, AFCI(arc fault circuit interrupter) is designed for the interruption of arc fault current which is occurred in the local electric network. This arc is one of the main causes of electric fire. Arc fault in electrical network has the characteristics of low current, high impedance and high frequency. Conventional arc fault circuit interrupter does not have the arc current interrupt function. Hence, Arc current controller is designed for the interruption of arc fault current which has the modified arc characteristics.