• 제목/요약/키워드: impact sound insulation

검색결과 118건 처리시간 0.021초

완충재 적용에 따른 습식온돌의 구조안전성 평가를 위한 실험연구 (An Experimental Study on Structural Safety Assesment of Wet Type Floor Heating System with Insulation)

  • 안재원;전명훈;이범식;이도헌
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.287-290
    • /
    • 2005
  • Housing is demanded to convert simple dwelling space into delightful one by improving of standard of living by economic development It is interested in the impact noise of the apartment housing that is revised to housing construction criteria at 29 March 2005 and then regulated the level of floor impact noise by the rule. The plan, which is actively investigated by counterplan for the reduction of impact noise, is application of sound insulation. In generally, first target by using insulation is the reduction of floor thermal transmittance in floor heating system of apartment housing. It is recently proposed soft materials that reduce the impact noise. However, it is a fact that the application of soft sound insulation includes some problem about structural performance. In this study, we made wet-heating specimen with various sound insulations, and carried out structralexperiment for evaluating the structural safety of it.

  • PDF

바닥 슬라브의 가진 위치에 따른 차음성능에 관한 연구 (A Study on the Insulation Performance of Impact Sound Level by Striking Location of Floor Slab)

  • 송필동;박명길;함진식
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2003년도 정기총회 및 추계학술대회
    • /
    • pp.73-76
    • /
    • 2003
  • This paper is contents about method to measure interception performance of shock noise of floor slab of apartment house to be simple. In the case of interception performance of light floor impact sound level, according to measurement method, grade of sound insulation performance showed greatly differently. But, in the case of interception performance of heavy floor impact sound level, it was similar result in all measurement method. Therefore, use of simple method of measurement was examined by possible fact in case of interception performance of heavy floor impact sound level.

  • PDF

임피던스법을 이용한 공동주택 바닥 충격음 차음성능 예측방법에 관한 실험 적 연구(II) - 경량 표준충격원을 중심으로 - (An Experimental Study or the Prediction Method of Floor Impact Sound Insulation Performance in Apartment House Using Impedance Method(II))

  • 김재수;장길수;김선우
    • 소음진동
    • /
    • 제2권1호
    • /
    • pp.21-31
    • /
    • 1992
  • In the previous paper, we report a practical floor impact sound level prediction method for a heavyweight impact source(Tire), soft impact source such as children jumping and running. According to these results, the calculated value and the measured value correspond comparatively well, regardless of differences in the floor structures. And the floor impact sound for a heavyweight impact source, soft source was strongly influenced by structural factors such as floor slab stiffness and peripheral support conditions. But the floor impact sound for a light impact source (Tapping machine), hard impact source was influenced by resilient layers, composed of multi-layer in floor structures. Thus, In this paper, 4 actual floor structures, all with differing resilient layers, were calculated using impedance method. When these calculation values were compared with the measured values, approximately all the values fell with one rank of the sound insulation grade, reference curve(L curve) by the JIS standard. So, a sample of measured values and calculated values from floor structures is presented to show the accuracy and appropriateness of the impedance method in domestic.

  • PDF

공동주택의 바닥충격음 전달 특성 분석에 관한 연구 (A Study on the Analysis of Propagation Characteristics for Floor Impact Noise in Apartment Houses)

  • 석호태;조경재;차민철;제성호
    • 한국주거학회논문집
    • /
    • 제16권5호
    • /
    • pp.91-98
    • /
    • 2005
  • The purpose of this study is to analysis of propagation characteristics for floor impact noise in attendance upon investigating standard of insulation performance, measurement and evaluation, understanding characteristics of a measuring factor for floor impact noise in apartment houses. Four cases which was before occupied apartment in Daegu was selected for experiment. Floor impact noise of measurement and evaluation method which are specified in the Korea Standard 2810-1, 2810-2, 2863-1 and 2863-2 was selected for this study. As the result of this study, 1) Especially, there is not a difference for apartment size, but the apartment of 40py type is lower than 30py's about $1\~2\;dB$ for light-weighted and heavy weighted impact sound. 2) The floor impact sound insulation performance is similar about measurement location of the same floor structure. 3) The floor impact sound insulation performance is not a difference about the slab area.

공동주택 구조형태별 층간 공기전달음 차단 성능 (The Performance of Insulation of Noise by Air between Floors According to Structure Systems of Apartment)

  • 이병권
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.1152-1155
    • /
    • 2007
  • Lately concerns about structure have been increased by advantages of floor impact noise, poilitical induction and changeability. Hence, Flat Plate Structure has been constructed increasingly. This study shows the comparison of the performance of sound insulation of Flat Plate Structure System and the existing Wall Structure. For this study, taking the same level organization of Daelim Architectural Environmental Research Center, I found the performance of sound insulation between the upper and lower floors about Wall Structure and Flat Plate Structure. Consequently, the performance of sound insulation between upper and lower floors of Flat Plate Structure was 3-5dB higher was approximately 3-5dB higher than one of Wall Structure. Especially, the performance of sound insulation on the upper floor was 1-3dB higher than on the lower floor. In addition, as the result of comparing radiation sound which radiates from the wall of lower floors with each structure system, Flat Plate Structure was about 4dB higher with Rw than Wall Structure. As we see totally, the performance of sound insulation of Flat Plate Structure is highter than one of the Wall Structure. It is 3-5dB higher and the main reason for this result depends on the existence of the wall which can radiate sound and nonexistence.

  • PDF

거실평면형태에 따른 공동주택 바닥충격음 차음특성 변화에 관한 실험적 연구 (An Experimental Study on the Floor Impact Sound Insulation of Apartment depending on the Plane Shape of Living-Room)

  • 박현구;박찬웅;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.844-847
    • /
    • 2008
  • As customer's demands are varying, the type of floor plan of apartment is changed into expanded type with balcony unified to living room from general type with balcony separated from living room and so is changing the layout of L(living room), D(dining room) and K(kitchen). This study aims to examine how the type of floor plan of living room affects the floor impact sound insulation performance and to propose fundamental idea to floor plan layout of apartment in terms of floor impact sound reduction.

  • PDF

바닥 진동 거동 및 충격원 특성을 고려한 바닥 중량 충격음 평가방법 고찰 (Consideration on Rating Method for Heavy Impact Sound Taking Account of the Characteristics of Floor Vibration and Impact Sources)

  • 이민정;최현기
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제21권4호
    • /
    • pp.69-79
    • /
    • 2017
  • 표준 중량 충격원의 실제 충격원 재현성에 대한 논란이 있음에도 현재 기준에서는 뱅머신 방식만 사용하고 있다. 현행 기준의 평가방법 및 등급 기준이 충격원 특성을 고려하지 못하고 있어 충격원의 선택에 따라 바닥충격음 차단 성능 등급에 차이가 발생하기 때문이다. 본 연구는 충격원 특성 외에 바닥 진동 거동 특성을 함께 고려한 현행 기준의 바닥충격음 평가 방법 고찰을 목적으로 한다. 공동주택 mock-up 실험동에서 표준 중량 충격원과 실충격원에 대하여 바닥충격음을 측정하고 이를 이용하여 해외 평가 방법과 우리나라의 평가 방법을 비교 검토하였다. 또한 현행 바닥충격음 평가 기준의 대상 주파수 범위를 벗어나는 저주파수 대역의 음압레벨은 네텔란드의 저주파 소음 인지 곡선과 국내 연구자가 제안한 저주파 소음 기준안을 이용하여 평가하였다. 그 결과 기준 및 평가 산정 방법에 따라 성능 평가 결과가 상이하며, 바닥 진동의 지배 주파수 범위에서 모든 충격원에 대한 바닥충격음 가청 소음으로 인식하여 성가시게 느낄 가능성이 매우 크다. 현행 평가 기준의 단일수치 평가량 산정 방법은 충격원에 따라 상이한 음압레벨 스펙트럼 특성을 제대로 반영하지 못하며, 바닥의 진동 거동 지배 주파수를 포함하는 저주파수 대역의 음압레벨을 고려하지 않고 있어 바닥충격음에 대한 평가 결과와 사람의 인지 수준에 차이가 발생할 수 있다. 따라서 충격원에 따른 음압레벨의 스펙트럼 특성과 저주파수 대역의 음압레벨을 반영할 수 있도록 현행 기준의 평가 방법을 보완할 필요가 있다.

축소시편 실험을 통한 공기전달음 차단성능 분석 (Analysis of airborne sound insulation performance by the experiment using small size specimen)

  • 김항;박현구;구희모;김선우
    • KIEAE Journal
    • /
    • 제14권1호
    • /
    • pp.83-89
    • /
    • 2014
  • The residents' demand for the comfortable life is promoting development of wall and window which has high sound insulation performance. To develop wall system, various aspects should be considered on the environment, material, construction and structure. Especially focusing on the acoustical view, the economical solution is one of the most critical point. Recently the interest on the partition wall is being increased, because it is useful for the Rahmen type apartment which is considered as an alternative to reduce floor impact sound. This study examines simplified measurement method of airborne sound insulation applied small size specimen, in order to save money to be used for the standard specimen then to promote the development process. The results showed that the simplified method could be effective for the wall system the sound insulation performance upto Rw 50 dB, and for the judgement of rank order of sound insulation performance of the similar wall type while developing.

주택성능등급 인정 사례의 부문별 평가 결과 분석 (Analysis on Results evaluated by "Housing Performance Grading System" in Korea)

  • 이성옥
    • KIEAE Journal
    • /
    • 제10권6호
    • /
    • pp.55-66
    • /
    • 2010
  • The government is enacted "Housing Performance Grading Indication System" from qualitative housing supply policy and performance of housing under the background of looking for new plan to secure good housing stock and housing performance. This system consists of 5 main performance section, 14 performance categories and 20 detailed performance items. 5 main performance parts are sound insulation related grading(Light-weight impact sound insulation, heavy-weight floor impact sound insulation, noise emission in bathroom, airborne sound insulation for wall between units), Long-life housing related grading(flexibility, remodeling & maintenance, durability), environment related grading(landscape, indoor air quality and ventilation, energy performance), Living environment related grading(common resident facilities such as playground and consideration for the socially underprivileged such as the aged), Fire fire prevention grading(fire fire prevention). The purpose of this research is to analyze characteristics and assessment results of 20 detailed performance items on "Housing Performance Grading Indication System" which was enforced 240 cases from Jan 9th, 2006 to Sep 30th, 2010. The analysis of approval condition of detailed performance items will be important comments for understanding the current domestic level and development of technology.

바닥마감재에 의한 바닥충격음 차음특성 연구 (A Study on the Floor Impact Sound Insulation Characteristics of Floor Coverings)

  • 기노갑;권현종;송민정;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.682-686
    • /
    • 2002
  • It is increasing the interest on the comfortable dwelling environment, while sound Insulation performance of materials and elements used in building is falling down as they become thicker and lighter. Therefore, sound insulation performance in building has become the most important factor determining the level of housing, especially for apartment that has common wall and floor with next neighbors. This paper aims to experiment the sound insulation characteristics of floor coverings as their types and to analyse their noise reduction effect.

  • PDF