• Title/Summary/Keyword: imaging mode

Search Result 333, Processing Time 0.021 seconds

Effect of Non-perceptual Sensory Stimulation Intensity Using Transcutaneous Electrical Nerve Stimulation on Cerebral Blood Flow (경피신경전기자극기를 이용한 비지각적 감각자극 강도가 뇌혈류에 미치는 영향)

  • Ju-Yeon Jung;Chang-Ki Kang
    • Science of Emotion and Sensibility
    • /
    • v.27 no.2
    • /
    • pp.81-90
    • /
    • 2024
  • In this study, we aimed to determine the effect on cerebral blood vessels of various stimulus intensities using transcutaneous electrical nerve stimulation (TENS). In particular, we wanted to monitor changes in blood flow and structural changes in the blood vessels in the common carotid artery (CCA) through low-intensity electrical stimulation that can cause non-perceptual sensory stimulation. Twenty-four healthy adults in their 20s participated in this study. Three stimulus intensities (below the sensory threshold, at the sensory threshold, and above the sensory threshold) were applied in random order. Changes in blood flow velocity according to the intensity of TENS stimulus were measured by placing the Doppler ultrasound transducer 1 cm below the CCA bifurcation, and the vascular structure was measured using B-mode imaging. C-mode Doppler and B-mode images were acquired before, during, and after the intervention for each stimulus, and changes in blood pressure were measured in each session. As a result, it was confirmed that peak systolic velocity (PSV) decreased significantly after the intervention in non-perceived sensory stimulation below the threshold, compared to other thresholds (p = .008). In particular, the PSV decreased by 3.04% on average compared to before stimulation (p = .011). However, there was no significant change in the CCA diameters before and after stimulation at all intensities. It was found that short-term, non-perceptual sensory stimulation was effective in reducing the blood flow rate without causing significant changes in either the blood vessel diameter or blood pressure. This change appears to be caused by a decrease in blood flow due to the effect of subtle vasodilation at non-perceptual sensory stimulation, and at stimulation intensity higher than that, the sympathetic nerves in the blood vessels are stimulated excessively and the blood vessels constrict. Therefore, this study can be rated as an important attempt to control blood flow through stimulation without such a psychological burden and sensory discomfort in the carotid area.

The Output Characteristics of Transcranial Magnetic Stimulation with Voltage Variable Capacitor-Charging System

  • Kim, Whi-Young
    • Journal of information and communication convergence engineering
    • /
    • v.8 no.2
    • /
    • pp.205-211
    • /
    • 2010
  • In this study, a Magnetic stimulation Pulse Train control technique is introduced and applied to Flyback converter operating in discontinuous conduction mode. In contrast to the conventional pulse width modulation control scheme, the principal idea of a Magnetic stimulation Pulse Train is to achieve output voltage regulation using high and low power pulses. The proposed technique is applicable to any converter operating in discontinuous conduction. However, this work mainly focuses on Flyback topology. In this paper, the main mathematical concept of the new control algorithm is introduced and simulations as well as experimental results are presented.

Hypertrophic obstructive cardiomyopathy in a Yorkshire Terrier

  • Hwang, Taesung;Park, Junghyun;Jung, Dongin;Lee, Hee Chun
    • Korean Journal of Veterinary Research
    • /
    • v.58 no.3
    • /
    • pp.159-162
    • /
    • 2018
  • An 11-year-old, castrated male dog presented with a 3-month history of cough and depression. Auscultation revealed systolic murmur and thoracic radiographs showing enlargement of both the atrium and left ventricle. Echocardiography showed thickened mitral valve and moderate-to-severe left atrial enlargement. Additionally, M-mode echocardiography showed symmetric left ventricular wall thickening and systolic anterior motion of the mitral valve, while Doppler imaging revealed high velocity turbulent flow through the left ventricular outflow tract. Based on echocardiography, this case was diagnosed with hypertrophic obstructive cardiomyopathy. After 5 months, the dog was clinically static in radiography and echocardiography.

Focused Electron Beam-Controlled Graphene Field-Effect Transistor

  • Kim, Songkil
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.33 no.5
    • /
    • pp.360-366
    • /
    • 2020
  • Focused electron beams with high energy acceleration are versatile probes. Focused electron beams can be used for high-resolution imaging and multi-mode nanofabrication, in combination with, molecular precursor delivery, in an electron microscopy environment. A high degree of control with atomic-to-microscale resolution, a focused electron beam allows for precise engineering of a graphene-based field-effect transistor (FET). In this study, the effect of electron irradiation on a graphene FET was systematically investigated. A separate evaluation of the electron beam induced transport properties at the graphene channel and the graphene-metal contacts was conducted. This provided on-demand strategies for tuning transfer characteristics of graphene FETs by focused electron beam irradiation.

Ion Electrical and Optical Diagnostics of an Atmospheric Pressure Plasma Jet

  • Ha, Chang Seung;Shin, Jichul;Lee, Ho-Jun;Lee, Hae June
    • Applied Science and Convergence Technology
    • /
    • v.24 no.1
    • /
    • pp.16-21
    • /
    • 2015
  • The characteristics of an atmospheric pressure plasma jet (APPJ) in He discharge are measured with electrical and optical diagnostics methods. The discharge phenomenon in one cycle of the APPJ was diagnosed using intensified charge coupled device (ICCD) imaging. The gate mode images show that the propagation of plasma bullets happens only when the applied voltage on the inner conductor is positive. Moreover, the Schlieren image of the plasma jet shows that the laminar flow is changed into a turbulent flow when the plasma jet is turned on, especially when the gas flow rate increases.

High frequency VLBI imaging of OVV1633+382

  • Ro, Hyunwook;Sohn, Bong Won;Chung, Aeree;Krichbaum, Thomas
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.2
    • /
    • pp.62.2-62.2
    • /
    • 2014
  • A relativistic jet associated with active galactic nuclei (AGNs) is almost ubiquitous while its formation mechanism is still not well understood. To get a deeper understanding of how an AGN jet forms and evolves, we have obtained Very Large Baseline Array (VLBA) data of a compact and optically violent variable quasar, OVV 1633+382 which is a small line-of-sight angle version of Fanaroff-Reily type 2 galaxy. Before our data were taken, a pronounced flare had been reported at mm wavelengths, making this object an excellent laboratory to study detailed properties of a radio jet powered by an AGN. The target have been observed in 12 epochs between 2002 and 2005 at 22, 43 and 86 GHz in full polarization mode. Among these observations, in this work, we present 43 GHz total intensity maps of our target for three epochs to discuss kinematics and geometry of the jet.

  • PDF

A Bright H${\alpha}$ kernel Observed Using the FISS

  • Cho, Kyu-Hyoun;Chae, Jong-Chul;Lim, Eun-Kyung
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.1
    • /
    • pp.87.2-87.2
    • /
    • 2012
  • H${\alpha}$ transient bright kernels may be an important diagnostic of energy conversion processes occurring in the choromosphere during flares. We observed an H${\alpha}$ kernel that occurred in AR 11263 in associated with a small flare on 2011 Autust 5th using the Fast Imaging Solar Spectrograph installed at the 1.6m New Solar Telescope of Big Bear Solar Observatory. We find that both the H${\alpha}$ line and the CaII 8542${\AA}$ line appear in emission, with a red asymmetry in that they display red wings of enhanced emission. The red asymmetry shows 5-30 km/s downward motion for 8 minutes. We determine some physical parameters by adopting the Cloud mode and discuss the physical meaning of these results.

  • PDF

Combined BOLD fMRI and Transcranial Magnetic Stimulation Study: Evaluation of Ipsilateral Motor Pathway of Stroke Patients

  • 배성진;장용민;장성호;변우목;강덕식
    • Proceedings of the KSMRM Conference
    • /
    • 2001.11a
    • /
    • pp.104-104
    • /
    • 2001
  • Purpose: In this study, we investigated the possible motor pathways of hemiplegic stroke patients usin combined TMS and BOLD fMRI approach and evaluated the correlation between TMS a fMRI methods. Method: Four subjects, who demonstrated left hemiplegia after stroke, are included. TMS was performed using a Dantec Mag2 stimulator (Dantec Company, USA) in single puls mode with figure eight-shaped coil. Following TMS localization, The BOLD T2*-weight images were acquired with echo planar imaging sequence (TR = 1.2 sec, TE = 60 msec, and flip angle = 90). Motor activation was studied by means of a repetitive fing flexion-extension task. The stimulation protocol comprised 10 cycles of alternating activati and rest (10 images per cycle). Total 60 cycles were performed and each cycle take abou 1.5 sec. The resulting images were then analyzed with STIMULATE (CMRR, U, o Minnesota) to generate functional maps using a student t-test (p < 0.0005) and cluste analysis.

  • PDF

STM Study of Nb Clusters on Ag(110)

  • 윤홍식;이준희;양경득;여인환
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.173-173
    • /
    • 1999
  • The initial growth mode of Nb on Ag(110) in sub-monolayer region is studied using Scanning Tunneling microscopy. E-beam evaporated Nb is deposited onto the substrate at RT, and STM measurements are carried out at RT and 78K. With Nb being immiscible in bulk Ag, 3D islands formation begins at early stage and no particular ordered structure is found. At very low coverages, however, many interesting phenomena are observed in association with Nb clusters. Small Nb clusters as deposited displays very strong size dependence against atom-manipulation by the STM tip. In addition, the apparent corrugation of clusters below the critical size exhibits dramatic dependence on the imaging bias, disappearing completely over a wide range of the bias. Possible physical mechanism responsible for such behavior will be discussed.

  • PDF

Enhanced RGB Video Coding Based on Correlation in the Adjacent Block (인접블록의 상관관계에 기반한 RGB video coding 개선 알고리즘)

  • Kim, Yang-Soo;Jeong, Jin-Woo;Choe, Yoon-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.12
    • /
    • pp.2538-2541
    • /
    • 2009
  • H.264/AVC High 4:4:4 Intra/Predictive profiles supports RGB 4:4:4 sequences for high fidelity video. RGB color planes rather than YCbCr color planes are preferred by high-fidelity video applications such as digital cinema, medical imaging, and UHDTV. Several RGB coding tools have therefore been developed to improve the coding efficiency of RGB video. In this paper, we propose a new method to extract more accurate correlation parameters for inter-plane prediction. We use a searching method to determine the matched macroblock (MB) that has a similar inter-color relation to the current MB. Using this block, we can infer more accurate correlation parameters to predict chroma MB from luma MB. Our proposed inter-plane prediction mode shows an average bits saving of 15.6% and a PSNR increase of 0.99 dB compared with H.264 high4:4:4 intra-profile RGB coding. Furthermore, extensive performance evaluation revealed that our proposed algorithm has better coding efficiency than existing algorithms..