• 제목/요약/키워드: imaging mode

검색결과 336건 처리시간 0.023초

새로운 자기공명영상촬영용 Quadrature Breast RF 코일 (A New Quadrature Breast RF Coil for MRI)

  • 김선경;양윤정;이덕래;이윤;안창범;오창현
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 추계학술대회
    • /
    • pp.291-293
    • /
    • 1997
  • A new quadrature RF coil is designed for Breast MR Imaging. Quadrature RF coils for MRI have been useful to improve the signal-to-noise ratio (SNR) by "$\sqrt{2}$" using two orthogonal RF coils in combination. A modified Breast Quadrature coil is designed. It is a modified type of the high-pass birdcage coil. To reduce the field distortion, by using current feeding, the field pattern is optimized to achieve a quadrature circularly-polarized field pattern. The coil has been implemented for receive-only mode, and tested by phantom imaging. The experimental results show the utility of the proposed RF coil.

  • PDF

근적외선 펨토초 레이저 및 이광자 바이오 영상 기술 (Near Infrared Femtosecond Laser and Its Two-photon Bio-imaging Technology)

  • 송동훈;서홍석;이상균;허철;박수준
    • 전자통신동향분석
    • /
    • 제36권5호
    • /
    • pp.1-8
    • /
    • 2021
  • Over the last three decades, the development of Ti:sapphire femtosecond lasers has led to advancements in scientific and industrial fields. In particular, these advanced lasers show great potential for applications with bio-imaging and medical surgery, such as two-photon microscopy, nonlinear Raman microscopy, optical coherence tomography, and ophthalmic surgery. Herein, we present a detailed description of the theoretical and experimental physics of Kerr-lens mode-locked femtosecond Ti:sapphire lasers and its two-photon microscopy.

Cone beam형 전산화단층촬영에 의한 흡수선량 (Radiation absorbed doses of cone beam computed tomography)

  • 이의태;김규태;최용석;황의환
    • Imaging Science in Dentistry
    • /
    • 제37권2호
    • /
    • pp.87-92
    • /
    • 2007
  • Purpose: To measure the absorbed doses of cone beam computed tomography (CBCT), which is recently being more frequently used, and to compare them with those of panoramic radiography. Materials and Methods: To measure the absorbed doses of CBCT ($PSR-9000N^{TM}$, Asahi Roentgen Ind. Co., Japan), we placed TLD chips on the skin regions above the parotid and thyroid glands, and on the dorsum of tongue in a dental head phantom. We used two image acquisition modes of the Dental and Panoramic modes of CBCT, which differed in the field of view. Also, panoramic radiographs (Auto IIIN, Asahi Roentgen Ind. Co., Japan) were taken to compare with the absorbed doses of CBCT. Result: In the Dental mode of CBCT, the absorbed doses of the parotid gland, dorsum of tongue, and thyroid gland were 3.53, 3.13, and 0.36 mGy, respectively. In the Panoramic mode of CBCT, they were 9.57, 9.15, and 0.85 mGy, respectively. The panoramic mode showed higher absorbed doses than those of the Dental mode. In the panoramic radiography, the absorbed doses of the parotid gland, dorsum of tongue, and thyroid gland were 1.21, 1.19, and 0.16 mGy, respectively. And they were about 1/3 of the Dental mode and 1/9 of the Panoramic mode of CBCT. Conclusion: Absorbed doses of CBCT are higher than those of panoramic radiography, and dependent upon the field of view.

  • PDF

How to Detect Viscoelastic Properties of Polymeric Materials by Dynamic Atomic Force Microscopy

  • Nakajima, Ken;Fujinami, So;Nishi, Toshio
    • 한국고분자학회:학술대회논문집
    • /
    • 한국고분자학회 2006년도 IUPAC International Symposium on Advanced Polymers for Emerging Technologies
    • /
    • pp.346-346
    • /
    • 2006
  • Several types of dynamic atomic force microscopy such as tapping-mode, force modulation-mode are commonly cooperated by phase-contrast imaging techniques, which were interpreted as elastic contrast by mistake in the past and are nowadays regarded as the representation of energy dissipative processes. However, as theoretically reported, the situation is not so simple when the strong adhesive interaction is involved. Furthermore, elastic and viscous contributions are not easily divided in the case of polymeric systems. Thus, the interpretation of image contrast for them must be very carefully treated. In this study, we will demonstrate how such contrast mechanisms are complicated, using several miscible and immiscible polymer blend systems as model samples.

  • PDF

Stripmap-mode SAR에서의 영상복원 알고리즘의 성능분석 (Performance Analysis of the reconstruction Algorithms in the Stripmap-mode SAR)

  • 박현복;김형주;최정희
    • 한국전자파학회:학술대회논문집
    • /
    • 한국전자파학회 2000년도 종합학술발표회 논문집 Vol.10 No.1
    • /
    • pp.29-33
    • /
    • 2000
  • Stripmap SAR 시스템에서 레이더는 Slant range-domain에서 고정된 Strip상에 Data acquisition period 동안 계속해서 같은 Broadside 방사 패턴을 유지하며, Range domain에서 고정돈 Strip내의 지형의 지도를 제공하는 SAR 영상 시스템이다. Stripmap SAR를 위한 고전적인 영상 복원을 Synthetic aperture (slow-time) domain에서 Deramping 또는 Chirp deconvolution을 이용하는 Fresnel approximaptio에 의존하였다. 또 다른 Stripmap SAR 영상화의 접근방법으로 SAR wavefront reconstruction이론과 레이더 방사형태에 대한 spherical wave Fourier decomposition을 통하여 slow-time domain에서의 SAR 신호의 분석에 기본을 두고 있다. 본 논문에서는 컴퓨터 모의 실험을 통해 생성된 Stripmap SAR 데이터를 이용하여 Fresnel approximation 기법과 Wavefront Reconstruction 기법을 비교 분석한다.

  • PDF

HIGH QUALITY IMAGE ACQUSITION METHOD USING DUAL PANCHOMATIC CHANNEL

  • Chang, Young-Jun;Kim, Jung-Ah
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2007년도 Proceedings of ISRS 2007
    • /
    • pp.203-206
    • /
    • 2007
  • The Space-borne electro-optical camera system has panchromatic redundant image channel as well as primary channel in order to increase reliability of satellite system. In most case redundant channel never been used during the whole mission period. Staggered array configuration using redundant image channel and new operation mode proposed which operates primary and redundant channel simultaneously. Without new hardware design, fast electronics and system complexity, we can get 1.414 times more fine GSD image of original system or we can get 1.414 times more SNR or High dynamic range imaging mode. In this paper we deal with several image quality improvement methods using dual panchromatic channel.

  • PDF

고객 안전을 위한 디지털 방사선장치(DRF)의 투시영상기록장치 개발 (- Development of Digital Fluoroscopic Image Recording System for Customer Safety -)

  • 임재동;강경식
    • 대한안전경영과학회지
    • /
    • 제6권3호
    • /
    • pp.303-309
    • /
    • 2004
  • Many system devices for fluoroscopic and general X-ray studies in diagnostic radiographic system have been being changed from analog mode to digital mode. In addition, among diagnostic imaging and radiologic examinations, fluoroscopic studies that requires functional diagnosis is being widely used. The video recording method of fluoroscopic studies has been useful in functional image diagnosis and dynamic image observation, but the utility of its image quality is being reduced because of limitation in setting play segments of the video player, inconvenience of play, difficulties in preserving reproduced images, the change of image quality, etc. In order to complement these shortages, it is necessary to facilitate access to patient diagnosis information such as storing, editing and sharing functional diagnosis images in response to the trend of the digitalization of digital radiographic & fluoroscopic system(DRF). Thus this study designed and implemented a device of storing functional dynamic images real time using a computer rather than existing video recording, aiming at contribution to functional image diagnosis.

Low Loss Highly Birefringent Porous Core Fiber for Single Mode Terahertz Wave Guidance

  • Habib, Md. Ahasan;Anower, Md. Shamim
    • Current Optics and Photonics
    • /
    • 제2권3호
    • /
    • pp.215-220
    • /
    • 2018
  • A novel porous-core hexagonal lattice photonic crystal fiber (PCF) is designed and analyzed for efficient terahertz (THz) wave propagation. The finite element method based Comsol v4.2 software is used for numerical analysis of the proposed fiber. A perfectly matched layer boundary condition is used to characterize the guiding properties. Rectangular air-holes are used inside the core to introduce asymmetry for attaining high birefringence. By intentionally rotating the rectangular air holes of porous core structure, an ultrahigh birefringence of 0.045 and low effective material loss of $0.086cm^{-1}$ can be obtained at the operating frequency of 0.85 THz. Moreover, single-mode properties, power fraction in air core and confinement loss of the proposed PCF are also analyzed. This is expected to be useful for wideband imaging and telecom applications.

원자현미경(AFM)의 진동해석 (Vibration analysis of Atomic Force Microscopy)

  • 정희원;김수경;박건순;오형렬;김진용;신종엽;권대갑
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 추계학술대회논문집
    • /
    • pp.643-648
    • /
    • 2000
  • The AFM is an imaging tool or a profiler with unprecedented 3-D resolution for various surface types. The AFM technology, however, leaves a lot of room for improvement due to its delicate and fragile probing mechanism. The distance between probe tip and sample surface must be maintained in below the nano meter level in order to measure the sample surface in Angstrom resolution. In this paper, the mode analysis of AFM system, modification based on the mode analysis are performed and finally the sample surface is measured by the home-built AFM.

  • PDF

The Observational Evidence for the Internal Excitation of Umbral Velocity Oscillations

  • Cho, Kyuhyoun;Chae, Jounchul
    • 천문학회보
    • /
    • 제43권2호
    • /
    • pp.47.2-47.2
    • /
    • 2018
  • The umbral oscillations of velocity are commonly observed in the chromosphere of a sunspot. Their sources are considered to be either the external p-mode driving or the internal excitation by magnetoconvection. Even though the possibility of the p-mode driving has been often considered, the internal excitation has been rarely investigated. We report the observational evidence for the internal excitation obtained by analyzing velocity oscillations in the temperature minimum region of a sunspot umbra. The velocity oscillations in the temperature minimum region were determined from Fe I $5435{\AA}$ line data taken by the Fast Imaging Solar Spectrograph (FISS) of the 1.6 m Goode solar Telescope (GST) at the Big Bear Solar Observatory. As a result, we discovered 4 events of oscillations which appear to be internally excited. We analyze their characteristics and relation to photospheric features. Based on these results, we estimate the contribution of the internal excitation for umbral oscillations and discuss their importance.

  • PDF