• Title/Summary/Keyword: imaging material

Search Result 581, Processing Time 0.03 seconds

Effects of Cryosurgery in Primary Lung Cancer (원발성 폐암에서 냉동수술의 치료 효과)

  • Jung, Won-Jae;Kim, Kwang-Taik;Yi, Eun-Jue;Lee, Sung-Ho;Kang, Moon-Chul;Chung, Jae-Ho;Ham, Soo-Yeoun;Jo, Sung-Bum
    • Journal of Chest Surgery
    • /
    • v.42 no.2
    • /
    • pp.201-205
    • /
    • 2009
  • Background: Cryosurgery has been used to treat primary malignant pulmonary tumors at our institute since November 2004. In this study we analyzed our treatment results and complication rates. Material and Method: A retrospective study using medical charts and imaging data was conducted involving 17 patients with a total of 17 malignant pulmonary tumors who were treated between November 2004 and March 2007. Fourteen patients were males and 3 were females. The median age of the patients was 64 years (range, $54{\sim}77$ years). The average size of the tumors was 48.8mm (range, $36{\sim}111mm$) in diameter. The patients were followed with chest CT scans 7 days, 1 month, 3 months, and 6 months postoperatively. PET scans were obtained between 6 and 9 months postoperatively. The treatment response was analyzed according to the Response Evaluation Criteria in Solid Tumors (RECIST) criteria. Result: Six months after treatment, 6 tumors (35.3%) showed a complete response, 4 (23.5%) had a partial response, 3 (17.6%) had stable disease, and 4 (23.5%) showed disease progression. In tumors <4 cm in diameter, a complete response was reported in 50% of the tumors. A $x^2$-test showed that in tumors <4 cm in diameter, the p-value for results better than a partial response was 0.034. With respect to procedural complications, there was 1 case of blood-tinged sputum which resolved spontaneously within 1 or 2 days, a spontaneously relieved case of subcutaneous emphysema, and 1 patient with a fever. There were no mortalities and the average hospital stay was 6.3 days. Conclusion: The effects of cryosurgery on primary lung cancer is greatest in patients with small tumors. Considering the facts that cryosurgery is minimally invasive, has a low complication rate, and can be performed repetitively, we believe that it may play an important role in the treatment of high risk lung cancer patients.

The Short Term and Intermediate Term Results of using a T-tube in Patients with Tracheal Stenosis (기관 협착 환자에서의 T-튜브의 중단기 결과)

  • Sa, Young Jo;Moon, Seok-Whan;Kim, Young-Du;Jin, Ung;Park, Jae-Kil;Kim, Jae Jun;Kim, Chi-Kyung;Jo, Keon Hyon;Park, Chan Beom;Yim, Hyeon Woo
    • Journal of Chest Surgery
    • /
    • v.42 no.1
    • /
    • pp.63-71
    • /
    • 2009
  • Background: The treatment of tracheal stenosis includes less invasive bronchoscopic intervention and more invasive segmental resection & anastomosis. Depending on the patient's clinical features, sometimes all these methods are inappropriate. Silicone T-tube stenting has recently been used as an alternative, safe management of tracheal stenosis. We studied the short term and Intermediate term results of using T-tubes in patients with tracheal stenosis, and this tracheal stenosis was caused by various underlying diseases. Material and Method: We retrospectively reviewed 57 patients with tracheal stenosis and who were treated with T-tubes between Jan 1997 and Apr 2007. Based on the patient's medical records and the imaging studies, we evaluated the clinical findings and status of T-tube removal. Result: There was no T-tube related morbidity or mortality in this series. On follow-up, one patient underwent sleeve resection and end-to-end anastomosis. The T-tube could be successfully removed from 13 patients (13/57, 22.8%) without additional interventions. For another four patients, a T-tube was again inserted after removal of the first T-tube due to tracheomalacia or recurrent stenosis. Four patients died of underlying disease and cancer. The patients' gender and previous tracheostomy significantly affected T-tube removal. By contrast, multiple logistic regression analysis identified gender as a predictor of successfully removing a T-tube. Gender (p=0.033) and previous tracheostomy (p=0.036) were the two factors for success or failure of T-tube removal. Conclusion: A T-tube provided reliable patency of a stenotic airway that was caused by any etiology. We have proven that using a T-tube is safe and effective therapy for patients with tracheal stenosis for the short term or the intermediate term.

Correlation of Clinical Outcome and Cuff Integrity after Open Repair in Large and Massive Rotator Cuff Tears (대형 및 광범위 회전근 개 파열의 개방적 봉합술 후 임상적 결과와 회전근 개 연속성(integrity)의 상관 관계)

  • Noh, Haeng-Kee;Wang, Joon-Ho;Kim, Dong-Hwee;Park, Jong-Woong;Kim, Jae-Gyoon;Park, Jung-Ho
    • Clinics in Shoulder and Elbow
    • /
    • v.10 no.1
    • /
    • pp.65-72
    • /
    • 2007
  • Purpose: To evaluate the relationship between the clinical outcome and the cuff integrity following open repair in large and massive rotator cuff tears using ultrasonography as an imaging modality. Material and Methods: From November 2001 to April 2005, 17 cases(16 patients) who had open repair of tear measuring more than 3cm were assessed with minimal follow-up of 12 months in this study. 6 cases had a large tear and 11 cases a massive tear. There were 6 men and 11 women with a mean age of 52 years at surgery (range, 33 to 72 years). The evaluation consisted of the preoperative and postoperative shoulder scores according to UCLA shoulder scoring system and Visual analogue scale (VAS). Ultrasonography was performed by a experienced musculoskeletal physician at a minimum of 12 months postoperatively to evaluate the postoperative cuff integrity. Results: Retear were detected in four of seventeen cases. Regardless of the presence of recurrent tear, 14 cases had UCLA score of more than 29 points (good grade). All 17 had an improvement in the functional score, which increased from an average of 15.1 to 31.2 points. All cases showed pain relief and five cases had no pain. Sixteen cases except one had the range of motion of forward elevation above $90^{\circ}$. Conclusion: Open rotator cuff repair in large and massive tears showed low retear rate. At a minimum of twelve months follow-up, all cases had improvement on UCLA score, pain relief, increased range of motion of the shoulder regardless of retear. And the correlation between recurrent tear and function score was not statistically significant.

Clinical Usefulness of Chest Wall Ultrasonography for Detecting Fractures of Costal Cartilage due to Minor Blunt Chest Trauma (경미한 둔상에 의하여 야기되는 늑연골 골절 진단에 있어서 흉벽 초음파 검사의 임상적 유용성)

  • Lee, Woo-Surng;Kim, Yo-Han;Chee, Hyun-Keun;Hwang, Jae-Joon;Lee, Song-Am;Jung, Ho-Sung;Shin, Hyun-Joon;Choi, Young-Chill
    • Journal of Chest Surgery
    • /
    • v.42 no.4
    • /
    • pp.502-508
    • /
    • 2009
  • Background: Rib fractures are the most common injuries that are caused by blunt chest trauma. However, fractures of the costal cartilage generally go unnoticed on chest X-rays unless they involve a calcified cartilage. For this reason, the sensitivity of conventional radiography for detecting rib fractures is low, and especially those involving the cartilaginous part of the rib. Thus, we have evaluated the usefulness of ultrasonography for detecting fractures of the costal cartilage that were overlooked on the conventional radiographs of patients who suffered minor blunt chest traumas. Material and Method: A total of 45 patients who suffered minor blunt chest trauma and who had no evidence of rib fractures or other major fractures on conventional radiographs were admitted for ultrasonography between April 2008 and March 2009. There were 24 women and 21 men, and the mean age of the patients was 50.4$\pm$15.91 years (range: 17$\sim$76 years). They were examined for the detection of fractures of the costal cartilage by performing ultrasonography with a 7.5-MHz linear transducer. Result: A total of 30 patients (67%) had fractures of the costal cartilage, whereas 15 patients (33%) had no evidence of chondral rib fractures. The mean number of fracture sites of the fractured costal cartilage was 1.6$\pm$0.81 (range: 1$\sim$4 sites) in 30 patients. Periosteal hematoma was the most common finding associated with fractures of the costal cartilage (n=7, 17%), followed by sternum fracture (n=5, 12%). However, periosteal hematoma was noticed in 1 patient (2%) who was without fracture of the costal cartilage, and sternum fracture was noticed in 1 patient (2%) who was without fractures of the costal cartilage. Conclusion: The results of this study suggest that ultrasonography may be a useful imaging modality for detecting fractures of the costal cartilage that are overlooked on the conventional radiographs of patients who suffer minor blunt chest trauma.

Determination of Electron Spin Relaxation Time of the Gadolinium-Chealted MRI Contrast Agents by Using an X-band EPR Technique (EPR을 통한 상자성 자기공명 조영제의 전자스핀 이완시간의 결정)

  • Sung-wook Hong;Yongmin Chang;Moon-jung Hwang;Il-su Rhee;Duk-Sik Kang
    • Investigative Magnetic Resonance Imaging
    • /
    • v.4 no.1
    • /
    • pp.27-33
    • /
    • 2000
  • Purpose: To determine the electronic spin relaxation times, $T_{le}$, of three commercially available Gd-chelated MR contrast agents, Gd-DTPA, Gd-DTPA-BMA and Gd-DOTA, using Electron Paramagnetic Resonance(EPR) technique. Material and Methods: The paramagnetic MR contrast agents, Gd-DTFA(Magnevist) , Gd-DTFA-BMA(OMNISCAN) and Gd-DOTA(Dotarem), were used for this study, The EPR spectra of these contrast agents, which were prepared 2:1 methanol/water solution, were obtained at low temperatures, from $-160^{\circ}C~20^{\circ}C$. The glassy-state EPR spectra for these contrast agents were then fitted by the simulation spectra generated with different zero-field splitting (ZFS) parameters by a computer simulation program 'GEN', which generates the EPR powder spectrum using a given ZFS in $3{\times}3$ tensor. Finally, the spin relaxation times of the contrast agents were then determined from the $T_{2e}$, D, and E values of the best simulation spectra using the McLachlan's theory of average relaxation rate. Results: The electronic transverse spin relaxation times, $T_{2e}'s$, of Gd-DTPA, Gd-DTPA-BMA and Gd-DOTA were 0.113ns, 0.147ns and 1.81ns respectively. The g-values were 1.9737, 1.9735 and 1.9830 and the electronic spin relaxation times, $T_{1e}'s$, were 18.70ns, 33.40ns and $1.66{\mu}s$, respectively. Conclusion: The results of these studies reconfirm that the paramagnetic MR contrast agents with larger ZFS parameters should have shorter $T_{1e}'s$. Among three contrast agents used for this study, Gd-DOTA chelated with cyclic ligand structure shows better electronic property then the others with linear structure. Thus, it is concluded that the exact determination of ZFS parameters is the important factor in evaluating relaxation enhancement effect of the agents and in developing new contrast agents.

  • PDF

Evaluating the Impact of Attenuation Correction Difference According to the Lipiodol in PET/CT after TACE (간동맥 화학 색전술에 사용하는 Lipiodol에 의한 감쇠 오차가 PET/CT검사에서 영상에 미치는 영향 평가)

  • Cha, Eun Sun;Hong, Gun chul;Park, Hoon;Choi, Choon Ki;Seok, Jae Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.67-70
    • /
    • 2013
  • Purpose: Surge in patients with hepatocellular carcinoma, hepatic artery chemical embolization is one of the effective interventional procedures. The PET/CT examination plays an important role in determining the presence of residual cancer cells and metastasis, and prognosis after embolization. The other hand, the hepatic artery chemical embolization of embolic material used lipiodol produced artifacts in the PET/CT examination, and these artifacts results in quantitative evaluation influence. This study, the radioactivity density and the percentage error was evaluated by the extent of the impact of lipiodol in the image of PET/CT. Materials and Methods: 1994 NEMA Phantom was acquired for 2 minutes and 30 seconds per bed after the Teflon, water and lipiodol filled, and these three inserts into the enough to mix the rest behind radioactive injection with $20{\pm}10MBq$. Phantom reconfigure with the iterative reconstruction method the number of iterations for two times by law, a subset of 20 errors. We set up region of interest at each area of the Teflon, water, lipiodol, insert artifact occurs between regions, and background and it was calculated and compared by the radioactivity density(kBq/ml) and the% Difference. Results: Radioactivity density of the each region of interest area with the teflon, water, lipiodol, insert artifact occurs between regions, background activity was $0.09{\pm}0.04$, $0.40{\pm}0.17$, $1.55{\pm}0.75$, $2.5{\pm}1.09$, $2.65{\pm}1.16 kBq/ml$ (P <0.05) and it was statistically significant results. Percentage error of lipiodol in each area was 118%, compared to the water compared with the background activity 52%, compared with a teflon was 180% of the difference. Conclusion: We found that the error due to under the influence of the attenuation correction when PET/CT scans after lipiodol injection performed, and the radioactivity density is higher than compared to other implants, lower than background. Applying the nonattenuation correction images, and after hepatic artery chemical embolization who underwent PET/CT imaging so that the test should be take the consideration to the extent of the impact of lipiodol be.

  • PDF

A study for detection of melt flow zone about polyethylene butt fusion joints (폴리에틸렌 배관 버트융착부 열용융거리 측정에 대한 연구)

  • Kil, Seonghee;Kim, Younggu;Jo, NYoungdo;Lee, Yeonjae
    • Journal of Energy Engineering
    • /
    • v.25 no.4
    • /
    • pp.103-109
    • /
    • 2016
  • Polyethylene pipes has useful benefits which are anti-corrosive and flexible material, so it is used to gas pipes but also class 3 water pipes of nuclear power plant, process pipes of petrochemical plant and chemical plant. So the usage of polyethylene pipes is widely increased. But it has been limited for the usage of polyethylene, because it can not be directly detected to fusion joints by using non destructive evaluation. Polyethylene pipes are connected by two methods, one is butt fusion and the other is electrofusion. Butt fusion is widely used to connecting the pipes. It is proposed to method for determining the reliability of joints in this study that is detection of the melt flow zone at fusion joints. In this study, middle density polyethylene is used, outside diameter of the test specimen is 225mm and thickness is 20.5mm. Speed of ultrasonic of this test specimen is 2,200m/s. Test specimens were fabricated by varying the heating time which means from 0% to 130% applying time through heating plate to polyethylene for detecting melt flow zone. Also 4 additional test specimens were made, one was made that not scrapping attached surface of pipes but applying 100% of the proper heating time and the others were made to include of soil, gravel and vinly tape paper at fusion joints, that were also applied 100% of proper heating time. Ultrasonic testing to measure the melt flow zone of 20 test specimens was conducted by using 3.5MHz and 5.0MHz ultrasonic probes and melt flow zone measuring was conducted to three times at different point to one specimen. To differentiate the melt flow zone signal, post image processing was equally conducted to all test results and image levels, contrast, sharpen, threshold were adopted to all teat results and the test results were displayed gray scale. From the results, for the shorter heating times the reflection area of multiple echo have been increased, so the data was obtained from the position where it can be eliminated as much as possible. At 80% of proper heating time(168 sec.), the signal of melt flow zone was obtained clearly, so measuring could be conducted. From 7% of proper heating time(15 sec.) to shorter heating times. we could not obtain the signal because test specimen was not fused. From the result, we can verify that measuring of melt flow zone by using phased array ultrasonic imaging method is possible. And we can verify to complete and incomplete butt fusion by measuring the melt flow zone.

Position Uncertainty due to Multi-scattering in the Scintillator Array of Dual Collimation Camera (복합 집속 카메라의 섬광체배열에서 다중산란에 의한 위치 불확실성)

  • Lee, Won-Ho
    • Journal of radiological science and technology
    • /
    • v.31 no.3
    • /
    • pp.287-292
    • /
    • 2008
  • Position information of radiation interactions in detection material is essential to reconstruct a radiation source image. With most position sensing techniques, the position information of a single interaction inside the detectors can be precisely obtained. Each interaction position of multi-scattering inside scintillators, however, can not be individually measured and only the average of the scattering positions can be obtained, which causes the uncertainty in the measured interaction position. In this paper, the position uncertainties due to the multi-scattering were calculated by Monte Carlo simulation. The simulation model was a 50 by 50 by 5 mm $LaCl_3$(Ce) scintillator(pixel size is 2 by 2 by 5mm) which was utilized for the dual collimation camera. The dual collimation camera uses the information from both photoelectric effect and Compton scattering, and therefore, position uncertainties for both partial and full energy deposition of radiation interactions are calculated. In the case of partial energy deposition(PED), the standard deviations of positions are less than $1{\sim}2mm$, which means the uncertainty caused by multi-scattering is not significant. Because the effect of the multi-scattering with PED is insignificant, the multi-scattering has little effect on the performance of Compton imaging of dual collimation camera. In the case of full energy deposition(FED), however, the standard deviation of the positions is about twice that of the pixel size of the 1stdetector, except for 122keV incident radiations. Therefore, the standard deviations caused by multi-scatterings should be considered in the design of the coded mask of the dual collimation camera to avoid artifact on the reconstructed image. The position uncertainties of the FEDs are much larger than those of the PEDs for all radiation energies and the ratio of PEDs to FEDs increases when the incident radiation energy increases. The position uncertainties of both PEDs and FEDs are dependent on the incident radiation energy.

  • PDF

Clinical Results Following T3, 4 vs T3 Thoracoscopic Sympathicotomy in 30 Axillary Hyperhidrosis Patients (겨드랑이 다한증 환자에서 흉부교감신경의 차단부위(T3-4와 T4)에 따른 임상결과)

  • Choi, Soon-Ho;Lee, Sam-Youn;Lee, Mi-Kyung;Cha, Byoung-Ki
    • Journal of Chest Surgery
    • /
    • v.41 no.4
    • /
    • pp.469-475
    • /
    • 2008
  • Background: Video-assisted thoracic sympathicotomy is a definitive minimally invasive treatment for axillary hyperhidrosis. Different techniques exist for controlling axillary hyperhidrosis, but they are temporary and expensive. We compared the results after using two different levels of sympathicotomy for treating axillary hyperhidrosis: T3-T4 and T4. Material and Method: Between June 2002 and May 2007, 30 patients with isolated axillary hyperhidrosis underwent either T3-T4 or T4 thoracoscopic sympathicotomy in the Department of Thoracic & Cardiovascular Surgery at Wonkwang University Hospital. The patients were divided into two groups. Group I (n=15) was composed of patients who underwent T3-T4 sympathicotomy (thermal ablation), and Group II (n=15) was composed of patients who underwent T4 sympathicotomy (thermal ablation). The procedures were bilateral and simultaneous, involving the use of two 2-mm trocars and a 0-degree 2-mm thoracoscope under general anesthesia with single endotracheal intubation. Outcome parameters included satisfaction rate of treatment, degree of compensatory sweating, and postoperative complications. Patients were interviewed by telephone regarding satisfaction and compensatory hyperhidrosis. Result: There were no differences in age between group I and group II. The mean follow-up for the T3-T4 group was $38.7{\pm}2.3$ months, and the mean follow-up for the T4 group was $18.7{\pm}3.6$ months. The immediate therapeutic success rate (within 2 weeks postoperative) was 100% in both groups, and there were no recurrences in either group during the long-term follow-up period. The satisfaction rate was higher (93.3%) in the T4 group than in the T3-T4 group (53.3%), and the incidence of compensatory hyperhidrosis was lower in the T4 group (6.7%) than in the T3-T4 group (46.7%). Postoperative complications included one mild pneumothorax and two instances of intercostal neuralgia. Digital infrared thermographic imaging (DITI) correlated well with postoperative satisfaction. Conclusion: Both techniques proved effective for controlling isolated axillary hyperhidrosis. The T4 group had a higher satisfaction rate and lower severity of compensatory hyperhidrosis. Hence, thermal ablation of the lower interganglionic fibers of the third thoracic sympathetic ganglion on the fourth rib is a more practical and minimally invasive treatment than is the T3-T4 surgical method, according to the degree of compensatory sweating in isolated axillary hyperhidrosis.

Magnetic Resonance Voiding Cystography in the Diagnosis of Vesicoureteral Reflux: Comparative Study with Voiding Cystourethrography (방광요관역류의 진단에 있어서 자기공명 배뇨성 방광조영술의 유용성: 태뇨성 요도방광조영술과의 비교연구)

  • Lee, Sang-Kwon;Chang, Yong-Min;Koo, Ja-Hoon;Ko, Cheol-Woo;Chung, Sung-Kwang;Kim, Tae-Hun;Sohn, Kyung-Sik;Lee, Chang-Hyun;Kim, Young-Hwan
    • Investigative Magnetic Resonance Imaging
    • /
    • v.4 no.2
    • /
    • pp.85-93
    • /
    • 2000
  • Purpose: To evaluate the availability of magnetic resonance (MRI voiding cystography for the diagnosis of vesicoureteral reflux (VUR) and to compare the sensitivity of MR voiding cystography (MRVC) with that of radiographic voiding cystourethrography (VCUG) in the detection of VUR. Material and Methods : MRVC was performed upon 20 children referred for investigation of VUR. Either coronal T1-weighted spin-echo or spoiled gradient-echo images were obtained before and after transurethral administration of a mixture of normal saline and gadopentetate dimeglumine, and immediately after voiding. The findings of MRVC were compared with those of VCUG performed within 6 months of MRVC. Results 1 VUR was detected in 23 ureterorenal units f16 VUR's by both methods, five VUR's by VCUG, and two VUR's by MRVC). The sensitivity of VCUG and MRVC in detecting VUR was 91.3% (21/23) and 78.3% (18/23), respectively. MRVC detected renal scarring in 15 out of 17 kidneys with scintigraphically detected renal scarring. Conclusion : Although MRVC is slightly less sensitive than VCUG in the detection of VUR, it can be used for the diagnosis of VUR and renal scarring simultaneouslyl and thus will reduce the radiation hazard.

  • PDF