• Title/Summary/Keyword: imaging material

검색결과 578건 처리시간 0.033초

Angle-Resolved Photoemission Spectroscopy: Momentum-Space Microscope

  • Hwang, Chan-Cuk
    • Applied Microscopy
    • /
    • 제45권3호
    • /
    • pp.115-118
    • /
    • 2015
  • In this review paper, I'd like to introduce the basics of angle-resolved photoemission spectroscopy (ARPES) and some of my results taken at the Pohang Accelerator Laboratory (PAL), the only synchrotron radiation in South Korea. The results show that ARPES is very useful, in particular, for studying two-dimensional materials. It looks like a microscope in momentum space similar to transmission electron microscope imaging atoms in real space.

견관절 삽입술을 시행한 환자의 자기 공명 영상법에 관한 연구 (A Study on MR Imaging Method for The Patient with Inserting Shoulder Joint Suture Anchor)

  • 박의철;배석환;류연철;박영준;김용권
    • 한국산학기술학회논문지
    • /
    • 제22권4호
    • /
    • pp.513-519
    • /
    • 2021
  • 봉합 나사못을 이용한 견관절 수술 환자들의 예후를 확인하기 위하여 MRI(Magnetic Resonance Imaging)를 이용하여 추적검사를 시행한다. 봉합나사못을 삽입한 경우에는 임상적 관찰을 용이하게 하기 위하여 지방소거법을 이용한 영상촬영 기법이 이용되는데, 이때 이용되는 지방 신호 억제 기법으로 CHESS(Chemical Shift Selective), STIR(Short Tau Inversion Recovery), Dixon 기법 등이 주로 이용되고 있다. 봉합나사못은 비자성 재료를 이용해서 제작되지만, 환부에 삽입되는 티타늄 재질의 금속물질은 비자성체임에도 불구하고 국소자장을 왜곡시켜 결과 영상의 기하학적인 왜곡은 물론 심각한 영상신호의 감소 현상을 발생시킨다. 봉합나사못을 삽입하여 환부를 관찰하는 경우에는 뼈 혹은 뼈 인접 부위의 영상을 획득하여야 하는데 뼈와 주변 조직의 임상적 관찰을 위해서는 뼈의 지방 신호를 억제할 필요가 있다. 이때 이용되는 지방 신호 억제 기법은 금속 삽입물로 인한 자기장 불균일의 영향을 받는다. 본 연구에서는 3가지 지방억제 영상기법(CHESS, STIR, Dixon)을 이용하여 금속물질을 삽입한 환자로부터 영상을 획득하여 비교, 분석하였으며, 그 결과로 봉합나사못을 삽입한 환자의 병변 관찰 및 수술 후 예후를 관찰하기 위한 영상기법으로 STIR 영상기법이 가장 적합함을 알 수 있었다. 연구 결과에 따르면 금속 물질을 인체에 삽입한 환자의 경우, 지방 신호 억제가 필요한 MRI 검사에서는 STIR 기법을 이용하는 것이 임상적 가치가 높은 영상을 얻을 수 있을 것이다.

진공증착된 $Cd_{1-x}Zn_{x}Te$ 검출기의 X선 반응 특성 비교 (The Comparison of X-ray Response Characteristics of Vacuum Evaporated $Cd_{1-x}Zn_{x}Te$ Detector)

  • 강상식;최장용;이동길;차병열;김재형;남상희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계학술대회 논문집 센서 박막재료 반도체재료 기술교육
    • /
    • pp.39-42
    • /
    • 2002
  • There is a renewed interest in the application of photoconductors especially Cd(Zn)Te to x-ray imaging. In this paper, We investigate effects on x-ray detection characteristic of Zn dopped CdTe detector. Cd(Zn)Te film was fabricated by vacuum thermal evaporation method and then investigate physical analysis using EPMA and XRD. We investigated the leakage current and X-ray photosensitivity as applied voltage about fabricated Cd(Zn)Te film. Experimental results showed that the increase of Zn dopped concentration in $Cd_{1-x}Zn_{x}Te$ detector reduced a leakage current and improved a signal to noise ratio significantly.

  • PDF

Image Enhancement of Simplified Ultrasonic CT Using Frequency Analysis Method

  • Kim, kyung-Cho;Hiroaki Fukuhara;Hisashi Yamawaki
    • Journal of Mechanical Science and Technology
    • /
    • 제16권12호
    • /
    • pp.1627-1632
    • /
    • 2002
  • In this paper, a simplified ultrasonic CT system, which uses the information in three directions, that is, 90°, +45° and -45°about the inspection plane, is applied to the high strength steel, and the frequency analysis method for enhancing the C scan or CT image is developed. This frequency analysis method is based on the frequency response property of the material. By comparing the magnitudes in the frequency domain, the special frequency which shows a significant difference between the welded joint and base material was found and used to obtain a C scan or CT image. Experimental results for several kinds of specimens, having a welded joint by electron beam welding, a weld joint by arc welding, on a fatigue crack, showed that the obtained C scan or CT image has better resolution than the results of previous experiments using the maximum value of the received waveform.

Detection of Second-Layer Corrosion in Aging Aircraft Fuselage

  • Kim, Noh-Yu;Achenbach, J.D.
    • 비파괴검사학회지
    • /
    • 제26권6호
    • /
    • pp.417-426
    • /
    • 2006
  • A Digital X-ray imaging system using Compton backscattering has been developed to obtain a cross-sectional profile and mass loss of corroded lap-splices of aging aircraft from density variation. A slit-type camera was designed to focus on a small scattering volume inside the material, from which the backscattered photons are collected by a collimated scintillator detector for interpretation of material characteristics. The cross section of the lap-joint is scanned by moving the scattering volume through the thickness direction of the specimen. The mass loss of each layer has been estimated from a Compton backscatter A-scan to obtain the thickness of each layer including the aluminum sheet, the corrosion layer and the sealant. Quantitative information such as location and width of planar corrosion in the lap splices of fuselages is obtained by deconvolution using a nonlinear least-square error minimization method(BFGS method): A simple reconstruction model is also introduced to overcome distortion of the Compton backscatter data due to attenuation effects attributed to beam hardening and quantum noise.

Focused Electron Beam-Controlled Graphene Field-Effect Transistor

  • Kim, Songkil
    • 한국전기전자재료학회논문지
    • /
    • 제33권5호
    • /
    • pp.360-366
    • /
    • 2020
  • Focused electron beams with high energy acceleration are versatile probes. Focused electron beams can be used for high-resolution imaging and multi-mode nanofabrication, in combination with, molecular precursor delivery, in an electron microscopy environment. A high degree of control with atomic-to-microscale resolution, a focused electron beam allows for precise engineering of a graphene-based field-effect transistor (FET). In this study, the effect of electron irradiation on a graphene FET was systematically investigated. A separate evaluation of the electron beam induced transport properties at the graphene channel and the graphene-metal contacts was conducted. This provided on-demand strategies for tuning transfer characteristics of graphene FETs by focused electron beam irradiation.

적색 발광하는 금 나노클러스터 합성 (Synthesis of Red Light Emitting Au Nanocluster)

  • 차대경;윤상민;김미성;방지원
    • 한국전기전자재료학회논문지
    • /
    • 제29권11호
    • /
    • pp.685-689
    • /
    • 2016
  • Synthesis of the fluorescent Au nanoclusters is reported. The Au nanoclusters were synthesized via reduction of gold ions in reverse micelles with mild reducing agents. The Au nanoclusters show a bright red emission at 640 nm. The fluorescent Au nanoclusters attract great interest for sensor, electronic device and bio-imaging applications because of ultra-small size, high chemical stablity and bright emission. We believe that the fluorescent Au nanoclusters can have optoelectronic applications such as optical down conversion phosphors.

Long-term Testing and Analysis of a ScSZ/LaSrCuFe Cell

  • Wackerl, Jurgen;Peck, Dong-Hyun;Markus, Torsten
    • 한국세라믹학회지
    • /
    • 제45권12호
    • /
    • pp.788-795
    • /
    • 2008
  • An electrolyte supported SOFC cell was tested at $800^{\circ}C$ in air for 3600 h with an applied current density of $200\;mA/cm^2$ to examine possible cathode degradation issues. A scandium- stabilized zirconia (ScSZ) with additional manganese doping (ScSZ: Mn) was used as electrolyte. A strontium and copper-doped lanthanum ferrite (LaSrCuFe) and platinum were used as cathode and quasi-anode material, respectively. The DC resistance was logged over the complete testing period. Additionally, impedance spectroscopy was used from time to time to track changes of the cell in-situ. Post-test analysis of the cell using methods like scanning electron microscopy imaging and other electrochemical testing methods allow the identification of different degradation sources. The results indicate a promising combination of electrolyte and cathode material in terms of chemical compatibility and electrical performance.

LED 조명기구의 EMI 디버깅 기술 (EMI Debugging Technique of LED Lighting Module)

  • 김진사
    • 한국전기전자재료학회논문지
    • /
    • 제33권2호
    • /
    • pp.151-154
    • /
    • 2020
  • Radiation noise due to EMI noise generated by the driving circuits of LED lighting devices in a medical imaging room was reduced by decreasing the noise source in the driving circuits and changing the number of corrections in EMI filters. Noise attenuation and filter changes enabled driving circuits that reduced the electromagnetic waves. Such circuits were efficiently designed by using capacitors and inverters in a given space. Therefore, the malfunction of radiation devices can be minimized by using EMI-reduction filter circuits, and reliable operation of medical devices can be expected by blocking electromagnetic waves.

우주관측용 광학계의 적외선 초자 초정밀 가공 기술개발 (Development of the Ultra Precision Machining of IR Material for Space Observation Optical System)

  • 양순철;원종호
    • 한국정밀공학회지
    • /
    • 제27권12호
    • /
    • pp.9-14
    • /
    • 2010
  • Using an IR (infrared) optical system of observation and research were performed long before. Nowadays satellites equipped with IR optical system observe the earth and universe. In this paper, we developed the IR optical system for main payload of the STSAT-3 (Science and Technology Satellite -3). We studied the ultra precision machining technique to fabricate FPL-53 lenses which is the IR optical material for space observation camera of the STSAT-3. DOE (Design of Experiment) was used to find best machining characteristic for FPL-53. Finally we fabricated FPL-53 aspheric lens with the form accuracy of P-V $0.36\;{\mu}m$.