• Title/Summary/Keyword: image technology

Search Result 9,453, Processing Time 0.044 seconds

2D-to-3D Stereoscopic conversion: Depth estimation in monoscopic soccer videos (단일 시점 축구 비디오의 3차원 영상 변환을 위한 깊이지도 생성 방법)

  • Ko, Jae-Seung;Kim, Young-Woo;Jung, Young-Ju;Kim, Chang-Ick
    • Journal of Broadcast Engineering
    • /
    • v.13 no.4
    • /
    • pp.427-439
    • /
    • 2008
  • This paper proposes a novel method to convert monoscopic soccer videos to stereoscopic videos. Through the soccer video analysis process, we detect shot boundaries and classify soccer frames into long shot or non-long shot. In the long shot case, the depth mapis generated relying on the size of the extracted ground region. For the non-long shot case, the shot is further partitioned into three types by considering the number of ground blocks and skin blocks which is obtained by a simple skin-color detection method. Then three different depth assignment methods are applied to each non-long shot types: 1) Depth estimation by object region extraction, 2) Foreground estimation by using the skin block and depth value computation by Gaussian function, and 3)the depth map generation for shots not containing the skin blocks. This depth assignment is followed by stereoscopic image generation. Subjective evaluation comparing generated depth maps and corresponding stereoscopic images indicate that the proposed algorithm can yield the sense of depth from a single view images.

Three-Dimensional Kinematic Model of the Human Knee Joint during Gait

  • Mun, Joung-Hwan;Seichi Takeuchi
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.3
    • /
    • pp.171-179
    • /
    • 2002
  • It is well known that the geometry of the articular surface plays a major role in the kinematic and kinetic analysis to understand human knee joint function during motion. The functionality of the knee joint cannot be accurately modeled without considering the effects of sliding and lolling motions. We Present a 3-D human knee joint model considering sliding and rotting motion and major ligaments. We employ more realistic articular geometry using two cam profiles obtained from the extrusion of the sagittal Plain view of the representative Computerized Tomography image of the knee joint compared to the previously reported model. Our model shows good agreement with the already reported experimental results on Prediction of the lines of force through the human joint during gait. The contact point between femur and tibia moves toward the Posterior direction as the knee undergoes flexion, reflecting the coupling of anterior and Posterior motion with flexion/extension. The anterior/posterior displacement of the contact Point on the tibia plateau during one gait cycle is about 16 mm. for the lateral condyle and 25 mm. for the medial condyle using the employed model Also. the femur motion on the tibia undergoes lateral/medial movement about 7 mm. and 10 mm. during one gait cycle for the lateral condyle and medial condyle. respectively. The developed computational model maybe Potentially employed to identify the joint degeneration.

From Broken Visions to Expanded Abstractions (망가진 시선으로부터 확장된 추상까지)

  • Hattler, Max
    • Cartoon and Animation Studies
    • /
    • s.49
    • /
    • pp.697-712
    • /
    • 2017
  • In recent years, film and animation for cinematic release have embraced stereoscopic vision and the three-dimensional depth it creates for the viewer. The maturation of consumer-level virtual reality (VR) technology simultaneously spurred a wave of media productions set within 3D space, ranging from computer games to pornographic videos, to Academy Award-nominated animated VR short film Pearl. All of these works rely on stereoscopic fusion through stereopsis, that is, the perception of depth produced by the brain from left and right images with the amount of binocular parallax that corresponds to our eyes. They aim to emulate normal human vision. Within more experimental practices however, a fully rendered 3D space might not always be desirable. In my own abstract animation work, I tend to favour 2D flatness and the relative obfuscation of spatial relations it affords, as this underlines the visual abstraction I am pursuing. Not being able to immediately understand what is in front and what is behind can strengthen the desired effects. In 2015, Jeffrey Shaw challenged me to create a stereoscopic work for Animamix Biennale 2015-16, which he co-curated. This prompted me to question how stereoscopy, rather than hyper-defining space within three dimensions, might itself be used to achieve a confusion of spatial perception. And in turn, how abstract and experimental moving image practices can benefit from stereoscopy to open up new visual and narrative opportunities, if used in ways that break with, or go beyond stereoscopic fusion. Noteworthy works which exemplify a range of non-traditional, expanded approaches to binocular vision will be discussed below, followed by a brief introduction of the stereoscopic animation loop III=III which I created for Animamix Biennale. The techniques employed in these works might serve as a toolkit for artists interested in exploring a more experimental, expanded engagement with stereoscopy.

Introduction of Hindfoot Coronal Alignment View (후족부 관상면 배열 영상에 대한 고안)

  • Moon, Il-Bong;Jeon, Ju-Seob;Yoon, Kang-Cheol;Choi, Nam-Kil;Kim, Seung-Kook
    • Journal of radiological science and technology
    • /
    • v.29 no.4
    • /
    • pp.225-228
    • /
    • 2006
  • Purpose: Accurate clinical evaluation of the alignment of the calcaneus relative to the tibia in the coronal plane is essential in the evaluation and treatment of hindfoot pathologic condition. Previously described standard anteroposterior, lateral, and oblique radiographic methods of the foot or ankle do not demonstrate alignment of the tibia relation to the calcaneus in the coronal plane. The purpose of this study was to introduce hindfoot coronal alignment view. Material : 1) Both feet were imaged simultaneously on an elevated, radiolucent foot stand equipment. 2) Both feet stood on a radiolucent platform with equal weight on both feet. 3) Both feet are located foot axis longitudinal perpendicular to the platform. 4) Silhouette tracing around both feet are made, and line is then drawn to bisect the silhouette of the second toe and the outline of the heel. 5) The x-ray beam is angled down approximately $15^{\circ} to $20^{\circ} Result : 1) This image described tibial axis and medial, lateral tuberosity of calcaneus. 2) Calcaneus do not rotated. 3) The view is showed by talotibial joint space. Conclusion: Although computed tomographic and magnetic resonance imaging techniques are capable of demonstrating coronal hindfoot alignment, they lack usefulness in most clinical situations because the foot is imaged in a non-weight bearing position. But hindfoot coronal alignment view is obtained for evaluating position changing of inversion, eversion of the hindfoot and varus, valgus deformity of calcaneus.

  • PDF

A Study on the Distribution of Scatter Ray in Chest Radiography of a Health Examination Bus (건강검진 차량 내 흉부 방사선검사 시 공간산란선 분포 연구)

  • Cho, Ji-Hwan;Jin, Seong-jin;Min, Byeong-In
    • Journal of radiological science and technology
    • /
    • v.40 no.3
    • /
    • pp.377-383
    • /
    • 2017
  • The purpose of this study was to evaluate the distribution of spatial scatter ray on the chest radiographs of patients on health examination bus. In this paper, we propose a method for minimize unnecessary exposure by measuring the scattered dose after exposure the actual subject and comparing the body mass index (BMI) with the tube current amount mAs. The results of this study showed that the mean BMI of the subjects was $23.31{\pm}3.12$. The mean mAs value was $2.92{\pm}1.19$, which males was higher than females. The mean value of the scatter ray at position 1 in the radiography room was $771.81{\pm}151.15{\mu}Sv/hr$. The mean value of the scatter rays at the position 2 outside the entrance of the radiography room was measured as $53.86{\pm}25.66{\mu}Sv/hr$. As the BMI and mAs was increase the spatial scatter dose was increased at position 1 and position 2 in the photographing room. In order to minimize the exposure dose of scatter ray, radiation workers should shoot the radiation as low as possible within the range that does not impair the quality of the image. It will be necessary to make efforts to not wait for a waiting person near the entrance door of the photographing room.

The Study on Threats of Information Security and Their Solutions in the Fourth Industrial Revolution (4차 산업혁명 시대에 정보보안의 위협요인과 대응방안에 대한 연구)

  • Cho, Sung-Phil
    • Korean Security Journal
    • /
    • no.51
    • /
    • pp.11-35
    • /
    • 2017
  • The third industrial revolution, characterized by factory automation and informatization, are moving toward the fourth industrial revolution which is the era of superintelligence and supernetworking through rapid technology innovation. The most important resources in the fourth industrial revolution are information or data since the most of industrial and economic activities will be affected by information in the fourth industrial revolution. Therefore we can expect that more information will be utilized, shared and transfered through the networks or systems in real time than before so the significance of information management and security will also increase. As the importance of information resource management and security which is the core of the fourth industrial revolution increases, the threats on information security are also growing so security incidents such as data breeches and accidents take place more often. Various and thorough solutions are highly needed to protect information resources from security risks because information accidents or breaches seriously damage brand image and cause huge financial damage to organization. The purpose of this study is to research general trends on data breaches and accident that can be serious threat of information security. Also, we will provide resonable solutions to protect data from nine attack patterns or other risk factors after figuring out each characteristic of nin attack patterns in data breaches and accidents.

  • PDF

Effect of the STereoLithography File Structure on the Ear Shell Production for Hearing Aids According to DICOM Images (DICOM 영상에 의한 STL 파일 구조가 보청기 이어 쉘 제작에 미치는 영향)

  • Kim, Hyeong-Gyun
    • Journal of radiological science and technology
    • /
    • v.40 no.1
    • /
    • pp.121-126
    • /
    • 2017
  • A technique for producing the ear shell for a hearing aid using DICOM (Digital Imaging and Communication in Medicine) image and a 3D printing was studied. It is a new application method, and is an application technique that can improve the safety and infection of hearing aid users and can reduce the production time and process stages. In this study, the effects on the shape surface were examined before and after the printing of the ear shell using a 3D printer based on the values obtained from the raw data of the DICOM images at the volumes of 0.5 mm, 1.0 mm, and 2.0 mm, respectively. Before the printing, relative relationship was compared with respect to the STL (STereoLithography) file structure; and after the printing, the intervals of the layered structure of the ear shell shape surface were compared by magnifying them using a microscope. For the STL file structure, the numbers of triangular vertices, more than five intersecting points, and maximum intersecting points were large in the order of 0.5 mm, 1.0 mm, and 2.0 mm, respectively; and the triangular structure was densely distributed in the order of the bending, angle, and crest regions depending on the sinuosity of the external auditory meatus shape. As for the ear shell shape surface examined by the digital microscope, the interval of the layered structure was thick in the order of 2.0 mm, 1.0 mm, and 0.5 mm. For the STL surface structure mentioned above, the intersecting STL triangular structure was denser as the sinuosity of the 3D ear shell shape became more irregular and the volume of the raw data decreased.

Bacteriological Research for the Contamination of Digital Portable Radiography (디지털 이동방사선검사에서의 세균 오염도)

  • Shin, Seong-gyu;Lee, Hyo-Yeong
    • Journal of radiological science and technology
    • /
    • v.40 no.1
    • /
    • pp.7-12
    • /
    • 2017
  • The study was performed to investigate the bacteriological contamination of portable digital radiography system and their detectors in a university hospital. CNS and VRE were detected in the samples collected from vinyl cover on detectors used for the infection control patients. On the other hand, no bacteria was detected in the samples collected from detectors with vinyl cover removed. In the series of imaging of patients from general wards, no bacteria was detected from the patient 1. However, CNS was detected from the patients 2 and 3, CNS and Enterococcus faecalis detected from the patient 4, CNS and Enterococcus casseliflavus detected from the patient 5, and CNS, Enterococcus casseliflavus, and Klebsiella pneumoniae all detected from the patient 6. CNS and Enterococcus faecium were detected in the controller handle of collimator. Also, CNS was detected from the handle of detector and exposure switch. In the treatment gloves of the radiological technologist after the imaging, CNS, Enterococcus gallinarum, and Klebsiella pneumoniae were detected. Therefore, it is recommended for DR portable to take images after sterilizing the detector after taking each image and to use disposable vinyl covers on detectors to remove after imaging. And treatment gloves must be changed after each imaging. Also, hospital infection via portables must be prevented by complete sterilization of the controller handles of collimator which are in frequent contact during imaging and infection education of employees.

Spatial Relationship of the Left Ventricle in the Supine Position and the Left Lateral Tilt Position (Implication for Cardiopulmonary Resuscitation in Pregnant Patients) (앙와위와 좌측 기울린위치에서의 좌심실의 공간적 관계 변화. 임신부 심폐소생술 측면에서)

  • Yun, Jong Geun;Lee, Byung Kook
    • Fire Science and Engineering
    • /
    • v.27 no.5
    • /
    • pp.75-79
    • /
    • 2013
  • Application of the left lateral tilt position has been recommended during cardiopulmonary resuscitation (CPR) of pregnant patients. However, the left lateral tilt could displace the left ventricle (LV) besides the gravid uterus and may compromise the cardiac pump mechanism of CPR. Thus, we investigated the effect of left lateral tilt on the spatial relationship between the anterior-posterior axis (AP axis), which represents the direction of sternal displacement during CPR, and the LV. We retrospectively reviewed the medical records and multidetector computed tomography (MDCT) scans of 90 patients who underwent virtual gastroscopy using MDCT. Virtual gastroscopy was performed with the patient both in the left lateral tilt position and in the supine position. On an axial image showing the maximal area of the LV, the angle between the AP axis and the LV axis ($Angle_{AP-LV}$), the shortest distance between the AP axis and the mid-point of LV cavity ($D_{AP-MidLV}$) and the shortest distance between the AP axis and the LV apex ($D_{AP-Apex}$) were measured. In the supine scans, the LV was situated on the left side of the AP axis in 87 patients (96.7%). On the left lateral tilt scans, the mean tilt angle was $43.4{\pm}11.0^{\circ}$. $D_{AP-MidLV}$ and $D_{AP-Apex}$ were significantly longer in the left lateral tilt position (p<0.001), but $Angle_{AP-LV}$ was comparable between the positions. This study indicates that the left lateral tilt position may compromise the cardiac pump mechanism of chest compression in pregnant cardiac arrest patients.

Analysis of Risk factors & Morphological Ultrasound Image for Gallbladder Polyp in Adults Living in Busan and Gyeongnam Provinces (부산·경남 지역 성인의 담낭용종 위험인자 및 초음파 영상의 형태학적 분석)

  • An, Hyeon;Hwang, Chul-Hwan;Ko, Sung-Jin;Kim, Chang-Soo
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.353-359
    • /
    • 2016
  • This study were to evaluate risk factors of GB polpy in Busan and Gyeongnam area. This study was performed with patients by abdominal ultrasonography among the patients who came to the P hospital from January to May 2016. Among them, risk factors were analyzed on 399 people at the same time when abdominal ultrasonography and hematological test. The statistical analysis of risk factors related to the GB ployp was performed by independent t-test and chi-square test. In consider of difference verification result for calculations odds ratio about independent variables, multiple logistic regression analysis to conduct verify adequacy by calculating forecasting model from variable. As a result, GB polyp risk factors have relevance to male, HBsAg positive, triglyceride. GB polyp risk factors confirmed to male, HBsAg positive, triglyceride were calculated forecasting model and forecasting probability value. Forecasting probability sensitivity 61.0%, specificity 76.8%, ROC area under curve 0.735 showed, it confirmed validity of forecasting model. When analyzing the GB polyps morphologically, among the GB polyp types observed from abdominal ultrasonography, the hyperechoic and homogeneous pattern with neck was the largest as shown from 27.5% and two GB polyps were shown most from 38%, sizes were shown most by maximum diameter, 5 to 10mm from 53%. As a disease accompany with GB polyp showed mild fatty liver(23%), diffuse hepatopathy(21%).