• Title/Summary/Keyword: illuminance/Luminance Measurement

Search Result 11, Processing Time 0.016 seconds

Investigation of Roadway Lighting by Measurement of Illuminance and Luminance Distribution (조도/휘도 분포측정을 통한 도로조명 실태조사)

  • Kim, Hyeong-Kwon;Han, Jong-Sung;Hwang, In-Tae;Lee, Mi-Ae;Kim, Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.1
    • /
    • pp.17-23
    • /
    • 2008
  • In this paper, we used "Double Photometric System for Road Lighting" and measured roadway lighting of the metropolitan area by a measurement of illuminance and luminance. As a result, so many roads were dissatisfied with the permitted range of roadway lighting because of the road shape, lighting method, trees lining a street and obstacles.

Development of the Mobile Measuring System for Tunnel Lighting Luminance and Illuminance (차량을 이용한 터널조도 및 휘도 측정시스템 개발)

  • Kim, Dong-Jo;Jo, Duk-Soo;Suk, Dae-Il;Jung, Sueng-Kyun;Lee, Chang-Mo;Nam, Dong-Hoon;Kim, Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.4
    • /
    • pp.1-6
    • /
    • 2006
  • The tunnel is the place where brightness changes abruptly. It is important to grasp the road situation and the traffic situation of the tunnel accurately for safe and secure driving, and tunnel lighting installation should be well maintained. Luminance and illuminance of the tunnel inside should be measured periodically to maintain enough brightness. But traditional manual measurement could not guarantee the fastness and trustworthy of the measured values. In this paper, a mobile measuring system for tunnel lighting luminance and illuminance was developed and a result regarding the propriety of the system was derived.

Measurement of MRI Monitor Luminance and MRI Room Illuminance with a Light Probe (Light Probe를 이용한 MRI 검사실 및 모니터의 조도와 휘도 측정)

  • Kim, Ji Min;Han, Ah Yung;Lee, Ha Young;Lee, So Ra;Kweon, Dae Cheol
    • Journal of the Korean Magnetics Society
    • /
    • v.26 no.5
    • /
    • pp.168-172
    • /
    • 2016
  • The purpose of the optimal environment of the MRI room to measured luminance and illuminance of the MRI room and the monitor. University Hospital (n = 6) of the MRI (n = 10) in the luminance and illuminance Light Probe Xi Unfors (Unfors Instruments AB, Billdal, Sweden) was measured by using the. Black luminance level and white level of illuminance is repeated three times in the middle of the side of the monitor to obtain the mean and standard deviation using a t-test statistical processing was of significance test. Monitor luminance and black level in the average $1.78cd/m^2$, the standard deviation was $0.85cd/m^2$, white level average of $43.58cd/m^2$, the standard deviation of $13.19cd/m^2$. Illuminance of MRI room was the lowest value measured in accordance with the 30.5 lux, the maximum value is 601.3 lux, mean was measured by a variety of 177.86 lux. Luminance and illuminance of the MRI room and monitor is found to have statistically significant difference (p < .05). In conclusion, refer to the recommended standard of MRI and room monitor luminance and illuminance and to create an optimal environment.

A Study of HDR Software Reliability for the Luminance Map Creation (휘도맵의 작성을 위한 HDRI 생성 도구의 신뢰도에 관한 연구)

  • Hong, Sung-De
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.12 no.3
    • /
    • pp.81-89
    • /
    • 2012
  • Luminance is the most important quantity in lighting design and illuminating engineering. There are three methods for measuring luminance; using a conventional luminance meter, through the illuminance measurement and subsequent calculations and using digital imaging photometer. Recently, HDRI(High Dynamic Range Imaging) technique introduces a new method of capturing luminance values in a lighting environment. The radiance maps from HDRI are commonly used as visual environment maps for lighting analysis applications. For the HDRI, HDR software is needed to create HDR image. Currently, there is number of HDR software available. The purpose of this paper is to investigate whether a luminance map can be accurately captured by the various types of HDR software which include HDR Shop and Photoshop. To accomplish this goal a set of experiments was conducted. In order to assess the luminance values of the HDR image from HDR software, the values had to be compared to the ones obtained with conventional methods of luminance measurement.

Luminance Analysis of the Apartment Exterior Lighting using HDR Images (HDR이미지를 이용한 공동주택 외부조명의 휘도 분석)

  • Hong, Sung-De;Shin, Eun-Ju
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.12 no.2
    • /
    • pp.33-38
    • /
    • 2012
  • The purpose of luminance measurement in lighting design of urban scale is to prevent light trespass and light pollution, caused by over-bright. Specially, the illumination of road, tunnel and sports complex as urban infrastructure is measured by international standard for illuminance and luminance. It has been used the spot luminance meter and the image photometer to define the characteristics of qualitative and quantitative in exterior lighting. This study introduced the concept of HDR Image, procedure of HDR Image creation and analysis. Applications of HDR Image, particularly within the apartment building exterior lighting design analysis, have been demonstrated. The procedure proposed in this study is a affordable method that is useful for the assessment of luminance distribution in the scene with electric light. It also provides a measurement capability with the high resolution luminance data within a large field of view efficiently and quickly, which is not possible to achieve with a luminance meter.

A Study on Maintenance Planning for Efficient Urban Lighting in Wonju-si (원주시의 효율적인 도시조명을 위한 관리 계획에 관한 연구)

  • Lee, Yeon-So;Woo, Soo-Jin;Choi, Key-Soo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.4
    • /
    • pp.7-15
    • /
    • 2011
  • Based on the master plan, this study classified Wonju-si into five major regions and 19 areas by analyzing its night characteristics and deduced problems by analyzing quantitative light distribution of major points at the regions and areas through the measurement of illuminance and luminance and by surveying people's awareness. To develop eco-friendly night environment image of Wonju, Woju's identify was to be created by the planning for the 19 area and improvements for each type. Additionally, detailed items for maintenance were suggested by classifying them into illuminance, color temperature, luminance, lighting display, lighting time, light distribution type, and so forth.

Study of Lighting for Museum Exhibitions (박물관 전시 조명 조사 연구)

  • Lee, Sungeun;Jason, Jae Gill
    • Conservation Science in Museum
    • /
    • v.19
    • /
    • pp.83-98
    • /
    • 2018
  • Most preceding studies on museum lighting have focused mainly on illuminance, however this study examines diverse lighting characteristics, including illuminance, luminance, color temperature, and color rendering to allow a more objective evaluation of museum lighting. In particular, issues with existing museum lighting were examined through visual measurement to find an appropriate condition complying with museum lighting standards while providing a pleasant lighting experience for visitors. Although the top priority of museum lighting is to safely protect collections on display, lighting that takes into consideration luminance, color temperature and color randition will allow more effective appreciation as well as safe conservation of the exhibits.

Comparison Research between Lighting Based on luminance and Illuminance through Measuring Tunnel Lighting (터널조명 측정을 통한 조도와 휘도기반의 조명 비교 연구)

  • Lee, Mi-Ae;Han, Seung-Hun;Kim, Yeon-Hwa
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.11
    • /
    • pp.14-19
    • /
    • 2013
  • Tunnel lighting design and operation are both regulated based on luminance in and out of Korea these days. However, domestic tunnel lighting is operated by internal lighting depending on external brightness by using an illuminometer applying the conversion factor on luminance. The purpose of tunnel lighting is to alleviate the visual shock occurring from the rapid change from external brightness to internal brightness when entering a tunnel. However, when looking at the tunnels operated based on an illuminometer, it is not a system where the driver can measure the brightness within his or her viewing angle when entering the tunnel. It is general to install and operate the illuminometer on the roof of an administrative office near the tunnel; however, this method is not structured to connect with the internal lighting by checking the brightness of the viewing scope of the driver, thus is not structured to properly apply the viewing conditions of the driver. Rather, it should be in a method for extracting the luminance value within the viewing scope of the driver pursuant to tunnel lighting standards and in connection with internal lighting. This research seeks to find the difference between operations based on luminance and operations based on intensity of Illuminance in road tunnels through field measuring, and to suggest the necessity of operating based on luminance with the resulting value.

Light Pollution Survey of Outdoor Lighting in Shopping Complex (쇼핑용 복합빌딩의 옥외조명으로 인한 광공해발생 실태조사)

  • Ahn, Hyun-Tae;Kim, Jeong-Tai
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.5
    • /
    • pp.16-26
    • /
    • 2004
  • As the importance of outdoor lighting become more widely recognized, outdoor lighting has been installed in many buildings, plazas, landscape, and historical monuments in Korea, Outdoor lighting on showing complex, in particular, express its values as local landmarks. However, the excessive outdoor lighting in the large-scale shopping complex tends to cause light pollution. Many advanced countries are trying to create a comfortable lighting environment by the guidlines and regulations on outdoor lighting to prevent light pollution. For this research backgrounds, the light pollution of three showing complexes in Seoul have been investigated. For the purpose, luminance of building facade, horizontal illuminance, and vertical illuminance were measured with proper measurement instruments and compared the results with the CIE recommendations. The results of the study are as follows. As no cut-off luminaries are currently installed on pedestrian walks, some glare were occured partially. It also shows that the luminance of building facades are high to improve the degree of public awareness of buildings and advertisements. In other words, the luminance of the building facade, when compared with that of the CIE recommendations, is twice as high and the vatical illuminance of pedestrian walks is far higher than that of the CIE recommendations, which proves the existence of light pollution. As Korea has not yet provided proper regulations or guidelines for the control of light pollution, it is necessary to make appropriate codes for it.

A Study about the Measurement and Analysis of Daylight Performance of the Changdeokgung Nakseonjae (창덕궁 낙선재의 빛환경 성능측정 및 분석에 관한 연구)

  • Kim, Yu-Sin;Lim, Ji-Sun;Jung, Yeon-Hong;Han, Wook;Choi, An-Seop
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.2
    • /
    • pp.36-44
    • /
    • 2009
  • The aim of this study is to analyze the daylight performance at Changdeokgung Nakseonjae that is the representative and most well preserved Korean royal palace. As a result of measuring illuminance and luminance, direct sunlight is cut off by the eaves and reflective light from the court yard comes in the inside of the floor. As the layer of window is increased, daylight is decreased and the illuminance distribution is more stable because of decreasing of illuminance changes. Also, the lower part luminance is higher than upper part of window surface because direct sunlight is cut off by the eaves. This study would be used as preliminary data for applying characteristics of lighting environment of Korean royal palace to modem architecture.