• Title/Summary/Keyword: idea measurement

Search Result 181, Processing Time 0.026 seconds

Performance Evaluations of the Lightning Impulse Voltage Measuring System by Intercomparative Test - in case of full lightning impulse voltage - (뇌충격 측정시스템의 비교시험에 의한 성능평가 - 전파 뇌충격전압 인가시 -)

  • Kim, Ik-Soo;Kim, Young-Bae;Lee, Hyeong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1368-1370
    • /
    • 1995
  • Lightning impulse voltage is essential to evaluate the insulation performance of electric power apparatus. Recently international standard(IEC-60) on high voltage measurement techniques are being revised. In the draft of this standard, a new calibration method is introduced and the accuracy of most industrial measuring systems is maintained by means of comparison test against the reference measuring systems. Intercomparison tests of dividers for lightning impulse measurement were carried out by KERI. The shielded resisitive divider with 700kV rating developed by KERI were done comparison test with PTB divider with 300kV rating which have the similar charateristics as that were circulated among the laboratories. This paper reports on the comparison test results with full lightning impulse voltages from 126kV to 240kV. It is demonstrated that KERI are capable of realizing the idea in the revision of the IEC standand, that is, to establish traceability.

  • PDF

A Study on the Compensation Method in the Measuring System for Chopped Lightning Impulse (충격전압 재단과 측정을 위한 보상회로에 관한 연구)

  • Kim, Ik-Soo;Kim, Young-Bae;Kim, Jin-Gi;Kim, Min-Kyu
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1895-1897
    • /
    • 1996
  • Lightning impulse voltage is essential to evaluate the insulation performance of electric power apparatus. Recently international standard (IEC-60) on high voltage measurement techniques are being revised. In the draft of this standard, a new calibration method is introduced and the accuracy of most industrial measuring systems is maintained by means of comparison test against the reference measuring systems. Comparison tests of dividers for chopped lightning impulse measurement were rallied out by KERI. The 700kV shielded resisitive divider with and without compensation element were done comparison test with 300kV PTB divider which have the similar charateristics as that were circulated among the laboratories. This paper reports on the calculation results of response charateristics obtained by EMTP and the comparison test results with chopped lightning impulse voltages from 150kV to 250kV. It is demonstrated that KERI are capable of realizing the idea in the revision of the IEC standand, that is, to establish traceability.

  • PDF

Exposure to Fine Particle along Different Commuting Routes in Urban Area of Fukuoka, Japan

  • Ma, Chang-Jin
    • Asian Journal of Atmospheric Environment
    • /
    • v.9 no.3
    • /
    • pp.205-213
    • /
    • 2015
  • The objective of the current study was to assess the comparative risk associated with exposure to particulate matter (PM) while commuting via different public transport modes in Fukuoka, Japan. For the given routes and measuring days, a trip-maker carried a lightweight portable bag loaded the real-time measurement devices which take simultaneous measurement for size-fractioned particle number concentration, $PM_{2.5}$ mass concentration, and total suspended particle (TSP) collection. The results of the present study have shown significant differences between public transports as commuting modes in Fukuoka. The PM exposure levels on subway platform and inside subway train were overwhelmingly higher than those of other points on commuting route. The relative ratio between modes (i.e., the ratio of $PM_{2.5}$ inside subway to that inside bus) provides an idea for choosing a right commuting mode for our health. This study clearly provided evidence of the extremely high levels of iron exposure by subway uses compared to bus uses. The result of theoretically reconstructed mass concentration of $PM_{2.0-0.3}$ collected on subway platform suggests that the PM of underground subway will be associated with PM both generated in subway system and inleakaged from outdoor environment.

Automatic Quality Measurement of Gray-scale Handwriting Based on Extended Average Entropy (확장된 평균 엔트로피에 기반한 명도 영상 필기 데이터의 품질 자동 평가)

  • 박정선
    • Korean Journal of Cognitive Science
    • /
    • v.10 no.3
    • /
    • pp.77-83
    • /
    • 1999
  • With a surge of interest in OCR in 1990s a large number of handwriting or h handprinting databases have been built one after another around the world. One problem that researches encounter today is that all the databases differ in various ways including the script qualities. This paper proposes a method for measuring handwriting qualities that can be used for comparison of databases and objective test for character recognizers. The key idea i involved is classifying character samples into a number of groups each characterizing a set of qualities. In order to evaluate the proposed method we carried out experiments on KU-1 database. The result we achieve is meaningful and the method is helpful for the target tasks.

  • PDF

An Efficient Attitude Reference System Design Using Velocity Differential Vectors under Weak Acceleration Dynamics

  • Lee, Byungjin;Yun, Sukchang;Lee, Hyung-Keun;Lee, Young Jae;Sung, Sangkyung
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.17 no.2
    • /
    • pp.222-231
    • /
    • 2016
  • This paper proposes a new method achieving computationally efficient attitude reference system for low cost strapdown sensors and microprocessor platform. The main idea in this method is to define and compare velocity differential vectors, geometrically computed from INS and GPS data with different update rate, for generating attitude error measurements which is further used for filter construction. A quaternion based Kalman filter configuration is applied for the attitude estimation with the adapted measurement model of differential vector comparison. Linearized model for Extended Kalman Filter and low pass filtered characteristics of measurement greatly extend the affordability of the proposed algorithm to the field of simple low cost embedded systems. For performance verification, experiment are done employing a practical low cost MEMS IMU and GPS receiver specification. Performance comparison with a high grade navigation system demonstrated good estimation result.

Characterization and Standardization of Piezoelectric Thin Films (압전박막의 특성평가 및 표준화)

  • 김동국;지정범
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.12
    • /
    • pp.1054-1059
    • /
    • 2002
  • A great deal of research has been done in the field of characterization for piezoelectric thin films after the first report on the measurement for the piezoelectric coefficient of thin films in 1990. The main idea of this research is to provide a distinctive solution for the measurement and standardization of both the longitudinal and the transverse piezoelectric d-coefficients, d33 and d31, of ferroelectric thin films. In general, to get these two coefficients of thin films, two different measuring systems are required. Here, we propose the improved method for the evaluation of these two coefficients with single equipment and with the relatively convenient procedure. The two-step loading process of applying the both positive and the negative pressure has been introduced to acquire the piezoelectric coefficients. These results have been calibrated for both the longitudinal and 4he transverse piezoelectric d-coefficients, d33 and 431, of thin films by comparison with the virtual standard created from FEM. In this experiments, we have obtained d33 of 331pC/N and 031 of -92.2pC/N for the PZT thin films.

Localization of Mobile Robot Based on Radio Frequency Identification Devices (RFID를 이용한 이동로봇의 위치인식기술)

  • Lee Hyun-Jeong;Choi Kyu-Cheon;Lee Min-Cheol;Lee Jang-Myung
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.12 no.1
    • /
    • pp.41-46
    • /
    • 2006
  • Ubiquitous location based services, offer helpful services anytime and anywhere by using real-time location information of objects based on ubiquitous network. Particularly, autonomous mobile robots can be a solution for various applications related to ubiquitous location based services, e.g. in hospitals, for cleaning, at airports or railway stations. However, a meaningful and still unsolved problem for most applications is to develop a robust and cheap positioning system. A typical example of position measurements is dead reckoning that is well known for providing a good short-term accuracy, being inexpensive and allowing very high sampling rates. However, the measurement always has some accumulated errors because the fundamental idea of dead reckoning is the integration of incremental motion information over time. The other hand, a localization system using RFID offers absolute position of robots regardless of elapsed time. We construct an absolute positioning system based on RFID and investigate how localization technique can be enhanced by RFID through experiment to measure the location of a mobile robot. Tags are placed on the floor at 5cm intervals in the shape of square in an arbitrary space and the accuracy of position measurement is investigated . To reduce the error and the variation of error, a weighting function based on Gaussian function is used. Different weighting values are applied to position data of tags since weighting values follow Gaussian function.

Characterization of Piezoelectric Thin Films (압전박막의 특성평가)

  • 김동국;변금효;김일두;이치헌;박정호;최광표;김호기
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.916-919
    • /
    • 2000
  • A great deal of research has been done in the field of characterization for piezoelectric thin films after the first report on the measurement for the piezoelectric coefficient of thin films in 1990. The main idea of this research is to provide a distinctive solution for the measurement of both the longitudinal and the transverse piezoelectric d-coefficients, d$\sub$33/ and d$\sub$3l/, of ferroelectric thin films and also thick films. In general, to get these two coefficients of thin films, two different measuring systems are required. Here, we propose the improved method for the evaluation of these two coefficients with single equipment and with the relatively convenient procedure. The two-step loading process of applying the both positive and the negative pressure has been designed to acquire the piezoelectric coefficients. These results have beer calibrated for both the longitudinal and the transverse piezoelectric d-coefficients, d$\sub$33/ and d$\sub$31/, of thin films. In the first stage of the experiments, we have obtained d$\sub$33/ of 108pC/N and d$\sub$31/ of 57pC/N for the PZT thin films.

  • PDF

New Approach of Evaluating Poomsae Performance with Inertial Measurement Unit Sensors (관성센서를 활용한 새로운 품새 경기력 평가 방법 연구)

  • Kim, Young-Kwan
    • Korean Journal of Applied Biomechanics
    • /
    • v.31 no.3
    • /
    • pp.199-204
    • /
    • 2021
  • Objective: The purpose of this study was to present a new idea of methodology to evaluate Poomsae performance using inertial measurement unit (IMU) sensors in terms of signal processing techniques. Method: Ten collegian Taekwondo athletes, consisting of five Poomsae elite athletes (age: 21.4 ± 0.9 years, height: 168.4 ± 11.3 cm, weight: 65.0 ± 10.6 kg, experience: 12 ± 0.7 years) and five breaking demonstration athletes (age: 21.0 ± 0.0 years, height: 168.4 ± 4.7 cm, weight: 63.8 ± 8.2 kg, experience: 13.0 ± 2.1 years), voluntarily participated in this study. They performed three different black belt Poomsae such as Goryeo, Geumgang, and Taebaek Poomsae repeatedly twice. Repeated measured motion data on the wrist and ankle were calculated by the methods of cosine similarity and Euclidean distance. Results: The Poomsse athletes showed superior performance in terms of temporal consistency at Goryeo and Taebaek Poomsae, cosine similarity at Geumgang and Taebaek Poomsae, and Euclidian distance at Geumgang Poomsae. Conclusion: IMU sensor would be a useful tool for monitoring and evaluating within-subject temporal variability of Taekwondo Poomsae motions. As well it distinguished spatiotemporal characteristics among three different Poomsae.

A Study of the Improvement and Practical Use on the Website Measurement Scale (웹사이트 측정도구의 개발과 활용에 대한 연구)

  • Kim, Dae-Hwan;Bae, Young
    • Survey Research
    • /
    • v.10 no.1
    • /
    • pp.91-112
    • /
    • 2009
  • The aim of this study is to suggest a new website measurement scale revised in accordance with the present tendency, and to test the practical use of it. The empirically current studies suggest the information, connectivity, practical function, lay - out, design, interlace, system, service as a website measurement scale. However. this study suggest a new website measurement scale including communication between internet users, platform for editing information. The test of a practical use about measurement scale progressed by a survey on computer access. A sample of 300 internet users answered the question based on a new website measurement scale. The result of this study shows that primary factors of the website measurement scale are information, user interface, website service, and communication. The influence of these factors on user's website preference changed as compared with the past. The result also shows that there is close correlation between information factor and communication factor. And the communication factor suggested on this study has effected in user's website satisfaction. Results imply that the idea of web2.0 is practically an important strategy for improving website satisfaction. And, because influence of primary factors on the website satisfaction has changed continually, strategic planning will have to be kept up.

  • PDF