• 제목/요약/키워드: hysteretic damper

검색결과 123건 처리시간 0.026초

비선형 히스테리시스 진동시스템의 분기해석 (Bifurcation Analysis of a Non-linear Hysteretic Oscillating System)

  • 장서일;송덕근;최진권
    • 한국소음진동공학회논문집
    • /
    • 제12권1호
    • /
    • pp.57-64
    • /
    • 2002
  • Three kinds of viscoelastic damper model, which has a non-linear spring as an element is studied analytically and numerically The behavior of the damper model shows non-linear hysteresis curves which is qualitatively similar to those of real viscoelastic materials. The motion is governed by a non-linear constitutive equation and an additional equation of motion. Harmonic balance method is applied to get analytical solutions of the system. The frequency-response curves sallow that multiple solutions co-exist and that the jump phenomena can occur. In addition, it is shown that separate solution branch exists and that it can merge with the primary response curve. Saddle-node bifurcation sets explain the occurrences of such non-linear Phenomena.

점탄성 댐퍼용 아크릴 방진고무의 개발 및 특성시험 (Development and Characteristic Tests of Acrylic Rubber for Viscoelastic Dampers)

  • 박진일;정정교;박해동;김영찬;김두훈
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집A
    • /
    • pp.722-727
    • /
    • 2001
  • The dynamic characteristics of Viscoelastic(VE) damper are experimentally studied. An experimental test was carried out to study the effects of frequency on the damping and stiffness of VE damper. Various cyclic loading tests are conducted. A good agreement was achieved between the experimental results and analytical model proposed by Kasai et al. Also the damping of acrylic rubber is compared with that of PNR material. It was concluded that the damping value of acrylic rubber is higher than that of PNR material.

  • PDF

Experimental study on lead extrusion damper and its earthquake mitigation effects for large-span reticulated shell

  • Yang, M.F.;Xu, Z.D.;Zhang, X.C.
    • Steel and Composite Structures
    • /
    • 제18권2호
    • /
    • pp.481-496
    • /
    • 2015
  • A Lead Extrusion Damper (LED) is experimentally studied under various frequencies and displacement amplitudes. Experimental results show that the force-displacement hysteresis loops of the LED are close to rectangular and the force-velocity hysteresis loops exhibit nonlinear hysteretic characteristic. Also, the LED can provide consistent energy dissipation without any stiffness degradation. Based on the experimental results, a mathematical model is then proposed to describe the effects of frequency and displacement on property of LED. It can be proved from the comparison between experimental and numerical results that the mathematical model can accurately describe the mechanical behavior of LED. Subsequently, the seismic responses of the Schwedler reticulated shell structure with LEDs are analyzed by ANSYS software, in which three different installation forms of LEDs are considered. It can be concluded that the LED can effectively reduce the displacement and acceleration responses of this type of structures.

V형 강재댐퍼의 이력특성 평가 (Evaluation on Hysteretic Behaviors of V Shaped Metallic Dampers)

  • 이현호;김세일
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제15권1호
    • /
    • pp.254-262
    • /
    • 2011
  • 본 연구의 목적은 슬릿형 강재댐퍼보다 에너지 소산능력 등이 우수할 것으로 예상되는 V형 강재 댐퍼 개발에 있다. 이를 위하여 댐퍼 스트럿의 높이 및 각도에 대한 실험체 9개를 만들어 전단실험을 수행하였다. 실험결과, 스트럿 높이가 270mm이고, 스트럿 각도 $60^{\circ}$인 경우의 V형 강재댐퍼가 가장 우수한 내진성능 보유한 것으로 평가되었다. 또한 기존내력식을 이용한 댐퍼의 항복강도를 비교한 결과, 기존 실험결과를 분석한 범위 내에서 V형 댐퍼의 실험결과가 높게 평가되는 것으로 나타났다.

Real-time model updating for magnetorheological damper identification: an experimental study

  • Song, Wei;Hayati, Saeid;Zhou, Shanglian
    • Smart Structures and Systems
    • /
    • 제20권5호
    • /
    • pp.619-636
    • /
    • 2017
  • Magnetorheological (MR) damper is a type of controllable device widely used in vibration mitigation. This device is highly nonlinear, and exhibits strongly hysteretic behavior that is dependent on both the motion imposed on the device and the strength of the surrounding electromagnetic field. An accurate model for understanding and predicting the nonlinear damping force of the MR damper is crucial for its control applications. The MR damper models are often identified off-line by conducting regression analysis using data collected under constant voltage. In this study, a MR damper model is integrated with a model for the power supply unit (PSU) to consider the dynamic behavior of the PSU, and then a real-time nonlinear model updating technique is proposed to accurately identify this integrated MR damper model with the efficiency that cannot be offered by off-line methods. The unscented Kalman filter is implemented as the updating algorithm on a cyber-physical model updating platform. Using this platform, the experimental study is conducted to identify MR damper models in real-time, under in-service conditions with time-varying current levels. For comparison purposes, both off-line and real-time updating methods are applied in the experimental study. The results demonstrate that all the updated models can provide good identification accuracy, but the error comparison shows the real-time updated models yield smaller relative errors than the off-line updated model. In addition, the real-time state estimates obtained during the model updating can be used as feedback for potential nonlinear control design for MR dampers.

강봉댐퍼로 보강한 기존 저층 철근콘크리트 필로티 건물의 내진성능 (Seismic Performance of an Existing Low-Rise Reinforced Concrete Piloti Building Retrofitted by Steel Rod Damper)

  • 백은림;오상훈;이상호
    • 한국지진공학회논문집
    • /
    • 제18권5호
    • /
    • pp.241-251
    • /
    • 2014
  • In this study, shaking table test was carried out to evaluate the seismic behavior and performance of low-rise reinforced concrete (RC) piloti structures with and without retrofit. The specimens were designed considering the characteristics of existing building with pilotis such as natural period, distribution factor of strength and stiffness between columns and core wall on the first soft story. The test for the non-retrofit specimen showed that damage was concentrated on the stiffer member on the same floor as the core wall failed by shear fracture whereas columns experienced slight flexural cracks. Considering the failure mode of the non-retrofit specimen, the retrofit method using steel rod damper was presented for improving the seismic performance of piloti structures. The results of the test for retrofit specimen revealed that the retrofit method was effective for controlling the damage as the main RC structural members were not destroyed and most of input energy was dissipated by hysteretic behavior of the damper.

기둥 복합댐퍼의 해석모델 구축 및 기존 건축물에 대한 내진보강 효과분석 (Analytical Modelling of Column-Type Hybrid Damper and Seismic Rehabilitation of Existing Buildings)

  • 최기선;유영찬;김긍환;조해진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.285-288
    • /
    • 2008
  • 본 연구에서는 도심지 건축물의 개조 재활용을 위한 핵심 보강기술의 개발을 위하여 기존 건축물의 내진보강을 위한 새로운 개념의 기둥복합댐퍼를 제안하고, 그 적용 가능성을 타진하기 위한 해석적 연구를 수행하였다. 이를 위하여 먼저 기둥복합댐퍼의 이력특성을 고려할 수 있는 해석모델을 구축하고, 상용화 구조해석 프로그램(MIDAS-Gen)에 적용할 수 있는 모델링 기법을 개발하였다. 이와 같이 개발된 기둥복합댐퍼를 이용하여 수직증축을 상정한 기존 건축물의 내진보강을 실시하고 개발된 해석모델링 기법을 적용하여 시간이력해석에 의해 보강 전/후의 효과를 검토하였다. 본 구조해석 결과에 의하면, 기둥복합댐퍼의 보강에 의해 보강되지 않은 구조물에 비하여 밑면전단력이 약 20% 정도 감소하였으며, 임계층에서의 층간변위가 20% 정도 감소하는 결과를 얻을 수 있었다.

  • PDF

A ductile steel damper-brace for low-damage framed structures

  • Javidan, Mohammad Mahdi;Kim, Jinkoo
    • Steel and Composite Structures
    • /
    • 제44권3호
    • /
    • pp.325-337
    • /
    • 2022
  • In this research, an earthquake-resistant structural system consisting of a pin-connected steel frame and a bracing with metallic fuses is proposed. Contrary to the conventional braced frames, the main structural elements are deemed to remain elastic under earthquakes and the seismic energy is efficiently dissipated by the damper-braces with an amplification mechanism. The superiority of the proposed damping system lies in easy manufacture, high yield capacity and energy dissipation, and an effortless replacement of damaged fuses after earthquake events. Furthermore, the stiffness and the yield capacity are almost decoupled in the proposed damper-brace which makes it highly versatile for performance-based seismic design compared to most other dampers. A special attention is paid to derive the theoretical formulation for nonlinear behavior of the proposed damper-brace, which is verified using analytical results. Next, a direct displacement-based design procedure is provided for the proposed system and an example structure is designed and analyzed thoroughly to check its seismic performance. The results show that the proposed system designed with the provided procedure satisfies the given performance objective and can be used for developing highly efficient low-damage structures.

고감쇠고무와 강재슬릿의 복합 댐퍼로 보강한 건축물의 해석적 성능평가 (Analytical Performance Evaluation of Structure Reinforced with HRS Damper)

  • 김유성;이준호
    • 한국공간구조학회논문집
    • /
    • 제22권4호
    • /
    • pp.31-38
    • /
    • 2022
  • In this study, an incremental loading test of the HRS(Hybrid Rubber Slit) damper was additionally performed to define the physical characteristics according to the incremental test results, and an analytical study was performed according to the damping design procedure by selecting an example structure. As a result of performing seismic performance evaluation before reinforcement by selecting a RC structure similar to an actual school structure as an example structure, the story drift ratio was satisfied, but some column members collapsed due to bending deformation. In order to secure the seismic performance, the damping design procedure of the HRS damper was presented and performed. As a result of calculating the amount of damping device according to the expected damping ratio and applying it to the example structure, the hysteresis behavior was stable without decrease in strength, and the story drift ratio and the shear force were reduced according to the damping effect. Finally the column members that had collapsed before reinforcement satisfied the LS Level.

Experimental and analytical investigations on seismic behavior of ductile steel knee braced frames

  • Zahrai, Seyed Mehdi;Jalali, Meysam
    • Steel and Composite Structures
    • /
    • 제16권1호
    • /
    • pp.1-21
    • /
    • 2014
  • Knee Braced Frame (KBF) is a special form of ductile eccentrically braced frame having a diagonal brace connected to a knee element, as a hysteretic damper, instead of beam-column joint. This paper first presents an experimental investigation on cyclic performance of two knee braced single span one-story frame specimens. The general test arrangement, specimen details, and most relevant results (failure modes and hysteretic curves) are explained. Some indexes to assess the seismic performance of KBFs, including ductility; response reduction factor and energy dissipation capabilities are also subsequently discussed. Experimental results indicate that the maximum equivalent damping ratios achieved by test frames are 21.8 and 23% for the specimens, prior to failure. Finally, a simplified analytical model is derived to predict the bilinear behavior of the KBFs. Acceptable conformity between analytical and experimental results proves the accuracy of the proposed model.