• 제목/요약/키워드: hydraulic head

검색결과 377건 처리시간 0.028초

콤플렉스법에 의한 롤러-링크 부착형 전도수문 구동용 유압실린더의 최적 설치점 설계 (Design of Optimal Locating Point of the Hydraulic Cylinder Actuating a Roller-Link Type Rotating Floodgate)

  • 이성래
    • 드라이브 ㆍ 컨트롤
    • /
    • 제9권3호
    • /
    • pp.29-36
    • /
    • 2012
  • The hydraulic cylinder is used for actuating the roller-link type rotating floodgate which controls the volume of water in the reservoir. The locating points of hydraulic cylinder are restricted to the limited space and determined to minimize the cylinder force necessary for actuating the floodgate. Generally, the head end point of cylinder is fixed at underground and the rod end point of cylinder is connected to the support link. Therefore there exist three design variables to be determined to minimize the cylinder force within the rotating range of floodgate. First, the mathematical model of the roller-link type rotating floodgate is derived to find the cylinder force corresponding to the floodgate angle. Then, the optimal locating point of hydraulic cylinder is searched using the complex method that is one kind of constrained direct search method.

컴플렉스법에 의한 수문 유압실린더의 최적 설치점 설계 (Design of Optimal Locating Points of the Hydraulic Cylinder Actuating a Sluice Gate Using the Complex Method)

  • 이성래
    • 한국자동차공학회논문집
    • /
    • 제13권6호
    • /
    • pp.170-176
    • /
    • 2005
  • The hydraulic cylinder is used for actuating the sluice gate which controls the volume of water in the reservoir. The locating points of hydraulic cylinder are restricted to limited space and determined to minimize the cylinder force necessary for actuating the sluice gate. Generally, the head end point of cylinder is fixed at underground and the rod end point of cylinder is connected to the gate plate when it is fully opened. Therefore there exist three parameters to be determined to minimize the cylinder force in the operation range of sluice gate. The optimal locating points of hydraulic cylinder are obtained using the complex method that is one kind of constrained direct search m method.

직사각형 맨홀의 내부형상변화에 따른 흐름특성 분석 (An Analysis of Flow Characteristics with Changing the Inside Shapes in Square Manhole)

  • 장석진;윤영노;김정수;윤세의
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2007년도 정기총회 및 학술발표대회
    • /
    • pp.199-202
    • /
    • 2007
  • In storm sewer networks a lot of manholes are installed to maintain and connect a sewer of urban area. There are some shapes of manhole such as circular type, square type, and so on. Square shape manholes are installed to connect the large diameter drainage pipes in general and have lager head losses than circular one. Consequently, it is important to analyze the head losses in square manhole because the head losses in square manhole are much bigger than the friction losses in pipes. Hydraulic experimental apparatus which can be changed the inside shape in square manhole was installed for this study. The experimental discharge was $16{\ell}/sec$. The head loss coefficients in the manhole were calculated by the experimental results. The range of head loss coefficients in the general square manhole were from 0.33 to 0.48 and the range of head loss coefficients in the square manhole changed inside shape were from 0.23 to 0.28.

  • PDF

결정질 암반내 지하연구시설에서 수행한 현장수리시험법 적용성 연구 (A Study on the Applicability of the Hydraulic Test Method Performed at an underground Research Facility in Crystalline Rock)

  • 박경우;고낙열;지성훈
    • 자원환경지질
    • /
    • 제53권2호
    • /
    • pp.121-131
    • /
    • 2020
  • 본 논문에서는 지하연구시설에서 결정질 암반의 수리지질특성을 도출하기 위해 일반적으로 수행하는 수리시험법의 적용 가능성 및 신뢰성을 평가할 목적으로, 펄스시험, 슬러그시험과 정압시험을 이용하여 각 시험 결과로부터 도출되는 투수량계수를 서로 비교해 보았다. 펄스시험과 슬러그시험의 결과를 비교해 볼 때, 매질의 투수성이 낮은 시험 구간에서는 투수량계수가 매우 유사하게 도출되었지만, 투수성이 비교적 큰 구간에서는 다소 차이를 보였다. 그리고 투수성이 큰 구간에서 정압시험 결과에 비해 순간수위변화시험의 결과가 다소 크게 나타났다. 이러한 투수성의 차이는 각 수리시험에서 적용되는 수리 영향 반경의 상이함에 기인한 것으로 판단된다. 비록 각각의 현장수리시험에서 도출되는 결과가 매질의 투수성을 동일하게 반영한다고 할 수는 없지만, 단열의 불균질한 분포가 투수성에 영향을 주는 결정질 암반에서의 수리지질특성을 도출할 때 수리영향반경이 큰 정압시험이나 정률시험뿐만 아니라 비교적 빠른 시간에 수리지질특성을 파악할 수 있는 슬러그시험과 펄스시험을 통해서도 매질의 수리지질특성을 설명할 수 있는 것으로 사료된다.

연직차수벽의 비정상 지하수 흐름에 대한 이론해 : 순간변위시험(slug test) 적용과 투수계수 산정 (Analytical Solution for Transient Groundwater Flow in Vertical Cutoff Walls : Application of Slug Test and Evaluation of Hydraulic Conductivity)

  • 임지희;이동섭;웽 테 바오;최항석
    • 한국지반공학회논문집
    • /
    • 제28권11호
    • /
    • pp.17-31
    • /
    • 2012
  • 순간변위시험(slug test) 결과를 이용하여 비정상 흐름을 고려한 연직차수벽의 투수계수를 평가할 수 있는 이론해는 지금까지 제시된 바가 없다. 무한 대수층에 부분 관입된 우물(well)형상에 적용 가능하도록 기존 문헌에서 제시한 이론해는 좁은 지중연속벽체 형상의 연직차수벽의 경계조건을 고려할 수 없다. 이러한 연직차수벽 경계조건을 고려하기 위해, 본 연구에서는 가상 우물이론(imaginary well theory)을 도입하여 두 가지 경계조건(즉, 일정 수두 조건과 불투수 조건)을 만족하도록 새로운 이론해를 유도하였다. 제안된 이론해를 이용하여 구한 연직차수벽에서 시간에 따른 수위 회복 곡선(Type Curve)을 무한 대수층의 경우와 비교한 결과, 일정 수두 경계조건을 적용할 경우, 우물의 수위 회복이 무한 대수층의 결과보다 빠르게 진행되고 반면에 불투수 경계조건을 적용할 경우는 더 느리게 진행되었다. 또한, 우물의 형상비가 클수록, 연직차수벽의 폭이 좁을수록, 우물의 편심 정도가 클수록, 연직차수벽과 주변 지반 사이의 경계조건의 영향이 커진다. 본 논문에서 제시한 이론해를 통해 산정된 Type Curve는 기존 문헌에서 수치해석을 통해 산정된 Type Curve와 유사한 경향을 보였다.

연속 맨홀에서의 손실계수 산정 (An Estimation of Head Loss Coefficients at Continuous Circular Manhole)

  • 윤영노;김정수;한정석;윤세의
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2008년도 정기총회 및 학술발표대회
    • /
    • pp.731-734
    • /
    • 2008
  • Urban sewer systems are designed to operate in open-channel flow regime and energy loss at circular manholes are usually not significant. However, the energy loss at manholes, often exceeding the friction loss of pipes under surcharge flow, is considered as one of the major causes of inundation in urban area. Therefore, it is necessary to analyze the head loss associated with manholes, especially in surcharge flow. Hydraulic experimental apparatus with two circular manholes was installed for this study. The range of the experimental discharges were from $1.0\ell/sec$ to $4.4\ell/sec$. Head loss coefficient was maximum because of strong oscillation of water surface when the range of manhole depth ratios$(h_m/D_{in})$ were from 1,2 to 1.25. The average head loss coefficients for upstream manhole and downstream manhole were 0.58 and 0.23 respectively. Head loss at upstream manhole is nearly 2.5 times more than one at downstream manhole.

  • PDF

사질토의 투수계수와 전기전도도 간의 상관관계 (Relationship between Hydraulic Conductivity and Electrical Conductivity in Sands)

  • 김진욱;추현욱;이창호;이우진
    • 한국지반공학회논문집
    • /
    • 제31권6호
    • /
    • pp.45-58
    • /
    • 2015
  • 본 연구에서는 이론적 고찰을 통해 Kozeny-Carman식을 변형하여 전기전도도 측정을 통한 사질토의 투수계수 추정식을 제안하였다. 제안된 예측식에 대한 실험적 검증을 위해 6종류의 사질토에 대하여 4개의 전극을 설치한 정수위 투수시험을 실시하였으며, 다양한 변수들 하에 시험을 진행하였다. 시험 결과, 사질토에서 흙 입자 표면을 통한 전기전도는 미미하였으며, 간극수의 전기전도도가 투수계수와 formation facotor에 미치는 영향은 제한적이었다. 흙 입자의 유효입경이 formation factor에 미치는 영향은 미미하였으나 투수계수에는 큰 영향을 주었다. 제안된 식을 활용하여 투수계수를 예측하기 위해서는 형상계수와 Archie's m에 대한 정보가 필요하여 error norm방법을 사용해 형상계수를 구하였다. 또한, 간극률을 변화시키며 측정된 formation factor를 사용하여 Archie's m을 구하였다. formation factor를 사용하여 계산한 투수계수를 측정값과 같이 도시한 결과, 계산된 투수계수는 측정된 투수계수와 유사한 값을 보여주었다. 기존 Kozeny-Carman식과 본 연구에서 제안하는 전기전도도를 이용한 투수식 간의 정량적인 비교를 위해, 정규화된 투수계수를 사용하여 형상계수, Archie's m, 간극률에 따른 정규화된 투수계수의 변화를 비교한 결과, 형상계수와 Archie's m의 변화에 따른 정규화된 투수계수의 변화 폭에 비해, 간극률의 변화에 따른 정규화된 투수계수는 매우 큰 폭으로 변하였다. 따라서 본 연구에서 제안하는 전기전도도를 이용한 투수계수 예측식이 기존 Kozeny-Carman식보다 더 높은 신뢰도를 보일 것으로 판단된다.

낙동강변 실트질 모래의 수리전도도와 전기적 물성과의 관계 (A Relationship between Hydraulic Conductivity and Electrical Properties of Silty Sand on the Riverside of the Nakdong River)

  • 김수동;박삼규;함세영;오윤영
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제19권3호
    • /
    • pp.39-46
    • /
    • 2014
  • Hydraulic conductivity is an important parameter, representing permeable property of the groundwater in aquifers, in the issues of groundwater development, groundwater contamination, and groundwater flow, etc. We estimated a relationship between hydraulic conductivity and electrical properties (formation factor, chargeability, and time constant) of silty sand in the laboratory. For this study, we conducted grain size analysis, constant head permeameter test, and measured electrical resistivity and spectral induced polarization of silty sand samples collected from the riverside alluvium of the Nakdong River in Nogok-ri area, Dasan-myeon, Goryeong-gun in Gyeongbook Province, Korea. In the laboratory test, we used soil samples of approximately uniform porosity with 0.5% error range, and kept the electrical resistivity of pore water with 100 ohm-m. As a result, the relationship between effective particle size and hydraulic conductivity agrees fairly well with the existing empirical formulas. Hydraulic conductivity was correlated with formation factor, chargeability, and time constant: hydraulic conductivity increased with increasing formation factor and time constant as well as with decreasing chargeability.

사류펌프 내 삼차원 유동의 수치해석 (NUMERICAL ANALYSIS OF THREE-DIMENSIONAL FLOW IN A MIXED-FLOW PUMP)

  • 안형진;김진혁;김광용
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2009년 춘계학술대회논문집
    • /
    • pp.223-226
    • /
    • 2009
  • This paper presents three-dimensional flow analysis for a mixed-flow pump which consists of a rotor and a stator. Reynolds-averaged Navier-Stokes equations with shear stress transport turbulence model are discretized by finite volume approximations and solved by the commercial CFD code CFX 11.0. Structured grid system is constructed in the computational domain, which has O-type grids near the blade surfaces and H-type grids in other regions. Validation of the numerical results was performed with experimental data for head coefficients and hydraulic efficiencies at different flow coefficients. This paper shows that the pump characteristics can be predicted effectively by numerical analysis.

  • PDF

프란시스수차의 국산화개발 연구 (R&D of Francis Type Hydro Turbine for Domestic Production)

  • 이철형;박완순
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 춘계학술발표대회 논문집
    • /
    • pp.302-305
    • /
    • 2009
  • The Francis type hydro turbine with vertical axis has been designed and analized for hydraulic performance verification. The guide vane angle of turbine casing were designed to be varied according to the condition of head and flowrate. When the changes in flowrate and output were comparatively large, the efficiency drop were small, so the efficiency characteristics and stability of the entire operating condition were maintained in good condition. These results showed that the developed hydro turbine in this study will be suitable for small hydro power stations with medium and high head such as agricultural reservoirs and large dam.

  • PDF