• Title/Summary/Keyword: hydraulic efficiency

Search Result 915, Processing Time 0.025 seconds

Estimation of Kinetic Coefficient in Submerged Membrane Bioreactor for Biological Nutrient Removal (도시 하수의 생물학적 고도처리를 위한 분리막 공정의 개발 및 동역학적 계수 산정 연구)

  • Park, Jong-Bu;Park, Seung-Kook;Hur, Hyung-Woo;Kang, Ho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.2
    • /
    • pp.109-113
    • /
    • 2009
  • This study was performed to investigate the characteristics of nutrient removal of municipal wastewater in membrane bioreactor system. Membrane bioreactor consists of four reactors such as the anaerobic, the stabilization, the anoxic and the submerged membrane aerobic reactor with two internal recycles. The hydraulic retention time (HRT), sludge retention time (SRT) and flux were 6.2 h, 34.1 days and 19.6 L/$m^2$/hr (LMH), respectively. The removal efficiency of $COD_{Cr}$, SS, TN and TP were 94.3%, 99.9%, 69.4%, and 74.6%, respectively. The estimated true biomass yield, specific denitrification rate (SDNR), specific nitrification rate (SNR), specific phosphorus release rate (SPRR) and specific phosphorus uptake rate (SPUR) were 0.653 kgVSS/kgBOD/d, 0.044 $mgNO_3$-N/mgVSS/d, 0.035 $mgNH_4$-N/mgVSS/d, 51.0 mgP/gVSS/d and 5.4 mgP/gVSS/d, respectively. The contents of nitrogen and phosphorus of biomass were 8.86% and 3.5% on an average.

Anaerobic Treatment of Leachate Solubilized from Thermal Hydrolysis of Sludge Cake (하수슬러지 케이크 열수분해 탈리액의 혐기성 분해 특성)

  • Kang, Ho;Oh, Baik-Yong;Shin, Kyung-Sook
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.10
    • /
    • pp.583-589
    • /
    • 2015
  • This study was performed to evaluate the feasibility of anaerobic pretreatment for the leachate solubilized from thermal hydrolysis of sewage sludge cake. Overall process for the treatment of sludge cake consists of thermal hydrolysis, crystallization of magnesium, ammonium, and phosphate (MAP) for the leachate and anaerobic digestion of supernatant from MAP crystallization. The experimental evidence showed that the optimum ratio of Mg : P for the struvite crystallization of leachate solubilized from thermal hydrolysis of sludge cake was 1.5 to 1.0 as weight basis at the pH of 9.5. With this operational condition, the removal efficiencies of ammonia nitrogen and phosphorous achieved 50% and 97%, respectively. The mesophilic batch test showed that the ultimate biodegradability of the supernatant from MAP crystallization reached 63% at S/I ratio of 0.5. The readily biodegradable fraction of 90% ($S_1$) of the MAP supernatant BVS (Biodegradable Volatile Solids, $S_0$) degraded with $k_1$ of $0.207day^{-1}$ for the initial 17 days where as the rest slowly biodegradable fraction ($S_2$) of 10% of BVS degraded with $k_2$ of $0.02day^{-1}$ for the rest of the operational period. Semi-Continuously Fed and Mixed Reactor (SCFMR) was chosen as one of the best candidates to treat the MAP supernatant because of its total solids content over 6%. Maximum average biogas production rates reached 0.45 v/v-d and TVS removal efficiency of 37~41% was achieved at an hydraulic retention time (HRT) of 20 days and its corresponding organic loading rate (OLR) of 1.43 g VS/L-d.

Ammonia Removal by using RBC in Recirculating Aquaculture System (RBC를 이용한 양어장수 암모니아 제거)

  • KIM Byong-Jin;LIM Sung-Il;SUH Kuen-Hack
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.31 no.5
    • /
    • pp.622-630
    • /
    • 1998
  • Rotating Biological Contactor (RBC) was tested for the removal of total ammonia nitrogen (TAN) by using simulated aquaculture system. RBC performance was evaluated by controlling revolution rate of disk and hydraulic residence tile (HRT). The optimum revolution rate of disk was 4 rpm, As HRT of RBC was increased, TAN removal efficiency of RBC and TAN concentration of rearing water were increased. HRT for maintaining lowest TAN concentration of rearing water was 9.5 minutes and at that condition TAN concentration of rearing tank was $1.03 g/m^3$

  • PDF

Vertical Flow Zeolite-Filled Reed Bed with Intermittent Feeding for Sewage Treatment (수직 흐름 제올라이트 갈대 여과상에 의한 생활하수 처리)

  • Seo, Jeoung-Yoon
    • KSBB Journal
    • /
    • v.22 no.2
    • /
    • pp.102-108
    • /
    • 2007
  • A sewage was treated using a vertical flow zeolite-filled reed bed. The sewage from the student dormitory of Changwon National University was fed into the reed bed for 10 minutes every 6 hours at the hydraulic load of $314L/m^3{\cdot}$day. The filtering height of the reed bed was 100 em and the zeolite mixture was filled in the reed bed. The mixture consisted of the same volume of two types of zeolite: 0.5$\sim$1 mm and 1$\sim$3 mm in diameter. Annual average removal efficiency was 88 89.9%, $COD_{Cr}$ 86.1 %, $COD_{Mn}$ 81.2%, T-N 34.0%, $NH_4^+$-N 97.3% and T-P 34.6%. T-N of effluent was mostly $NO_3^-$-N and the concentration of $NO_2^-$-N in effluent was lower than 0.1 mg/L. All removal efficiencies did not show a remarkable seasonal change. The ranking of phosphorous fractions fixed to the zeolite in column test was Ca-P > Fe-P > reductant soluble Fe-P > occluded P > saloid P > AI-P at all depths of the filter. All phosphorous fractions except for AI-P reduced at deeper filter layer, while their content ratios increased at deeper filter layer. Organic matter content was the highest at the highest layer (0$\sim$5 cm from the top of the filter) and only small differences were observed at the deeper filter layer than 5 em from the top. Organic matter content increased at all depths of the filter with the operating time.

A Study of the Fluidic Characteristics of High-Pressure Fuel Pumps for GDI Engines (GDI 고압펌프의 유동특성에 관한 연구)

  • Lee, Sangjin;Noh, Yoojeong;Liu, Hao;Lee, Jae-Cheon;Shin, Yongnam;Park, Yongduk;Kang, Myungkweon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.5
    • /
    • pp.455-461
    • /
    • 2015
  • A high-pressure fuel pump is a key component in a gasoline direct injection (GDI) engine; thus, understanding its flow characteristics is essential for improving the engine power and fuel efficiency. In this study, AMESim, which is a hydraulic analysis program, was used to analyze the performance of the high-pressure fuel pump. However, since AMESim uses a one-dimensional model for the system analysis, it does not accurately analyze the complicated flow characteristics. Thus, Fluent, computational fluid dynamics (CFD) software, was used to calculate the flow rates and net forces at the intake and discharge ports of the high-pressure fuel pump where turbulent flow occurs. The CFD analysis results for various pressure conditions and valve lifts were used as look-up tables for the AMEsim model. The CFD analysis results complemented the AMEsim results, and thus, improved the accuracy of the performance analysis results for the high-pressure fuel pump.

IP Modeling and Inversion Using Complex Resistivity (복소 전기비저항을 이용한 IP 탐사 모델링 및 역산)

  • Son, Jeong-Sul;Kim, Junhg-Ho;Yi, Myeong-Jong
    • Geophysics and Geophysical Exploration
    • /
    • v.10 no.2
    • /
    • pp.138-146
    • /
    • 2007
  • This paper describes 2.5D induced polarization (IP) modeling and inversion algorithms using complex resistivity. The complex resistivity method has merits for acquiring more valuable information about hydraulic parameters and pore fluid than the conventional IP methods. The IP modeling and inversion algorithms are developed by allowing complex arithmetic in existing DC modeling and inversion algorithms. The IP modeling and inversion algorithms use a 2.5D DC finite-element algorithm and a damped least-squares method with smoothness constraints, respectively. The accuracy of the IP modeling algorithm is verified by comparing its responses of two synthetic models with two different approaches: linear filtering for a three-layer model and an integral equation method for a 3D model. Results from these methods are well matched to each other. The inversion algorithm is validated by a synthetic example which has two anomalous bodies, one is more conductive but non-polarizable than the background, and the other is polarizable but has the same resistivity as the background. From the inverted section, we can cleary identify each anomalous body with different locations. Furthermore, in order to verify its efficiency to the real filed example, we apply the inversion algorithm to another three-layer model which includes phase anomaly in the second layer.

Filter Media Specifications for Low Impact Development: A Review of Current Guidelines and Applications (LID 시설 여재에 관한 기술지침 및 적용에 관한 고찰)

  • Guerra, Heidi B.;Kim, Lee-Hyung;Kim, Youngchul
    • Journal of Wetlands Research
    • /
    • v.21 no.4
    • /
    • pp.321-333
    • /
    • 2019
  • A primary aspect of low impact development (LID) design that affects performance efficiency, maintenance frequency, and lifespan of the facility is the type of filter media as well as the arrangement or media profile. Several LID guidelines providing media specifications are currently available and numerous studies have been published presenting the effectiveness of these systems. While some results are similar and consistent, some of them still varies and only a few focuses on the effect of filter media type and arrangement on system performance. This creates a certain level of uncertainty when it comes to filter media selection and design. In this review, a synthesis of filter media specifications from several LID design guidelines are presented and relevant results from different laboratory and field studies are highlighted. The LID systems are first classified as infiltration or non-infiltration structures, and vegetated or non-vegetated structures. Typical profiles of the media according to classification are shown including the different layers, materials, and depth. In addition, results from previous studies regarding the effect of filter media characteristics on hydraulic and hydrologic functions as well as pollutant removal are compared. Other considerations such as organic media leaching, clogging, media washing, and handling during construction were also briefly discussed. This review aims to provide a general guideline that can contribute to proper media selection and design for structural LIDs. In addition, it also identifies opportunities for future research.

Analysis of Influence Factors for Remediation of Contaminated Soils Using Prefabricated Vertical Drains (연직배수재를 이용한 오염지반 복원의 영향인자 분석)

  • Park, Jeongjun;Shin, Eunchul
    • Journal of the Korean GEO-environmental Society
    • /
    • v.9 no.2
    • /
    • pp.39-46
    • /
    • 2008
  • Due to the growth in industrialization, potential hazards in subsurface environments are becoming increasingly significant. The extraction of the contaminant from the soil and movement of the water are restricted due to the low permeability and adsorption characteristics of the reclaimed soils. There are a number of approaches to in-situ remediation that are used in contaminated sites for removing contaminants. These include soil flushing, dual phase extraction, and soil vapor extraction. Among these techniques, soil flushing was the focus of the investigation in this paper. Incorporated technique with PVDs has been used for dewatering from fine-grained soils for the purpose of ground improvement by means of prefabricated vertical drain systems. The laboratory model tests were performed by using the flushing tracer solutions for silty soils and recorded the tracer concentration changes with the elapsed time and flow rates. The modeling was intended to predict the effectiveness and time dependence of the remediation process. Modeling has been performed on the extraction, considering tracer concentration and laboratory model test characteristics. The computer model used herein are SEEP/W and CTRAN/W, this 2-D finite element program allows for modeling to determine hydraulic head and pore water pressure distribution, efficiency of remediation for the subsurface environment. It is concluded that the coefficient of permeability of contaminated soil is related with vertical velocity and extracted flow rate. The vertical velocity and extracted flow rate have an effect on dispersivity and finally are played an important role in-situ soil remediation.

  • PDF

Treatment of Dairy Wastewater by the Combination of RBC and tapered Aeration (RBC와 점감포기조의 복합구성에 따른 유가공폐수 처리에 관한 연구)

  • Lee, Sang-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.6
    • /
    • pp.1733-1738
    • /
    • 2008
  • The treatment efficiency of rotating biological contactors (RBCs) for the high strength of dairy wastewater was investigated. Two different systems were conducted composing of a single RBC with tapered aeration reactors for the system A and a sequential RBCs following tapered aeration reactors for the system B. Experiments using dairy wastewater were conducted for 50 days period of time, in which hydraulic rates were maintained at the constant ratios of 346L per day and variable BOD concentrations were at the range from 1,358mg/L to 829mg/L, the $COD_{cr}$, concentration of the range were from 2,384mg/L to 1,329mg/L, the range of T-N concentrations was from 66mg/L to 38mg/L, and 50% of internal recycle and 50% of sludge return were performed. Results indicated that the removal efficiencies of the system B were higher than those of the system A. The removal efficiencies of system A for the BOD, $COD_{cr}$, T-N and T-P were 97.8%, 96.7%, 87.2% and 82%, respectively. The removal efficiencies of system B for the BOD, $COD_{cr}$, T-N and T-P were as of 98.5%, 98.5%, 91.3% and 89%.

Experimental Investigation of Water Discharge Capability According to Shape of Sluice for Tidal Power Generation - I. Physical Experiment (조력발전용 수문 형상에 따른 통수성능에 관한 실험적 연구 - I. 수리모형실험)

  • Lee, Dal-Soo;Oh, Sang-Ho;Yi, Jin-Hak;Park, Woo-Sun;Cho, Hyu-Sang;Kim, Duk-Gu
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.20 no.1
    • /
    • pp.73-80
    • /
    • 2008
  • An hydraulic experiment was carried out in an open channel flume in order to improve the technique of designing shape of the sluice used for tidal power generation, which greatly affects the economical efficiency of the construction of a tidal power plant. To predict the influence of change in the major design parameters relating to the sluice shape on the water discharge capability of the sluice, it was necessary to perform a precise experiment that is discriminated to previous feasibility studies or design projects. For this purpose, by installing various flow straighteners and rectifying structures inside the water supply system and the rectifying tank, the flow in the flume was stabilized as tranquil as possible. In addition, the measuring instruments and the location of installing them were carefully determined so as to minimize the errors intervened during the measurement of water discharge and water level. The method of estimating head difference between upstream and downstream of the sluice was also developed by taking account of the head loss due to the friction at the bottom and side walls in the flume.