• Title/Summary/Keyword: hydraulic efficiency

Search Result 915, Processing Time 0.026 seconds

Analysis of Hydraulic Passage Efficiency of Ice-Harbor Type Fishway for Flowrate Change (유량변화에 따른 아이스하버식 어도의 수리학적 이동효율 분석)

  • Jo, Jae An;Han, Eun Jin;Kim, Young Do;Baek, Kyong Oh
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.5
    • /
    • pp.1841-1850
    • /
    • 2013
  • The various types of fishways are installed at the multi-functional weirs in the four major rivers to minimize the negative effect due to the construction of the transverse structures. The movable weir was installed at the upstream of the ice-harbor type artificial fishway of the Dalseong weir in the Nakdong river, which can control the fishway flowrate regardless of the river flowrate. The incoming flowrate to the artificial fishway is closely related with the hydraulic characteristics that dominate the fish passage efficiency. Thus, it is crucial to find out the weir operation rule for properly sustaining efficient fish-passage, such as the optimized flowrate. In this study, the FLOW-3D was used to analyze and compare the various hydraulic characteristics associated with the passage efficiency, based upon the given different flowrate, and subsequently provide the optimized flowrate for the fishway movable weir to maintain the best efficient flow condition for the fish-passage.

Food Processing Wastewater Treatment with Ejector-Type Aerator (Ejector형 포기장치를 이용한 식품가공폐수를 처리)

  • 정용현
    • Journal of Environmental Science International
    • /
    • v.8 no.2
    • /
    • pp.221-225
    • /
    • 1999
  • This study was conducted to evaluate the treatment efficiency including reaction kinetics and hydraulic characteristics of food processing wastewater by using an ejector-type aeration system (ETAS) in activated sludge process. The oxygen transfer efficiency in ETAS can be changed in accordance with the depth of reactor. However, the optimum air velocity was found less than 1.82 m/hr at a superficial liquid velocity of 634 m/hr. The ETAS process showed higher organic material removal efficiency than that of the existing activated sludge process under hydraulic detention time 6 to 12 hours. This process, which can maintain MLVSS highly, is able to have high organic material removal efficiency at short HRT and deal with variable organic material loading.

  • PDF

Biological Removal Characteristics by the Internal Recycle Rate in the Attached Growth Process (부착증식공정에서 내부 반송율 변화에 따른 생물학적 제거 특성)

  • 박충기;김병욱;임재명
    • Journal of environmental and Sanitary engineering
    • /
    • v.14 no.4
    • /
    • pp.110-116
    • /
    • 1999
  • This study was conducted to investigate the contaminants removal efficiency and the optimal operating parameters by the internal recycle rate (IRR) in the combining A2/O process with fixed film. The average removal efficiency of BOD and COD was 92.5%~94.6%, 73.9%~87.0% in RUN 1 and 91.9%~94.7%, 77.7%~89.0% in RUN 2, respectively. Organic removal efficiency, at two different hydraulic retention time of 10 and 14hr, was similar. At 50% of the internal recycle rate, organic removal efficiency was somewhat higher than the other. Total nitrogen (T-N) and total phosphorus (T-P) were removed, highly, at 50% of internal recycle rate. It could be suggested by this study that the optimum internal recycle rate is 50% and hydraulic retention time is 14hr.

  • PDF

HYDRAULIC ANALYSIS OF OXYGEN TRANSFER THROUGH AIR ENTRAINMENT IN RIPARIAN RIFFLES

  • Kim, Jin-Hong
    • Water Engineering Research
    • /
    • v.4 no.3
    • /
    • pp.127-139
    • /
    • 2003
  • This paper presents the hydraulic analysis of the oxygen transfer through the air entrainment and the relationships between the efficiency of the oxygen transfer and the hydraulic parameters in the riparian riffles. Field survey on the pool-riffle formation of the river reach and the measurements of the oxygen transfer in the riffles were performed. Air entrainment occurred more frequently in the edged gravels rather than in the round and edgeless ones, and it was formed mainly from behind the trailing edges of the gravels. Oxygen transfer was found to be proportional to the flow velocity, the flow discharge, and the Froude number, but to be not closely related to the particle diameter. Average value of oxygen transfer in the riffles of study area was about 0.085, which shows good efficiency compared with results of smooth chute. Variation of the water level, which increases in proportion to the flow velocity and the flow discharge, seems to make the air entrainment more active, but has not been verified quantitatively. Relationships between the air entrainment and the variation of the water level must be considered in the further study.

  • PDF

Development of a Hydraulic Power Package Enclosed with an Electric Motor (모터 일체형 유압 파워 패키지의 개발)

  • Park, Y.H.;Lee, C.D.;Lee, J.K.
    • Journal of Power System Engineering
    • /
    • v.4 no.3
    • /
    • pp.55-61
    • /
    • 2000
  • In this study, a new design of an one-body type of an unbalanced-fixed- displacement type vane pump combined with an induction type electric motor was suggested. By the application of the new design scheme, it was possible to reduce the number of parts of the pump system and to cut down the volume of power package than that of already-used products. The case in this study enabled efficient heat transfer and electricity insulation of hydraulic fluid. Thus oil moves through the inside of the package for cooling and returns to the reservoir. Because of this design, it was difficult to measure the shaft-input torque. Therefore the package overall efficiency in the paper was evaluated with a ratio of hydraulic power and electric power.

  • PDF

Case study on Remodeling Clearwell Hydraulic Structure using Transient CFD Simulation Technique (Transient CFD 모사기법을 이용한 정수지 최적설계 사례연구)

  • Kim, Seon-Jin;Kim, Seong-Su;Park, No-Suk;Cha, Min-Whan;Wang, Chang-Keun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.4
    • /
    • pp.425-432
    • /
    • 2010
  • From the results of tracer test for the existing clearwell in Y water treatment plant, $T_{10}$ and T10/T were calculated as 150 min and 0.24, respectively. Therefore it required the modification schemes for improving hydraulic efficiency, surrogated by $T_{10}$ and $T_{10}$/T, and disinfection performance. In this study, using transient CFD(Computational Fluid Dynamics) simulation technique, tracer tests on dynamic condition for the suggested schemes were simulated. From the results of simulation, it was revealed that 8~6 baffles are necessary to guarantee the disinfection ability in the existing clearwell. Also, installing orifice baffle in the vicinity of inlet could increase plug flow fraction within clearwell.

Around View Monitoring System for Hydraulic Excavators

  • Yeom, Dong Jun;Hong, Yu Na;Kim, Yoo Jun;Yoo, Hyun Seok;Kim, Young Suk
    • International conference on construction engineering and project management
    • /
    • 2017.10a
    • /
    • pp.124-132
    • /
    • 2017
  • This paper describes the Around View Monitoring (AVM) system for hydraulic excavators that prevents the safety accidents caused by blind spots and increases the operational efficiency. To verify the developed system, experiments were conducted with its prototype. The experimental results demonstrate its applicability in the field with the following values: 7m of a visual range, 15fps of image refresh rate, 300ms of working information data reception rate, and 300ms of surface condition data reception rate.

  • PDF

Comparison of Anaerobic Digestion Efficiency with Different Temperature of Food Wastes (음식물류폐기물의 성상별 온도변화에 따른 혐기성소화 효율 비교 연구)

  • Hwang, Kwanghyun;Kim, Dongik
    • Journal of Korean Society on Water Environment
    • /
    • v.35 no.4
    • /
    • pp.332-339
    • /
    • 2019
  • A comparative study on the anaerobic digestion efficiency according to the temperature change was conducted considering the characteristics of domestic food wastes with high water content of about 80 % or more. The substrate was tested for anaerobic digestion efficiency in two substrates, a liquid component separated naturally from food waste and food waste itself. In the anaerobic digestion experiments, the digestion efficiency was the highest at $55^{\circ}C$ (thermophilic temperature). However, the digestion efficiency at $45^{\circ}C$(middle high temperature) was lower than that at $35^{\circ}C$(mesophilic temperature). The comparison of general food wastes anaerobic digestion requiring 30 days of hydraulic retention time to the liquid component indicated a stable digestion efficiency even after 15 days of hydraulic retention time.In the experiments conducted on food waste, the digestion efficiency at $55^{\circ}C$ was higher than that at $35^{\circ}C$. When the food waste, especially the liquid component originating from food waste, is treated by anaerobic digestion method, the mesophilic temperature and thermophilic temperature conditions are more favorable in the digestion efficiency than the middle high temperature ($45^{\circ}C$). However, when applying thermophilic or mesophilic temperature anaerobic digestion process operation in the field, the amount of energy input should be considered.

The Optimal Design and Performance Test of Plunger Pump (플런저 펌프 설계 및 성능시험)

  • 김동수;서현석
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.840-843
    • /
    • 2003
  • The Paper presents theoretical and experimental investigation of plunger type water hydraulic pump (plunger pump). An analysis of Crank shaft for plunger pump is carried out. With this results, the optimal dimensions of plunger pump are determined. And performance test results about slide resistance, hydraulic leak test, efficiency-pressure. and flow-speed and flow-pressure are presented.

  • PDF

Effects of Oxygen Transfer Rate of a Polystyrene Foam Bead Media in a Packed Column Aerator (Packed Column 에어레이터에서 매질로 이용한 발포스티로폼 입자의 산소 전달 효과)

  • 박정환;김유희;조재윤
    • Journal of Aquaculture
    • /
    • v.13 no.3
    • /
    • pp.267-275
    • /
    • 2000
  • To evaluate the characteristics and efficiency of oxygen transfer rate of a polystyrene foam bead as media in a packed column aerator was tested. This media has more surface area and cheaper than other ordinary plastic media. The polystyrene foam media was a sphere-shaped bead with 2.5 mm in diameter and specific surface area was 1,350 $m^2$/$m^3$. Oxygen transfer rate and standard aeration efficiency were tested under different hydraulic loading rates, depths of the media and temperatures. Experiment 1 was performed using a small packed column aerator with 10 cm in diameter and 1 m in length. The aerator filled with 0, 4.5, 9.0 and 18.0 cm of the media was tested under hydraulic loading rates of 2.0, 4.0 and 5.6 $m^3$/$m^2$/min at temperatures of 20, 25 and 3$0^{\circ}C$, respectively. In this experiment, standard oxygen transfer rate (SOTR) increased with the hydraulic loading rate and depth of the media increased. The maximum SOTR was reached at 5.6 $m^3$/$m^2$/min of hydraulic loading rate with 9 cm in depth of the media. However, standard aeration efficiency (SAE) decreased with the hydraulic loading rate increased because electricity consumed by pump increased as hydraulic loading rate increased. The highest SAE was reached at hydraulic loading rate of 2.0 $m^3$/$m^2$/min with 9.0 cm in depth of the media. Therefore, the highest SOTR and SAE were achieved at 9.0 cm in depth of the media regardless of the hydraulic loading rate. The maximum SAE was about 1.8 kg $O_2$/kW-hr with the hydraulic loading .ate of $m^3$/$m^2$/min at temperature of 20 $^{\circ}C$.Experiment 2 was performed using a larger aerator, 20 cm in diameter with 2 m in height. The aerator filled with 0, 9, 18, 27 and 36 cm of the media was operated under hydraulic loading rate of 2.0, 4.0 and 5.6 $m^3$/$m^2$/min at temperature of 27 $^{\circ}C$. The SAE reached to the highest efficiency (1.9 kg $O_2$/kW-hr) at 2.0 $m^3$/$m^2$/min of hydraulic loading rate and 36 cm in depth of the media. According to the above results, the polystyrene foam bead as a media in a packed column aerator was effective to increase oxygen transfer rate.

  • PDF