• Title/Summary/Keyword: hybrid semi-active control

Search Result 38, Processing Time 0.023 seconds

Hybrid Control of Aircraft Landing Gear using Magnetorheological Damper (MR댐퍼를 적용한 항공기 착륙장치의 하이브리드 제어기법 연구)

  • Tak, Jun Mo;Viet, Luong Quoc;Hwang, Jai-Hyuk
    • Journal of Aerospace System Engineering
    • /
    • v.12 no.1
    • /
    • pp.1-9
    • /
    • 2018
  • In this study, a hybrid control method that adjusts for the existing force control technique has been presented for consideration. The proposed hybrid control technique does away with the chattering phenomenon occurring in existing force control technique and provides high shock absorption efficiency. In order to design the controller for the landing gear with MR damper, the equation of motion of the landing gear was derived. The hybrid controller was designed after constructing a simulation model using Recur-Dyne, multi-body dynamic analysis software. The hybrid controller can reduce the maximum strut force and displacement based on the skyhook controller, and is able to get the high efficiency by making it work for the additional force control technique. In addition, an effective switching control technique and input shaping technique was applied to prevent the chattering in the drop simulation. Finally, the performance of the landing characteristics was evaluated throughout the various drop simulations.

Domestic Efforts for SFCL Application and Hybrid SFCL (국내 초전도 한류기 요구와 하이브리드 초전도 한류기)

  • Hyun, O.B.;Kim, H.R.;Yim, Y.S.;Sim, J.;Park, K.B.;Oh, I.S.
    • Progress in Superconductivity
    • /
    • v.10 no.1
    • /
    • pp.60-67
    • /
    • 2008
  • We present domestic efforts for superconducting fault current limiter (SFCL) application in the Korea Electric Power Corporation (KEPCO) grid and pending points at issue. KEPCO's decision to upgrade the 154 kV/22.9 kV main transformer from 60 MVA to 100 MVA cast a problem of high fault current in the 22.9 kV distribution lines. The grid planners supported adopting an SFCL to control the fault current. This environment friendly to SFCL application must be highly dependent upon the successful development of SFCL having specifications that domestic utility required. The required conditions are (1) small size of not greater than twice of 22.9 kV gas insulated switch-gear (GIS), (2) sustainability of current limitation without the line breaking by circuit breakers (CB) for maximum 1.5 seconds. Also, optionally, recommended is (3) the reclosing capability. Conventional resistive SFCLs do not meet (1) $\sim$ (3) all together. A hybrid SFCL is an excellent solution to meet the conditions. The hybrid SFCL consists of HTS SFCL components for fault detection and line commutation, a fast switch (FS) to break the primary path, and a limiter. This characteristic structure not only enables excellent current limiting performances and the reclosing capability, but also allows drastic reduction of HTS volume and small size of the cryostat, resulting in economic feasibility and compactness of the equipment. External current limiter also enables long term limitation since it is far less sensitive to heat generation than HTS. Semi-active operation is another advantage of the hybrid structure. We will discuss more pending points at issues such as maintenance-free long term operation, small size to accommodate the in-house substation, passive and active control, back-up plans, diagnosis, and so on.

  • PDF

Development and Evaluation of a Hybrid Damper for Semi-active Suspension (반능동 현가장치의 하이브리드형 댐퍼 개발에 관한 연구)

  • Jin, Chul Ho;Yoon, Young Won;Lee, Jae Hak
    • Journal of Drive and Control
    • /
    • v.15 no.1
    • /
    • pp.38-49
    • /
    • 2018
  • This research describes the development model and testing of a hybrid damper which can be applicable to a vehicle suspension. The hybrid damper is devised to improve the performance of a conventional passive oil damper using a magneto-rheological (MR) accumulator which consists of a gas accumulator and a MR device. The level of damping is continuously variable by the means of control in the applied current in a MR device fitted to a floating piston which separates the gas and the oil chamber. A simple MR device is used to resist the movement of floating piston. At first a mathematical model which describes all flows within the conventional oil damper is formulated, and then a small MR device is also devised and adopted to a mathematical model to characterize the performance of the device.

Fuzzy Controller Design for a Automotive Air Suspension (자동차 에어 서스펜션에 대한 퍼지 제어기 설계)

  • Liu, H.;Lee, J.C.
    • Journal of Drive and Control
    • /
    • v.9 no.2
    • /
    • pp.1-7
    • /
    • 2012
  • 본 연구의 목적은 에어 서스펜션 시스템의 제어 특성을 분석하는 것이다. 우선 에어 서스펜션 시스템의 수학적 모델을 구하였다. 그리고 퍼지 제어 알고리즘을 적용하여 반능동식 하이브리드 제어 에어 서스펜션을 구하였다. 차체 가속도에 따라 퍼지 제어기는 오리피스 개도를 변경하여 특정 영역에서 에어 스프링의 강도를 조정한다. 동시에 서스펜션 운동 상태에 따라 서스펜션 댐핑이 제어된다. 시뮬레이션 결과는 반능동식 하이브리드 제어 에어 서스펜션이 노면 접지능력의 상실이나 서스펜션 작동 공간의 증가 없이 최고의 승차감을 제공할 수 있음을 보여준다.

Bridges dynamic analysis under earthquakes using a smart algorithm

  • Chen, Z.Y.;Meng, Yahui;Wang, Ruei-yuan;Chen, Timothy
    • Earthquakes and Structures
    • /
    • v.23 no.4
    • /
    • pp.329-338
    • /
    • 2022
  • This work addresses the optimization controller design problem combining the AI evolution bat (EB) optimization algorithm with a fuzzy controller in the practical application of a reinforced concrete frame structure. This article explores the use of an intelligent EB strategy to reduce the dynamic response of Lead Rubber Bearing (LRB) composite reinforced concrete frame structures. Recently developed control units for plant structures, such as hybrid systems and semi-active systems, have inherently non-linear properties. Therefore, it is necessary to develop non-linear control methods. Based on the relaxation method, the nonlinear structural system can be stabilized by properly adjusting the parameters. Therefore, the behavior of a closed-loop system can be accurately predicted by determining the behavior of a closed-loop system. The performance and durability of the proposed control method are demonstrated by numerical simulations. The simulation results show that the proposed method is a viable and feasible control strategy for seismically tuned composite reinforced concrete frame structures.

Control of wind-induced motion in high-rise buildings with hybrid TM/MR dampers

  • Aly, Aly Mousaad
    • Wind and Structures
    • /
    • v.21 no.5
    • /
    • pp.565-595
    • /
    • 2015
  • In recent years, high-rise buildings received a renewed interest as a means by which technical and economic advantages can be achieved, especially in areas of high population density. Taller and taller buildings are being built worldwide. These types of buildings present an asset and typically are built not to fail under wind loadings. The increase in a building's height results in increased flexibility, which can lead to significant vibrations, especially at top floors. Such oscillations can magnify the overall loads and can be annoying to the top floors' occupants. This paper shows that increased stiffness in high-rise buildings may not be a feasible solution and may not be used for the design for comfort and serviceability. High-rise buildings are unique, and a vibration control system for a certain building may not be suitable for another. Even for the same building, its behavior in the two lateral directions can be different. For this reason, the current study addresses the application of hybrid tuned mass and magneto-rheological (TM/MR) dampers that can work for such types of buildings. The proposed control scheme shows its effectiveness in reducing floors' accelerations for both comfort and serviceability concerns. Also, a dissipative analysis carried out shows that the MR dampers are working within the possible range of optimum performance. In addition, the design loads are dramatically reduced, creating more resilient and sustainable buildings. The purpose of this paper is to stimulate, shape, and communicate ideas for emerging control technologies that are essential for solving wind related problems in high-rise buildings, with the objective to build the more resilient and sustainable infrastructure and to optimally retrofit existing structures.

Fuzzy Hybrid Control of Semi-active TMD (준능동 TMD의 퍼지 하이브리드 제어)

  • Kim, Hyun-Su;Lee, Dong-Guen
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2009.04a
    • /
    • pp.433-436
    • /
    • 2009
  • 본 연구에서는 준능동 TMD(STMD)가 설치된 초고층건물의 풍응답을 효과적으로 저감시키기 위한 퍼지 하이브리드제어기법을 제안하였다. 이를 위하여 STMD의 응답저감에 우수한 성능을 보이는 스카이훅(skyhook) 제어기와 구조물의 응답저감에 뛰어난 그라운드훅(groundhook) 제어알고리즘을 사용하였다. 본 연구에서는 두 제어기를 적절히 조합하기 위하여 최적의 가중치를 실시간으로 결정하는 퍼지 하이브리드제어기를 개발함으로써 일반적인 가중합방식의 하이브리드 제어기법의 성능을 개선하였다. 제안된 제어기의 성능을 검토하기 위하여 풍하중을 받는 76층 사무소 건물을 예제구조물로 사용하였다. MR 감쇠기를 이용하여 STMD를 구성하였고 STMD의 제어성능을 평가하기 위하여 TMD 및 ATMD의 성능과 비교하였다. 수치해석을 통하여 STMD의 제어성능이 TMD에 비하여 월등히 뛰어남을 확인할 수 있었다. 또한 퍼지 하이브리드 제어기법을 사용하면 스카이훅 및 그라운드훅 제어기를 효과적으로 조합하여 STMD와 건물의 응답을 동시에 줄일 수 있음을 확인하였다.

  • PDF

Effect of soil in controlling the seismic response of three-dimensional PBPD high-rise concrete structures

  • Mortezaie, Hamid;Rezaie, Freydoon
    • Structural Engineering and Mechanics
    • /
    • v.66 no.2
    • /
    • pp.217-227
    • /
    • 2018
  • In the last decades, valuable results have been reported regarding conventional passive, active, semi-active, and hybrid structural control systems on two-dimensional and a few three-dimensional shear buildings. In this research, using a three-dimensional finite element model of high-rise concrete structures, designed by performance based plastic design method, it was attempted to construct a relatively close to reality model of concrete structures equipped with Tuned Mass Damper (TMD) by considering the effect of soil-structure interaction (SSI), torsion effect, hysteresis behavior and cracking effect of concrete. In contrast to previous studies which have focused mainly on linearly designed structures, in this study, using performance-based plastic design (PBPD) design approach, nonlinear behavior of the structures was considered from the beginning of the design stage. Inelastic time history analysis on a detailed model of twenty-story concrete structure was performed under a far-field ground motion record set. The seismic responses of the structure by considering SSI effect are studied by eight main objective functions that are related to the performance of the structure, containing: lateral displacement, acceleration, inter-story drift, plastic energy dissipation, shear force, number of plastic hinges, local plastic energy and rotation of plastic hinges. The tuning problem of TMD based on tuned mass spectra is set by considering five of the eight previously described functions. Results reveal that the structural damage distribution range is retracted and inter-story drift distribution in height of the structure is more uniform. It is strongly suggested to consider the effect of SSI in structural design and analysis.