• Title/Summary/Keyword: hourly variation

Search Result 139, Processing Time 0.023 seconds

Spatial Gap-Filling of Hourly AOD Data from Himawari-8 Satellite Using DCT (Discrete Cosine Transform) and FMM (Fast Marching Method)

  • Youn, Youjeong;Kim, Seoyeon;Jeong, Yemin;Cho, Subin;Kang, Jonggu;Kim, Geunah;Lee, Yangwon
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.4
    • /
    • pp.777-788
    • /
    • 2021
  • Since aerosol has a relatively short duration and significant spatial variation, satellite observations become more important for the spatially and temporally continuous quantification of aerosol. However, optical remote sensing has the disadvantage that it cannot detect AOD (Aerosol Optical Depth) for the regions covered by clouds or the regions with extremely high concentrations. Such missing values can increase the data uncertainty in the analyses of the Earth's environment. This paper presents a spatial gap-filling framework using a univariate statistical method such as DCT-PLS (Discrete Cosine Transform-based Penalized Least Square Regression) and FMM (Fast Matching Method) inpainting. We conducted a feasibility test for the hourly AOD product from AHI (Advanced Himawari Imager) between January 1 and December 31, 2019, and compared the accuracy statistics of the two spatial gap-filling methods. When the null-pixel area is not very large (null-pixel ratio < 0.6), the validation statistics of DCT-PLS and FMM techniques showed high accuracy of CC=0.988 (MAE=0.020) and CC=0.980 (MAE=0.028), respectively. Together with the AI-based gap-filling method using extra explanatory variables, the DCT-PLS and FMM techniques can be tested for the low-resolution images from the AMI (Advanced Meteorological Imager) of GK2A (Geostationary Korea Multi-purpose Satellite 2A), GEMS (Geostationary Environment Monitoring Spectrometer) and GOCI2 (Geostationary Ocean Color Imager) of GK2B (Geostationary Korea Multi-purpose Satellite 2B) and the high-resolution images from the CAS500 (Compact Advanced Satellite) series soon.

Characteristics of Surface High Ozone Concentration on Pusan Coastal area, Korea (부산 해안지역의 고농도 오존 발생 특성에 관한 연구)

  • 전병일
    • Journal of Environmental Science International
    • /
    • v.9 no.4
    • /
    • pp.295-302
    • /
    • 2000
  • This study was conducted to investigate the characteristics of surface ozone concentration and occurrence of high ozone concentration using hourly ozone, nitrogen dioxide and meteorological data for 1997~1998 in Pusan coastal area. Monthly mean ozone concentration was the highest at Dongsamdong in Spring(35.4ppb), at Kwangbokdong in Fall(25.1ppb) and the lowest Dongsamdong(22.2ppb) and Kwangbokdong(16.0ppb) in Winter. Relative standard deviation indicating clearness of observation site was 0.42 at Dongsamdong and 0.49 at Kwangbokdong that is similar to urban area. The diurnal variation of ozone concentration of Dongsamdong and Kwangbokdong showed maximum at 1500~1600LST and minimum 0700~0800LST that typical pattern of ozone concentration. In ozone episode period(Sept. 10~15, 1998), diurnal change of ozone concentration was very high, and ozone concentration was related to meteorological parameters such as temperature, relative humidity, wind speed, cloud amount and radiation on a horizontal surface. During the episode days peak ozone concentrations are much higher than the normal values, wind speeds are always lower, and solar radiation is high with the exception of the September episode.

  • PDF

A Study on the Characteristics of Surface Ozone Concentration at Dongsamdong, Pusan (부산 동삼동 지역의 지표오존농도 특성 연구)

  • Jeon, Byung Il
    • Journal of Environmental Impact Assessment
    • /
    • v.8 no.2
    • /
    • pp.21-29
    • /
    • 1999
  • This study was conducted to investigate the characteristics of surface ozone concentration and occurrence of high ozone concentration using hourly ozone and meteorological data of 1997~1998 in Pusan coastal area. Monthly mean ozone concentration was highest in Spring(35.4ppb) and lowest in Winter(22.2ppb). Relative standard deviation indicating clearness of observation site was 0.42 that is similar to urban area. The diurnal variation of ozone concentration of Dongsamdong showed maximum at 15~16LST and minimum 07~08LST that typical pattern of ozone concentration. In ozone episode period(May 18~23, 1998), diurnal change of ozone concentration was very high, and ozone concentration was related to meteorological parameters such as temperature, relative humidity, wind speed, cloud amount and radiation on a horizontal surface.

  • PDF

Model Development of Daily and Hourly Energy Load for Department Stores (백화점 건물의 에너지 부하모델 개발)

  • 박화춘;이승수;김대진
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.12
    • /
    • pp.1088-1094
    • /
    • 2003
  • Case study was peformed to analyze energy load for department stores and develop energy load model to be applied to a cogeneration system. Energy loads of 14 departments were analyzed based on energy load sheets written by operators and energy load of one department store was measured through modem communication for a year. Energy load of department stores shows various variations depending on when they are opened or closed and, hours, days and months. In this paper, the measurement was compared with data in energy load sheets and resolved, and energy load model for a department store was built. It is important to use an accurate energy load model for an accurate feasibility study applying a cogeneration system to buildings.

Characteristics of nocturnal maximum ozone and meteorological relevance in Pusan coastal area (부산 연안역의 야간 고농도 오존 발생 특성과 기상학적 관련성)

  • 전병일
    • Journal of Environmental Science International
    • /
    • v.8 no.3
    • /
    • pp.287-292
    • /
    • 1999
  • This study was performed to investigate the characteristics of nocturnal maxiumu ozone occurrence and the meteorological relevance using to hourly ozone data and meteorological data for 1995~1996 in Pusan coastal area. Kwangbokdong showed the highest occurrence of nocturnal maximum ozone as 36.9%, and Deokcheondong showed the lowest occurrence(9.2%) for research period in Pusan. The occurrence rates of nocturnal maximum ozone concentration were decreased toward land area. The low maximum temperature, high minimum temperature, low diurnal range, high relative humidity, high wind speed, high could amount, low sunshine and low radiation were closely related to the main meteorological characteristics occuring the nocturnal maximum concnetration of ozone. It was shown that normal daily variation of ozone concentration by strong photochemical reaction at the before day of nocturnal maximum ozone. The concnetration of nocturnal maximum ozone were occured by entrainment of ozone from the upper layer of developed mixing layer. There are no ozone sources near the ground at night, so that the nighttime ozone should be entrained from the upper layer by forced convection.

  • PDF

A Numerical Simulation of High Ozone Episode Using OZIPR in Busan (OZIPR을 이용한 부산지역 고농도 오존 사례 모사)

  • Do, Woo-Gon;Lee, Hwa-Woon;Jung, Woo-Sik
    • Journal of Environmental Science International
    • /
    • v.16 no.8
    • /
    • pp.985-994
    • /
    • 2007
  • To investigate the effect of NOx and VOCs(volatile organic compounds) on the generation of high ozone episode, examined the hourly variations of ozone, NOx and VOCs concentrations, and calculated the ozone isopleth about maximum ozone concentrations using OZIPR which was presented by U. S. EPA at three sites in Busan. There was some difference by the sites, but decreasing VOCs concentration was effective for reduction of ozone at 22 July, the episode day of 2005. In the year 2006, the episode day was 8 August and the variations of NOx and VOCs concentration was little than variation of ozone. So it was estimated that the photochemical production of ozone was low than transportation of ozone. And the result of the OZIPR modeling was that decreasing VOCs concentration was effective for reduction of ozone.

Model Development of Daily and Hourly Energy Load for Department Stores

  • Park Hwa-Choon;Lee Sung-Soo;Kim Dae-Jin
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.12 no.4
    • /
    • pp.169-175
    • /
    • 2004
  • Case study was performed to analyze energy load for department stores and develop energy load model to be applied to a cogeneration system. Energy loads of 14 depart­ments were analyzed based on energy load sheets written by operators and energy load of one department store was measured through modem communication for a year. Energy load of department stores showed various trends depending on when they were opened or closed, or by hour, day and month. In this paper, the measurement was compared with the data in energy load sheets and resolved, and energy load model for a department store was built. It is important to use an accurate energy load model for an accurate feasibility study applying a cogeneration system to buildings.

Diurnal Variation of the Surface Wind in the Coastal Boundary Layer (沿岸境界層에서의 表層風의 日變化)

  • Choi, Hyo
    • 한국해양학회지
    • /
    • v.19 no.2
    • /
    • pp.210-216
    • /
    • 1984
  • Diurnal variations of coastal surface wind speed are analyzed with five years of hourly wind from Port Aransas, Texas. These data reveal the highest frequency of occurrence of the nighttime wind maximum near midnight, especially during those seasons when onshore flow prevails. Nighttime wind maxima with a southerly component occurred approximately three times more frequently than with a northerly component on the annual average. The neutral atmospheric stability prevails near the coast. Thus it allows downward transfer of momentum from the nocturnal low level jet under the onshore wind situation and strong wind shear between an elevated frontal and ground-based inversion for offshore wind, resulting in the nocturnal coastal surface wind maximum.

  • PDF

Simultaneous N-P Removal of Wastewater with Flow Variation by Anaerobic-Aerobic Activated Sludge Process(I) (혐기-호기 활성슬러지법에 의한 유량변동이 있는 폐수의 N-P 동시 제거에 관한 연구(I))

  • 이민규;서근학
    • Journal of Environmental Science International
    • /
    • v.4 no.5
    • /
    • pp.509-516
    • /
    • 1995
  • The treatment performances of anaerobic-aerobic activated sludge process were investigated under various operation conditions. The treatment system proposed in this study gave a relatively stable performance against hourly change of the flow rate and showed a satisfactory removal of nitrogen and phosphorus compounds under experimental conditions. The recycle ratio of mixed liquor from aerobic to anaerobic region and peak coefficient primarily controlled the extent of nitrogen removal. The recycle ratio had the optimum values which were determined by the microbial activities of nitrification and denitrification. The behavior of the treatment unit could be simulated by using the kinetic equations and reactor models which considered the treatment units as complete mixing tanks.

  • PDF

Simultaneous N-P Removal of Wastewater with Flow Variation by Anaerobic-Aerobic Activated Sludge Process(I) (혐기-호기 활성슬러지법에 의한 유량변동이 있는 폐수의 N-P 동시 제거에 관한 연구(I))

  • Lee, Min-Gyu;Suh, Kuen-Hack
    • Journal of Environmental Science International
    • /
    • v.4 no.5
    • /
    • pp.123-123
    • /
    • 1995
  • The treatment performances of anaerobic-aerobic activated sludge process were investigated under various operation conditions. The treatment system proposed in this study gave a relatively stable performance against hourly change of the flow rate and showed a satisfactory removal of nitrogen and phosphorus compounds under experimental conditions. The recycle ratio of mixed liquor from aerobic to anaerobic region and peak coefficient primarily controlled the extent of nitrogen removal. The recycle ratio had the optimum values which were determined by the microbial activities of nitrification and denitrification. The behavior of the treatment unit could be simulated by using the kinetic equations and reactor models which considered the treatment units as complete mixing tanks.