• Title/Summary/Keyword: hour-line

Search Result 257, Processing Time 0.029 seconds

Assessment of Short-Time Characteristic ACSR-OC Conductor (ACSR-OC 전선의 단시간 특성 평가)

  • Lee, Joong-Kwan;Kim, Dong-Muyng;Yi, Sue-Muk
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1446-1448
    • /
    • 2002
  • The short-time permissible temperature of an overhead distribution line conductor is determined by the softening characteristics of ACSR-OC, ACSR AW/OC 160, typical conductors employed in the overhead distribution line. Transient heat transfer equation and Newton's cooling law were applied to analyze the heating and cooling effects of the insulating conductors, respectively, and the error of co-relation was calibrated after simulating the softening test to assess the short-time characteristic of the insulating conductor. In order to verify the softening characteristic, the conductors were tested with heat cycle. The test was totally carried out 200 cycles, and 1 cycle was to heat and cool at 1.1 times permissible current of the conductor, 1.15 times for 120 minutes, respectively. After heating, the tensile strength and surface of the conductor were observed. In case of ACSR-OC, as the result of 100 hour heating test, the tensile strength of the insulator was 0.8 times the initial value. This is equivalent to the value of the conductors which are used for 10 years at sites.

  • PDF

A Study on the Congestion Alleviation Method and the Enhancement of the Transport Capacity in the SeoulMetro No.2 Outer Circle line (서울메트로 2호선 외순환 구간의 혼잡완화 및 수송력 증대 방안에 관한 연구)

  • Lee, Hyun-Ju;Kook, Kwang-Ho;Son, Young-Jin
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.1416-1425
    • /
    • 2008
  • Urban railway carries large numbers of passengers during the rush hour. According to the announcement of Ministry of Land Transport and Maritime Affairs(MLTM), 221% of the congestion rate is reported in the SeoulMetro No.2 outer circle line from sadang to bangbea between eight and nine o'clock in the morning. This study analyzes the cause of the client's dissatisfaction about SeoulMetro such as the train delay, and decides the preference rank of the alternatives for congestion alleviation and enhancement of the transport capacity using Analytic Hierarchy Process(AHP).

  • PDF

Power System Simulation in Seoul matropolitain subway Line-6 system (서울 지하철 6호선에 대한 전력계통 시뮬레이션)

  • Lee, Tae-Shik;Moon, Young-Hyun;Sung, Soo-Young;Yoon, Kap-Koo
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.137-139
    • /
    • 1993
  • This paper details methods used to verify the adquacy of a dc traction power supply for design in Seoul matropolitain subway Line-6 system. Examples of the approach are given for a major subway presently under construction. The performance of trains operating at maximum system design capacity is modelled using a train simulation program. Using a dc network analyser program, the maximum train operating timetable, and a model of the ac and dc electrical suppy system, the electrical performance of the entire system can be modelled over a 24-hour period. The results of this analysis are used to determime: train voltage at a level sufficient to ensure train schedules: adequacy of traction transformers, rectifier, and switchgear ratings; sizes of the overhead contact systern conductors, and ac and de feeder cables: and power and energy demands at the utility company's supply points for inital and final timetable operations.

  • PDF

Design Flow Velocity Changes According to the Design Flow Determination Methods in the Sanitary Sewer (오수관 설계유량 산정법이 설계유속에 미치는 영향)

  • Hyun, In-hwan;Won, Seung-hyun;Kim, Hyung-jun;Lee, Che-in
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.6
    • /
    • pp.749-757
    • /
    • 2005
  • The present study analyzed actual cases of designed flow estimation method and designed flow rate of sewage pipe lines. In order to examine the effects of peak-hour demand factor estimation with given daily highest peak loading, we analyzed its effects on designed flow rate with changing the peak-hour demand factor from 2.0 to 10.0. The results of this study are as follows. When reviewing the recent designs, we found that 59.4% of pipe line with 250mm and 300mm diameter, which fall under minimum allowable pipeline did not meet the minimum velocity which is specified as 0.6m/sec in design standards. The pipe line that have minimal access population or have very low slope did not satisfy the minimum velocity. In estimating the designed sewage flow, the applied daily highest peak loading and hourly highest peaking loading were the load factor for the entire population of the planned area, and for the peak loading of the initial pipes connected to a very small population, we applied the same factor as that applied to the entire area and, as a result, the hourly highest flow was underestimated. Because, in case of the initial pipes, the method of applying the same peak loading to all subject areas is highly possible to produce underestimated design flow, when estimating the designed flow of the initial pipes connected to a small population need to adopt a rational flow factor according to the size of population. For this, it is considered to investigate and analyze raw data on daily and hourly variation of sewage flow.

A Prediction of $CO_2$ Concentration and Measurement of Indoor Air Quality in the EMU (전동차 실내공기질 측정 및 $CO_2$ 농도 예측)

  • So, Jin-Sub;Yoo, Seong-Yeon
    • Journal of the Korean Society for Railway
    • /
    • v.11 no.4
    • /
    • pp.378-383
    • /
    • 2008
  • In December 2006, the Ministry of Environment Republic of Korea established the guideline which is "Indoor Air Quality Management Guidelines in Public Transportation." as control items, $CO_2$ (carbon dioxide) and PM10 (particle matter) are classified two categories, that is, Level 1 (non-rush hour), Level 2 (rush hour). Therefore, the quality of air in train and subway should be controlled in accordance with the guideline. We took a measure the air freshness inside train twice at Line 4 (Tangogae-Oido), in Sep. 2007 and at Line 1 (Dongincheon-Yongsan) in Nov. 2007, respectively and, also expected the emitted $CO_2$ concentration by using a property of matter such as EMU (Electric Multiple Unit) design reviewing specification and air. According to the measured values, the concentration of PM10 was 44, 57, 45% and the concentration of $CO_2$ was 39, 36, 44% respectively, all measured values are within the guideline and also, as a result we found the expected value and measured value are similar.

Experimental Study on the Radiosensitivity and Chemosensitivity of A-431 Cell Line (A-431 세포주의 방사선 및 항암제의 감수성에 관한 실험적 연구)

  • Hong Seong-Woo;Choi Eun-Suk;Koh Kwang-Joon
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.1
    • /
    • pp.327-339
    • /
    • 1999
  • Objectives: The purpose of this study was to aid in the prediction of tumor cell tolerance to radiotherapy and/or chemotherapy. Material and Methods: Human epidermoid carcinoma A-431 cell lines were irradiated by 2, 4, 6, 8, 10Gy at a dose rate of 210cGy/min using /sup 60/Co Irradiator ALDORADO 8 and then were exposed to bleomycin or cisplatin at concentration of 2㎍/㎖ for 1 hour. The viable cells were determined for each radiation dose and/or each drug at the 4th day and cell surviving curves were obtained using semiautomated MTT assay. Results: The surviving fraction after irradiation of 2Gy was 0.99, and there was not significant difference of surviving fraction in comparison with the control group on A-431 cell line(P>0.05). But there were significant differences of surviving fractions at doses of 4, 6, 8, 10Gy in comparison with the control group(P<0.05). The cytotoxicity of bleomycin or cisplatin was significantly different in comparison with the control group on A-43l cell line (P<0.05). And the cytotoxicity of cisplatin was greater than that of bleomycin on A-431 cell line (P<0.05). There were significant differences of surviving fractions after irradiation of 2, 4, 6, 8, 10Gy with bleomycin or cisplatin in comparison with each group of irradiation only on A-431 cellline(P<0.05). There were significant differences of surviving fractions between the groups of irradiation with bleomycin and cisplatin at doses of 2, 4Gy(P<0.05), but there were not significant differences of surviving fractions at doses of 6, 8, 10Gy on A-431 cell line (P>0.05).

  • PDF

AN EXPERIMENTAL STUDY ON THE RADIOSENSITIVITY AND CHEMOSENSITIVITY OF MG-63 CELL LINE (MG-63 세포주의 방사선 및 항암제감수성에 관한 실험적 연구)

  • Lee Un-Gyeong;Koh Kwang-Joon
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.26 no.2
    • /
    • pp.121-132
    • /
    • 1996
  • The purpose of this study was to aid in the prediction of tumor cell tolerance to radiotherapy and/or chemotherapy. For this study, cell surviving curves were obtained for human osteosarcoma MG-63 cell line using semiautomated MTT assay. 2,4, 6, 8, 10Gy were irradiated at a dose rate of 210cGy/min using /sup 60/Co Irradiator ALDORADO 8. After irradiation, MG-63 cell lines(3×10⁴ cells/ml) were exposed to bleomycin and cisplatin at concentration of 0.2, 2, 20㎍/㎖ for 1 hour respectively. The viable cells were determined for each radiation dose and/or each concentration of drug. And they were compared to control values. The obtained results were as follows : 1. There was significant difference of surviving fraction at 4, 6, 8, 10Gy on MG-63 cell line(p<0.05). 2. There was significant difference of cytotoxicity of bleomycin or cisplatin at all concentration of 0.2, 2, 20㎍/㎖ (p<0.05) on MG-63 cell line. The cytotoxicity of cisplatin was more effective than bleomycin at concentration of 20㎍/㎖ on MG-63 cell line. 3. There was significant difference of cytotoxicity of bleomycin or cisplatin at all concentration after irradiation of 2Gy on MG-63 cell line. 4. There was significant difference of cytotoxicity of bloemycin or cisplatin at concentration of 20㎍/㎖ after irradiation than that of irradiation alone(p<0.01). But there was no significant difference of cytotoxicity of bleomycin at concentration of 20㎍/㎖ after irradiation of l0Gy than that of irradiation alone.

  • PDF

A STUDY ON THE RADIOSENSITIVITY AND CHEMOSENSITIVITY OF KB CELL LINE IN VITRO (시험관내 KB세포주의 방사선 및 항암제감수성에 관한 연구)

  • Hong Sung-Woo;Choi Eun-Suk;Koh Kwang-Joon
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.28 no.1
    • /
    • pp.271-283
    • /
    • 1998
  • The purpose of this study was to aid in the prediction of tumor cell tolerance to radiotherapy and/or chemotherapy. For this study, cell surviving curves were obtained for human squamous cell carcinoma KB cell line after radiation exposure and/or administration of antitumor drugs. 2, 4, 6, 8, 10Gy were irradiated at a dose rate of 210cGy/min using /sup 60/Co Irradiator ALDORADO 8. After irradiation, KB cell lines (3×104cells/ml) were exposed to 2㎍/ml of bleomycin or cisplatin for 1 hour. The viable cells were determined by MTT assay for each radiation dose and/or each drug at the 4th day. And they were compared to control values. The obtained results were as follows : 1. The slope of the surviving curve after irradiation of 2, 4, 6, 8, 10Gy on KB cell line was relatively steep. 2. There was no significant difference between the cytotoxicity of bleomycin compared to control group. But, there was significant difference between the cytotoxicity of cisplatin compared to control group. And the cytotoxicity of cisplatin was greater than that of bleomycin on KB cell line. 3. There were significant differences of surviving fractions after irradiation of 2Gy and 10Gy with 2㎍/ml of bleomycin compared with the groups of irradiation only on KB cell line. 4. There were significant differences of surviving fractions after irradiation of 2, 4, 6, 8, 10Gy with 2㎍/ml of cisplatin compared with the groups of irradiation only on KB cell line. 5. There was significant difference of surviving fraction between groups after irradiation of 10Gy with 2㎍/ml of bleomycin and cisplatin.

  • PDF

Automobile Assembly Sequence System Using Production Information (생산정보를 이용한 자동차 조립 서열시스템에 관한 연구)

  • Ock, Young-Seok;Kim, Byung Soo;Bae, Jun-Hee
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.37 no.3
    • /
    • pp.8-15
    • /
    • 2014
  • For zero inventory and mixed assembly production, JIT (Just In Time) production system in Toyota and JIS (Just-In-Sequence) production system in Hyundai motor co. have been proposed in automobile production areas. Even though the production systems are popular in the areas, many subcontract companies producing part-modules for final production at a parent company suffers from excessive or shortage amount of inventory due to the time gap of production and delivery to the parent company. In this study, we propose an efficient real-time assembly sequence system applying a well-known Pareto method using Paint-In information in painting process and daily production planning information. Based on this system, a production line can estimate the shortage amount of UPH (Units Per Hour) at production line and recovers the amount before operating assembly production in the line. The proposed system provides efficiency on productivity compared with the previous system.

Exposure to Noise on Railroad Operators (철도 차량 운전원의 소음노출 특성)

  • Lee, Sang-Yun;Choi, Sang-Jun
    • Journal of Environmental Health Sciences
    • /
    • v.34 no.2
    • /
    • pp.153-160
    • /
    • 2008
  • Personal noise exposure was assessed in railroad operators working in 40 operation units including the Gyeongbu line, Honam line, and Janghang line between 2004 and 2006. 8-hour TWA were assessed based on the MOL (Ministry of Labor) guideline on noise evaluation, and 17% of these measurements exceeded 85 dBA while 70% were over 80 dBA. When the ACGIH TLV is adopted, 40% of measurements were over TLV (85 dBA). The noise exposure risk of railroad operators was higher for diesel locomotive operation and longer operational distances; in addition, the risk was higher for passenger car operation compared to freight car driving. Given that in Korea, over the past 30 years diesel locomotives have provided most of the railway's motive power and that hearing protective equipment is not likely to be used by workers during operation, railroad operators are at a high risk of noise-induced hearing loss. The result of audiometric test among 568 railroad operators showed that 32.6% of those tested had a hearing threshold shift of more than 40 dB. In conclusion, this study calls for more fundamental measures including noise control countermeasures within the operation areas, development of equipment that generates less noise and adopting limitation on the operation distance for a work shift.