• Title/Summary/Keyword: hot-plate

Search Result 690, Processing Time 0.023 seconds

Experimental Studies on the Analgesic and Antiphlogistic Effects of Violae Herba (자화지정(紫花地丁)의 진통(鎭痛) 및 소염작용(消炎作用)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Ko, Wun-Che;Shin, Min-Kyo
    • Korean Journal of Pharmacognosy
    • /
    • v.18 no.4
    • /
    • pp.210-215
    • /
    • 1987
  • Experimental studies were done to investigate analgesic and antiphlogistic actions of Violae Herba. Its water extract showed a significant dose dependent analgesic effect against writhing syndrome induced by acetic acid as well as in hot plate test in mice. The extract also showed a significant inhibitory effect against paw-edema induced by egg-white in rats.

  • PDF

다이오드 레이저를 이용한 이방 전도성 필름(ACF) 접합

  • 류광현;서명희;남기중;곽노흥
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2005.09a
    • /
    • pp.45-48
    • /
    • 2005
  • 디스플레이 모듈에서 hot plate를 이용한 이방 전도성 필름(ACF: Anisotropic Conductive Film) 접합의 공정을 고출력 다이오드 레이저를 이용한 공정으로 대체하였다. 다이오드 레이저를 이용한 ACF 접합은 공정 시간을 기존보다 줄일 수 있으며 평탄도 및 응용성에 있어서 hot plate 공정보다 뛰어나다. 또한 다양한 샘플에도 지그 및 레이저광의 자유로운 변형으로 응용성이 매우 뛰어나다. 에너지 분포가 고른 선광을 이용하여 ACF 접합을 수행하였다. 레이저 에너지 밀도 $100\;W/cm^2$, 압력 20 kg, 레이저 조사시간 4초 이상에서 800 gf/cm 이상의 인장력을 얻을 수 있었고 기존의 공정 시간을 두 배 이상 단축하였다.

  • PDF

Application of Press Quenching Technology to Automotive Drive Plate (프레스 퀜칭에 의한 자동차 드라이브 플레이트 제조에 관한 연구)

  • Jeong, W.C.
    • Transactions of Materials Processing
    • /
    • v.20 no.8
    • /
    • pp.588-594
    • /
    • 2011
  • A new manufacturing process is presented for automotive drive plate using a boron-containing carbon steel sheet, which is hot-formed and press quenched. Particular attention was given to the capability of the process in minimizing dimensional change.

Effect of Non-Metallic Inclusions and Hot Rolling Process Parameters on Hydrogen Induced Cracking of Linepipe Steels (라인파이프 강재의 수소유기균열에 미치는 열간압연 공정변수의 영향)

  • Koh, Seong Ung;Jung, Hwan Gyo;Kang, Ki Bong
    • Korean Journal of Metals and Materials
    • /
    • v.46 no.4
    • /
    • pp.257-266
    • /
    • 2008
  • AHydrogen induced cracking (HIC) was phenomenologically studied in terms of the effect of nonmetallic inclusions and hot rolling process parameters. By comparing the level of non-metallic inclusions in two different kinds of commercial grade steels having different HIC resistance, the role of non-metallic inclusions in HIC occurrence was investigated. Change in inclusion morphology and distribution during hot rolling was also studied throughout slab, rolling at austenite recrystallization region (roughing mill; RM) and rolling at austenite non-recrystallization region (finish mill; FM). In addition, the contribution of RM and FM parameters to HIC was investigated from the standpoint of change in inclusion morphology during hot rolling processes. As a result, HIC was closely related to the separation of large complex inclusion during hot rolling process. Large complex inclusions originated from the improper Ca treatment, after which equilibrium composition of slag should have resulted in eutectoid composition. By controlling the equilibrium slag composition equivalent to eutectoid one, HIC resistance could be improved due to the reduced size of inclusions. In addition, change in reduction/pass in RM had an effect on HIC resistance of steels while that in FM did not. Increase in the reduction/pass in the latter stage of RM improved HIC resistance of steels by enhancing the void enclosure around inclusions.

Numerical and Experimental Approach to Investigate Plane-view Shape and Crop Loss in Multistage Plate Rolling (다단 후판압연에서 평면형상 및 실수율 고찰을 위한 수치적, 실험적 연구)

  • Byon, Sang Min
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.9
    • /
    • pp.1117-1125
    • /
    • 2013
  • A finite element based approach that can be used to investigate the plane-view shape and crop loss of a material during plate rolling is presented. We employed a three-dimensional finite element model to continuously simulate the shape change of the head and tail of a plate as the number of rolling passes increases. The main feature of the proposed model lies in the fact that the multistage rolling can be simulated without a break because the rolling direction of the material is reversibly controlled as the roll gap sequentially decreases. The material constants required in the finite element analysis were experimentally obtained by hot tensile tests. We also performed a pilot hot plate rolling test to verify the usefulness of the proposed finite element model. Results reveal that the computed plane-view shapes as well as crop losses by the proposed finite element model were in good agreement with the measured ones. The crop losses predicted by the proposed model were within 5% of those measured from the pilot hot plate rolling test.

Effect of Water Temperature on Heat Transfer Characteristic of Spray Cooling on Hot Steel Plate (냉각수온 효과에 따른 고온 강판의 스프레이 냉각 열전달 특성 연구)

  • Lee, Jung-Ho;Yu, Cheong-Hwan;Park, Sang-Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.5
    • /
    • pp.503-511
    • /
    • 2011
  • Water spray cooling is a significant technology for cooling of materials from high-temperature up to $900^{\circ}C$. The effects of cooling water temperature on spray cooling are mainly provided for hot steel plate cooling applications in this study. The heat flux measurements are introduced by a novel experimental technique that has a function of heat flux gauge in which test block assemblies are used to measure the heat flux distribution on the surface. The spray is produced by a fullcone nozzle and experiments are performed at fixed water impact density of G and fixed nozzle-totarget spacing. The results show that effects of water temperature on forced boiling heat transfer characteristics are presented for five different water temperatures between 5 to $45^{\circ}C$. The local heat flux curves and heat transfer coefficients are also provided to a benchmark data for the actual spray cooling of hot steel plate cooling applications.

The Effect of Nozzle Height on Heat Transfer of a Hot Steel Plate Cooled by an Impinging Water Jet (충돌수분류에 냉각되는 고온 강판의 열전달에 있어 노즐높이의 영향에 대한 연구)

  • Lee, Pil-Jong;Choi, Hae-Won;Lee, Sung-Hong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.5
    • /
    • pp.668-676
    • /
    • 2003
  • The effect of nozzle height on heat transfer of a hot steel plate cooled by an impinging liquid jet is not well understood. Previous studies have been based on the dimensionless parameter z/d. To test the validity of this dimensionless parameter and to investigate gravitational effects on the jet, stagnation velocity of an impinging liquid jet were measured and the cooling experiments of a hot steel plate were conducted for z/d from 6.7 to 75, and an inverse heat conduction method is applied for the quantitative comparison. Also, the critical instability point of a liquid jet was examined over a range of flow rates. The experimental velocity data for the liquid jet were well correlated with the dimensionless number 1/F $r_{z}$$^2$based on distance. It was thought that the z/d parameter was not valid for heat transfer to an impinging liquid jet under gravitational forces. In the cooling experiments, heat transfer was independent of z when 1/F $r_{z}$$^2$< 0.187(z/d = 6.7). However, it was found that the heat transfer quantity for 1/F $r_{z}$$^2$=0.523(z/d = 70) is larger 11% than that in the region for 1/F $r_{z}$$^2$=0.187. The discrepancy between these results and previous research is likely due to the instability of liquid jet.uid jet.

Effects of the Essential Oil from Modified SuHeXiang Wan (Storax Pill) in Mice after Inhalation, Oral Administration, and Inunction (가감소합향원(加減蘇合香元) 정유향기(精油香氣)의 흡입(吸入), 경구투여(經口投與) 및 피부도찰(皮膚塗擦)에 따른 진통효과(鎭痛效果) 비교(比較))

  • Kim, Seong-Soo;Park, Kwang-Rock;Lee, Dong-Ung;Koo, Byung-Soo
    • Journal of Oriental Neuropsychiatry
    • /
    • v.19 no.2
    • /
    • pp.223-230
    • /
    • 2008
  • 소합향원 (蘇合香元) 가감방(加減方) 정유향기의 진통효과가 투여방법에 따라 어떤 차이가 있는지를 비교, 검토함으로서 본 약재의 새로운 적용방법을 탐색해 보고자 한다. 방법 : 가감소합향원에서 추출한 정유향기를 실험동물을 대상으로 7일간 경구 (50mg/kg, 100mg/kg), 흡입 (매일 3시간씩 1일 2회), 또는 피부도찰 (10mg) 방법으로 투여하여 페닐퀴논-유도 writhing test, 아세트산-유도 writhing test 및 hot-plate test를 실시하였다. 결과 : 가감소합향원 정유향기는 페닐퀴논-유도 writhing test에서는 피부도찰이 가장 효과적 이었으며 그 효과는 양성 대조약물인 아세트아미노펜 보다 약간 더 우수하였다 (p<0.05). 아세트산-유도 writhing test에서도 피부도찰법이 가장 좋은 효과를 나타내었으며 양성대조 약물인 아미노피린보다는 좀 더 좋은 효과를 보여주었다 (p<0.05). 그러나 hot-plate test에서는 경구투여가 가장 좋은 진통효과를 나타내었는데 고용량 (100mg/kg)에서는 양성 대조약물인 아세트아미노펜보다 유의적으로 더 효과적이었으나 저용량 (50mg/kg )에서는 이보다 다소 약하였다. 이상의 연구결과, 가감소합향원의 정유향기는 피부도찰시에는 비특이적 화학자극제인 페닐퀴논이나 아세트산에 의한 통증의 완화에 보다 효과적이며, 경구투여시에는 중추신경계에 영향을 미치는 hot plate에 의한 열자극성 통증에 더 유효함을 의미한다. 결론 : 가감소합향원의 정유향기액은 향기흡입보다는 피부흡수나 경구투여방법으로 진통의 목적으로 응용될 수 있을 것으로 사료된다.

  • PDF

Experimental Study on Correction of Thermal Conductivity Obtained by Heat Flow Method using Commercial Guarded Hot Plate Method Apparatus (상용 보호열판법 열전도율 측정장비를 사용한 열유속법의 열전도율 값 보정에 대한 실험적 연구)

  • Lee, Jin-Sung;Kim, Kyung-Su;Kim, Yooil;Woo, Suck-Min;Yun, Seungjin
    • Journal of Ocean Engineering and Technology
    • /
    • v.29 no.2
    • /
    • pp.169-174
    • /
    • 2015
  • This paper addresses experimental methodologies to measure the temperature-dependent thermal conductivity of the insulation materials popularly used for LNG cargo containment systems. The measurement techniques considered in this paper are the guarded hot plate (GHP) method and heat flow method (HFM). The former is based on the power supplied to the hot plate to keep the temperature constant, and the latter is based on a direct heat flux measurement. In order to improve the accuracy of the HFM, the thermal conductivity obtained by GHP was cross-compared with the HFM results, and a calibration factor was derived. It was found that the thermal conductivities measured by the two methods corresponded well under room temperature, but the deviation tended to slightly increase as the temperature decreased. Because of the easy installation and operability of HFM, it can be used to measure thermal conductivity in a large scale mock-up test or unit insulation panel test, where the GHP method is difficult to apply.

A Study on Thermal Storage Performance and Characteristics of Daily Operation of a Hybrid Solar Air-Water Heater (복합형 태양열 가열기의 일일 운전 특성 및 축열 성능에 관한 연구)

  • Choi, Hwi-Ung;Rokhman, Fatkhur;Yoon, Jung-In;Son, Chang-Hyo;Choi, Kwang-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.3
    • /
    • pp.73-79
    • /
    • 2015
  • In this study, a thermal storage performance and characteristics of daily operation were investigated when the air and the liquid were heated simultaneously by a hybrid solar air-water heater that can make hot water as well as heated air. The hybrid solar air-water heater is kind of a flat plate solar collector that can make hot water and heated air by installing air channel beneath absorber plate of traditional flat plate solar collector for hot water. As a result of daily operation, maximum water temperature reached in a thermal storage was shown $44^{\circ}C$ on 73kg/h of air mass flow rate and about $40^{\circ}C$ on 176kg/h of air mass flow rate. Thus, the necessity of heating water in thermal storage by operating only liquid side was confirmed when the temperature of liquid in thermal storage is lower than we need. In case of efficiency investigated on daily operation, the thermal efficiency of the liquid side was decreased with increment of the inlet liquid temperature and decrement of the solar radiation, but efficiency of the air side was increased with increment of inlet liquid temperature difference as the traditional solar air heater. Total thermal efficiency of the collector was shown from 65.85% to 78.23% and it was decreased with increment of the inlet liquid temperature and decrement of solar radiation same as the traditional system.