• 제목/요약/키워드: hot drawing

검색결과 49건 처리시간 0.023초

ULTRAVIOLET COLOR - COLOR RELATION OF EARLY-TYPE GALAXIES AT 0.05

  • 이창희;정현진;오규석;정철;이준협;김상철;경재만
    • 천문학회보
    • /
    • 제37권1호
    • /
    • pp.48.1-48.1
    • /
    • 2012
  • We present the ultraviolet (UV) color-color relation of early-type galaxies (ETGs) in the nearby universe (0.05 < z < 0.12) to investigate the properties of hot stellar populations responsible for the UV excess (UVX). The initial sample of ETGs is selected by the spectroscopic redshift and the morphology parameter from the SDSS DR 7, and then cross-matched with the GALEX far-UV (FUV) and near-UV (NUV) GR6 data. The cross-matched ETG sample is further classified by their emission line characteristics in the optical spectra into quiescent, star-forming, and active galactic nucleus categories. Contaminations from early-type spiral galaxies, mergers, and morphologically disturbed galaxies are removed by visual inspection. By drawing the FUV-NUV (as a measure of UV spectral shape) versus FUV-r (as a measure of UVX strength) diagram for the final sample of -3700 quiescent ETGs, we find that the "old and dead" ETGs consist of a well-defined sequence in UV colors, the "UV red sequence," so that the stronger UVX galaxies should have a harder UV spectral shape systematically. However, the observed UV spectral slope is too steep to be reproduced by the canonical stellar population models in which the UV flux is mainly controlled by age or metallicity parameters. Moreover, 2 mag of color spreads both in FUV-NUV and FUV-r appear to be ubiquitous among any subsets in distance or luminosity. This implies that the UVX in ETGs could be driven by yet another parameter which might be even more influential than age or metallicity.

  • PDF

열간 스피닝 공정을 통한 CNG 고압용기의 돔 및 입구 부 성형 (Forming of Dome and Inlet Parts of a High Pressure CNG Vessel by the Hot Spinning Process)

  • 이광오;박건영;곽효서;김철
    • 대한기계학회논문집A
    • /
    • 제40권10호
    • /
    • pp.887-894
    • /
    • 2016
  • 압축천연가스(CNG) 압력용기는 D.D.I공정을 통해 실린더부를 제작한 후, 스피닝 공정을 통해 돔 부 성형이 이루어진다. 그러나 스피닝 공정의 입구 부 성형에 관한 연구는 미미하며, 현장 작업자들의 경험이나 시행착오에 의해 제작되고 있는 실정이다. 이에 본 연구에서는 이론 임계좌굴하중 및 유한요소해석에서 축 방향 하중의 비교를 통하여 좌굴발생을 예측하였고, 상용 소프트웨어를 이용하여 돔부의 좌굴 방지를 위한 방법을 제안하였다. 또한, 입구 부 성형을 위하여 돔 부와 롤러가 맞닿는 점에서의 돔부의 반경에 따른 롤러 하중을 분석하고, 이를 토대로 입구 부 성형을 수행하였다.

가시오가피와 수종 한약자원 혼합 조성물이 고지방 식이에 있어 혈청 지질농도에 미치는 효과 (Effects of Eleutherococcus senticosus and Several Oriental Medicinal Herbs Extracts on Serum Lipid Concentrations)

  • 최화선;김영희;한종현;박성혜
    • 한국식품영양학회지
    • /
    • 제21권2호
    • /
    • pp.210-217
    • /
    • 2008
  • This study evaluated the hypolipidemic effects of Eleutherococcus senticosus combined with several oriental medicinal herbs. In addition, it addressed whether consuming a diet of healthy food along with a daily supplement of this composite could affect the health status of individuals suffering from diet-related disease such as obesity and hyperlipidemia. The effects of the combined medicinal herbal extracts(MHE) extracted with hot water on reducing serum lipids and improving blood parameters were examined in rats fed a high-fat diet for 5 weeks. Sprague-Dawley rats were randomly assigned to 4 groups: basal diet only(BDG), high fat diet without MHE(FCG), high fat diet and 10% MHE(F10E) and high fat diet and 20% MHE(F20E). Serum lipid contents and blood variables were examined after the experimental period. The results of were as follows. The hematological data for the 4 groups were similar indicating no significant differences. There were moderate level of serum GOT activity in the F10E and F20E groups as compared to the FCG group. Total cholesterol, LDL-cholesterol, triglyceride in serum and the atherogenic index were remarkably reduced in the MHE-supplemented groups as compared to the control group. However, F10E and F20E groups had significantly higher HDL-cholesterol levels than the control group. These results imply that combination of several medicinal herbal extracts could be used to reduce of serum lipid concentrations. The data from this study will be used as basic information with the field of functional food research to address how we can apply oriental medicinal resources to foods. Such research currently drawing considerable attention world-wide.

Implication of microRNA as a potential biomarker of myocarditis

  • Oh, Jin-Hee;Kim, Gi Beom;Seok, Heeyoung
    • Clinical and Experimental Pediatrics
    • /
    • 제65권5호
    • /
    • pp.230-238
    • /
    • 2022
  • Myocarditis was previously attributed to an epidemic viral infection. Additional harmful reagents, in addition to viruses, play a role in its etiology. Coronavirus disease 2019 (COVID-19) vaccine-induced myocarditis has recently been described, drawing attention to vaccine-induced myocarditis in children and adolescents. Its pathology is based on a series of complex immune responses, including initial innate immune responses in response to viral entry, adaptive immune responses leading to the development of antigen-specific antibodies, and autoimmune responses to cellular injury caused by cardiomyocyte rupture that releases antigens. Chronic inflammation and fibrosis in the myocardium eventually result in cardiac failure. Recent advancements in molecular biology have remarkably increased our understanding of myocarditis. In particular, microRNAs (miRNAs) are a hot topic in terms of the role of new biomarkers and the pathophysiology of myocarditis. Myocarditis has been linked with microRNA-221/222 (miR-221/222), miR-155, miR-10a*, and miR-590. Despite the lack of clinical trials of miRNA intervention in myocarditis yet, multiple clinical trials of miRNAs in other cardiac diseases have been aggressively conducted to help pave the way for future research, which is bolstered by the success of recently U.S. Food and Drug Administration-approved small-RNA medications. This review presents basic information and recent research that focuses on myocarditis and related miRNAs as a potential novel biomarker and the therapeutics.

상업지역의 초미세먼지(PM2.5) 발생특성 연구 (Characteristics of PM2.5 Emission and Distribution in a Highly Commercialized Area in Seoul, Korea)

  • 서영호;구명성;최진원;김경민;김상미;설경화;조효재;김수진;김기현
    • 한국대기환경학회지
    • /
    • 제31권2호
    • /
    • pp.97-104
    • /
    • 2015
  • The pollution of particulate matter (PM) is considered one of the hot socioenvironmental issues at present time. In this study, we investigated the distribution of fine particulate matter ($PM_{2.5}$) in Wangsimni commercial areas in Seoul, Korea to learn more about its environmental behavior in an urban area. Our analysis of $PM_{2.5}$ was made to distinguish the $PM_{2.5}$ pollution levels between three different types of site characteristics: (1) densely populated area, (2) thinly populated area, and (3) traffic roadside. Moreover, to assess the temporal trends in our study, the concentration levels of $PM_{2.5}$ were also compared between weekdays and weekends and between early in the afternoon and evening. The average concentration of $PM_{2.5}$ from densely and thinly populated areas were measured as $36.0{\pm}13.1$ and $32.3{\pm}11.2{\mu}g/m^3$, respectively. If the results are compared between different time bands, there were apparent differences between weekdays ($29.6{\pm}10.8{\mu}g/m^3$) and weekends ($36.9{\pm}12.1{\mu}g/m^3$). Such difference was also evident between noon ($27.8{\pm}5.8{\mu}g/m^3$) and evening ($38.3{\pm}13.7{\mu}g/m^3$). According to our research, concentration of $PM_{2.5}$ in the study area was affected more sensitively by time zone rather than the population density. The measurement data was also analyzed by drawing concentration map of $PM_{2.5}$ in the Wangsimni commercial areas based on data contouring method.

SPECT/CT 영상에서 에너지창 기반 산란보정과 CT 기반 산란보정 방법의 정량적 정확성 비교 (The Comparison of Quantitative Accuracy between Energy Window-Based and CT-Based Scatter Correction Method in SPECT/CT Images)

  • 김지현;이주영
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권2호
    • /
    • pp.135-143
    • /
    • 2022
  • In SPECT image, scatter count is the cause of quantitative count error and image quality degradation. This study is to evaluate the accuracy of CT based SC(CTSC) and energy window based SC(EWSC) as the comparison with existing Non SC. SPECT/CT images were obtained after filling air in order to acquire a reference image without the influence of scatter count inside the Triple line insert phantom setting hot rod(99mTc 74.0 MBq) in the middle and each SPECT/CT image was obtained each separately after filling water instead of air in order to derive the influence of scatter count under the same conditions. For EWSC, 9 sub-energy windows were set additionally in addition to main energy window(140 keV, 20%) and then, images were acquired at the same time and five types of EWSC including DPW(dual photo-peak window)10%, DEW(dual energy window)20%, TEW(triple energy window)10%, TEW5.0%, TEW2.5% were used. Under the condition without fluctuations in primary count, total count was measured by drawing volume of interest (VOI) in the images of the two conditions and then, the ratio of scatter count of total counts was calculated as percent scatter fraction(%SF) and the count error with image filled with water was evaluated with percent normalized mean-square error(%NMSE) based on the image filled with air. Based on the image filled with air, %SF of images filled with water to which each SC method was applied is non scatter correction(NSC) 37.44, DPW 27.41, DEW 21.84, TEW10% 19.60, TEW5% 17.02, TEW2.5% 14.68, CTSC 5.57 and the scatter counts were removed the most in CTSC and %NMSE is NSC 35.80, DPW 14.28, DEW 7.81, TEW10% 5.94, TEW5% 4.21, TEW2.5% 2.96, CTSC 0.35 and the error in CTSC was found to be the lowest. In SPECT/CT images, the application of each scatter correction method used in the experiment could improve the quantitative count error caused by the influence of scatter count. In particular, CTSC showed the lowest %NMSE(=0.35) compared to existing EWSC methods, enabling relatively accurate scatter correction.

액정 폴리에스테르/PEN 블렌드 섬유의 성질 (Properties of Liquid Crystalline Polyester/Poly(ethylene 2,6-naphthalate) Blend Fibers)

  • 김원;김영용;손정선;윤두수;한철;최재곤;조병욱
    • Elastomers and Composites
    • /
    • 제37권4호
    • /
    • pp.244-257
    • /
    • 2002
  • 주사슬에 나프탈렌고리와 테트라메틸렌 및 헥사메틸렌 유연격자를 가지면서 트라이어드메소겐을 갖는 새로운 열방성 방향족 액정 폴리에스테르(TLCP)를 용액중합법에 의하여 합성하였다. TLCP의 함량을 달리하는 TLCP/PEN in situ 복합재료를 용융방사하여 연신비가 각각 다른 단섬유를 제조하고 그들의 열적, 기계적 특성 및 모폴로지를 조사하였다. 합성된 TLCP는 네마틱 액정중합체였으며 고체상에서 액정상으로의 전이 온도는 249 ℃였다. 블렌드내의 TLCP 도메인들은 매트릭스 고분자인 PEN에 잘 분산 되었으며 어떠한 거대 상 분리 현상도 보여 주지 않았다. TLCP 함량의 증가에 따른 블렌드내 PEN의 cold crystallization 온도가 낮아진 것으로 보아서 TLCP가 PEN에 대한 조핵제 역할을 하였음을 알 수 있었다. 블렌드 섬유내의 TLCP의 도메인 크기는 대략 40 ~ 50 nm정도의 미세한 크기였으며 매트릭스와의 사이에 좋은 계면 접착력을 보였다. 또한 cold 및 hot-drawing 과정을 거친 낮은 draw ratio(DR)에서는 거의 fibril이 형성되지 않았지만, 높은 DR에서는 잘 발달된 fibril들을 보여 주었다. TLCP의 강화효과로 인하여 10 wt% TLCP/ PEN 블렌드 섬유의 초기 모듈러스는 270 %, 인장강도는 235 %의 증가를 보여주었다. 반면에 신장률은 DR의 증가와 함께 감소 하였다.

SPECT/CT 영상에서 에너지창 기반 산란보정과 CT 기반 산란보정 방법의 정량적 정확성 비교 (The Comparison of Quantitative Accuracy Between Energy Window-Based and CT-Based Scatter Correction Method in SPECT/CT Images)

  • 김지현;손현수;이주영;박훈희
    • 핵의학기술
    • /
    • 제19권2호
    • /
    • pp.93-101
    • /
    • 2015
  • SPECT영상에서 산란계수는 정량적 계수오차와 영상품질 저하의 요인이다. 이에 다양한 산란보정(Scatter Correction, SC)방법이 연구되어 왔으며, 본 연구에서는 기존의 에너지창(Energy Window, EW) 기반 SC(EWSC)와의 비교로 SPECT/CT에서 사용되는 CT 기반 SC(CTSC)의 정확성을 평가하고자 한다. 중앙에 열소막대(hot rod, 74.0 MBq)를 설정한 Triple line insert 팬텀의 내부에 산란계수의 영향이 없는 기준영상의 획득을 위하여 공기를 채운 후 SPECT /CT영상을 획득하였고, 같은 조건에서 산란계수의 영향을 유도하기 위하여 공기대신 물을 채운 후 SPECT/CT영상을 각각 별도로 획득하였다. 두 조건 모두 Astonish(iterative : 4, subset : 16) 재구성 방법과 CT감쇠보정을 공통 적용하였고, 물을 채운 영상에 비산란보정(NSC), EWSC, CTSC 3가지 유형의 산란보정방법을 사용하였다. EWSC를 위하여 주(=peak) 에너지창(140 keV, 20%) 이외에 보조 에너지창 9개를 추가 설정한 후 영상을 동시 획득하였고, EWSC의 종류는 DPW(dual photopeak window) 10%, DEW (dual energy window)20%, TEW(triple energy window)10%, TEW5.0%, TEW2.5% 5가지를 사용하였다. 일차(primary)계수의 변동이 없는 조건하에, 두 조건의 영상에 VOI를 그려 총계수를 측정한 후 총계수 중 산란계수의 비를 %SF(percent scatter fraction)로 구하고, 공기를 채운 영상을 기준으로 물을 채운 영상과의 계수차이를 %NMSE (per cent normalized mean-square error)로 평가하였다. 공기를 채운 영상을 기준으로 각 산란보정방법이 적용된 물을 채운 영상의 %SF는 NSC 37.44, DPW 27.41, DEW 21.84, TEW10% 19.60, TEW5% 17.02, TEW2.5% 14.68, CTSC 5.57로 CTSC에서 제거된 산란계수가 가장 많았으며, %NMSE는 NSC 35.80, DPW 14.28, DEW 7.81, TEW10% 5.94, TEW5% 4.21, TEW2.5% 2.96, CTSC 0.35로 CTSC에서 가장 낮게 나타났다. SPECT/CT영상에서 실험에 사용된 각 산란보정 방법의 적용은 산란계수의 영향으로 발생된 정량적 계수오차를 개선시킬 수 있었다. 특히, CTSC의 경우 기존의 EWSC방법들과 비교하여 가장 낮은 %NMSE (=0.35)를 보여 비교적 정확한 산란보정이 가능하였다.

  • PDF

자궁경부암의 강내조사치료에 있어서 흠수선량평가시 골반강 자기공명사진의 응용 (Pelvic MRI Application to the Dosimetric Analysis in Brachytherapy of Uterine Cervix Carcinoma)

  • 정웅기;나병식;안성자
    • Radiation Oncology Journal
    • /
    • 제15권1호
    • /
    • pp.57-64
    • /
    • 1997
  • 목적 : 자궁경부암환자의 근치목적의 방사선치료 성적을 보고하기에 앞서 본원에서 사용하고 있는 자궁강내치료기기의 선량투여 방법의 정확성을 평가해보고 각 장기의 흡수선량을 대변할수 있는 예측력이 어느정도인지 알아보고자 연구를 시행하였다. 대상 및 방법 : 조준필름의 측면사진에서는 본원에서 현재 사용중인 방광(SBD)과 직장(SRD)의 기준흡수점의 흡수선량을 확인 하였다. 골반강 자기공명상의 측면사진에서 종양의 두 횡축과 종축의 직경을 곱하여 종양부피(TV)를 측정하였고, 기본으로 사음되고 있는 등선량곡선을 그린후 선량기준점 A 의 등선량 곡선내에 자궁경부 종양이 포함되는지 대상 환자별로 확인하였으며, 방광(MBD)과 직장(MRD)에서 보여주는 최대흡수선량점의 값을 측정하였고, 또한 선량기준점 A의 등선량 곡선내에 포함되는 방광(HBV)과 직장(HRV)의 면적을 계산해 보았다. 결 과 : 45례를 대상으로 분석하였다. 이중 53%(24/45) 에서만이 선량기준점 A의 등선량곡선내에 종양이 잘 포함되었다. 적절한 포함정도는 병기보다는 원발종양의 크기와 통계학적으로 유의한 관련성을 보여주었으며 종양의 측면지름의 크기가 3cm 이상인 종양은 불충분한 포함을 보여 주었다. 조준필름의 측면상의 방광과 직장의 기준흡수선량값은 자기공명사진상의 방광과 직장의 최대흡수값과 각각 유의한 관계를 보여주지 못했으나, 조준필름의 직장의 흡수선량값(SRD)은 HRV 와 유의한 관련성을 보여주었다. HBV 이나 HRV 은 오히려 자기공명사진상에서 측정한 종양의 크기(TV) 와 유의한 연관성을 보여 주었다. 결론 : 본원에서 사용하고 있는 선량계산 방법은 개별적인 종양의 크기를 고려해주지 못하였으며, 특히 방광의 흡수선량계산에 있어서 실제 흡수선량을 대변할수 있는 예측도가 낮아서 이에 대한 환자 개개인의 종양의 특성을 고려한 선량계산이 필요하리라 사료되는 바이다.

  • PDF