• Title/Summary/Keyword: horizontal load

Search Result 954, Processing Time 0.022 seconds

Lateral Earth Pressures and Displacements through Full Scaled Lateral Loading Test of Concrete Electric Pole Embedded in Ground (지중에 근입된 콘크리트전주의 실물 수평재하실험에 의한 수평토압과 변위특성)

  • Ahn, Tae-Bong
    • Journal of the Korean GEO-environmental Society
    • /
    • v.12 no.4
    • /
    • pp.43-51
    • /
    • 2011
  • Many electric poles in the softground have been collapsed due to external load. In this study, 10 types of tests were performed with variation of location, numbers and depths of anchor blocks as well as depth of poles to find horizontal earth pressure through full scale pull-out tests. The horizontal earth pressure increased with embedded depth of electric pole, and earth pressure of lower passive zone decreased. The deeper of anchor block, earth pressure of passive zone becomes less. lateral displacements showed differences depending on location, numbers and depth of poles. The bending is generated in the upper part at the initial load, but it moved to central part as load increased. The maximum horizontal displacement decreased to 1/1.6 at -0.5m depth of anchor block and 1.3m additional laying depth of poles into ground.

A Study on the Stress Distribution of Condylar Region and Edentulous Mandible with Implant-Supported Cantilever Fixed Prostheses by using 3-Dimensional Finite Element Method (임플란트 지지 캔틸레버 고정성 보철물 장착시 과두와 하악골의 응력 분포에 관한 3차원 유한요소법적 연구)

  • Kim, Yeon-Soo;Lee, Sung-Bok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.17 no.4
    • /
    • pp.283-305
    • /
    • 2001
  • The purpose of this study was to analyze the stress distribution of condylar regions and edentulous mandible with implant-supported cantilever prostheses on the certain conditions, such as amount of load, location of load, direction of load, fixation or non-fixation on the condylar regions. Three dimensional finite element analysis was used for this study. FEM model was created by using commercial software, ANSYS(Swanson, Inc., U.S.A.). Fixed model which was fixed on the condylar regions was modeled with 74323 elements and 15387 nodes and spring model which was sprung on the condylar regions was modeled with 75020 elements and 15887 nodes. Six Br${\aa}$nemark implants with 3.75 mm diameter and 13 mm length were incorporated in the models. The placement was 4.4 mm from the midline for the first implant; the other two in each quardrant were 6.5 mm apart. The stress distribution on each model through the designed mandible was evaluated under 500N vertical load, 250N horizontal load linguobuccally, buccal 20 degree 250N oblique load and buccal 45 degree 250N oblique load. The load points were at 0 mm, 10 mm, 20 mm along the cantilever prostheses from the center of the distal fixture. The results were as follows; 1. The stress distribution of condylar regions between two models showed conspicuous differences. Fixed model showed conspicuous stress concentration on the condylar regions than spring model under vertical load only. On the other hand, spring model showed conspicuous stress concentration on the condylar regions than fixed model under 250N horizontal load linguobuccally, buccal 20 degree 250N oblique load and buccal 45 degree 250N oblique load. 2. Fixed model showed stress concentration on the posterior and mesial side of working and balancing condylar necks but spring model showed stress concentration on the posterior and mesial side of working condylar neck and the posterior and lateral side of balancing condylar neck under vertical load. 3. Fixed model showed stress concentration on the posterior and lateral side of working condylar neck and the anterior and mesial side of balancing condylar neck but spring model showed stress concentration on the anterior sides of working and balancing condylar necks under horizontal load linguobuccally. 4. Fixed model showed stress concentration on the posterior side of working condylar neck and the posterior and lateral side of balancing condylar neck but spring model showed stress concentration on the anterior side of working condylar neck and the anterior and lateral side of balancing condylar neck under buccal 20 degree oblique load. 5. Fixed model showed stress concentration on the anterior and lateral side of working condylar neck and the posterior and mesial side of balancing condylar neck but spring model showed stress concentration on the anterior side of working condylar neck and the anterior and lateral side of balancing condylar neck under buccal 45 degree oblique load.. 6. The stress distribution of bone around implants between two models revealed difference slightly. In general, magnitude of Von Mises stress was the greatest at the bone around the most distal implant and the progressive decrease more and more mesially. Under vertical load, the stress values were similar between implant neck and superstructure vertically, besides the greatest on the distal side horizontally. 7. Under horizontal load linguobuccally, buccal 20 degree oblique load and buccal 45 degree oblique load, the stress values were the greatest on the implant neck vertically, and great on the labial and lingual sides horizontally. After all, it was considered that spring model was an indispensable condition for the comprehension of the stress distributions of condylar regions.

  • PDF

Analyses of Horizontal Behavior of Guardrail Posts Installed in Compacted Weathered Granite Soil (화강풍화토 지반에 타설된 가드레일 지주의 횡방향 거동 분석)

  • Lim, Yu-Jin;Hai, Nguyen Tien
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.41-48
    • /
    • 2005
  • A small scale impact apparatus, pressuremter and soil chamber were used to investigate horizontal behavior and bearing capacity of the steel guardrail post installed in compacted soil. A useful test and data reduction method for pressuremter was developed to evaluate soil parameters of surrounding soil and stability of the post. From the analyses of the PMT, horizontal bearing capacity of the post impacted by a boggie was 12.7% bigger than that of the post with static loading. The increased horizontal bearing capacity is due to generated inertia force that is dependent on the shape of failed soil wedge around the post. P-y curves were obtained from the pressuremeter test and were applied to a finite difference program which predicted a load-deflection and a bending moment contours along the post.

  • PDF

Developement of Consolidation Cell of Horizontal Drainage using Standard Consolidation Tester (표준압밀시험기를 사용하는 수평배수 압밀셀의 개발)

  • Ju, Jae-Woo;Cheong, Gyu-Hyang;Cho, Sam-Deok;Lee, Chun-Ju;Park, Jong-Beom
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2004.03b
    • /
    • pp.678-683
    • /
    • 2004
  • The most popular consolidation tester is a standard consolidatiion tester, which performs consolidation using the step load weight. However this apparatus is used to obtain only the vertical consolidation coefficient. Therefore the purpose of this study is to develope the horizontal consolidation cell for a horizaontal consolidation coefficient. Various size of tests have been peroformed to investigate the effect of scale effect. From the test results, it has turned out that this horizontal consolidation cell has a good function for a horizontal consolidation coefficient.

  • PDF

The effect on fatigue life for dynamic behavior of external fuel tank horizontal fin (외부 연료탱크 수평 핀 동적거동이 피로수명에 미치는 영향)

  • Kim, Geun-Won;Shin, Ki-Su
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.40 no.3
    • /
    • pp.209-214
    • /
    • 2012
  • Recently, there were significantly increased cracks failure for external fuel tank horizontal fin of F-5 aircraft. In this paper, the dynamic behavior of horizontal fin was to quantitate by using Finite Element Method. To achieve this goal, the fatigue analysis for time and frequeucy domain has been performed by using the dynamic load spectrum of speed brake. In conclusion, it was proved that fatigue life of the horizontal fin was reduced by the influence of dynamic behavior.

Implementation of a Sensor to Detect the Foot-pushing Force for an Agricultural Transport-convenience Vehicle (농업용 이동편의장치를 위한 발로 미는 힘을 감지하는 센서 구현)

  • Seung-hee, Baek;Ik-hyun, Kwon;Cheong-worl, Kim
    • Journal of Sensor Science and Technology
    • /
    • v.31 no.6
    • /
    • pp.411-417
    • /
    • 2022
  • In this paper, we propose a sensor with a C-shaped load cell to detect force change when a person sitting on the chair in an electrical transport-convenience vehicle is pushing ground by both heels. The load cell built in the vehicle is mechanically deformed by the vertical force owing to the human weight and the horizontal force by ground-pushing feet. The deformation rate of the load cell and its distribution are simulated using finite element analysis. In the simulation, the applied loads are preset in the range of 10 kg - 100 kg with a step size of 10 kg, and the ground-pushing force by feet is increased to 40 N with a step size of 5 N with respect to each applied load level. The resistance change of the load cell was observed to be linear in simulation as well as in measurement. the maximum difference between simulation and measurement was 0.89 % when the strain gauge constant was 2.243. The constant has a large influence on the difference. The proposed sensor was fabricated by connecting an instrument amplifier and a microcontroller to a load cell and used to detect the force by ground-pushing feet. To detect foot driving, the reference signal was set to 130% of the load, and the duration of the sensor output signal exceeding the reference signal was set to 0.6 s. In a test of a vehicle built with the proposed sensor, the footpushing force by the worker could be successfully detected even when the worker was working.

Aerodynamic Load Analysis at Hub and Drive Train for 1MW HAWT Blade (1MW급 풍력 터빈 블레이드의 허브 및 드라이브 트레인 공력 하중 해석)

  • Cho Bong-Hyun;Lee Chang-Su;Choi Sung-Ok;Ryu Ki-Wahn
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.25-32
    • /
    • 2005
  • The aerodynamic loads at the blade hub and the drive shaft for 1MW horizontal axis wind turbine are calculated numerically. The geometric shape of the blade such as chord length and twist angle can be obtained fran the aerodynamic optimization procedure. Various airfoil data, that is thick airfoils at hub side and thin airfoils at tip side, are distributed along the spanwise direction of the rotor blade. Under the wind data fulfilling design load cases based on the IEC61400-1, all of the shear forces, bending moments at the hub and the low speed shaft of the drive train are obtained by using the FAST code. It shows that shear forces and bending moments have a periodic. trend. These oscillating aerodynamic loads will lead to the fatigue problem at both of the hub and drive train From the load analysis the maximum shear forces and bending moments are generated when wind turbine generator system operates in the case of the extreme speed wind condition.

  • PDF

Micro modelling of masonry walls by plane bar elements for detecting elastic behavior

  • Doven, Mahmud Sami;Kafkas, Ugur
    • Structural Engineering and Mechanics
    • /
    • v.62 no.5
    • /
    • pp.643-649
    • /
    • 2017
  • Masonry walls are amongst the oldest building systems. A large portion of the research on these structures focuses on the load-bearing walls. Numerical methods have been generally used in modelling load-bearing walls during recent years. In this context, macro and micro modelling techniques emerge as widely accepted techniques. Micro modelling is used to investigate the local behaviour of load-bearing walls in detail whereas macro modelling is used to investigate the general behaviour of masonry buildings. The main objective of this study is to investigate the elastic behaviour of the load- bearing walls in masonry buildings by using micro modelling technique. In order to do this the brick and mortar units of the masonry walls are modelled by the combination of plane truss elements and plane frame elements with no shear deformations. The model used in this study has fewer unknowns then the models encountered in the references. In this study the vertical frame elements have equivalent elasticity modulus and moment of inertia which are calculated by the developed software. Under in-plane static loads the elastic displacements of the masonry walls, which are encountered in literature, are calculated by the developed software, where brick units are modelled by plane frame elements, horizontal joints are modelled by vertical frame elements and vertical joints are modelled by horizontal plane truss elements. The calculated results are compatible with those given in the references.

Stability analysis of prestressed stayed steel columns with split-up crossarm systems

  • Li, Pengcheng;Li, Zhiqiang;Jia, Bin;Wang, Hao
    • Steel and Composite Structures
    • /
    • v.34 no.5
    • /
    • pp.769-782
    • /
    • 2020
  • A Prestressed stayed steel column is an efficient and lightweight way with regard to enhancing the stability behaviour of a compression column. In the past, researchers primarily concentrated on investigating the behaviour of stayed steel columns with horizontal crossarms. However, this article focuses on prestressed stayed steel columns with split-up crossarm system, in which the crossarms are aslant and rotational symmetrically arranged. A mathematical formula calculating the optimal pretension that corresponds to the maximum critical buckling load was established according to geometric analysis based on the small deformation assumption. It was demonstrated that critical buckling mode of this stayed column is different from the one with horizontal crossarms. The governing imperfection direction that should be adopted in the nonlinear buckling analysis was determined in this work. In addition, the effects of crossarm inclination, stay diameter, and crossarm length on the stability behaviour were investigated. An influencing factor denotes the ratio of the load carrying capacity of the prestressed stayed steel column to the Euler load of the main column was also obtained.

STRESS ANALYSIS OF VARIOUS ESTHETIC RESTORATIONS BY FINITE ELEMENT METHOD (유한 요소법을 이용한 수종 심미 수복물의 응력 분석)

  • Jo, Jin-Hee;Vang, Mong-Sook
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.29 no.2
    • /
    • pp.129-145
    • /
    • 1991
  • The purpose of this study was to analyze the stresses and displacements of various esthetic restorations and abutment teeth. The finite element models of central incisor were divided into four groups according to the types of restoration. Three load cases were applied; 1) 45 degrees on the incisal edge, 2) horizontal force on the labial surface, and 3) 26 degrees diagonally on the lingual surface. Material property, geometry, and load conditions of each model were inputed to the two dimensional finite element program and stresses and displacements were analyzed. Results were as follows; 1. In the cases of porcelain fused gold ann and porcelain laminate venner, stresses were equally distributed in supporting abutment tooth. 2. The metal coping of porcelain fused gold u and collarless porcelain fused gold crown functioned as a good stress distributor. 3. When the horizontal load applied, the highest tensile and compressive stresses were seen in the cervical margin of restoration and the dentin of the abutment tooth. 4. The highest displacement of restoration was seen when load was applied at an mee of 26 degrees diagonally in lingual surface of tooth in centric occlusion. 5. The influence of loading direction on the stresses and displacements in the restoration was greater than that of various design. 6. The possibility of fracture was highest in porcelain jacket crown.

  • PDF