• Title/Summary/Keyword: higher axial load

Search Result 238, Processing Time 0.027 seconds

Experimental study on axial compressive behavior of welded built-up CFT stub columns made by cold-formed sections with different welding lines

  • Naghipour, Morteza;Yousofizinsaz, Ghazaleh;Shariati, Mahdi
    • Steel and Composite Structures
    • /
    • v.34 no.3
    • /
    • pp.347-359
    • /
    • 2020
  • The objective of this study is to experimentally scrutinize the axial performance of built-up concrete filled steel tube (CFT) columns composed of steel plates. In this case, the main parameters cross section types, compressive strength of filled concrete, and the effect of welding lines. Welded built-up steel box columns are fabricated by connecting two pieces of cold-formed U-shaped or four pieces of L-shaped thin steel plates with continuous penetration groove welding line located at mid-depth of stub column section. Furthermore, traditional square steel box sections with no welding lines are investigated for the comparison of axial behavior between the generic and build-up cross sections. Accordingly, 20 stub columns with thickness and height of 2 and 300 mm have been manufactured. As a result, welding lines in built-up specimens act as stiffeners because have higher strength and thickness in comparison to the plates. Subsequently, by increasing the welding lines, the load bearing capacity of stub columns has been increased in comparison to the traditional series. Furthermore, for specimens with the same confinement steel tubes and concrete core, increment of B/t ratio has reduced the ductility and axial strength.

Evaluation of Local Allowable Wall Thickness of Thinned Pipe Subjected to Internal Pressure and Bending Moment (내압과 굽힘하중하에서 감육배관의 국부허용두께 평가)

  • Kim, Jin-Won;Park, Chi-Yong;Kim, Beom-Nyeon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.1
    • /
    • pp.81-88
    • /
    • 2001
  • This study proposed an analytical method to evaluate a local allowable wall thickness (LAWT) for locally thinned pipe subjected to internal pressure and bending moment. In this method, the stresses in the thinned region were calculated by finite element analysis and plastic collapse was applied as a failure criterion of thinned pipe. Using this method, LAWT for a simplified thinned pipe was evaluated with variation in axial extent of thinned area, and it was compared with allowable wall thickness provided by previous pipe wall thickness criteria. The results showed that the LAWT was lower, about 50%, than that calculated by construction code or ASME Code N-597, and it was higher, about 2 times, than that estimated by evaluation model based on pipe experiments. In addition, LAWT was decreased with increasing axial extent of thinned area and saturated with further increase in axial extent. And, the variation in LAWT with axial extent of thinned area depended on type of load, especially a magnitude of bending moment, considering in the evaluation.

Nonlinear Analysis of a Circular CFT Column Considering Confining Effects (구속 효과를 고려한 원형 CFT 기둥의 비선형 해석)

  • Han, Taek-Hee;Won, Deok-Hee;Yi, Gyu-Sei;Kang, Young-Jong
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.9 no.6
    • /
    • pp.1-9
    • /
    • 2009
  • An analysis program to predict the behavior of a concrete filled steel tube column (CFT) was developed. It considered confining effect, material nonlinearity, strain hardening of steel, and initial axial load. With the developed program, axial load-bending moment interaction analyses, moment-lateral displacement relation analyses, and lateral load-lateral displacement relation analyses were performed. For the verification of the developed program, analysis results were compared with the test results from the other researches. The verified results showed that the developed program predicted the behavior of the CFT column with agreeable accuracy. And they showed that it is necessary to consider the confining effect for the reasonable analysis of the CFT column. A simple parametric study was performed and it chose the strength of unconfined concrete and the thickness of a steel tube as the major parameters affecting the behavior of the CFT column. The parametric analysis results showed that the CFT column had higher strength and smaller ductility by increasing the strength of concrete. But the CFT column showed higher strength and larger ductility by increasing the thickness of the steel tube.

Stability of tow-steered curved panels with geometrical defects using higher order FSM

  • Fazilati, Jamshid
    • Steel and Composite Structures
    • /
    • v.28 no.1
    • /
    • pp.25-37
    • /
    • 2018
  • For the first time, the parametric instability characteristics of tow-steered variable stiffness composite laminated (VSCL) cylindrical panels is investigated using B-spline finite strip method (FSM). The panel is considered containing geometrical defects including cutout and delamination. The material properties are assumed to vary along the panel axial length of any lamina according to a linear fiber-orientation variation. A uniformly distributed inplane longitudinal loading varies harmoni-cally with time is considered. The instability load frequency regions corresponding to the assumed in-plane parametric load-ing is derived using the Bolotin's first order approximation through an energy approach. In order to demonstrate the capabili-ties of the developed formulation in predicting stability behavior of the thin-walled VSCL structures, some representative results are obtained and compared with those in the literature wherever available. It is shown that the B-spline FSM is a proper tool for extracting the stability boundaries of perforated delaminated VSCL panels.

Dynamic instability and free vibration behavior of three-layered soft-cored sandwich beams on nonlinear elastic foundations

  • Asgari, Gholamreza;Payganeh, Gholamhassan;Fard, Keramat Malekzadeh
    • Structural Engineering and Mechanics
    • /
    • v.72 no.4
    • /
    • pp.525-540
    • /
    • 2019
  • The purpose of the present work was to study the dynamic instability of a three-layered, symmetric sandwich beam subjected to a periodic axial load resting on nonlinear elastic foundation. A higher-order theory was used for analysis of sandwich beams with soft core on elastic foundations. In the higher-order theory, the Reddy's third-order theory was used for the face sheets and quadratic and cubic functions were assumed for transverse and in-plane displacements of the core, respectively. The elastic foundation was modeled as nonlinear's type. The dynamic instability regions and free vibration were investigated for simply supported conditions by Bolotin's method. The results showed that the responses of the dynamic instability of the system were influenced by the excitation frequency, the coefficients of foundation, the core thickness, the dynamic and static load factor. Comparison of the present results with the published results in the literature for the special case confirmed the accuracy of the proposed theory.

Experimental and analytical investigation on RC columns with distributed-steel bar

  • Ye, Mao;Pi, Yinpei;Ren, Min
    • Structural Engineering and Mechanics
    • /
    • v.47 no.6
    • /
    • pp.741-756
    • /
    • 2013
  • Distributed-Steel Bar Reinforced Concrete (DSBRC) columns, a new and innovative construction technique for composite steel and concrete material which can alleviate the difficulty in the arrangement of the stirrup in the column, were studied experimentally and analytically in this paper. In addition, an ordinary steel Reinforced Concrete (SRC) column was also tested for comparison purpose. The specimens were subjected to quasi-static load reversals to model the earthquake effect. The experimental results including the hysteresis curve, resistance recession, skeleton curves and ductility ratio of columns were obtained, which showed well resistant-seismic behavior for DSBRC column. Meanwhile a numerical three-dimensional nonlinear finite-element (FE) analysis on its mechanical behavior was also carried out. The numerically analyzed results were then compared to the experimental results for validation. The parametric studies and investigation about the effects of several critical factors on the seismic behavior of the DSBRC column were also conducted, which include axial compression ratios, steel ratio, concrete strength and yield strength of steel bar.

Statistical-based evaluation of design codes for circular concrete-filled steel tube columns

  • Li, Na;Lu, Yi-Yan;Li, Shan;Liang, Hong-Jun
    • Steel and Composite Structures
    • /
    • v.18 no.2
    • /
    • pp.519-546
    • /
    • 2015
  • This study addresses the load capacity prediction of circular concrete-filled steel tube (CFST) columns under axial compression using current design codes. Design methods given in the Chinese code CECS 28:2012 (2012), American code AISC 360-10 (2010) and EC4 (2004) are presented and described briefly. A wide range of experimental data of 353 CFST columns is used to evaluate the applicability of CECS 28:2012 in calculating the strength of circular CFST columns. AISC 360-10 and EC4 (2004) are also compared with the test results. The comparisons indicate that all three codes give conservative predictions for both short and long CFST columns. The effects of concrete strength, steel strength and diameter-to-thickness ratio on the accuracy of prediction according to CECS 28:2012 are discussed, which indicate a possibility of extending the limitations on the material strengths and diameter-to-thickness ratio to higher values. A revised equation for slenderness reduction factor in CECS 28:2012 is given.

Seismic performance of prefabricated reinforced concrete column-steel beam sub-assemblages

  • Bai, Juju;Li, Shengcai
    • Earthquakes and Structures
    • /
    • v.22 no.2
    • /
    • pp.203-218
    • /
    • 2022
  • In this paper, quasi-static tests were carried out on three prefabricated reinforced concrete column-steel beam (RCS) sub-assemblages with floor slabs and one comparison specimen without floor slab. The effects of axial compression and floor slab on the seismic performance were studied, and finite element simulations were conducted using ABAQUS. The results showed that the failure of prefabricated RCS sub-assemblages with floor occurred as a joint beam and column failure mode, while failure of sub-assemblages without floor occurred due to beam plastic hinge formation. Compared to the prefabricated RCS sub-assemblages without floor slab, the overall stiffness of the sub-assemblages with floor slab was between 19.2% and 45.4% higher, and the maximum load bearing capacity increased by 26.8%. However, the equivalent viscosity coefficient was essentially unchanged. When the axial compression ratio increased from 0.24 to 0.36, the hysteretic loops of the sub-assemblages with floor became fuller, and the load bearing capacity, ductility, and energy dissipation capacity increased by 12.1%, 12.9% and 8.9%, respectively. Also, the initial stiffness increased by 10.2%, but the stiffness degradation accelerated. The proportion of column drift caused by beam end plastic bending and column end bending changed from 35% and 46% to 47% and 36%, respectively. Comparative finite element analyses indicated that the numerical simulation outcomes agreed well with the experimental results.

An Experimental Study for the Structural Behavior of the Precast Prestressed Concrete Columns (프리캐스트 콘크리트 교각의 구조거동에 관한 실험적 연구)

  • Choi, Seung-Won;Shin, Hyun-Mok;Lee, Jae-Hoon;Oh, Byung-Hwan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.146-149
    • /
    • 2006
  • In many previous studies, a prestressed concrete column has a larger flexural strength, shear strength and restoring force than a RC column. Recently, a precast prestressed concrete column is rising up a very rational column structure in that a economic aspect. In a precast prestressed concrete column, it makes in a factory. So, it needs a small construction site and acquires a higher durability than a cast in place concrete column. Seven precast concrete columns were tested under a constant axial load and a cyclically reversed horizontal load to investigate the performance. It is designed with a hollow section and consisted of 4 segments. The main variables of the test were a amount of prestressed, a type of joints and a boding type of strands. The test results show that the performance of a precast prestressed concrete column; failure mode, maximum load, energy dissipation and stiffness degradation.

  • PDF

Buckling Behavior of a Square Tube Structure by Lateral Impact Load (사각 관 구조물의 충격에 의한 좌굴특성)

  • Yoon, K.H.;Song, K.N.;Kang, H.S.
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.812-818
    • /
    • 2001
  • The drop type impact test and finite element analysis are established for examining the buckling behavior of a square tube under the lateral impact load. Based on these results, the effects by the boundary conditions for supporting the structure are reviewed, which are as follows. One is pinned condition by screw; the other is fixed by welding. The critical impact force and acceleration by test are nearly same between two cases. However, the critical impact velocity of the pinned condition is higher than that of the fixed case. Therefore, the dynamic buckling behavior of a pinned structure is better than the fixed condition in view of critical impact velocity. These test and analysis results will be adaptable for predicting the dynamic structural integrity of a tube structure not only the axial impact event but the lateral impact event.

  • PDF