• Title/Summary/Keyword: high-temperature superconductor

Search Result 390, Processing Time 0.023 seconds

A study on the reduction of ac loss of YBCO coated conductor by a mechanical striation method (기계적으로 분할된 YBCO 선재의 교류손실 감소에 대한 연구)

  • Yoo, Yong-Su;Hong, Gye-Won;Lee, Hee-Gyoun
    • Progress in Superconductivity and Cryogenics
    • /
    • v.11 no.1
    • /
    • pp.9-15
    • /
    • 2009
  • High temperature superconductor (HTS) coated conductors has high hysteretic magnetization loss which is an obstacle for the AC applications of coated conductors. We propose a method to reduce the magnetization loss of the coated conductor. It is the mechanical striation method by load variety using office knife. The magnetization loss measured in the mechanical striated YBCO coated conductor without copper layer was compared with the loss generated by perpendicularly exposed external magnetic filed. The reduction in magnetization loss due to the mechanical striation is clearly shown at higher field and was dependent on the striation number. The mechanical striation method was proven to have additional advantages of a low cost and high fabrication process.

The Positive Bubble Effect and the Breakdown Characteristics in $SF_6$ and $LN_2$ ($SF_6$와 액체 질소의 절연파괴특성과 정기포현상)

  • Lee Kwang-Sik;Choi Eun-Hyuck;Park Kwang-Seo;Kim Jong-Whan;Lim Chang-Ho
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.8
    • /
    • pp.355-360
    • /
    • 2005
  • In this paper the experiments of breakdown characteristics by temperature change of $SF_6$ gas, $SF_6$ liquid ($LSF_6$) and $N_2$ liquid ($LN_2$) in model GIS(Gas Insulated Switchgear) were described. From the experiments results, the breakdown voltage of $SF_6$ increases with the drop of temperature and the increase of the inner pressure in model GIS. The ability of $LSF_6$ insulation is higher than high-pressurized $SF_6$ gas and $LN_2$. The breakdown characteristics of $LSF_6$ were produced by bubble formed evaporation of $LSF_6$ and bubble caused by high electric emission. It is considered in this paper that the results are fundamental data for electric insulation design of superconductor and cryogenic equipments machine교 which will be studied and developed in the future.

Analysis of normal Bone propagation characteristics in a high-temperature superconducting tape (고온 초전도체 테이프의 상전도 영역 전파 특성 해석)

  • 정신근;설승윤
    • Progress in Superconductivity and Cryogenics
    • /
    • v.3 no.1
    • /
    • pp.11-15
    • /
    • 2001
  • Stability of a Bi-2223/Ag tape was studied by using a numerical model considering the temperature distribution of cross-sectional area. The dynamic evolution of normal zone of a HTS tape can be shown by the developed two-dimensional Program using finite difference method. Two kinds of analyses are compared to quantify the critical disturbance energy for quenching HTS tapes. One is the length-thickness(x-r) side and the other is the length-width(x-z) side. For each case. the governing energy balance equations and corresponding boundary conditions are formulated. The results of analyses shows that the critical disturbance energies for each cases seem to be very close for considered Bi-2223/Ag tape .

  • PDF

The positive bubble effect in liquid $SF_6$ (액체 $SF_6$의 정기포현상(正氣泡現像))

  • Choi, Eun-Hyuck;Lee, Jae-Hyuck;Park, Kwang-Seo;Kim, Jong-Whan;Kim, Lee-Kook;Park, Won-Goo;Lee, Kwang-Sik
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.151-154
    • /
    • 2005
  • In this paper the experiments of insulation characteristics by temperature change of $SF_6$ gas and liquid $SF_6$ in model GIS(Gas Insulated Switchgear) were described. From this results, the breakdown voltage was increased with a drop of temperature and an increase of the inner pressure in model GIS. The ability of insulation in liquid $SF_6$ was higher than that of the highly pressurized $SF_6$ gas. A liquid $SF_6$ discharge characteristics was caused by bubble formed evaporation of liquid $SF_6$ and bubble caused by high electric emission. It is considered that these result are fundamental data for electric insulation design of superconductor and cryogenic application machinery which will be studied and developed in the future.

  • PDF

Numerical analysis of magnetization of HgBa$_2Ca_2Cu_3O_{8+{\delta}}$ superconductor (HgBa_2Ca_2Cu_3O_{8+{\delta}}$ 초전도체 자화의 수치적 해석)

  • Kim, Bong-Jun;Kim, Young-Cheol;Kim, Young-Jin;Back, Sang-Min
    • 한국초전도학회:학술대회논문집
    • /
    • v.9
    • /
    • pp.218-221
    • /
    • 1999
  • Magnetization measurements have been carried out on grain aligned Hg-1223 with the applied field parallel to the c-axis. The temperature dependence of the lower critical field H$_{cl}$(T) was determined by considering the effect of the surface barrier on the magnetization. H$_{cl}$(T) have been determined .from magnetic hysteresis loops within the framework of the modified Kim-Anderson critical-state model, where the surface barrier and the lower critical field are explicitly considered. At high temperature, H$_{cl}$(T) is identified as H$_p$(T). This results are agreed with the theory of Bean-Livinston surface barriers.

  • PDF

Optimal Design of Multi-Step Current Leads Using HTS Tapes (고온초전도 테이프를 이용한 다단 전류 도입선의 최적설계)

  • 김민수;나필선;설승윤
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2001.02a
    • /
    • pp.84-88
    • /
    • 2001
  • The optimum cross-sectional area Profile of gas-cooled high-temperature superconductor (HTS) current lead is analyzed to have minimum helium boil-off rate. The conventional constant area HTS lead has much higher helium consumption than the optimum HTS lead considered in this study. The optimum HTS lead has variable cross-sectional area to have constant safety factor. An analytical formula of optimum shape of lead and temperature profile are obtained. For multi-step HTS current leads, the optimum tape lengths and minimum heat dissipation rate are also formulated. The developed formulations are applied to the Bi-2223 material, and the differences between constant area, constant safety-factor, and multi-step current leads are discussed.

  • PDF

The stability analysis of high-temperature superconductor tape (고온 초전도체 테이프의 안정성 해석)

  • Jeong, S.G.;Seol, S.Y.
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.186-191
    • /
    • 2000
  • Stability of a Bi-2223/Ag tape was studied by using a numerical method. A numerical modeling has been developed to analyze the dynamic evolution of normal zone in a composite tape Bi-2223/Ag. In this paper, the stability of HTS tape is studied by considering the non-uniform temperature distribution in a cross-sectional area. The finite-difference method(FDM) is used to solve the two-dimensional heat conduction equation. Two kinds of analyses are compared to quantify the critical disturbance energy fur quenching HTS tapes. One is the length-thickness(x-y) side and the other is the length-width(x-z) side. The results of analyses shows that the critical disturbance energies for each cases seem to be very close for considered Bi-2223/Ag tape.

  • PDF

Characteristics of HTS tube fabricated by centrifugal forming process (원심성형법으로 제조한 고온초전도 튜브의 특성 분석)

  • Jang, Gun-Eik;Park, Yong-Min
    • 한국초전도학회:학술대회논문집
    • /
    • v.10
    • /
    • pp.211-215
    • /
    • 2000
  • Bi-2212 HTS tube was fabricated by CFP(Centrifugal Forming Process). Slury was prepared in the mixing ratio of 8:2 between powder and binder and ball-milled for 24 hrs. Slurry was initially charged into the rotating mold with 300${\sim}$450 rpm and heated at the temperature ranges of 840${\sim}$860$^{\circ}$C for partial melting to finally obtain a uniformly textured tube shape. It was observed the plate-like grains with more than 20 ${\mu}$m were well oriented along the rotating axis and the measured T$_c$ was around 67K. In this paper we will discuss and analyze the tube characteristics depending on many different processing parameters such as, powder composition, binder mixing ratio between powder and binder, motor speed, heating temperature and etc.

  • PDF

DC and AC current transport characteristics of HTS tapes with external magnetic field (외부자계 영향에 따른 HTS 선재의 직$\cdot$교류 통전 특성)

  • 임성우;최용선;최효상;황시돌;정영호
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.02a
    • /
    • pp.15-18
    • /
    • 2003
  • HTS(High Temperature Superconductor) tapes have dependence on critical characteristics such as electric, magnetic field and temperature. In order to confirm these effects, we examined the current transport characteristics of HTS tapes. First, after being fed DC and AC, the dependence of HTS tapes of 10cm on external magnetic field was investigated. On centeral region of HTS tape, about 1cm, external magnetic field was applied. Second, after applying DC of 50A to HTS tapes, we applied time variable magnetic field about 100mT and investigated the quench characteristics. Finally, AC, which is about 10 times of I$_{c}$, was applied to HTS tapes and over current characteristics were investigated. The data acquired in this study will be used as a source for the study of HTS cable conductor which is supposed to carry on.n.

  • PDF

The Optimum Shape of Taper HTS Current Lead Having Partial Current Sharing Region (일부 전류분류 영역을 갖는 테이퍼 형상 전류도입선의 최적 형상에 대한 연구)

  • 허광수;설승윤
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.185-189
    • /
    • 2003
  • The purpose of this study is to obtain the optimal operating condition of conduction cooled taper shape high-temperature superconductor (HTS) current lead operated in current sharing mode. In our previous study, we discovered that the optimal operating condition of constant cross-section area HTS current lead is in the current sharing state, and in optimal condition, the temperature gradient at warm end is not zero. The analysis result of taper HTS current lead is quiet similar to the constant area HTS current lead. The minimum dissipation of taper HTS current lead is not influenced by taper angle, however the optimal operation condition is varied with taper angle.

  • PDF