• 제목/요약/키워드: high-speed electrified railway

검색결과 12건 처리시간 0.024초

한국형 고속열차를 활용한 기존선 전철화 구간에서 고속열차 운행의 적합성 평가 (Test and evaluation on the suitability of operating high speed train in electrified conventional line through test run of HSR-350x)

  • 목진용;김영국;김기환;조민영
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 추계학술대회 논문집
    • /
    • pp.229-235
    • /
    • 2007
  • The KTX, which have opened the revenue service in April 2004, is operating in Kyoung-Bu high-speed line and electrified conventional Ho-Nam line, and the more the electrification are enlarged, the more the requirement of operating of high speed train would be increased. In this paper, the result of test run and evaluation on the suitability of operating high speed train in electrified conventional line between Dae-jeon and East Dae-gu was reviewed. Evaluation and analysis was executed in specific categories, such as operation & running performance of the train considering vibration characteristics based on UIC 518, ride comfort and current collection, and response sensitivity of ATS device for signalling from track facility. The result of this running test was evaluated and considered as a good practice for revenue operation of high speed train in electrified conventional line between Dae-jeon and Dae-gu.

  • PDF

고속전철에 의한 통신 선로에서의 유도전압 분석 (Induced Voltages on Telecommunication Lines Due to AC High-Speed Electrified Railway System)

  • 오호석;강성용;윤주영;김학철
    • 한국전자파학회논문지
    • /
    • 제20권9호
    • /
    • pp.983-988
    • /
    • 2009
  • 본 논문에서는 고속전철 운행에 따라 인접 통신 선로에서 발생하는 유도전압을 국내 고시에 제시된 측정 회로에 따라 측정하고 유도전압의 특징을 분석하였다. 고속전철 선로와 2 km 병행하는 2개 루트의 시험용 통신선로를 구성하여 이격 거리, 병행 거리에 따른 유도전압을 측정 및 분석하고, 측정 회선 단말 접지 위치의 레일과의 거리에 따라 측정값에 대한 영향 여부를 검토하였다. 또한 1일간 시간에 따른 변화, 요일별 변화 등을 분석하였으며, 유도전압에 포함되어 있는 고조파 성분을 확인하였다. 이론과 같이 이격 거리에 따른 유도전압의 차이를 보였으며, 단말의 접지 위치는 측정값에 큰 영향을 주지 않음을 확인하였다. 또한 특정 시간대 및 특정 날짜에 상대적으로 큰 유도전압이 나타남을 확인하였다.

고속전철에 의한 통신선로 전력유도 현상에 관한 고찰 (A Study on the Induced Voltages on Subscriber Telecommunication Lines from High-Speed Electrified Railway Line)

  • 오호석;강성용;윤주영;김학철;최경
    • 대한전자공학회논문지TC
    • /
    • 제45권10호
    • /
    • pp.71-79
    • /
    • 2008
  • 본 논문은 고속 전기철도 시설로 인해 가입자 통신선로에서 발생하는 전력유도에 대한 현상과 관련 규정 및 유도전압 측정 결과를 분석한 것이다. 전력유도 현상의 명확한 이해를 돕기 위하여 이론적 배경을 제시하였고, 국내 법규에서 이상시유도위험전압, 상시유도위험종전압, 기기오동작유도종전압, 잡음전압 등으로 구분되는 유도전압 중에서 공통모드 전압에 해당하는 상시유도위험종전압과 잡음평형도 평가에 필요한 선대지잡음전압 및 차동모드전압인 선간잡음전압을 우리나라 고시 측정방법에 따라 측정하였다. 측정을 위해 이격거리가 각각 약 20 m와 300 m인 2 km 길이의 통신선로를 설치하여 실험하였으며 측정된 유도전압의 변화 및 파형 특성 등을 비교, 분석함으로써 고속전철에 의한 통신선로 전력유도 현상을 고찰하고 현행 측정방법의 타당성을 검토하였다.

Closed Type 절연구분장치 적용에 관한 연구 (An Application Study of the Closed Type Section Insulators to the High Speed Catenary System)

  • 최규형;이기원
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2002년도 춘계학술대회 논문집
    • /
    • pp.498-502
    • /
    • 2002
  • Section insulators are indispensible devices for the electric railways, which divide electrical connections between the trolley lines without losing mechanical connections, and this means that they should have both good electrical insulation performance and mechanical performance for pantograph interaction. This paper reviews some technical aspects of the several type section insulators and makes analysis of difficulties during operation. The closed type section insulators are proposed for newly electrified railways, because they have good mechanical and electrical performances for high speed trains up to 200[km/H]. Technical specifications of closed-type section insulators based on survey of the advanced technologies are provided, and also the neutral section configuration method which might be the best solution for newly electrified railways in Korea of 200km/H speed.

  • PDF

전기철도시스템의 접지 유형에 따른 귀선 전류 비교 (Comparison of Return current by the Earth type in the Electrical railway system)

  • 이길노;김용규;백종현;유창근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.53-55
    • /
    • 2005
  • In electrical railway system, power supplied to electrical locomotive by catenary is returned to sub-station on track. The current returned to sub-station on track is return current, which is an essential factor for the safety of the wayside electrical equipment and maintenance staff. Therefore, earth system acts an important role to protect wayside electrical equipment and maintenance staff against return current. In general, individual earth system protects partially the electrical railway system, but common earth system does the whole electrical railway system and minimizes the flow of return current. In this paper, we are compared the effect of return current according to earth type by actual measurement in existing electrical railway system. The measurement was conducted at Shinchungju sub~station in high speed trains, and Guro sub-station, which is electrified section in classical line.

  • PDF

고속철도에 의한 통신회선 잡음전압 발생 원인 고찰 (A Study on Causes Generating Induced Noise Voltage on Telecommunications Cables Near to High-speed Rails)

  • 여상근;박찬원;김정태
    • 한국철도학회논문집
    • /
    • 제11권3호
    • /
    • pp.248-256
    • /
    • 2008
  • 본 논문은 고속철도 주변 통신회선에 발생되는 잡음전압의 실체 파악을 통해 전력유도잡음전압이 발생하지 않는 것을 증명하였으며, 국내통신회사 및 전파연구소에서 사용하고 있는 평형도 측정에서의 문제점과 계측 오류를 규명하며 표준 측정회로와 측정 조건을 ITU-T 국제 기준에 맞도록 개정할 것을 제안한다.

고속철도의 급전계통 구성에 따른 고조파 확대율 비교 검토 (The comparison and investigation of harmonic magnification according to power supply schemes in high speed railway)

  • 이장무;오광해;창상훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.1402-1404
    • /
    • 2000
  • The electrified railway has various power supply schemes. Although the identical trains are operated in same condition and the impedance of track are equal, the genealogy impedance of track is changed according to composition method of feeding scheme. So, the harmonic current flowing into the railway substation are greatly unlike. For simulation of harmonic magnification flowing into the railway substation according to feeding scheme, we propose 6-port network analysis method based on 4-port network, find 6-port equivalent model of each circuit component, and compare and investigate harmonic magnification in the case of parallel post and normal feeding scheme.

  • PDF

대전북(대전 조차장-대전역) 고속전철 연계 운행 구간의 운전시격 분석 (Headway Analysis in Daejeon Nord section(Daejeon shunting yard-Daejeon station) which high speed train and conventional trains will be run)

  • 김용규;김종기;유창근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 B
    • /
    • pp.810-813
    • /
    • 2003
  • The present headway on KNR(Korea National Railway) lines varies from 6 to 10 minutes depending on the each line and by the operation of High Speed line in 2004, the bottleneck would be expected within a few sections such as Daejeon-Daejeon shunting yard which will be the common mute between KTX(Korea Train Express) and conventional trains. Therefore, KNR would like to reduce the headway of the all lines by 4 minutes with the implementation of ERTMS/ETCS on-board system. Where ETCS(European Train Control system), the subsystem of ERTMS, is Automatic Train Protection system for safety train running. This study will be analyze expected braking distance and running time depending on characteristics of conventional passenger and freight trains and high speed train will be operated within electrified conventional line for comparing the headways of ATS(Automatic Train Stop) system and ETRMS/ETCS system within the Daejeon-Daejeon shunting yard section.

  • PDF

폐색 구간 길이에 따른 동대구-부산간 운전 시격 연구 (A Study on the Headway bewteen Dongdaegu and Busan by block system length)

  • 김용규;양도철;김종기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.1292-1294
    • /
    • 2002
  • In this study, the block section length of the given area has been analyzed to improve the headway which caused by the mixed operation of high speed trains and normal trains on the electrified railway of Dongdaegu to Busan. After establishing the average length of block section and the adjustable average length of block section of Dongdaegu to Busan, it is possible to perform the headway simulation regarding the signal system based on the established length. Although high speed trains as well as low speed trains including freight trains operate together, the experimental results indicate that the modification of the block section length shows the possibility of the improvement of headway.

  • PDF

전기철도시스템에서 궤도회로 측면의 귀선전류 고조파 분석 (Analysis of Harmonic Frequency for Return Current on the Track Circuit in Electrical Railway System)

  • 백종현
    • 전기학회논문지
    • /
    • 제61권5호
    • /
    • pp.698-704
    • /
    • 2012
  • Electric power used in electrical vehicles flows into the substation through the feedback circuit, track circuit. Due to these power conversion equipments in electrical railroads, return current contains harmonics, and it should not affect other communication lines. In this paper, based on the return currents, we measured harmonics and analyzed an influence in railway equipments due to the harmonics. For analysis, we utilize the measured values of return currents measured in track circuits, and predictive values of those compared to the earth methods between the existing electrified sections. Applying the regulations used for Gyeongbu HSL(High Speed Line), the results of measured harmonics have found to be acceptable.