• Title/Summary/Keyword: high-frequency core

검색결과 479건 처리시간 0.03초

Considerations of Buck+Half Bridge Converter characteristics (벅+하프 브리지 컨버터의 효율 특성 고찰)

  • Park, Nam-Jin;Kim, Chang-Sun;Kim, Tea-Sic;Im, Bum-Sun;Woo, Seung-Hun
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.1229-1231
    • /
    • 2003
  • We considered of the efficiency for the Buck+Half bridge converter, this converter has advantages of applications for a low output voltage, a high output current and a wide input voltage. Developed the Buck+Half Bridge converter ratings are of $36{\sim}72V$ input and 3.3V/30A output. In Half Bridge converter the $86{\sim}96.4%$ of the efficiency is measured at 100kHz switching frequency with PQI core. In the case of synchronized the Buck+Half Bridge converter, the measured efficiency is higher than the unsynchronized converter. In the synchronized Buck+Half Bridge, the maximum efficiency is up to 92.3% with PQI core at 100kHz, 7A output.

  • PDF

Identifying Young AGNs using the Korean VLBI Network

  • Jeong, Yongjin;Sohn, Bong Won;Chung, Aeree
    • The Bulletin of The Korean Astronomical Society
    • /
    • 제40권1호
    • /
    • pp.42.2-42.2
    • /
    • 2015
  • High frequency peakers (HFPs) are promising candidates for young active galactic nuclei (AGNs). Their small physical scale (< 1 kpc) and radio spectrum peaked at high frequency (> 5 GHz) are suggestive that it has been only about $10^2-10^3$ years since a central massive black hole in their host galaxies was launched. Until recently however, long-term monitoring radio observations at frequencies which are high enough to cover the true peak of HFP candidates were rare. Therefore, previous HFP samples are often contaminated by blazars, which are highly variable, hence may show a similar radio spectrum as HFPs depending on the observational epoch. In this work, we challenge to identify genuine young AGNs by monitoring HFP candidates at high radio frequencies. We performed single-dish monitoring of 19 candidates in 18 epochs over 2.5 years at 22 and 43 GHz using the Korean VLBI Network (KVN). Also, using KaVA, a combined array of the KVN and the VERA in Japan, we carried out 22 GHz VLBI observations of two HFPs and one blazar selected from our sample in order to compare their parsec scale (milli-arcsecond scale) morphology. HFPs are expected to have double/triple features, so called compact symmetric objects, which are scaled-down versions of extended radio galaxies, while blazars typically show core-jet morphology. We discuss the properties of AGNs at their very early evolutionary stage based on the results of the KVN and KaVA observations.

  • PDF

Imaging Characteristics of Plastic Scintillating Fiber Screens for Digital Mammography

  • Choi, Won-Young;Walker, James K.;Jing, Zhenxue
    • Journal of Biomedical Engineering Research
    • /
    • 제17권2호
    • /
    • pp.165-172
    • /
    • 1996
  • A scanning slot digital mammography system Luing a plastic scintillating fiber screen (SFS) is currently being developed To improve the x-ray interaction efficiency and absorption efficiency of an SFS, high Z elements can be added into the scintillating fiber core. In this paper, we investigated theoretically the zero spatial frequency detective quantum efficiency, DQE(0), and modulation transfer function, MTF(f), of three 2 cm thick SFSs made of polystyrene, polystyrene loaded with 5% by weight of lead, and polystyrene Loaded with 10% by weight of tin scintillating fibers. X-ray interaction efficiency, scintillating light intensity distributions and line spread functions were generated using Monte Carlo simulation. DQE(0) and MTF(f) were computed for x-ray energies ranging from 15 to 50 keV. Loading high Z elements into the SFS markedly increased the DQE(0). For x-ray energies used for mammovaphy, DQE(0) values of both high Z element loaded SFSs are about a factor of three higher than the DQE(0) of an Min-R screen. At mammographic x-ray energies, MTF(f) values of all three SFSs are Venter than 50% at 25 Ip/mm spatial frequency, and were found to be dominated by the 20 um individual scintillating fiber diameter used The results show that both hiP DQE(0) and spatial resolution can be achieved with the high Z element loaded SFSs, which make these SFSs attractive for use in a scanning slot detector for digital mammography.

  • PDF

An InGaP/GaAs HBT Monolithic VCDRO with Wide Tuning Range and Low Phase Noise

  • Lee Jae-Young;Shrestha Bhanu;Lee Jeiyoung;Kennedy Gary P.;Kim Nam-Young
    • Journal of electromagnetic engineering and science
    • /
    • 제5권1호
    • /
    • pp.8-13
    • /
    • 2005
  • The InGaP/GaAs hetero-junction bipolar transistor(HBT) monolithic voltage-controlled dielectric resonator oscillator(VCDRO) is first demonstrated for a Ku-band low noise block down-converter(LNB) system. The on-chip voltage control oscillator core employing base-collector(B-C) junction diodes is proposed for simpler frequency tuning and easy fabrication instead of the general off-chip varactor diodes. The fabricated VCDRO achieves a high output power of 6.45 to 5.31 dBm and a wide frequency tuning range of ]65 MHz( 1.53 $\%$) with a low phase noise of below -95dBc/Hz at 100 kHz offset and -115 dBc/Hz at ] MHz offset. A]so, the InGaP/GaAs HBT monolithic DRO with the same topology as the proposed VCDRO is fabricated to verify that the intrinsic low l/f noise of the HBT and the high Q of the DR contribute to the low phase noise performance. The fabricated DRO exhibits an output power of 1.33 dBm, and an extremely low phase noise of -109 dBc/Hz at 100 kHz and -131 dBc/Hz at ] MHz offset from the 10.75 GHz oscillation frequency.

Sound Absorption Rate and Sound Transmission Loss of CLT Wall Panels Composed of Larch Square Timber Core and Plywood Cross Band

  • Kang, Chun Won;Jang, Sang Sik;Kang, Ho Yang;Li, Chengyuan
    • Journal of the Korean Wood Science and Technology
    • /
    • 제47권1호
    • /
    • pp.33-39
    • /
    • 2019
  • The square timbers of larch having cross section of $90mm{\times}90mm$ were glued laterally to be formed $1,200mm{\times}2,400mm$ panels which were used as cores for CLT wall panels. Then, structural plywood panels having size of $1,200mm{\times}2,400mm$ were used as cross band covering the small square timber cores to manufacture CLT wall panels. The sound absorption rate of CLT wall panels and polyester board attached CLT wall panels were investigated. The mean sound absorption coefficients of the former and the latter in the frequency range of 100-6400 Hz were 0.21 and 0.74, respectively. The noise reduction coefficients (NRC) of those were 0.21 and 0.40, respectively. Also, the mean sound transmission loss of CLT wood panel in the frequency range of 50-1600 Hz was 45.12 dB and that value at the frequency of 500 Hz was 42.49 dB. It was suggested that the polyester board attached CLT wall panels could be used as housing wall because of its high sound absorption rate and high sound transmission loss.

A Study on the Fabrication and High Frequency Characteristics of Close type Magnetic Planar Inductor (폐자로형 평면 인덕터의 제조 및 고주파 특성에 관한 연구)

  • 이창호;신동훈;남승의;김형준
    • Journal of the Korean Magnetics Society
    • /
    • 제8권4호
    • /
    • pp.241-248
    • /
    • 1998
  • In accordance with tendency to miniaturization and high frequency operation of electronic products, extensive efforts of miniaturizing magnetic devices such as inductors, transformers and magnetic sensors are being made. In order to study on fabrication and characteristic of micro-magnetic devices, we carried out two sets of experiments. One is to develop a magnetic film that is suitable for high frequency operation, and the other is to develop the fabrication processes for realizing the micro-coil with meander shape. Magnetic films were composed of FeTa(N,C) fabricated by DC magnetron sputtering system. Their microstructures were nanocrystalline structure and magnetic properties showed Bs:13~17 kG, Hc:0.1~0.2 Oe and $\mu$':2000~4000. Cu coil pattern fabricated by selective electroplating process showed good electrical conductivity. In the case of air core inductors, inductance (L) of 50 nH, resonance frequency $(f_R)$ of 700 MHz, and quality factor (Q) of 30 at 200 MHz could be obtained. In the case of close type magnetic inductors, inductance (L) of 150 nH, resonance frequency $(f_R)$ of 100 MHz, and quality factor (Q) of 4 at 10~30 MHz could be obtained.

  • PDF

MEMS-BASED MICRO FLUXGATE SENSOR USING SOLENOID EXCITATION AND PICK-UP COILS (MEMS 공정 제작방법에 의한 솔레노이드형 여자 코일과 검출코일을 사용한 마이크로 플럭스게이트 센서)

  • 나경원;박해석;심동식;최원열;황준식;최상인
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집
    • /
    • pp.172-176
    • /
    • 2002
  • This paper describes a MEMS-based micro-fluxgate magnetic sensing element using Ni$\_$0.8/Fe$\_$0.2/ film formed by electroplating. The micro-fluxgate magnetic sensor composed of a thin film magnetic core and micro-structured solenoids for the pick-up and the excitation coils, is developed by using MEMS technologies in order to take advantage of low-cost, small size and lower power consumption in the fabrication. A copper with 20um width and 3um thickness is electroplated on Cr(300${\AA}$)/Au(1500${\AA}$) films for the pick-up(42turn) and the excitation(24turn) coils. In order to improve the sensitivity of the sensing element, we designed the magnetic core into a rectangular-ring shape to reduce the magnetic flux leakage. An electroplated permalloy film with the thickness of 3 $\mu\textrm{m}$ is obtained under 2000Gauss to induce magnetic anisotropy. The magnetic core has the high DC effective permeability of ∼1,100 and coercive field of -0.1Oe. The fabricated sensing element using rectangular-ring shaped magnetic film has the sensitivity of about 150V/T at the excitation frequency of 2MHz and the excitation voltage of 4.4Vp-p. The power consumption is estimated to be 50mW.

  • PDF

Vibration Analysis of Transformer DC bias Caused by HVDC based on EMD Reconstruction

  • Liu, Xingmou;Yang, Yongming;Huang, Yichen
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권2호
    • /
    • pp.781-789
    • /
    • 2018
  • This paper proposes a new approach utilizing empirical mode decomposition (EMD) reconstruction to process vibration signals of a transformer under DC bias caused by high voltage direction transmission (HVDC), which is the potential cause of additional vibration and noise from transformer. Firstly, the Calculation Method is presented and a 3D model of transformer is simulated to analyze transformer deformation characteristic and the result indicate the main vibration is produced along axial direction of three core limbs. Vibration test system has been built and test points on the core and shell of transformer have been measured. Then, the signal reconstruction method for transformer vibration based on EMD is proposed. Through the EMD decomposition, the corrupted noise can be selectively reconstructed by the certain frequency IMFs and better vibration signals of transformer have been obtained. After EMD reconstruction, the vibrations are compared between transformer in normal work and with DC bias. When DC bias occurs, odd harmonics, vibration of core and shell, behave as a nonlinear increase and the even harmonics keep unchanged with DC current. Experiment results are provided to collaborate our theoretical analysis and to illustrate the effectiveness of the proposed EMD method.

MEMS-based Micro Fluxgate Sensor Using Solenoid Excitation and Pick-up Coils (MEMS 공정 제작방법에 의한 솔레노이드형 여자 코일과 검출코일을 사용한 마이크로 플럭스게이트 센서)

  • 나경원;박해석;심동식;최원열;황준식;최상언
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • 제16권2호
    • /
    • pp.120-124
    • /
    • 2003
  • This paper describes a MEMS-based micro-fluxgate magnetic sensing element using Ni$\_$0.8/Fe$\_$0.2/ film formed by electroplating. The micro-fluxgate magnetic sensor composed of a thin film magnetic core and micro-structure solenoids for the pick-up and the excitation coils, is developed by using MEMS technologies in order to take advantage of low-cost, small size and lower power consumption in the fabrication. A copper with 20${\mu}$m width and 3${\mu}$m thickness is electroplated on Cr (300${\AA}$) / Au (1500${\AA}$) films for the pick-up (42turn) and the excitation (24turn) coils. In order to improve the sensitivity of the sensing element, we designed the magnetic core into a rectangular-ring shape to reduce the magnetic flux leakage. An electroplated permalloy film with the thickness of 3${\mu}$m is obtained under 2000 gauss to induce magnetic anisotropy. The magnetic core has the high DC effective permeability of ~1,100 and coercive field of ~0.1 Oe. The fabricated sensing element using rectangular-ring shaped magnetic film has the sensitivity of about 150 V/T at the excitation frequency of 2 MHz and the excitation voltage of 4.4 V$\_$p p/. The power consumption is estimated to be 50mW.