• 제목/요약/키워드: high tower

검색결과 552건 처리시간 0.026초

풍하중이 작용하는 고용량 송전철탑의 해석을 통한 응력 분포 고찰 (A Study for Stress Distribution of the High-voltage Transmission Tower Under Wind Forces)

  • 장진원;김승준;박종섭;강영종
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2007년도 정기총회 및 학술발표대회
    • /
    • pp.75-78
    • /
    • 2007
  • The structural methodology in designing a transmission tower have been performed to assume a simple truss behavior. But there're quite differences between a simple truss behavior and a real one. A suitable explanation for a structural stability can be expressed as a semi-rigid connection instead of the assumed hinged connection. This study proposes an alternative structural analysis modelling strategy for the transmission tower design. Proposed element models are truss element model, beam element model, and combined beam-truss element model. The static finite element analysis shows that there's a moment distribution between a mainpost member and the other bracing member.

  • PDF

초고압 송전철탑 구조성능시험에 관한 연구 (A Study on the Full Scale Structural Test of High Voltage Electric Transmission Tower)

  • 김우범
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1994년도 봄 학술발표회 논문집
    • /
    • pp.171-180
    • /
    • 1994
  • Full scale structural test of 765kv electric transmission tower was performed to measure the stresses and displacement of towers under the design loadings, and the results were compared with analytical results based on three dimensional frame analysis. Also, the actual ultimate strength of the tower was measured through destructive test. Especially, to predict the behavior and failure of the connection of tubular member, finite element analysis was performed and compression test for the segments of tubular member were carried out. Valuable information for the overall and local behavior of the tower was obtained and reliability of current analytical method was confirmed.

  • PDF

탑상형 아파트의 여름철 통풍성능 개선에 대한 연구 (A Study on the Improvement of Cross Ventilation Efficiency in a Tower Type Apartment in Summer Season)

  • 조근제;장현재
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.299-304
    • /
    • 2012
  • In terms of plane structure, tower-type apartments have several disadvantages compared to flat-type apartments in the aspect of ventilation rate. Such disadvantages may not produce good indoor cooling effects with natural ventilation inside the heated apartments in hot summer days, so they may cause high energy consumption by an increase in cooling load. The purpose of this study is to investigate ways for improving the indoor thermal environment of tower-type apartments in summer by conducting quantitative evaluations of the airflow distribution in households.

  • PDF

Brief description of the Design and Construction of the Burj Dubai Project, Dubai, UAE.

  • Abdelrazaq Ahmad K.
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(I)
    • /
    • pp.9-14
    • /
    • 2005
  • The Burj Dubai Project will be the tallest structure ever built by man; when completed the tower will be more than 700 meter tall and more than 160 floors. The early integration of aerodynamic shaping and wind engineering considerations played a major role in the architectural massing and design of this residential tower, where mitigating and taming the dynamic wind effects was one of the most important design criteria. This paper presents a brief overview of the structural system development and considerations of the tower and discusses the construction planning of the key structural components of the tower.

  • PDF

멀티패스 밀폐식 냉각탑의 성능특성에 대한 수치적 연구 (A Numerical Study on Performance Characteristics of a Closed Circuit Cooling Tower with Multi Paths)

  • 김은필
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제32권4호
    • /
    • pp.528-533
    • /
    • 2008
  • A closed circuit cooling tower having high temperature of cooling water and small water flow rate is investigated. To study the characteristics of the heat transfer of heat exchanges in a cooling tower with multi paths a numerical method is used. The results show that the staggered tube arrangements in a bank show better performance than aligned ones for temperature variation with various outer diameters of tube bundles. In case of one pass, the 15.88 mm tube case shows about 9% better performance than the 25.4 mm tube case. In two paths, the tube outside diameter of 15.88 mm show about 14.4% better results than the 25.4 mm diameter case.

충전재 형상에 따른 냉각탑 성능비교에 관한 연구 (Comparison of performance of cooling tower with various shape of packings)

  • 이강현;최우영;이재헌;소헌영
    • 설비공학논문집
    • /
    • 제10권3호
    • /
    • pp.358-367
    • /
    • 1998
  • Since the performance of cooling tower is strongly dependent on the thermal performance of the packing, the evaluations of heat transfer rate and fan power from various packing have attracted intense interest. In the present study, two new packings have been devised and their performances have been compared with those of two existing packings to find better shape characteristic. It is found that one of the existing packings, which showed high heat transfer rate and medium fan power due to zig -zag flow passages and highly irregular surfaces, should be adapted.

  • PDF

해외에너지자원획득과 소요자금 확보를 위한 통합 컨트롤 타워 설치 필요성에 관한 연구 (Necessity to Install Integrated Control Tower for Overseas Energy Resources Acquisition and Securing Funds)

  • 강지광;이재헌
    • 플랜트 저널
    • /
    • 제6권3호
    • /
    • pp.40-45
    • /
    • 2010
  • Necessity to install control towers has been studied to acquire overseas energy resources and to secure funds. At present, domestic energy companies do business independently. Institutions which support plant EPC companies as partners of package deal are separated. This causes the low records at package deal for overseas resources acquisition. Except UK and USA, nations which have major companies developed overseas energy resources early by promoting a large national company. Consequently, they currently have good records. This study suggests the necessities to install integrated control tower for overseas energy resources acquisition and securing funds and the following are the ways ; 1) promote a large national company by consolidation of separate energy companies, 2) install plant EPC promotion department which support private plant EPC companies, 3) make a integrated control tower in high level government office to connect between a large national company and plant EPC promotion department.

  • PDF

Structural monitoring of a wind turbine steel tower - Part I: system description and calibration

  • Rebelo, C.;Veljkovic, M.;da Silva, L. Simoes;Simoes, R.;Henriques, J.
    • Wind and Structures
    • /
    • 제15권4호
    • /
    • pp.285-299
    • /
    • 2012
  • This paper describes the development and calibration of a structural monitoring system installed in a 80 meters high steel wind tower supporting a 2.1 MW turbine Wind Class III IEC2a erected in the central part of Portugal. The several signals are measured at four different levels and include accelerations, strains on the tower wall and inside the connection bolts, inclinations and temperature. In order to correlate measurements with the wind velocity and direction and with the turbine operational parameters the corresponding signals are obtained directly from the turbine own monitoring system and are incorporated in the developed system. Results from the system calibration, the structural identification and the initial period of data acquisition are presented in this paper.

Wind-induced response of a twin-tower structure

  • Xie, Jiming;Irwin, Peter A.
    • Wind and Structures
    • /
    • 제4권6호
    • /
    • pp.495-504
    • /
    • 2001
  • With a newly developed multi-force-balance system(MFB), a twin-tower structure was studied for its wind-induced responses. The MFB system allowed the twin towers, which were linked structurally, to be treated as a single structural system with its corresponding modes of vibration involving coupled motions of the two towers. The towers were also studied using a more conventional force balance approach in which each tower was treated as an isolated structure, i.e., as though no structural link existed. Comparison of the results reveals how the wind loads between the towers are redistributed through the structural links and the modal couplings. The results suggest that although the structural links usually have beneficial impacts on wind-induced response, they may also play a negative role if the frequency ratios of pair modes are near 1.0.

탑상형 초고층 주거건축의 단위평면 특성에 관한 연구 - 외기접합 면수별 공간구성 특성을 중심으로 - (A Study on the Characteristics of an Unit Plan for a Tower Type Super-High-Rise-Residence)

  • 이용광
    • 한국실내디자인학회논문집
    • /
    • 제13권5호
    • /
    • pp.90-97
    • /
    • 2004
  • The purpose of this study is to grasp the spatial characteristic of the unit plan for a Super-High-Rise-Residence. This study is focused on the open air contact sides for a tower type Super-High-Rise-Residence. A tower type Super-High-Rise-Residence which has open air contacts from 1 to 3.5 sides differed in spatial characteristics of the unit plan for other apartment units. The current study analyzed 188 unit plans for the size of 40 pyong or larger in Seoul and the metropolitan areas which have been built since 1990. Open air contact side was classified as under 2 sides, 2 sides, and over 2 sides. The unit plan which belong to each open air contact side was Investigated according to the location of public area, the relationship between livingroom and master bedroom, and a method of entry to the master bedroom. The results of this study are as follow: According to increase open air contact sides is changed the location of public area in unit plan from an typical arrangement to various arrangement. Also the relationship between livingroom and master bedroom becomes loose and in a method of entry to the master bedroom increase an indirect approach through other room.