• 제목/요약/키워드: high temperature high pressure

Search Result 4,161, Processing Time 0.031 seconds

Thermal Design Analysis of Triple-Pressure Heat Recovery Steam Generator and Steam Turbine Systems (삼중압 열회수 증기발생기와 중기터빈 시스템의 열설계 해석)

  • Kim, Dong-Seop;Lee, Bong-Ryeol;No, Seung-Tak;Sin, Heung-Tae;Jeon, Yong-Jun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.3
    • /
    • pp.507-514
    • /
    • 2002
  • A computation routine, capable of performing thermal design analysis of the triple-pressure bottoming system (heat recovery steam generator and steam turbine) of combined cycle power plants, is developed. It is based on thermal analysis of the heat recovery steam generator and estimation of its size and steam turbine power. It can be applied to various parametric analyses including optimized design calculation. This paper presents analysis results for the effects on the design performance of heat exchanger arrangements at intermediate and high temperature parts as well as steam pressures. Also examined is the effect of steam sources for deaeration on design performance.

Comparative Study on the Protective Functions of Clothes (의복의 보호론에 관한 이론적 고찰)

  • Lim Sook Ja
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.9 no.3
    • /
    • pp.71-78
    • /
    • 1985
  • This research is designed to systemize the protection theory as well as to supplement the missing theory by organizing various studies on the protective functions of celothes by domestic and foreign scholers of clothing. Human environments is classified two standpoints : (1) Physical environments, and (2) man built psychological environments including socio-physical environments, socio-biological environments, behavioral environments, socio-psychological environments and institution environments. Clothes acting as a physical protection might be of (1) extreme air temperature: Parka; (2) high relative humidity: raincoat; (3) air movement: windbreaker; (4) radiation: space suit; (5) atmospheric pressure: deep sea diver suit; (6) mechanical agent: bullet proof vest; (7) physical agent: (8) chemical agent: (9) biological agent: surgeon's gown, cap, and mask. Also dresses act to support the body comfort, health and the well-being; corset for bad back patient, wrist band for people with weak wrist, bottom half of pressure suit for people with low blood pressure. Clothes acting as a psychological protection might be of (1) influence of magic and of spirits: (2) moral danger; (3) the general unfriendliness of the world as a whole; a reassurance against the lack of love. Clothes should provide the maximum of satisfaction in accordance with the full recognition of reality. The reality should aim at the formulation of general laws concerning the most pleasing forms, colors, and styles to suit. The complex physiological anatomical and psychological aspects of individual personalities.

  • PDF

VERIFICATION OF COSMOS CODE USING IN-PILE DATA OF RE-INSTRUMENTED MOX FUELS

  • Lee, Byung-Ho;Koo, Yang-Hyun;Cheon, Jin-Sik;Oh, Je-Yong;Joo, Hyung-Kook;Sohn, Dong-Seong
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 2002.05a
    • /
    • pp.242-242
    • /
    • 2002
  • Two MIMAS MaX fuel rods base-irradiated in a commercial PWR have been reinstrumented and irradiated at a test reactor. The fabrication data for two MOX roda are characterized together with base irradiation information. Both Rods were reinstrumented to be fitted with thermocouple to measure centerline temperature of fuel. One rod was equipped with pressure transducer for rod internal pressure whereas the other with cladding elongation detector. The post irradiation examinations for various items were performed to determine fuel and cladding in-pile behavior after base irradiation. By using well characterized fabrication and re-instrumentation data and power history, the fuel performance code, COSMOS, is verified with measured in-pile and PIE information. The COMaS code shows good agreement for the cladding oxidation and creep, and fission gas release when compared with PIE dad a after base irradiaton. Based on the re-instrumention information and power history measured in-pile, the COSMOS predicts re-instrumented in-pile thermal behaviour during power up-ramp and steady operation with acceptable accuracy. The rod internal pressure is also well simulated by COSMOS code. Therfore, with all the other verification by COSMOS code up to now, it can be concluded that COSMOS fuel performance code is applicable for the design and license for MaX fuel rods up to high burnup.

  • PDF

The Characteristics of Diurnal Changes in the Tissue-Water Relations of Pueraria thunbergiana (칡(Pueraria thunbergiana) 조직수분관계의 일변화 특성)

  • 박용목;최창렬
    • The Korean Journal of Ecology
    • /
    • v.21 no.1
    • /
    • pp.89-96
    • /
    • 1998
  • The diurnal changes of the stomatal conductance, transpiration and leaf water potential were measured in order to assess the water relations characteristics of Pueraria thunbergiana in August of 1995 and 1996. The results showed two different responses depending on the duration of rainless days. The microclimatic conditions were highly stressful on 2 August. Daily maximum temperature reached to $39.0{\circ}C$ and vapor pressure deficit was 3.55 KPa. During this time the leaf water potential decreased to -1.02 MPa and a marked reduction of stomatal conductance was shown. However, on 15 August the stomatal conductance increased with increment of photon flux density, and transpiration was highly maintained during the day time. Minimum leaf water potential was only -0.47 MPa in spite of high transpiration rate. Furthermore, on 15 August reduced leaf water potential during the day time was recovered rapidly with decrease of photon flux density, whereas recovery of leaf water potential on 2 August was delayed. However, reduced leaf water potential on 2 August was recovered untile the next dawn. Osmotic potential at turgor loss point of Pueraria thunbergiana on 2, 3 and 15 August was -1.79, -1.70 and -1.60 MPa, respectively. The vapor pressure deficit is more contributive to the regulation of stomatal conductance than leaf water potential.

  • PDF

Analysis of Flow through High Pressure Bypass Valve in Power Plant (발전소용 고압 바이패스 밸브 내부 유동해석)

  • Cho, An-Tae;Kim, Kwang-Yong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.10 no.6
    • /
    • pp.17-23
    • /
    • 2007
  • In the present work, flow analysis has been performed in the steam turbine bypass control valve (single-path type) for two different cases i.e., case with steam only and case with both steam and water. The numerical analysis is performed by solving three-dimensional Reynolds-averaged Navier-Stokes (RANS) equations. The shear stress transport (SST) model and $k-{\varepsilon}$ model are used to each different case as turbulence closure. Symmetry condition is applied at the mid plane of the valve while adiabatic condition is used at the outer wall of the cage. Grid independency test is performed to find the optimal number of grid points. The pressure and temperature distributions on the outer wall of the cage are analyzed. The mass flow rate at maximum plug opening condition is compared with the designed mass flow rate. The numerical analysis of multiphase mixing flow(liquid and vapor) is also performed to inspect liquid-vapor volume fraction of bypass valve. The result of volume fraction is useful to estimate both the safety and confidence of valve design.

Experimental Investigation on the Vapor Explosions with Water/R22 (Water / R22 폭발실험수행을 통한 증기폭발에 관한 연구)

  • Park, I.K.;Park, G.C.
    • Nuclear Engineering and Technology
    • /
    • v.26 no.2
    • /
    • pp.257-264
    • /
    • 1994
  • Experimental studies hate been peformed to investigate vapor explosion phenomena which may threaten the containment integrity during severe accidents in nuclear power plants. In this study, experimental equipment is constructed for vapor explosion experiments, and the vapor explosion experiments were conducted using water/R22. During the experiments, water/R22 interaction phenomena were observed using the high speed camera, and the explosion pressure and released mechanical energy were measured with pressure transducer and pressure relief tube. And the effects of some important parameters-hot liquid temperature, hot liquid injection velocity, hot liquid injection velocity, hot liquid injection time, and cold liquid depth-were investigated on the vapor explosion. Also, the experiment with grid was conducted to study reactor -vessel-lower-structure effect on fuel/coolant interaction. Water/R22 explosion conversion ratios were measured between 0.5∼1.6%.

  • PDF

An experimental study of the overall characteristics in an aero-valved pulsating combustor (空氣밸브型 脈動燃燒器의 特性에 관한 實驗的 硏究)

  • 오상헌;최병륜;임광열
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.11 no.2
    • /
    • pp.271-278
    • /
    • 1987
  • The experimental study was carried out to investigate the pressure fluctuation, operating frequency, noise emission and combustion characteristics in an aero-valved pulsating combustor. Measurements of the pressure fluctuation, mean temperature and ion current inside the combustion chamber indicate that combustion phenomena are characteristically similar to those in the diffusion flame. The measured frequency schedue indicates that the acoustic theory of the quarter wave tube can be approximated to give the operating frequency, but correction factor must be involved to estimate the correct operating frequency. The spectral behavior of the noise emission exhibits that frequency bands with high noise intensity are narrowly restricted to the neighborhood of the operating frequency signalling the low-frequency combustion characteristics of the pulsating combustor. Measurements of the operating characteristics as variation of the fuel nozzle diameter and injection angle with 4 fuel nozzles have been made, and it was found that the system produced the stable operating conditions up to the turn down ratio of 3 when the fuel nozzle diameter is 1.2mm, and the optimum fuel injection angle is thought to be in the neighborhood of 30.deg. radially.

Correlation between Volume and Pressure of Dichloromethane using Equation of State (상태방정식을 이용한 디클로로메탄의 부피와 압력간 상관관계 연구)

  • Kwon, Woong;Kim, Jiyun;Lee, Kwonyun;Jeong, Euigyung
    • Textile Coloration and Finishing
    • /
    • v.33 no.3
    • /
    • pp.141-146
    • /
    • 2021
  • Supercritical fluid has excellent dissolving power for various materials based on low viscosity and high diffusion coefficient and is used as solvents in various chemical processes. However, its industrial application can be very tricky because the design, especially the size of the supercritical apparatus, should be carefully chosen to optimize the cost and the production of supercritical fluidic state. And the first step of the supercritical fluid apparatus design is to choose the appropriate size of the reactor vessel to produce supercritical fluid above its critical pressure and temperature. Therefore, this study aims to analyze thermodynamic behaviors of dichloromethane based on ideal gas, van der Waals, Redlich-Kwong, Soave-Redlich-Kwong, and Peng-Robinson equations of state. The correlation between the volume and pressure of dichloromethane at 200℃ was revealed and it can be used to design the optimized size of the supercritical apparatus for industrial production.

Comparison of Liquid- and Vapor-Phase Spray Characteristics of E85 Fuel using Schlieren Visualization Technique (쉴리렌 가시화 기법을 이용한 E85 연료의 액상 및 기상 분무 비교)

  • Park, Suhan;Chang, Mengzhao
    • Journal of Institute of Convergence Technology
    • /
    • v.8 no.1
    • /
    • pp.9-13
    • /
    • 2018
  • The purpose of this study is to investigate the liquid- and vapor-phase spray characteristics, such as spray tip penetration and spray angle using gasoline direct injection (GDI) injector with multi-hole. The vapor-phase spray was captured by the Schlieren visualization system, which consists of high-speed camera, LED lamp, concave mirrors, and knife-edge. The liquid-phase spray was visualized by Mie-scattering techniques. Both spray images of vapor- and liquid-phase were visualized under 373 K of ambient temperature, 1 bar of ambient pressure, and 100/200 bar of injection pressure. The energizing duration was fixed at 1.5 ms. From the analysis of experimental results, it revealed that the increased injection pressure induced an early vaporization due to the improvement of droplet atomization. The spray tip penetration and spray angle in vapor-phase were higher than those in liquid-phase. The difference in the spray tip penetration between vapor- and liquid-spray gradually increased with the time elapsed after the injection. Even with the spray angle characteristics, it was found that the difference between the spray angle of liquid and vapor spray gradually grew after they entered steady-state conditions.

Analysis of Efficiency Enhancement of the Integrated Gasification Combined Cycle with Oxy-Combustion Carbon Capture by Changing the Oxygen Supply System (순산소연소 이산화탄소 포집을 적용한 석탄가스화 복합화력 발전시스템에서 산소공급방식 변경에 의한 효율향상 분석)

  • CHO, YEON WOO;AHN, JI HO;KIM, TONG SEOP
    • Journal of Hydrogen and New Energy
    • /
    • v.30 no.4
    • /
    • pp.347-355
    • /
    • 2019
  • As a solution to the growing concern on the global warming, researches are being actively carried out to apply carbon dioxide capture and storage technology to power generation systems. In this study, the integrated gasification combined cycle (IGCC) adopting oxy-combustion carbon capture was modeled and the effect of replacing the conventional air separation unit (ASU) with the ion transport membrane (ITM) on the net system efficiency was analyzed. The ITM-based system was predicted to consume less net auxiliary power owing to an additional nitrogen expander. Even with a regular pressure ratio which is 21, the ITM-based system would provide a higher net efficiency than the optimized ASU-based system which should be designed with a very high pressure ratio around 90. The optimal net efficiency of the ITM-based system is more than 3% higher than that of the ASU-based system. The influence of the operating pressure and temperature of the ITM on system efficiency was predicted to be marginal.