Micro-discharged plasma density, electron temperature and excited xenon density for enhancement of vacuum ultraviolet luminous efficiency in alternating current plasma display panel

  • Choi, Eun-Ha;Oh, Phil-Yong;Seo, Yoon-Ho;Cho, Guang-Sup;Uhm, Han-S
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.161-166
    • /
    • 2005
  • The plasma ion density in AC-PDP has shown to be increased from $5.6{\times}10^{11}cm^{-3}$ to $9.0{\times}10^{11)cm^{-3}$ as the Xe mixture ratio to neon increase from 1 % to 10 %, respectively, at fixed pressure of 400 Torr, by using the micro-Langmuir probe. It is noted that the plasma ion density is density increases as the gas pressure increases in this experiment. The electron temperature decreases from 2.3 to 1.2 eV as the Xe mole fraction increases from 1 % to 10 % at fixed pressure of 400 Torr, which is measured by the micro Langmuir probe and high-speed ICCD camera in this experiment. It is noted that the electron temperature decreases as the gas pressure increases from 150 to 400 Torr in this experiment. It is also observed that the exited Xe atom density and the plasma ion density are in strong correlation sharp between each other in this experiment. It is noted that $5.2{\times}10^{12}cm^{-3}$ in the $1s_5$ metastable state and $1.2{\times}10^{12}cm^{-3}$ in the $1s_4$ resonance state for the PDP cell with gap of 50 um distances under the fixed gas pressure of 400 Torr and Xe content ratio of 10 %.

  • PDF

The Physicochemical Properties on the Charge Transfer Complexes under High Pressure (고압하의 전하이동착물에 대한 물성론적 연구-사염화탄소 용액내에서 헥사메틸벤젠과 여러 전자받게들간의 전하이동착물 생성에 대한 압력과 온도의 영향)

  • Kwun Oh Cheun;Kim Myong Ja;Kim Se Kyung
    • Journal of the Korean Chemical Society
    • /
    • v.35 no.4
    • /
    • pp.335-342
    • /
    • 1991
  • The effect of pressure and temperature on the stabilities of the charge transfer complexes of 1,3,5-trinitrobenzene, tetrachloro-p-benzoquinone and tetracyanoethylene with hexamethylbenzene in carbon tetrachloride has been investigated by spectrophotometric measurements. The equilibrium constants for the formation of the complexes were obtained at various temperature and pressure, and thermodynamic parameters for the formation of the charge transfer complexes are calculated from these values. The relative stabilities of charge transfer complexes with hexamethylbenzene increase in the order; 1,3,5-trinitrobenzene < tetrachloro-p-benzoquinone < tetracyanoethylene. This may be regarded as an order of relative acidity of these compounds in complexation with hexamethylbenzene and is explained in terms of the negative inductive effect of the ${\pi}$ acceptors. The red-shift at higher pressure, the blue-shift at higher temperature and the relation between pressure and oscillator strength are discussed on the basis of thermodynamic functions.

  • PDF

An Analysis of the Effect of Pressure Ramp Rate on the Major Parameters of the Standard Hydrogen Fueling Protocol (수소충전 시 압력상승률이 표준충전프로토콜 중요변수에 미치는 영향 해석)

  • Chae, Chungkeun;Kim, Yonggyu;Chae, Seungbeen
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.1
    • /
    • pp.23-32
    • /
    • 2020
  • It is not easy to fully fuel high pressure(70 MPa) hydrogen in a hydrogen vehicle tank quickly. This is because the temperature inside the tank rises rapidly due to heat caused by the Joule-Thomson effect, etc. So fueling protocols such as SAE J2601 in the U.S. and JPEC-S 0003 in Japan appeared. However, there is a problem with these protocols that a number assumption are introduced and the content is too complex and limited in scope. This study was conducted to develop a new protocol based on complete real-time communication. In this study, the hydrogen fueling simulation program were used to examine how the pressure ramp rate affects the temperature and pressure rise in the tank and the fueling flow rate. The results confirmed that the first parameter to be considered in determining the pressure ramp rate is the temperature of the tank.

Mechanical Properties and Fabrication of Nanostructured ReSi1.75 by High Frequency Induction Heated Combustion Synthesis (고주파유도가열 연소합성에 의한 나노구조 ReSi1.75 제조 및 기계적 성질)

  • Kim, Byung-Ryang;Kim, Su-Chul;Shon, In-Jin
    • Journal of Powder Materials
    • /
    • v.16 no.1
    • /
    • pp.16-21
    • /
    • 2009
  • Nanostructured $ReSi_{1.75}$ was synthesized to have high density via rapid and cost effective process named as high-frequency induction heated combustion synthesis(HFIHCS) method. For the process, mechanically activated Re-Si powder was used, which had been prepared by mechanical ball milling of Re and Si powders with mixing ratio of 1:1.75. Both combustion synthesis and densification were accomplished simultaneously by applying electric current and mechanical pressure of 80 MPa during the process. The average grain size, hardness, and fracture toughness of the compound were 210 nm, 1085 $kg/mm^2$ and 4 $MPa{\cdot}m^{1/2}$, respectively. The experimental results show that HFIHCS is a promising process for synthesis of nanostructured $ReSi_{1.75}$ which has a potential for both high temperature and thermo-electric applications.

A Design Technology of Ceramic Tube for High Efficiency Ozone

  • Cho, Kook-Hee;Kim, Young-Bae;Lee, Dong-Hoon
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.3C no.3
    • /
    • pp.77-80
    • /
    • 2003
  • An innovative ozonizer has been developed using a high frequency, surface discharge and a high purity Ti-Si-AI ceramic catalyst as a dielectric component. Using a type of thin film, a thin cylindrical compound ceramic catalyst layer was adhered to the outside surface of its inner electrode. An alternating current (AC) exciting voltage with frequencies from 0.6 KHz to 1.0 KHz and peak-to-peak voltages of 4-6 ㎸ was applied between the electrodes to produce a stable high-frequency silent discharge. A substantial reduction of the exciting voltage was also enabled by means of a thin Ti-Si-Al ceramic catalyst tube. As a result, the ozonizer can effortlessly obtain the required ozone concentration (50-60 g/$m^2$ for oxygen) and high ozone efficiency consumption power (180 g/kWh for oxygen) with-out the assistance of any particular methods. For purposes of this experiment, oxygen gas temperature was set at 2$0^{\circ}C$, with an inner reactor pressure of 1.6 atm at 600 Hz and a flow rate of 2 l/min.

Investigation on high gradient magnetic separation for CRUD material in nuclear reactor

  • Shigehiro Nishijima;Naoki Nomura;Fumihito Mishima;Tomokazu Sekine
    • Progress in Superconductivity and Cryogenics
    • /
    • v.26 no.3
    • /
    • pp.5-8
    • /
    • 2024
  • In this study, we investigated high-gradient magnetic separation as a method for separating crud in high-temperature, high-pressure water inside a nuclear reactor. Corrosion products in the coolant circulate through the system and attach to the reactor core, where they are activated by neutron irradiation. The activated corrosion products then desorb from the core and circulate through the cooling system again. The corrosion product in the reactor water or piping system is called crud. Crud is the main source of radiation exposure for radiation workers. Removal and recovery of crud is important in decommissioning plants that have been in operation for service life, and new technologies are also desired. A method for separating activated ions adsorbed on ion exchange resins in nuclear reactors using magnetic separation is developed. In this method, the ion exchange resin is washed with acid, the activated ions are adsorbed from the washing water using adsorbents, and then separated magnetically. Rudimentary experiments were conducted to investigate the possibility of this method.

PREPARATION OF DIAMOND FILM BY DC THERMAL PLASMA (직류 열 플라즈마를 이용한 다이아몬드 합성에 관한 연구)

  • Kim, Won-Kyu;Whang, Ki-Woong
    • Proceedings of the KIEE Conference
    • /
    • 1990.11a
    • /
    • pp.101-105
    • /
    • 1990
  • A DC thermal plasma system has been designed and constructed to obtain diamond films from a mixture of CH4 and H2. The effects of the deposition conditions such as substrate temperature ($850^{\circ}C-1050^{\circ}C$), gas mixing ratio (0.5-1.5% CH4 in H2), chamber pressure (50 - 200 Torr), axial magnetic field (0 - 900 Gauss) on the diamond film properties such as morphology, purity of the film and deposition rate, etc. have been examined with the aids of Scanning Electron Microscopy, X-Ray Diffraction and Raman Spectroscopy. Under optimum conditions, high quality diamond films can be obtained with high deposition rate (>$1{\mu}m/min$). Both of the growth rate and' particle size increased with the substrate temperature but the morphology changed from the faceted to unshaped when the temperature deviates its proper range. Furthermore, higher growth rates of $1.5{\mu}m/min$ can be obtained by applying an axial magnetic field to plasma torch. The observed values of interplanar spacings of diamond were in a good agreement with the values reported in ASTM data and all deposits have the diamond peak of $1332.5\;cm^{-1}$ in the Raman Spectra.

  • PDF

Disinfection of Water by Ultrasonic Irradiation (초음파 검사에 의한 수중의 살균처리)

  • 손종렬;유병성
    • Journal of environmental and Sanitary engineering
    • /
    • v.14 no.1
    • /
    • pp.54-61
    • /
    • 1999
  • The industrial techniques of ultrasound have been used in the various fields, such as cleaning, medical surgery, emulsification, cell disruption etc. Especially the application of cell disruption was interested in the field of disinfection process in water by ultrasonic irradiation. It has been recognized that the ultrasounds are irradiated in aqueous solution, cavitation bubbles are generated and shock waves of high temperature and pressure are emitted as the bubbles are developed and finally broken, which function as a energy source to promote reaction efficiencies of various kinds of chemical reactions such as disinfection reaction in water. Therefore, this study was performed to apply the ultrasound for the disinfection method of infected drinking raw water and to discuss the limiting factors such as pH, sample volume and reaction temperature influenced on the removal efficiency of E. coli from experimental analysis of the results obtained in bench-scale plant. For the experiments to measure the influence of reaction parameters in the ultrasonic disinfection process, escalated reactivity of aqueous solutions was excellent when pH in aqueous solution was low, and sample volume was small. On the contrary, the reactivity of disinfection became elevated when reaction temperature was high. It was found that the rate constant of disinfection reaction was applied by Chick's law, reaction kinetics of Chick's law was irreversible and pseudo-first order at all the tested conditions.As a conclusion it appeared that the technology using ultrasonic irradiation can be applied to the treatment of disinfection in infected water which are difficult to be treated by conventional methods.

  • PDF

Measurement of Heat Transfer and Friction Coefficients for Flow of Air in Noncircular Ducts At High Surface Temperatures. (공기유동에 대한 고온상태의 비원형 도과내에서의 열전달 및 압력강하의 측정)

  • 이동렬
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.25 no.3
    • /
    • pp.552-562
    • /
    • 2001
  • Measurement of average of heat transfer and friction coefficients were obtained with air flowing through electrically heated ducts having square, rectangular(aspect ration, 5), and triangular cross section for range of surface temperature from $540^{\circ}$to $1780^{\circ}$ R and Reynolds number from 1000 to 330,000. The results indicates that the effect of heat flux on correlations of the average heat transfer and friction coefficients is similar to that obtained for circular tubes in previous investigation and was nearly eliminated by evaluating the physical properties and density of the air a film temperature halfway between the average surface and fluid bulk temperatures, With the Nusselt and Reynolds numbers on the hydraulic diameter of the ducts, the data for the noncircular ducts could be represented by the same equations obtained in the previous investigation for circular tubes. Correlation of the average difference between the surface corner and midwall temperatures for the square duct was in agreement with predicted values from a previous analysis. However, for the rectangular and triangular ducts, the measured corner temperature was greater by approximately 20 and 35 percent, respectively, than the values predicted by analysis.

  • PDF

Temperature Effect in the process of DAF as pretreatment of SWRO (해수담수화 전처리로서 DAF공정에서 고온의 해수에 대한 영향 특성)

  • Park, Hyunjin;Dockko, Seok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.6
    • /
    • pp.807-813
    • /
    • 2012
  • Flocculation and flotation are used as pretreatment steps prior to the reverse osmosis (RO) process. During seawater treatment, high temperature can change the water chemistry of seawater during the process of coagulation. It also affects bubble volume concentration (BVC) and bubble characteristics. Coagulants such as alum and ferric salts at $40^{\circ}C$ can also change flux rates in the seawater reverse osmosis (SWRO) process. In this study, the bubble characteristics in dissolved air flotation (DAF), used as a SWRO pretreatment process, were studied in synthetic seawater at $20^{\circ}C$ and $40^{\circ}C$. The flux of an RO membrane was monitored after dosing the synthetic seawater with coagulants at different temperatures. Results showed that BVC increases as the operating pressure increases and as the salt concentration decreases. The bubble size released at $40^{\circ}C$ is far smaller than that at $20^{\circ}C$The addition of a ferric salt is effective for turbidity removal in synthetic seawater at $20^{\circ}C$; it is more effective than alum. When synthetic seawater was dosed with a ferric salt, the RO membrane flux increased by 27 % at $40^{\circ}C$.