• Title/Summary/Keyword: high temperature high pressure

Search Result 4,161, Processing Time 0.035 seconds

The influence of atomosphere on high temperature crystal growth

  • Klimm, D.;Schroder, W.
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.9 no.4
    • /
    • pp.360-364
    • /
    • 1999
  • The growth of crystals with high melting point$t_{fus}$$\geq$$1600^{\circ}C$ faces the researcher with experimental problems, as the choice of materials that withstand such high t is rather limited. Many metallic construction materials are in this high t range already molten or exhibit at least a drastically reduced mechanical strength. The very few materials with$t_{fus}$$1600^{\circ}C$ as e.g. W, Mo, and partially even Ir are more or less sensitive against oxygen upon heating. Whenever possible, high t crystal growth is performed under inert atmosphere (noble gases). Unfortunately, many oxides are not thermodynamically stable under such conditions, as reduction takes place within such atmosphere. A thoroughly search for suitable growth conditions has to be performed, that are on the one side "oxidative enough" to keep the oxides stable and on the other side "reductive enough" to avoid destruction of constructive parts of the crystal growth assembly. The relevant parameters are t and the oxygen partial pressure${po}_{2}$. The paper discusses quantitatively relevant properties of interesting oxides and construction materials and wasy to forecast theri behavior under growth conditions.

  • PDF

Application Examples of CFD at the Planning Stage of High-Rise Buildings

  • Hiroto, Kataoka;Yoshiyuki, Ono;Kota, Enoki;Yuichi, Tabata;Satoko, Kinashi
    • International Journal of High-Rise Buildings
    • /
    • v.11 no.3
    • /
    • pp.145-156
    • /
    • 2022
  • Application examples of computational fluid dynamics (CFD) in the planning stage of high-rise buildings are introduced. First, we introduce examples of applications in the environmental field. The pedestrian wind environment was one of the earliest practical examples of CFD. CFD was also employed to validate the heat island mitigation measures proposed as part of the new construction plan. Second, application examples of wind-force evaluations are introduced. Prediction examples are presented for the peak wind pressure around a complex-shaped building and the wind force evaluation for a base-isolated building. The results prove that the results of the proper execution of CFD are equivalent to those of the wind tunnel experiment. As examples of CFD applications of other issues related to high-rise building planning, we introduce snow accretion on outer walls and high-temperature exhaust from emergency generators. Finally, the future prospects for the use of CFD are discussed.

The Influence of Atmostphere on High Temperature Crystal Growth

  • Klimm, D.;Schroder, W.
    • Proceedings of the Korea Association of Crystal Growth Conference
    • /
    • 1999.06a
    • /
    • pp.51-67
    • /
    • 1999
  • The growth of crystals with high melting points tfus$\geq$1$600^{\circ}C$ faces the researcher with experimental problems, as the choice of materials that withstand such high t is rather limited. Many metallic construction materials are in this high t range already molten or exhibit at least a drastically reduced mechanical strength. The very few materials with tfus》1$600^{\circ}C$ as e.g. W, Mo, and partially even Ir are more or less sensitive against oxygen upon heating. Whenever possible, high t crystal growth is performed under inert atmosphere (noble gases). Unfortunately, any oxides are not thermodynamically stable under such conditions, as reduction takes place within such atmosphere. A thoroughly search for suitable growth conditions has to be performed, that are on the one side "oxidative enough" to keep the oxides stable and on the other side "reductive enough" to avoid destruction of constructive parts of the crystal growth assembly. The relevant parameters are t and the oxygen partial pressure pO2. The paper discusses quantitatively relevant properties of interesting oxides and construction materials and ways to forecast their behavior under growth conditions.r growth conditions.

  • PDF

A Study on Injection Characteristics of High Temperature Fuel through Orifice Injectors (고온 연료의 오리피스 인젝터 분사특성 연구)

  • Lee, Hyung Ju;Choi, Hojin;Kim, Ildoo;Hwang, Ki-Young
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.42 no.2
    • /
    • pp.119-126
    • /
    • 2014
  • An experimental study was conducted to study fuel injection characteristics through plain orifice injectors when the fuel was heated to the temperature higher than its boiling point. Three injectors with different orifice diameters were used to measure the flow coefficient (${\alpha}$) for the injection pressure ranges of 3, 5, and 10 bar and the fuel temperature ranges between 50 and $270^{\circ}C$. The study showed that ${\alpha}$ decreases gradually with the fuel temperature below $180^{\circ}C$ while it drops abruptly when the temperature goes beyond $187^{\circ}C$, the boiling temperature of the fuel. The slope of ${\alpha}$ bifurcated at the boiling temperature for different injection pressures, and ${\alpha}$ decreased faster for the lower injection pressure due to the more active boiling in the injector. In addition, the larger orifice diameter had the higher ${\alpha}$ value, and ${\alpha}$ jumped at moderate temperature ranges when the injection pressure was low, implying the turbulent-laminar transition phenomena. The measured ${\alpha}$ was plotted against the cavitation number($K_c$), and the characteristics were independent of the applied pressure for small injectors when the fuel was evaporated before it was injected.

Combustion Control through the DME Injection Timing in the Hydrogen-DME Partially Premixed Compression Ignition Engine (DME 분사 시기 조절을 통한 수소-DME 부분 예혼합 압축착화 연소 제어)

  • Jeon, Jeeyeon;Bae, Choongsik
    • Journal of the Korean Society of Combustion
    • /
    • v.18 no.1
    • /
    • pp.27-33
    • /
    • 2013
  • Hydrogen-dimethy ether(DME) partially premixed compression ignition(PCCI) engine combustion was investigated in a single cylinder compression ignition engine. Hydrogen and DME were used as low carbon alternative fuels to reduce green house gases and pollutant. Hydrogen was injected at the intake manifold with an injection pressure of 0.5 MPa at fixed injection timing, $-210^{\circ}CA$ aTDC. DME was injected directly into the cylinder through the common-rail injection system at injection pressure of 30 MPa. DME inejction timing was varied to find the optimum PCCI combustion to reduce CO, HC and NOx emissions. When DME was injected early, CO and HC emissions were high while NOx emission was low. As the DME injection was retarded, the CO and HC emissions were decreased due to high combustion efficiency. NOx emissions were increased due to the high in-cylinder temperature. When DME were injected at $-30^{\circ}CA$ aTDC, reduction of HC, CO and NOx emissions was possible with high value of IMEP.

A Study on the Wall Thinning Range according to modified Extraction Nozzle Design in High Pressure Feedwater Heater (고압 급수가열기 추기노즐 설계변경에 따른 감육 범위 연구)

  • Park, Sang-Hoon;Yoo, Il-Gon;Kim, Kyung-Hoon;Hwang, Kyeong-Mo
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.847-852
    • /
    • 2009
  • Feedwater heaters of many nuclear power plants have recently experienced severe wall thinning damange, which will increase as operating time progresses. Several nuclear power plants in Korea have experienced wall thinning damage in the area around the impingement baffle inside feed-water heater installed downstream of the turbine extraction stream line. At that point, the extract steam from the turbine is two phase fluid at high temperature, high pressure, and high speed. Since it flows to reverse direction after impinging the impingement baffle, the shell wall of feedwater heaters may be affected by flow-accelerated corrosion. In this paper, to compare wall thinning range according to change entrance nozzle diameter and position with reference numerical analysis model's wall thinning range, various numerical analysis models applied. In case of changing diameter, four different diameter is applied. And a side of nozzle position, two different position-vertical type and parallel type-is applied. And then this paper describes operation of numerical analysis which is composed similar condition with real feed water heater. In conclusion, this study shows effective design for shall wall thinning by changing nozzle diameter and position.

  • PDF

A Study on the Control Performance for Hazardous Gases by Surface Discharge induced Plasma Chemical Process (연면방전의 플라즈마 화학처리에 의한 유해가스제어 성능에 관한 연구)

  • 이주상;김신도;김광영;김종호
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.11 no.2
    • /
    • pp.185-190
    • /
    • 1995
  • Recently, because of the worse of the air pollution, the excessive airtught of building and the inferiority of air conditioning system, the development of high efficiency air purification technology was enlarged to the environmental improvement of an indoor or a harmful working condition. The air purification technology has used chemical filters or charcoal filters or charcoal to remove hazardouse gaseous pollutants (SO$_{x}$, NO$_{x}$, NH$_{3}$, etc.) by air pollutant control technology, but they have many problems of high pressure loss, short life, wide space possession, and treatment of secondary wastes. For these reason, the object of reasearch shall be hazardous gaseous pollutants removal by the surface discharge induced plasma chemical process that is A.C. discharge of multistreams applied A.C. voltage and frequency between plane induced eletrode and line discharge eletrode of tungsten, platinum or titanium with a high purified alumina sheet having a film-like plane. As a result, the control performance for hazardous gaseous pollutants showed very high efficiency in the normal temperature and pressure. Also, after comtact oxidation decomposition of harmful gaseous pollutants, the remainded ozone concentration was found much lower than that of ACGIH or air pollution criteria in Korea.rea.

  • PDF

Utilization of Pine Bark (Part 7) -Applicability of Spent Liquor Obtained from Alkaline Sulfite-Anthraquinone (AS-AQ) Cooking of Pine Bark as a Deinking Agent- (소나무 수피의 총합적 이용(제7보) -소나무 수피 AS-AQ 증해폐액의 탈묵제로서의 적용 가능성-)

  • 문성필;박성천
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.33 no.4
    • /
    • pp.42-48
    • /
    • 2001
  • The spent liquor (BSL) obtained from alkaline sulfite-anthraquinone (AS-AQ) cooking of pine bark was applied as a deinking agent. In the ONP deinking system, although BSL removed the small size of ink particles (${\geq}$$12.5{\mu}m$), it did not improve the brightness of pulp. The brightness of pulp slightly improved when treated with BSL at 150~$180^{\circ}C$. However, the brightness of the pulp was lower than that of a commercial deinking agent (oleic acid). It seems that BSL treated with a high temperature still had a high dispersing ability on the ink particles. Intensive oxidations were introduced, and remarkable deinking effects were observed at 13kgf/$cm^2$ oxygen pressure, $160^{\circ}C$ and 2h. When BSL treated at 13kgf/$cm^2$ oxygen pressure, $170^{\circ}C$ and a time period of 30~90 min is added to the pulp, at 0.1% or lower, the deinking effect became higher than that of oleic acid. On the other hand, additional alkali treatments during the oxidation possibility as a deinking agent when oxidized. However, since the oxidized BSL still has a high dispersing ability and lower molecular weight, several modifications need to be done in the near future in order to be applied as a high quality deinking agent.

  • PDF

Applicability Evaluation of Methodology for Evaluating High Cycle Thermal Fatigue of a Mixing Tee in Nuclear Power Plants (원전 혼합배관 고주기 열피로 평가방법론의 적용성 평가)

  • Kim, Sun-Hye;Sung, Hee-Dong;Choi, Jae-Boong;Huh, Nam-Su;Park, Jeong-Soon;Choi, Young-Hwan
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.7 no.4
    • /
    • pp.44-50
    • /
    • 2011
  • Turbulent mixing of hot and cold coolants is one of the possible causes of high cycle thermal fatigue in piping systems of nuclear power plants. A typical situation for such mixing appears in turbulent flow through a T-junction. Since the high cycle thermal fatigue caused by thermal striping was not considered in the piping fatigue design in several nuclear power plants, it is very important to evaluate the effect of thermal striping on the integrity of mixing tees. In the present work, before conducting detailed evaluation, three thermal striping evaluation methodology suggested by EPRI, JSME and NESC are analyzed. Then, a by-pass pipe connected to the shutdown cooling system heat exchanger is investigated by using these evaluation methodology. Consequently, the resulting thermal stresses and the fatigue life of the mixing tee are reviewed and compared to each other. Futhermore, the limitation of each methodology are also presented in this paper.

Analysis of spray cone angle of air assisted flash atomization (공기보조식 (air-assisted) 플래쉬 분무의 분무 각 확대 특성 연구)

  • Yu, Tae-U;Kim, Sae-Won;Bang, Byong-Ryeol
    • Journal of ILASS-Korea
    • /
    • v.10 no.1
    • /
    • pp.1-9
    • /
    • 2005
  • When the water jets heated up to the saturation temperature at a high line pressure are sprayed into a reduced (atmospheric) pressure through an air-assisted nozzle, the jets experience sudden exposure into a reduced pressure, get superheated and produce steam bubbles while atomization processes of jets are taking place. This process is called flash atomization. In this study the flash atomization of superheated water jets assisted by air has been studied. Sprays with flash atomization have been photographed at various water and air flow rates and water superheats. It has been found that the spray angle with flash atomization increases with water superheat and water flow rate but decreases with air flow rate. The degree of change of spray angle has been analyzed and correlated as a function of superheat, air and water flow rates.

  • PDF