A Study on the Wall Thinning Range according to modified Extraction Nozzle Design in High Pressure Feedwater Heater

고압 급수가열기 추기노즐 설계변경에 따른 감육 범위 연구

  • 박상훈 (경희대학교 대학원 기계공학과) ;
  • 유일곤 (경희대학교 대학원 기계공학과) ;
  • 김경훈 (경희대학교 기계공학과) ;
  • 황경모 (한국전력기술(주))
  • Published : 2009.06.25

Abstract

Feedwater heaters of many nuclear power plants have recently experienced severe wall thinning damange, which will increase as operating time progresses. Several nuclear power plants in Korea have experienced wall thinning damage in the area around the impingement baffle inside feed-water heater installed downstream of the turbine extraction stream line. At that point, the extract steam from the turbine is two phase fluid at high temperature, high pressure, and high speed. Since it flows to reverse direction after impinging the impingement baffle, the shell wall of feedwater heaters may be affected by flow-accelerated corrosion. In this paper, to compare wall thinning range according to change entrance nozzle diameter and position with reference numerical analysis model's wall thinning range, various numerical analysis models applied. In case of changing diameter, four different diameter is applied. And a side of nozzle position, two different position-vertical type and parallel type-is applied. And then this paper describes operation of numerical analysis which is composed similar condition with real feed water heater. In conclusion, this study shows effective design for shall wall thinning by changing nozzle diameter and position.

Keywords