Proceedings of the SAREK Conference (대한설비공학회:학술대회논문집)
- 2009.06a
- /
- Pages.853-856
- /
- 2009
Study on Measurement of Flow Distribution for Design of Room Air Conditioner with High-Efficiency
고효율 룸 에어컨 설계를 위한 유동 분포 측정에 관한 연구
- Lee, Soo-Hong (Graduate School, Department of Mechanical Engineering, Sungkyunkwan University) ;
- Na, Seon-Uk (Samsung Electronics Co., LTD) ;
- Kang, Geun (Samsung Electronics Co., LTD) ;
- Ko, Han-Seo (School of Mechanical Engineering, Sungkyunkwan University)
- Published : 2009.06.25
Abstract
Test models which have geometrical similarities with a real room air conditioner (RAC) have been manufactured including visualization windows so that a laser beam can pass through a cross flow fan. Then, flow distributions of the RAC have been investigated using a visualization technique such as a Particle Image Velocimetry (PIV) to analyze an efficiency and noise of the RAC. Pitot tubes have also been used to measure the flow velocity inside the RAC with various positions to confirm the measurement accuracy of the PIV technique. The measured flow velocities have been analyzed and new designs of the RAC have been proposed to improve the efficiency and to reduce the noise for the RAC in this study.
Keywords