• 제목/요약/키워드: high strength reinforcing bars

검색결과 116건 처리시간 0.021초

섬유복합재봉(FRP ROD)과 고강도 모르터를 이용한 철근 콘크리트 구조물의 휨 보강공법(MFRI) 공법 (Reinforcing System(MFRI) for Concrete Structure using FRP ROD & High-performance Mortar)

  • 배기선;박상훈;이상욱
    • Composites Research
    • /
    • 제18권4호
    • /
    • pp.59-65
    • /
    • 2005
  • This report is on the Reinforcing System(MFRI) for Concrete Structure using FRP ROD & High-Performance Mortar. The main characteristic of this system is as follow. First, the fiber rods in this system have seven times greater tensile strength than general reinforcing steel bars(re-bar) and the weight is a fifth lighter. Camels coated on the fiber rods' surfaces to improve adhesive strength and pull-out strength. Second, high strength shotcrete mortar is has very good workability and low rebound rate. After installing the Fiber Rods, Shotcrete mortar Is applied or sprayed to finish reinforcement. Finally, MFRI system has excellent fire-resisting performance and sogood tolerance against external environment by inserting fiber rods and reinforcing materials into mortar which has high compressive strength. It is applied to bridge slab, utility box and tunnel of civil engineering works, and beam and slab of building structures.

굳지 않은 콘크리트의 간극통과거동 (The Behavior of Fresh Concrete to Pass between Bars)

  • 오상균
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2002년도 학술논문발표회
    • /
    • pp.97-102
    • /
    • 2002
  • The ability to pass between bars is one of the most important performance of self-compacting concrete or high-flowability concrete since it determines the final filling capacity which influences the strength and durability of hardened concrete in structure. Therefore it has been evaluated by many researchers using different kinds of testing apparatuses. The assessments of passing ability, however, differ largely according to the style, the dimension and the criteria in apparatuses, and the value obtained from one apparatus cannot be converted those of the others. There needs a rheological approach to the better understanding of the passing behavior of fresh concrete between reinforcing bars, where the flow velocity of concrete becomes slow and the blockade sometimes occurs due to the interference between aggregates and reinforcing bars. Experimental works were conducted to clarity the effects of the clearance between reinforcing bars, the volume of aggregate and the rheological properties of matrix on the behavior from the rheological point view and showed the rational mix proportioning of concrete.

  • PDF

지압각 감소이론을 이용한 높은마디면적 철근의 부착강도 해석 (Bond Strength Analysis of High Relative Rib Area Bars Using Decreasing Bearing Angle Theory)

  • 양승열;서동민;박영수;홍건호;최완철
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.185-188
    • /
    • 2005
  • Bond between reinforcing bar and surrounding concrete is supposed to transfer load safely in the process of design of reinforced concrete structures. Bond strength of ribbed reinforcing bars tends to split concrete cover, by wedging action, or shear the concrete in front of the ribs. In this study, using a reducing bearing angle theory, bond strengths of beam end specimen are predicted. Values of bond strength obtained using the analytical model are in good agreement with the bond test results. The analytical model provides insight into bond mechanism and the effects of bearing angle on the bond strength of deformed bars to concrete.

  • PDF

고강도 모르타르 충전식 철근이음의 구조성능에 관한 실험연구 (Structural Performance of High Strength Grout-Pilled Splice Sleeve System)

  • 김형기;안병익;남재현;박복만
    • 콘크리트학회논문집
    • /
    • 제13권5호
    • /
    • pp.516-524
    • /
    • 2001
  • 여러가지 철근이음 방법중에서 고강도 모르타르 충전식 철근이음은 철근위치의 오차를 쉽게 흡수하여 시공이 용이하고 또한 최근에 많이 사용되고 있는 대구경 철근에 대해서도 적용성이 양호하기 때문에 프리캐스트 공법의 철근이음 방법으로 매우 유효한 수단이 된다. 이에 본 연구에서는 모르타르 충전식 철근이음법의 적용범위를 보다 확장하기 위하여 슬리브에 매입되는 철근직경이 상이한 경우와 충전 모르타르 강도를 700kgf/$\textrm{cm}^2$대로 낮춘 경우의 모르타르 충전식 철근이음에 대한 단조 및 반복가력 구조성능 실험을 실시한 후에 기존 실험결과와의 비교 분석을 통하여 다음과 같은 결론을 얻었다. 충전 모르타르 압축강도가 증가할수록 전체적인 구조성능은 증가하는 경향을 나타내었고 충전 모르타르 압축강도가 700kgf/$\textrm{cm}^2$이상이고 철근정착길이가 6.5d 이상이면 A급(AIJ 철근이음 성능 판정기준) 이상의 구조성능을 보유하고 있는 것이 확인되었다. 또한 슬리브 양단에 매입되는 철근의 직경이 상이한 경우는 굵은 철근에 대응되는 슬리브를 사용해야 하고 매입되는 가는 철근은 굵은 철근보다 2단계까지 가는 것을 사용할 수 있다는 것이 확인되었다.

Applicability of Cu-Al-Mn shape memory alloy bars to retrofitting of historical masonry constructions

  • Shrestha, Kshitij C.;Araki, Yoshikazu;Nagae, Takuya;Omori, Toshihiro;Sutou, Yuji;Kainuma, Ryosuke;Ishida, Kiyohito
    • Earthquakes and Structures
    • /
    • 제2권3호
    • /
    • pp.233-256
    • /
    • 2011
  • This paper investigates the applicability of newly developed Cu-Al-Mn shape memory alloy (SMA) bars to retrofitting of historical masonry constructions by performing quasi-static tests of half-scale brick walls subjected to cyclic out-of-plane flexure. Problems associated with conventional steel reinforcing bars lie in pinching, or degradation of stiffness and strength under cyclic loading, and in their inability to restrain residual deformations in structures during and after intense earthquakes. This paper attempts to resolve the problems by applying newly developed Cu-Al-Mn SMA bars, characterized by large recovery strain, low material cost, and high machinability, as partial replacements for steel bars. Three types of brick wall specimens, unreinforced, steel reinforced, and SMA reinforced specimens are prepared. The specimens are subjected to quasi-static cyclic loading up to rotation angle enough to cause yielding of reinforcing bars. Corresponding nonlinear finite element models are developed to simulate the experimental observations. It was found from the experimental and numerical results that both the steel reinforced and SMA reinforced specimens showed substantial increment in strength and ductility as compared to the unreinforced specimen. The steel reinforced specimen showed pinching and significant residual elongation in reinforcing bars while the SMA reinforced specimen did not. Both the experimental and numerical observations demonstrate the superiority of Cu-Al-Mn SMA bars to conventional steel reinforcing bars in retrofitting historical masonry constructions.

방청제에 의한 콘크리트 내의 철근 방식법에 관한 실험적 연구 (An Experimental Study on the Corrosion Protection Method of Reinforcing Steel in Concrete by Using Corrosion Inhibitor)

  • 배수호;정영수;권영우;김년산;권혁진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.710-713
    • /
    • 2000
  • The corrosion protection methods of reinforcing steel in concrete are the various methods such as increasing thickness of cover concrete, using of reinforcing bars coated with epoxy, dosage of corrosion inhibitor as concrete admixture, cathodic protection method and etc. The most economical method of them will be the corrosion protection method using corrosion inhibitor as concrete admixture. Therefore, the purpose of this research is to investigate the performance of corrosion protection of ordinary strength and high strength concrete using corrosion inhibitor, respectively. For this purpose, after manufacturing ordinary strength and high strength concrete with and without corrosion inhibitor, the accelerated corrosion tests for reinforcing steel were conducted according to the periodic cycles (140 day) of wetting ($65^{\circ}C$, 90% R.H.) and drying period ($15^{\circ}C$, 65% R.H.). As a result, th high strength concrete using corrosion inhibitor showed an excellent performance of corrosion protection.

  • PDF

고성능 Belite 시멘트 콘크리트의 철근 부착성능 (Bond Strength of Reinforcing Steel to High-Performance Concrete Using Belite Cement)

  • 김상준;조필규;허준;최완철
    • 콘크리트학회지
    • /
    • 제10권6호
    • /
    • pp.169-178
    • /
    • 1998
  • 고성능 belite 시멘트 콘크리트에 대한 부착특성에 대하여 코\ulcorner리트의 강도, 슬럼프, 배근위치, 피복두께 등의영향요인을 보단부시험체와 이음길이 보시험체를 통해 연구하였다. 동일한 압축강도의 1종 보통 포틀랜드 시멘트 콘크리트에 비해 부착강도는 약 10%증가하였고 압축강도 600kg/$\textrm{cm}^2$의고강도 belite 콘크리트에서 부착강도가 대체로 {{{{ SQRT { f'c} }} }}에 비례하였다. 유동성에 있어서 높은 슬럼프에 비해 ACI 318-95 규준에서 제시하는 상부근 계수 1.3이하의범위에 있었으며 이것은 고유동 belite 콘크리트가 블리이딩이나 골재분리가 적은 것으로 보여졌다. 또한 고강도 belite시멘트 콘크리트를 사용한 이음길이 보시험체에서 부착강도는 기존 예측식의 값보다다소 높게 나타났으며, 실리커흄, 플라이애쉬를 사용한 고강도 콘크리트 부착강도의 기존연구결과인 낮은 값과 차이를 보였다. 이상의 결과로 고유동, 고강도 belite 시멘트 콘크리트는 철근과의 부착성능이 다른 재료에 비해 양호한 것으로 나타났다.

Effect of reinforcement strength on seismic behavior of concrete moment frames

  • Fu, Jianping;Wu, Yuntian;Yang, Yeong-bin
    • Earthquakes and Structures
    • /
    • 제9권4호
    • /
    • pp.699-718
    • /
    • 2015
  • The effect of reinforcing concrete members with high strength steel bars with yield strength up to 600 MPa on the overall seismic behavior of concrete moment frames was studied experimentally and numerically. Three geometrically identical plane frame models with two bays and two stories, where one frame model was reinforced with hot rolled bars (HRB) with a nominal yield strength of 335 MPa and the other two by high strength steel bars with a nominal yield strength of 600 MPa, were tested under simulated earthquake action considering different axial load ratios to investigate the hysteretic behavior, ductility, strength and stiffness degradation, energy dissipation and plastic deformation characteristics. Test results indicate that utilizing high strength reinforcement can improve the structural resilience, reduce residual deformation and achieve favorable distribution pattern of plastic hinges on beams and columns. The frame models reinforced with normal and high strength steel bars have comparable overall deformation capacity. Compared with the frame model subjected to a low axial load ratio, the ones under a higher axial load ratio exhibit more plump hysteretic loops. The proved reliable finite element analysis software DIANA was used for the numerical simulation of the tests. The analytical results agree well with the experimental results.

콘크리트 강도가 GFRP 복합재료 보강근의 부착강도에 미치는 영향 (Effect of Concrete Strength on the Bond Strength of Glass Fiber Reinforced Polymer Bars)

  • 김태영;박지선;이정윤;유영찬;김긍환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.189-192
    • /
    • 2005
  • Glass fiber reinforced polymer (GFRP) bars gain increasingly more attention as a reinforcing option for concrete because of their corrosion resistance and non-magnetism. GFRP reinforcement for concrete does not have the same shape as steel reinforcement. Therefore, the bond performance of FRP bars, unlike that of steel, is dependent on their design, manufacture and mechanical properties. This paper studied the effect of high strength concrete on the bond strength of GFRP bars. Twenty-nine specimens having different compressive strength of concrete were tested in order to examine the bond behavior of GFRP bars.

  • PDF

고강도 확대머리 인장철근을 가지는 SFRC 깊은 보의 전단강도 (Shear Strength of SFRC Deep Beam with High Strength Headed Reinforcing Tensile Bars)

  • 김영록;이창용;김승훈
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제23권5호
    • /
    • pp.111-117
    • /
    • 2019
  • 확대머리 SD600 고강도 인장철근으로 단부 정착된 SFRC 깊은보의 전단성능을 평가하기 위해 전단 실험을 수행하였다. 실험 변수는 주인장 철근의 단부 정착방법(확대머리 철근, 일자형 철근), 단부 정착길이, 전단보강근 유무 등이다. 전단경간비는 1을 가지는 실험체에 대한 전단실험결과, 모든 실험체는 초기 휨 균열이 발생한 후 경사균열이 진행되면서 최종적으로 압축전단파괴되었다. 확대머리 철근으로 기계적 정착된 실험체들이 일자형 철근 정착에 비하여 5.6~22.4% 더 큰 전단강도를 나타내었다. 확대머리 철근으로 기계적 정착된 실험체들에 대하여 최대하중의 75%까지는 지압응력이 전체 정착응력의 0.9~17.2%에 도달하였으나, 최대하중 시점에서 지압응력이 전체 정착응력의 22.4%~46%에 도달하여 큰 응력 부담률을 나타내었다. 이를 통하여 확대머리 지압응력에 의한 정착응력 증가가 전단강도에 큰 영향을 미침을 알 수 있다. 실험 전단강도가 실용식에 의한 전단강도의 2.68~4.65 배로 평가되어, 실용식이 전단내력을 안전측으로 평가하였다.