• 제목/요약/키워드: high safety

검색결과 10,491건 처리시간 0.039초

PL대응시스템 진단기법 (On the Diagnostic Methods for the Product Liability Management System)

  • 김종걸;빈성욱
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2004년도 춘계학술대회
    • /
    • pp.153-159
    • /
    • 2004
  • There are various types of PLM(product liability management) according to corporation management level. It is necessary to develop diagnostic methods and application systems for PLM as well as to establish an efficient PLM system. This paper aims to propose a PLM system which can be applied to product with high-reliability and high-safety, and diagnostic methods for PLM based on AHP, and also show an empirical application of the proposed PL management system for Auto Test Robot System of the Mobile Phone (EVT 4320).

  • PDF

국제표준기반의 고안전성 철도신호시스템 개발을 위한 형상관리프로세스 적용사례 연구 (A Case Study on the Application of Configuration Management Process for the Development of High-Safety Railway Signaling System Based on International Standards)

  • 최요철
    • 시스템엔지니어링학술지
    • /
    • 제15권2호
    • /
    • pp.108-115
    • /
    • 2019
  • The activities of managing and controlling the configuration of a system component over its life cycle are critical tasks in developing a high safety system as well as general system development. These configuration management activities should be defined through the management plan at the beginning of the life cycle, and should be performed continuously and systematically until the end of the project after the system or product development is completed. In this study, the configuration management process applied in the development of high safety railway signaling system was introduced and an efficient application proposals of it was proposed. In particular, configuration management through the establishment of a configuration management system based on computer tools is one of the important activities of maintaining the configuration integrity of the system or product.

초고층고층 건축물의 개구부에 대한 화재안전 설계방법 조사 (A Study on the Fire Safety Design Methods of Opening in High-rise Building)

  • 권영진;진승현;이병흔
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 춘계 학술논문 발표대회
    • /
    • pp.8-9
    • /
    • 2018
  • In recent years, the fire risk in the aged housing facilities in high-rise building has been closing up due to the fire in the Grenfell Tower. In the case of these high-rise residential facilities, fire cases of residential facilities such as Uijeongbu Apartment Fire The fire hazard has been reexamined mainly. Especially, the fire of these residential facilities is very closely related to the window, so measures are needed. On the other hand, in Korea, there is almost no fire safety measures against these openings. Therefore, this study suggests improvement measures by comparison with advanced countries based on fire safety measures for domestic windows.

  • PDF

자동차용 Adjust Plate Progressive 금형 개발 (Development of Adjust Plate Progressive Die)

  • 배용환;반갑수
    • 한국안전학회지
    • /
    • 제17권4호
    • /
    • pp.1-4
    • /
    • 2002
  • A automatic production system was developed for high productivity and safety. The semi-progressive die was unfavorable for more productivity, safety, material extravagance and incongruent high-speed production. Developed progressive die is suitable for the high production and guarantee triple production by acceptance of three array type for automobile adjust plate. We adopt Pro-$Engineer{\circledr}$ for three dimensional computer aided design suitable for the disassembly and assembly evaluation. The conclusion of this study is as follow. First, press die parts solid modeling system is built by using Pro-$Engineer{\circledr}$ through this research and verified allowable tolerance and possibility of assembly and disassembly of parts. Therefore we can reduce die manufacturing time and cost. Second, We produce 1000 units pet hot coil 1ton by traditional method, but we can acomplish material saving effect about 12% as 120 units in case of new progressive die. Fourth, we acomplished manufacturing cost curtailment effect more than 20% in comparison with traditional method.

고층 주거시설 화재사례를 고려한 인명안전기준 개선방안에 관한 연구 (A Study on the Improvement of Human Safety Standards Considering Fire Cases in High-rise Residential Facilities)

  • 조휘제;이병흔;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 봄 학술논문 발표대회
    • /
    • pp.106-107
    • /
    • 2021
  • The fire in Ulsan in 2020 was a 33-story residential and commercial complex with about 90 injuries and more than 10 billion won in property damage, and considering the recent increase in high-rise residential and commercial complexes, the risk of similar fires is high. As can be seen through the residential and commercial complex fire case in Ulsan, life-based fire safety standards need to be established to minimize casualties. Therefore, the purpose of this study is to draw improvements for the development of human safety standards for high-rise residential facilities in the future through comparison with the Korean Building Act, Firefighting-rellated Acts and the U.S. NFPA 101.

  • PDF

디지털 기술 활용 초고층 및 지하연계 복합건축물 피난안전 개선방안 연구 (A Study on improvement of evacuation safety in high-rise and underground complex buildings using digital technologies)

  • 서정완;김동오;이태규
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 가을학술발표대회논문집
    • /
    • pp.279-280
    • /
    • 2023
  • As buildings become taller and more complex, the number of high-rise and underground complex buildings is increasing, but risks are also increasing due to the limitations of existing evacuation safety methods. Through this study, we will analyze the fire and evacuation characteristics of high-rise and underground complex buildings, identify problems with the current evacuation safety method, and seek ways to improve them using digital technologies

  • PDF

차세대 고속철도 차량 모델의 1.2차 현가요소의 고장 발생 시 안전성 해석 (The Safety Analysis under failure of the 1st and 2ne Suspension Elements of the Next Generation High-speed Train model)

  • 김지영;박태원;윤지원;조재익
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.984-988
    • /
    • 2010
  • In Korea, the next generation high-speed train, whose target is maximum speed of 400km/h and operating speed of 370km/h, has been developed since 2007. In this paper, the safety of the next generation high-speed train is compared UIC 518OR under the malfunctioning situation of the suspension system. The bogie of the next generation high-speed train has two suspensions. Two different vehicle models of the next generation high-speed train are created by using VAMPIRE and ADAMS/Rail, which are specialized to design railway vehicle. And Those models are showed same dynamic properties. First of all, the sensitivity analysis of ModelCenter is performed using model of VAMPIRE. One suspension element which has significant effects on the safety are selected by result of the sensitivity analysis. And then, the dynamic analysis when the suspension element is broken is performed using ADAMS/Rail. The 30km track between Pungsegyo and Biryong tunnel in Gyeongbu High-speed Line was used at the dynamic analysis. The estimated value is found by using the normal method of UIC 518OR. The estimated values on the normal/fault state and the limit values of UIC 518OR are compared. Finally, the safety of the next generation high-speed train is verified.

  • PDF

하이브리드 자동차용 고압 케이블의 온도 특성에 관한 연구 (A Study on the Temperature Characteristics of High Voltage Power Cable for Hybrid Electric Vehicle)

  • 이기연;김동우;김동욱;길형준;김향곤;최충석
    • 전기학회논문지P
    • /
    • 제57권3호
    • /
    • pp.338-342
    • /
    • 2008
  • Hybrid Electric Vehicle(HEV) is driven by an internal-combustion engine and an electric motor. It is a combination of an internal-combustion engine and several electrical equipments which use a high voltage battery, an electric motors, an inverter and others. But there is not any separate detailed enforcement regulations for high voltage electric appliances in the existing vehicle-related safety standards. So, test standards suggestion as well as test technique development need to be done for ensuring electrical safety, for an electric motor, a high voltage battery, a(n) inverter/converter and an electric power transmission units and other equipments to ensure the safety of high voltage electric appliances which is the HEV key electrical component. In this paper, We are to provide helpful data to support test technique development and test standard establishment for HEV design and electrical safety security by the following methods; by measuring the voltage, the electric current, and the frequency of HEV, by analyzing electrical characteristics of high voltage electric appliances, and by analyzing temperature characteristics of the electrical current among the analyzed electrical characteristics by thermal imagining cameras.

고강도 콘크리트 구조부재의 폭렬 특성에 관한 실험적 연구 (An Experimental Study on the Explosive Spalling Properties of High Strength Concrete Structure Member)

  • 김흥열;전현규
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.421-424
    • /
    • 2006
  • This study, in order for perceiving the mechanical attribute followed by the explosive spalling of high strength concrete material under high temperature and evaluating capacity of endurance of material, targets understanding capacity of endurance of material such as explosive spalling in high temperature, temperature by thickness of clothing, transformation extent, transformation speed and displacement, stocking the maximum load based on the Allowable Stress Design Method. As a result of experimenting the explosive spalling attribute of high strength concrete material, the one possibly causing serious damage is the 50 MPa concrete. In all aspects of 60 MPa concrete, explosive spalling happens. Especially, it is hazardous enough to reveal all the iron bar. All explosive spalling is intensively concentrated on the surface of concrete for the first $5{\sim}25$ minutes, which urges for the explosive spalling protection action. As a result of evaluating the structural safety by the transformation of high strength concrete, while beam assures the fire safety meeting regulation, 60 MPa shows the dramatic increase of transformation, which only counts 84% of safety. In a column, both the concrete exclusion and excessive explosive spalling are concentrated upper part of column, which brings about the dramatic transformation, so it only meets the 50% of safety regulation. Likewise, in 80, 100 MPa concrete which was never experimented considering the condition of domestic structural endurance stocking devices, the faster collapse is expected.

  • PDF

Large-eddy simulation on gas mixing induced by the high-buoyancy flow in the CIGMAfacility

  • Satoshi Abe;Yasuteru Sibamoto
    • Nuclear Engineering and Technology
    • /
    • 제55권5호
    • /
    • pp.1742-1756
    • /
    • 2023
  • The hydrogen behavior in a nuclear containment vessel is a significant issue when discussing the potential of hydrogen combustion during a severe accident. After the Fukushima-Daiichi accident in Japan, we have investigated in-depth the hydrogen transport mechanisms by utilizing experimental and numerical approaches. Computational fluid dynamics is a powerful tool for better understanding the transport behavior of gas mixtures, including hydrogen. This paper describes a Large-eddy simulation of gas mixing driven by a high-buoyancy flow. We focused on the interaction behavior of heat and mass transfers driven by the horizontal high-buoyant flow during density stratification. For validation, the experimental data of the Containment InteGral effects Measurement Apparatus (CIGMA) facility were used. With a high-power heater for the gas-injection line in the CIGMA facility, a high-temperature flow of approximately 390 ℃ was injected into the test vessel. By using the CIGMA facility, we can extend the experimental data to the high-temperature region. The phenomenological discussion in this paper helps understand the heat and mass transfer induced by the high-buoyancy flow in the containment vessel during a severe accident.