• Title/Summary/Keyword: high rise buildings

Search Result 1,539, Processing Time 0.028 seconds

A Study on the Time-periodic Characteristics of Multi-Family Housing in Cheongju (청주지역 공동주택의 시기별 특성에 관한 연구)

  • Han, Jo-Dong;Rhee, Kang-Hoon
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.3 no.3
    • /
    • pp.57-67
    • /
    • 2001
  • The evolution of multi-family housing in Cheongju can be divided by four stages which are a introduction period from 1972 to 1980, a popularization period from 1981 to 1989, a expansion period from 1990 to 1997, and a stagnation period after 1998. In the introduction period, the multi-family housings were mainly low-rise buildings because a government policy which focused on extension of the apartments for the low-income influenced multi-family housing constructions. During the popularization period, the multi-family housings were still low-rise but houses in various sizes were introduced. That was because the Housing Site Developments were started and private companies' participations followed them increasingly. As a result of vigorous participations of private companies and massive developments of housing sites, the multi-family housings in the expansion period started to show constructions of complex and trends of high density and high rising. Finally, in the stagnation period, a rate of the supply of the small houses, whose size was below $60m^2$ of exclusive, area was increased and extreme high-rise apartments emerged. High rising and density were the mainstream of the construction concepts. During this period, the growth of multi-family housing marked low. The reason was that a downturn in economy led private companies to shrink their constructions.

  • PDF

System Performance with Variation of Outdoor Unit Layouts at Building Re-entrants

  • Koh, Jae-Yoon;Lee, Hyun-Gu;Zhai, John
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.16 no.1
    • /
    • pp.15-21
    • /
    • 2008
  • Air-cooled split-type air conditioners (AC) are very popular in high-rise residential and commercial buildings in Korea. The performance of such AC systems varies significantly with system characteristics and environmental conditions. Particularly, the outdoor condensing unit of the system, if poorly cooled due to high density of AC distribution and restricted outdoor space, will result in large decrease of cooling efficiency and increase of electrical energy consumption and may further jeopardize the system reliability. This paper presents a numerical analysis on the thermal and energy performance of a group of air-cooled air conditioners installed at a courtyard of a high-rise building. The study introduces a series of new energy performance indices to assess the group performance of the AC condensers with different outdoor unit layouts. The results not only indicate the COP of the systems, but also quantify the system capacity and energy consumption. The evaluation method and indices developed are useful for guiding the design of the distribution plan of the AC units at building re-entrants.

A Study on the Economic Evaluation Model of Splice of Reinforcement Bar(SD500) (초고강도 철근이음의 경제성 평가모델 개발에 관한 연구)

  • Kim, Jae-Yeob;Kim, Dae-Won
    • Journal of the Korea Institute of Building Construction
    • /
    • v.8 no.1
    • /
    • pp.71-76
    • /
    • 2008
  • Recently, the high-rise apartment housings have become a prototype of the urban residential dwelling in Korea and the numbers of one have steadily been increasing. According to this trend, the strength of the construction materials is also fortified to assure the stability and durability of the buildings. Specially, Re-bar of SD500 type is largely used at the construction sites of high-rise building. This study analyzes the current usage of SD500 high-strength re-bar at domestic construction sites. Through the result of this analysis, we develop Economic Evaluation Model that measure economic efficiency of lap splice and coupler splice, which are most commonly used in connection SD500. The evaluation method was applied to construction sites in Seoul in December 2006, and the result revealed that coupler splice is relatively superior in terms of cost efficiency when the re-bar diameter is longer and the concrete strength is lower.

An experimental study on the quality variation of concrete caused by high pressure in pumping. (펌프압송 시 압력변화에 따른 콘크리트 물성변화 규명을 위한 실험적 연구)

  • Jeon, Seong-Sik;Kim, Sang-Heon;Ji, Suk-Won;Seo, Chee-Ho;Kim, Ook-Jong;Lee, Do-Bum
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.613-616
    • /
    • 2006
  • Development of construction technology and various condition is realized by high-rise buildings and so concrete placing by pressure pump has been developed in with the trend of large-size and high-rise building. So, it is judged that reservation of the basic data for standard of quality control standard Code by the prediction and this to a quality change exact here is urgent. In this study it is going to carry out experimental research for a physical-properties change searching examination of the concrete by the after pressure change factor which does not become hard by the pumping method of construction.

  • PDF

Evaluation on the Characteristics of Noise Reduction according to the Tunnel Section Shape (방음터널 단면형상에 따른 소음저감 특성 평가 - 터널 내부소음을 중심으로 -)

  • 이원열;김하근;오양기;주문기;조성환
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.1014-1019
    • /
    • 2003
  • It seems inevitable for residential buildings to be high-rise and allocated near traffic roads due to the overcrowding in urban area. Acoustic environment in those area has been seriously deteriorated by the increase of traffic vehicles. Commonly used sound barriers have a limitation in controlling noise due to diffraction noise of sound barrier. Hence sound barrier is not effective to attenuate noise especially for the residential units in high level. This work aims at evaluating noise reduction according to the tunnel section shape by using 1/5 scale model. We carried out a number of field measurements for 1/5 scale model of Noise Barrier Tunnel with various sectional shape. The results from predictions and the measurement show generally good agreement.

  • PDF

Drying Shrinkage and Carbonation of High Strength Lightweight Self-Compacting Concrete (고강도 경량 자기충전콘크리트의 건조수축 및 중성화 특성)

  • Choi, Wook;Choi, Yun-Wang;Kim, Yong-Jic;Kang, Hyun-Jin;Cho, Sun-Kyu
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05b
    • /
    • pp.77-80
    • /
    • 2005
  • Lightweight concrete is known for its advantage of reducing the self-weight of the structures, reducing the areas of sectional members as well as making the construction convenient. Thus the construction cost can be saved when applied to structures such as long-span bridge and high rise buildings. However, the lightweight concrete requires specific mix design method that is quite different from the typical concrete, since using the typical mix method would give rise the material segregation as well as lower the strength by the reduced weight of the aggregate. In order to avoid such problems, it is recommended to apply the mix design method of self-compacting concrete for the lightweight concrete. Experimental tests were performed as such compressive strength, dry shrinkage and carbonation of high strength lightweight self-compacting concrete.

  • PDF

A Study on Sunshine Environment with Different Distance between Buildings (인동간격에 따른 일조환경에 대한 연구)

  • 최용석;최지혜;김용식
    • Journal of the Korean housing association
    • /
    • v.15 no.2
    • /
    • pp.55-62
    • /
    • 2004
  • Apartment design in residential Area is restricted by building distance limit code. Building distance limit decreases gradually to the 0.8H(height), and residential area has 250% site area ratio by building code, so site using has become efficient. In this study, examine the relationship between present building distance limit and right of daylighting environment by computer simulation. As well, high-rise residential officetel and multipurpose residential building becomes increase in commercial non-residential area. In the domestic, residential type multipurpose building made at the business area or central business area has 400∼800% site area ratio by building code. However, at a dweller's point of view, there are much lacks of environmental consideration to provide suitable daylighting environment. And, POE: Post Occupancy Evaluation is not completed yet. In this study, however, progress architectural environment prediction, basis by right of daylighting, and examine the possibility of daylighting by architectural distance limit code in residental area and by high-rise, high-density residential building in non-residental downtown area.

Application of Hybrid Structural System Using Coupled Vibration Control Structure and Seismic Isolated Structure in High-Rise Building

  • Nakajima, Shunsuke
    • International Journal of High-Rise Buildings
    • /
    • v.10 no.3
    • /
    • pp.219-227
    • /
    • 2021
  • This building is a forty-eight story, 170 meters high multiple dwelling house with Dual Frame System (DFS), a coupled vibration system connecting two independent structures with hydraulic dampers. Generation of large deformation between two structures during earthquakes contributes to make the hydraulic dampers effective. To improve the aseismic performance more, this building adopts DFS hybrid system that consists of DFS and base isolation system. About typical floors, columns and beams are constructed with LRV precast concrete method that shorten the construction period greatly by integrating column-beam joints in column members.

A Study on Egress Algorithm for High-rise Buildings Using Egress Simulation (피난시뮬레이션을 이용한 초고층건물의 피난 알고리즘 연구)

  • Kim, Won Kook;Seo, Dong Hyun
    • Fire Science and Engineering
    • /
    • v.32 no.1
    • /
    • pp.33-39
    • /
    • 2018
  • When the fire in the high-rise building was not extinguished in its early stage and propagated over its origin, safe egress becomes one of the most important factor to minimize the casualties. Recently fire protection for high-rise building has been reinforced after experiencing the series of disastrous fires. But, we still find many high-rise buildings do not comply with those reinforcement. And also there is a possibility of failure of reinforced fire protection system. Under these situation safe egress guide would be the final layer of protection. In this study existing egress methods were identified and evaluated. According the result of study, priority in egress should be given to the tenants on the floor of fire origin and floors exposed to the risk of fire. Then, the rest of the tenants can be evacuated simultaneously. Floors exposed in fire risk shall be determined by fire tests and/or fire simulations. But, the result of fire monitoring shall override preliminary estimations. Egress time for each algorithm was estimated by egress simulation and the result was compared. There was a little difference in egress time between total egress and phased egress, and a big difference between using stairs only and using elevators and stairs together. to a constant thickness between layers constituting a firefighter's protective clothing should be considered in the future.

Design and Performance Analysis of Real-Time Hybrid Position Tracking Service System using IEEE 802.15.4/4a in the Multi-Floor Building (복합환경에서 IEEE 802.15.4/4a를 이용한 하이브리드 실시간 위치추적 서비스 시스템 설계 및 성능분석)

  • Kim, Myung-Hwan;Chung, Yeong-Jee
    • Journal of Information Technology Services
    • /
    • v.10 no.1
    • /
    • pp.105-116
    • /
    • 2011
  • With recent spotlight on the, uniquitous computing technology, the need for object of indentification and location infrastructure has increased. Such GPS technolgy must utilize IEEE 802.15.4 Zigbee used for existing wireless sensor network infra as a basice element for user's context-awareness in a uniquitous environement, for effectiveness.Such real-time GPS service is provided in the internal environment where the user would actually are and most high-rise buildlings apply. Underthe assumption, the real-time GPS technology is seperated by each floor, and signals do not get transmitted to other floors, the application on one floor within the high-rise buildling was conducted. This study intends to suggest a floor detection algorithm using IEE 802.15.3/Zigbee's RSSI which supports the accuracy within a couple of meters for the user's the movement between the floors in high-rise buildings in a complex environment. It proposes an floor detection algorithm using IEEE 802.15.4/Zigbee's RSSI which provides accuracy within a radius of few meters for the users movement between the floors for real-time location tracking within high-rise building in a cmoplex environment. Furthermore, for more accurate real-time location tracking, it suggests an algorithm for real-time location tracking using IEEE 802.15.4a/Zigbee's CSS technology based on triangulation. Based on the suggested algorithm, it designs a hybrid real-time location tracking service system in a high-rise buildling and test its functions.