Application of Hybrid Structural System Using Coupled Vibration Control Structure and Seismic Isolated Structure in High-Rise Building

  • Published : 2021.09.15

Abstract

This building is a forty-eight story, 170 meters high multiple dwelling house with Dual Frame System (DFS), a coupled vibration system connecting two independent structures with hydraulic dampers. Generation of large deformation between two structures during earthquakes contributes to make the hydraulic dampers effective. To improve the aseismic performance more, this building adopts DFS hybrid system that consists of DFS and base isolation system. About typical floors, columns and beams are constructed with LRV precast concrete method that shorten the construction period greatly by integrating column-beam joints in column members.

Keywords

References

  1. Fukumoto, Y., Nishimura, K., and Wada, Y. (2008). Response Control Effect of Hi-Rised Reinforced Concrete Building Using Coupled Vibration Control Structure. AIJ J. Technol. Des, 14(28), 417-422. https://doi.org/10.3130/aijt.14.417
  2. Fujiu, N., and Sugimoto, K. (2009). Development of Precast System for Constructing High-rise RC Buildings in Short Term. Concrete Journal, 47(8), 25-32. https://doi.org/10.3151/coj.47.8_25