• Title/Summary/Keyword: high rise buildings

Search Result 1,539, Processing Time 0.026 seconds

Considerations of Sustainable High-rise Building Design in Different Climate Zones of China

  • Wan, Kevin K.W.;Chan, Man-Him;Cheng, Vincent S.Y.
    • International Journal of High-Rise Buildings
    • /
    • v.1 no.4
    • /
    • pp.301-310
    • /
    • 2012
  • Buildings, energy and the environment are key issues that the building professions and energy policy makers have to address, especially in the context of sustainable development. With more tall buildings constructed in China, the impact on energy consumption and carbon emission would be great from buildings (2% increase of carbon dioxide annually between 1971 and 2004). The imperative was to investigate the building energy performance of high-rise in different climate zones and identify the key design parameters that impose significantly influence on energy performance in sustainable building design. Design implications on glazing performance, sizing of the ventilation fans, renewable energy application on high-rise building design are addressed. Combination of effective sustainable building design strategies (e.g., building envelope improvement, daylight harvesting, advanced lighting design, displacement ventilation, chilled ceiling etc.) could contribute more than 25% of the total building energy consumption compared to the international building energy code.

Seismic Performance and Vibration Control of Urban Over-track High-rise Buildings

  • Ying, Zhou;Rui, Wang;Zengde, Zhang
    • International Journal of High-Rise Buildings
    • /
    • v.11 no.3
    • /
    • pp.207-219
    • /
    • 2022
  • During the structural design of urban over-track high-rise buildings, two problems are most likely encountered: the abrupt change of story stiffness between the podium and the upper towers, as well as the demand for train-induced vibration control. Traditional earthquake-resistant structures have to be particularly designed with transfer stories to meet the requirement of seismic control under earthquakes, and thus horizontal seismic isolation techniques are recommended to solve the transfer problem. The function of mitigating the vertical subway-induced vibration can be integrated into the isolation system including thick rubber bearings and 3D composite vibration control devices. Engineering project cases are presented in this paper for a more comprehensive understanding of the engineering practice and research frontiers of urban over-track high-rise buildings in China.

Seismic Retrofit of High-Rise Building with Deformation-Dependent Oil Dampers against Long-Period Ground Motions

  • Aono, Hideshi;Hosozawa, Osamu;Shinozaki, Yozo;Kimura, Yuichi
    • International Journal of High-Rise Buildings
    • /
    • v.5 no.3
    • /
    • pp.177-186
    • /
    • 2016
  • Along the subduction-zone of the western Japanese islands, large earthquakes are expected occur around the middle of this century, and long-period ground motions will reach major urban areas, shaking high-rise buildings violently. Since some old high-rise buildings were designed without considering long-period ground motions, reinforcing such buildings is an important issue. An effective method to reinforce existing high-rise buildings is installing additional dampers. However, a problem with ordinary dampers is that they require reinforcement of surrounding columns and girders to support large reaction forces generated during earthquake ground motion. To solve this problem, a deformation-dependent oil damper was developed. The most attractive feature of this damper is to reduce the damping force at the moment when the frame deformation comes close to its maximum value. Due to this feature, the reinforcement of columns, girders, and foundations are no longer required. The authors applied seismic retrofitting with a deformation-dependent oil damper to an existing 54-story office building (Shinjuku Center Building) located in Shinjuku ward, Tokyo, in 2009 to suppress vibration under the long period earthquake ground motions. The seismic responses were observed in the 2011 Tohoku Earthquake, and it is clarified that the damping ratio was higher and the response lower by 20% as compared to the building without dampers.

A Simulation Method for Considering the Outdoor Wind-Pressure in Calculation of Indoor Air-Flow in High-Rise Buildings (건물 내 공기유동 해석에 외부 바람이 미치는 영향의 분석)

  • Kim, Dae-Young;Song, Doo-Sam
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.2
    • /
    • pp.55-62
    • /
    • 2016
  • The air flows in building caused by thermal buoyancy, known as the stack effect, have a pronounced influence on both the indoor environment (thermal environment, noise, draught and contaminant diffusion) and energy needs in high-rise buildings. Prior studies for airflow in high-rise buildings were focused on the degree of stack effect and countermeasures. The wind pressure was neglected during the calculation of the indoor airflow in high-rise buildings to clarify the effect of thermal buoyancy in previous studies. However, wind is an important driving force of indoor airflows in buildings with the stack effect. In this study, the effect of wind pressure on indoor airflow in high-rise building when the stack effect is dominant in winter was analyzed. In this paper, methods that involved considering the wind pressure in airflow network simulation were analyzed.

Review on Prior Evaluation for Terrorism Risk of High-rise Buildings (초고층건축물의 테러 위험도 사전평가에 관한 연구)

  • Seong, Bin;Lee, Yoon-Ho
    • Korean Security Journal
    • /
    • no.36
    • /
    • pp.293-316
    • /
    • 2013
  • Today's high-rise buildings are increasing concern about the safety and evacuation of people related to the fire and threat from outside. Terrorism breaking out in high-rise buildings, a symbol of the national economy results in a number of casualties, economic loss, social fear and damage to national status. That's why high-rise building has also emerged as a target of major terrorist attacks, compared to other types of buildings. We have 54 high-rise buildings in 15 regions over the country. The Ministry of Land, Infrastructure and Transport and Seoul Metropolitan Government have offered the guidelines to prevent terrorist attacks toward high-rise buildings. Since the 9/11 terrorist attacks, the U.S. Federal Emergency Management Agency (FEMA) has developed and taken advantage of the Risk Management Manual Series. According to this manual, pre-assessment is conducted for the prevention of terrorism and particularly in FEMA 455, risk of the surrounding areas, vulnerability, possibility from terrorist attacks are checked. After the check, experts classify the risk of terrorist attacks toward the high-rise buildings and according to the risk classification, architects, security experts and structure engineers can carry out terrorism prevention program for high-rise buildings. The U.K. NaCTSO has also offered the terrorism prevention guidelines. Therefore, the Ministry of Land, Infrastructure and Transport and Seoul Metropolitan Government should make more concrete guidelines for high-rise buildings such as what U.S. FEMA and U.K. NaCTSO implement, including prior evaluation technique for terrorism risk.

  • PDF

Study on the Eco-friendly Design Methods of the High-rise Residential-Commercial Building -Based on a work of Ken yeang, Bishopsgate Towers- (초고층 주상복합건축물의 친환경적 디자인 방법에 대한 연구 -켄 양의 Bishopsgate Towers를 중심으로-)

  • Kim, Sun-Ok;Oh, Se-Gyu
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2005.11a
    • /
    • pp.283-286
    • /
    • 2005
  • In the modern city in which the high-density and complex land use is needed, high-rise residential-commercial buildings appeared as a scheme to arrange a metropolitan residence with multiple high-techs and to induce activation of the city with leading the settled population to flow into the city. And the need of the times is to actively apply the eco-friendly notion to the architecture. In this study, the works of Ken Yeang who is regarded as an eco-friendly architect to make high-rise residential-commercial buildings ecological should be focused on with analyses of eco-friendly characteristics in inside, intersection between inside and outside, and outside of his works. The result o the study would be the suggestion to design eco-friendly high-rise buildings which make the city rise in quality.

  • PDF

A Study on the Efficiency of Evacuation Exterior Stairs in High-rise Buildings (고층빌딩에서 옥외피난계단의 효용성에 관한 연구)

  • Choi, Kyu-Chool
    • Fire Science and Engineering
    • /
    • v.23 no.1
    • /
    • pp.63-69
    • /
    • 2009
  • Article 36 of the Building Code Enforcement Ordinance requires that an exterior evacuation stairs be installed for the buildings of three stories and over with cultural facilities or gathering places which have over $1,000\;m^2$ floor area of public performance halls or recreational facilities. The concentration of population together with the increase of high-rise buildings in cities call for various precautionary measures to be taken against human disasters. For the past ten years high-rise buildings showed 85% of increase, marking a steep rise. This increase of high-rise buildings may lead to human disasters in urban areas and, in case of fire breakout, may cause great loss of human lives and property damages. The most difficult fire-fighting activities in high-rise building fires are those of evacuation. Because smoke spreads through the upper floors, the securement of evacuation route in high-rise buildings may be the only way to minimize loss of lives. In high-rise buildings exterior escape stairs are necessary because it is difficult to secure evacuation route with only direct stairs or interior stairs. The Building Code now in force provides insignificant coverage on the exterior evacuation route installment and therefore becomes an inadequate means for evacuation route securement in high-rise building fires. To compensate for this inadequacy the Building Code should be revised to include a mandatory clause that an exterior evacuation stairs be established for the buildings of ten stories and over which can be categorized into high-rise building group.

The Wind Pressure Evaluation on Exterior Wall for High-rise Buildings (고층구조물 외벽의 내풍설계를 위한 풍압평가)

  • Lee Kyu-Ung;Kim Jae-Ung
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2005.04a
    • /
    • pp.63-70
    • /
    • 2005
  • For using narrow site effectively, recently constructions of high-rise buildings have been increased. High-rise buildings are mainly governed by wind loads. Since wind flow Is vaned irregularly, the experimental method such as wind tunnel test is used to evaluate real wind loads. In this study, it is intended to estimate design wind pressure and amounts of material of cladding by AIK recommendations and wind tunnel test. Also, this study includes the investigation of reliability, suitability and economical efficiency in design of cladding of buildings by AIK recommendations and wind tunnel test by comparing and examining various results. Finally, it is concluded that not only AIK recommendations but also wind tunnel test should be considered to get the reasonable wind pressure acting on the cladding of high-rise buildings.

  • PDF

Rapid Diagnosis Systems Using Accelerometers in Seismic Damage of Tall Buildings

  • Tsuchihashi, Toru;Yasuda, Masaharu
    • International Journal of High-Rise Buildings
    • /
    • v.6 no.3
    • /
    • pp.207-216
    • /
    • 2017
  • Installing accelerometers in a building is an effective way to know how the building shakes when an earthquake happens. In this paper, we will introduce an example of an analysis that captures the acceleration reduction effect of the vibration damping device using data observed by the accelerometer at Roppongi Hills Mori Tower in Minato-ku, Tokyo, during the Great East Japan Earthquake on March 11, 2011. Moreover, as the latest effort, from the standpoint of a developer who builds and operates a number of high-rise buildings in Japan, where frequent earthquakes are experienced, a system for real-time processing of accelerometer data was developed to instantly diagnose the degree of damage to high-rise buildings, and the actual system of earthquake damage health monitoring is discussed. This system is currently in operation in twelve high-rise buildings including Roppongi Hills Mori Tower.