• Title/Summary/Keyword: high pressure $CO_2$

Search Result 989, Processing Time 0.026 seconds

TRAO Key Science Program: mapping Turbulent properties In star-forming MolEcular clouds down to the Sonic scale (TIMES)

  • Yun, Hyeong-Sik;Lee, Jeong-Eun;Choi, Yunhee;Lee, Seokho;Baek, Giseon;Lee, Yong-Hee;Choi, Minho;Kang, Hyunwoo;Tatematsu, Ken'ichi;Gaches, Brandt A.L.;Heyer, Mark H.;Evans, Neal J. II;Offner, Stella S.R.;Yang, Yao-Lun
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.43 no.1
    • /
    • pp.66.1-66.1
    • /
    • 2018
  • Turbulence is a phenomenon which largely determines the density and velocity fields in molecular clouds. Turbulence can produce density fluctuation which triggers a gravitational collapse, and it can also produce a non-thermal pressure against gravity. Therefore, turbulence controls the mode and tempo of star formation. However, despite many years of study, the properties of turbulence remain poorly understood. As part of the Taeduk Radio Astronomy Observatory (TRAO) Key Science Program (KSP), "apping Turbulent properties In star-forming MolEcular clouds down to the Sonic scale (TIMES; PI: Jeong-Eun Lee)", we have mapped two star-forming clouds, the Orion A and the ${\rho}$ Ophiuchus molecular clouds, in 3 sets of lines (13CO 1-0/C18O 1-0, HCN 1-0/HCO+ 1-0, and CS 2-1/N2H+ 1-0) using the TRAO 14-m telescope. We aim to map entire clouds with a high-velocity resolution (~0.05 km/s) to compare turbulent properties between two different star-forming environments. We will present the preliminary results using a statistical method, Principal Component Analysis (PCA), that is a useful tool to represent turbulent power spectrum.

  • PDF

A Study on Growth of the Green Leaf Lettuce Depends on PPFD and Light Quality of LED Lighting Source for Growing Plant (식물재배용 LED 광원의 광질과 PPFD에 따른 청치마상추의 성장에 관한 연구)

  • Yang, Jun-Hyuk;Choi, Won-Ho;Park, Noh-Joon;Park, Dae-Hee
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.2
    • /
    • pp.142-147
    • /
    • 2015
  • The artificial light sources for growth of plant are usually high-pressure sodium lamp, metal haloids lamp, and fluorescent light; however, these light sources have relatively weaker Red and Blue lights that are necessary for growth of plants. Especially the effect of Photosynthetic Photon Flux Density (PPFD) is pointed out as the weakness. Meanwhile, LED light source can be selected by specific wavelength to greatly improve the effect of PPFD. In this regard, this paper aims to investigate the promotion of plant growth by measuring photosynthetic photon flux density (hereafter referred to as PPFD) according to changes in light quality of the LED light sources. Towards this end, LED light sources for plant growth were produced with 4 kinds of mono-chromatic lights and 6 kinds of combined lights by mixing red, blue, green and white lights. A comparative analysis was conducted to investigate the effects of optical properties and PPFD on plants (green leaf lettuce) using the produced light sources. The results monochromatic light has fastest growth rate, but plant growth conditions have poor. This being so, mixed light is suitable for the green leaf lettuce.

A Study on Performance Improvement of a PHC-W Pile for PHC-W Retaining Wall (PHC-W 흙막이용 PHC-W말뚝의 성능개선에 관한 연구)

  • Kim, Chae Min;Kim, Sung Su;Jeon, Byeong Han;Choi, Yongkyu
    • Journal of the Korean Geotechnical Society
    • /
    • v.33 no.2
    • /
    • pp.27-34
    • /
    • 2017
  • Various earth retaining wall methods were used on the domestic construction sites and a cast in place pile (C.I.P) method was mostly applied at deep excavation. Because of a lot of shortcomings in the C.I.P method, a new method using PHC-W earth retaining wall was developed. The earth retaining wall method using PHC-W piles has a lot of advantages including that it is safer than other earth retaining wall methods due to uniform quality and high rigidity. PHC-W was designed to effectively resist lateral earth pressure by alternating cross section of PHC pile. And increment of bending moment and shear strength were verified through KS F 4306 tests, and were increased by 42% and 98% more than KS standards.

Application of plasma lighting for growth and flowering of tomato plants

  • Park, Kyoung Sub;Kim, Sung Kyeom;Lee, Sang Gyu;Lee, Hee Ju;Kwon, Joon Kook
    • Horticulture, Environment, and Biotechnology : HEB
    • /
    • v.59 no.6
    • /
    • pp.827-833
    • /
    • 2018
  • Plasma lighting systems have been engineered to simulate sunlight. The objective of this study was to determine the effects of plasma lighting on tomato plant growth, photosynthetic characteristics, flowering rate, and physiological disorders. Tomato plants were grown in growth chambers at air temperatures of $25/23^{\circ}C$ (light/dark period), in a $16h\;day^{-1}$ light period provided by four different light sources: 1 kW and 700 W sulfur plasma lights (1 SPL and 0.7 SPL), 1 kW indium bromide plasma light, and 700 W high pressure sodium lamp (0.7 HPS) as a control. The totaldry weight and leaf area at 0.7 SPL were approximately 1.2 and 1.3 times greater, respectively, than that of 0.7 HPS at the 62 days after sowing (DAS). The maximum light assimilation rate was observed at 1 SPL at the 73 DAS. In addition, the light compensation and saturation points of the plants treated with plasma lighting were 98.5% higher compared with HPS. Those differences appeared to be related to more efficient light interception, provided by the SPL spectrum. The percentage of flowering at 0.7 SPL was 30.5%, which was higher than that at 0.7 HPS; however, there were some instances of severe blossom end rot. Results indicate that plasma lighting promotes tomato growth, flowering, and photosynthesis. Therefore, a plasma lighting system may be a valuable supplemental light source in a greenhouse or plant factory.

Evaluation of measuring accuracy of body position sensor device for posture correction (자세교정을 위한 체위변환 감지 센서 디바이스의 정확성 평가)

  • Choi, Jung-Hyeon;Park, Jun-Ho;Kang, Min-Ho;Seo, Jae-Yong;Kim, Soo-Chan
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.22 no.3
    • /
    • pp.128-133
    • /
    • 2021
  • Recently Recently, the incidence of spinal diseases due to poor posture among students and office workers is increasing, and various studies have been conducted to help maintain correct posture. In previous studies, a membrane sensor or a pressure sensor was placed on the seat cushion to see the weight bias, or a sensor that restrained the user was attached to measure the position change. In our previous study, we developed a sensor device which can be easily attached to the body with an adhesive gel sheet and that measures and outputs the user's posture and body position in real time, but it has a limitation in the accuracy of the sensor value. In this study, a study was conducted to improve the performance of the position conversion sensor device and quantitatively evaluate the accuracy of the angle conversion measurement value, and a high accuracy with 2.53% of error rate was confirmed. In future research, it is considered that additional research targeting actual users is needed by diversifying posture correction training contents with multimedia elements added.

A Study on the Removal of Aromatic Compounds from Soil and Zeolite Using Supercritical Carbon Dioxide (초임계 이산화탄소를 이용한 토양과 제올라이트중의 방향족 화합물 제거에 관한 연구)

  • Bae, Won;Shin, Bohyun;Kang, Hoseok;Kim, Hwayong
    • Clean Technology
    • /
    • v.9 no.4
    • /
    • pp.197-206
    • /
    • 2003
  • We performed removal of aromatic compounds, benzene and toluene, from soil and zeolite using supercritical carbon dioxide. Extraction was performed at $50^{\circ}C$ and 27.7 MPa with changing the extent of pollutant concentration and the results were compared and analyzed. Experiments were carried out using flow method and high pressure extractor of 1.27 cm in diameter and 25cm in length was used. The pollutants were sampled every ten minutes and their concentrations were analyzed with GC/FID. As a result, highly contaminated sample followed solubility/elution model and slightly contaminated sample followed desorption/kinetics model. At the same condition benzene was extracted faster than toluene. In the case of zeolite, more time is required to extract pollutants than soil. This phenomena was due to high adsorption capacity of zeolite. In the case of highly contaminated soil, we could correlate experimental data using simple Brady's fixed bed extractor model. But in the case of slightly contaminated soil, that was governed with desorption/kinetics model, there was some errors.

  • PDF

Hydration Characteristics according to First Curing Condition in Solid Hydrated by Hydro-Thermal Synthesis Reaction (수열합성경화체의 1차 양생조건에 따른 수화특성)

  • Kim, Jin-Man;Jung, Eun-Hye;Park, Sun-Gyu
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.5
    • /
    • pp.543-548
    • /
    • 2008
  • Solid hydrated by hydro-thermal synthesis reaction is cured two times, the first curing is the steam curing at atmospheric pressure and the second one is a high-pressure steam curing, that is autoclaving. Steam curing is to acquire the proper strength for the resistance of treatment in the first curing process, it was not evaluated properly so far. Because of ignorance about curing, some engineers even think that the dry curing is better than the steam curing. The relation between compressive strength of solid hydrated by hydrothermal synthesis reaction and curing condition are presented in this paper. In order to investigate the effect of curing on the strength properties of specimen, the hydration behavior of solid hydrated by hydro-thermal synthesis reaction has been studied over curing condition using XRD, DT-TGA and porosimeter, SEM analysis technique. The results show that the specimens which are cured with blended method of dry and steam curing appear to have better strength properties than that of dry curing and steam curing. Also, there are significant difference of hydration behavior among curing condition in the solid hydrated by hydro-thermal synthesis reaction.

Skarn Evolution and Fe-(Cu) Mineralization at the Pocheon Deposit, Korea (한국 포천 광상의 스카른 진화과정 및 철(-동)광화작용)

  • Go, Ji-Su;Choi, Seon-Gyu;Kim, Chang Seong;Kim, Jong Wook;Seo, Jieun
    • Economic and Environmental Geology
    • /
    • v.47 no.4
    • /
    • pp.335-349
    • /
    • 2014
  • The Pocheon skarn deposit, located at the northwestern part of the Precambrian Gyeonggi massif in South Korea, occurs at the contact between the Cretaceous Myeongseongsan granite and the Precambrian carbonate rocks, and is also controlled by N-S-trending shear zone. The skarn distribution and mineralogy reflects both structural and lithological controls. Three types of skarn formations based on mineral assemblages in the Pocheon skarn exist; a sodiccalcic skarn and a magnesian skarn mainly developed in the dolostone, and a calcic skarn developed in the limestone. Iron mineralization occurs in the sodic-calcic and magnesian skarn zone, locally superimposed by copper mineralization during retrograde skarn stage. The sodic-calcic skarn is composed of acmite, diopside, albite, garnet, magnetite, maghemite, anhydrite, apatite, and sphene. Retrograde alteration consists of tremolite, phlogopite, epidote, sericite, gypum, chlorite, quartz, calcite, and sulfides. Magnesian skarn mainly consists of diopside and forsterite. Pyroxene and olivine are mainly altered to tremolite, with minor phlogopite, talc, and serpentine. The calcic skarn during prograde stage mainly consists of garnet, pyroxene and wollastonite. Retrograde alteration consists of epidote, vesuvianite, amphibole, biotite, magnetite, chlorite, quartz, calcite, and sulfides. Microprobe analyses indicate that the majority of the Pocheon skarn minerals are enriched by Na-Mg composition and have high $Fe^{3+}/Fe^{2+}$, $Mg^{2+}/Fe^{2+}$, and $Al^{3+}/Fe^{2+}$ ratios. Clinopyroxene is acmitic and diopsidic composition, whereas garnet is relatively grossular-rich. Amphiboles are largely of tremolite, pargasite, and magnesian hastingsite composition. The prograde anhydrous skarn assemblages formed at about $400^{\circ}{\sim}500^{\circ}C$ in a highly oxidized environment ($fO_2=10^{-23}{\sim}10^{-26}$) under a condition of about 0.5 kbar pressure and $X(CO_2)=0.10$. With increasing fluid/rock interaction during retrograde skarn, epidote, amphibole, sulfides and calcite formed as temperature decreased to approximately $250^{\circ}{\sim}400^{\circ}C$ at $X(CO_2)=0.10$.

The Side Effects and Correlates of OROS-Methylphenidate in the Treatment of Children and Adolescents with ADHD (ADHD 환자에 대한 OROS-Methylphenidate 약물치료의 부작용과 관련요인들에 대한 연구)

  • Kim, Jin-Sun;Kim, Bung-Nyun;Cho, Soo-Churl;Shin, Min-Sup;Yoo, Hee-Jeong;Kim, Jae-Won;Song, Dong-Ho;Shin, Dong-Won;Joung, Yoo-Sook;Cheon, Keun-Ah;Shin, Yee-Jin;Kim, Ye-Ni;Ha, Eun-Hye
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.21 no.2
    • /
    • pp.63-71
    • /
    • 2010
  • Objectives : The aim of this study was to investigate the effect of the clinical and demographic variables such as body weight, dosage, family history of attention-deficit hyperactivity disorder (ADHD), and psychiatric co-morbidity on the side-effects of OROS-Methylphenidate (OROS-MPH), and to evaluate the relationship between drug response and side effect severity. Methods : A total of 144 children (ages 6-18) with diagnosed ADHD were treated with OROS-MPH. Children were examined at baseline and after 1, 3, 6, 9, and 12 weeks of each treatment condition. The stimulant drug side effect rating scale (SERS), pulse rate, systolic blood pressure, diastolic blood pressure, and electrocardiogram (ECG) were evaluated to assess side effect profiles. Changes in these parameters from baseline were examined and analyzed. Results : Anorexia (30.95%) and insomnia (13.10%) were the most commonly reported side effects during this study. Insomnia and loss of appetite score increased at one week follow-up, but was sustained or decreased as treatment progressed. Small but significant increases in pulse rate and diastolic blood pressure were observed during treatment ; however, no clinically meaningful changes in ECG parameters were noted during the study. Low body weight, high dosage of OROS-MPH, and family history of ADHD were associated with cardiovascular side effect. In contrast, there was no significant relationship between OROS-MPH treatment response and the severity of side effect and no difference resulted between the responder and non-responder groups with respect to OROS-MPH dosage in the 12 weeks of follow-up. Conclusion : To the best of our knowledge, this study is the first Korean study to investigate comprehensive side effect profiles and their correlates in OROS-MPH treatment for ADHD children. OROS-MPH was well tolerated with no clinically significant side effects during the treatment period. In conclusion, low body weight, high dosage of OROSMPH, and family history of ADHD could be used as predictive factors in increasing pulse rate and blood pressure.

The Effect of Barrel Vibration Intensity to the Plating Thickness Distribution

  • Lee, Jun-Ho;Roselle D. Llido
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 1999.10a
    • /
    • pp.15-15
    • /
    • 1999
  • In chip plating, several parameters must be taken into consideration. Current density, solution concentration, pH, solution temperature, components volume, chip and media ratio, barrel geometrical shape were most likely found to have an effect to the process yields. The 3 types of barrels utilized in chip plating industry are the conventional rotating barrel. vibrational barrel (vibarrel), and the centrifugal type. Conventional rotating barrel is a close type and is commonly used. The components inside the barrel are circulated by the barrel's rotation at a horizontal axis. Process yield has known to have higher thickness deviation. The vibrational barrel is an open type which offers a wide exposure to electrolyte resulting to a stable thickness deviation. It rotates in a vertical axis coupled with multi-vibration action to facilitate mixed up and easy transportation of components, The centrifugal barrel has its plated work centrifugally compacted against the cathode ring for superior electrical contact with simultaneous rotary motion. This experiment has determined the effect of barrel vibration intensity to the plating thickness distribution. The procedures carried out in the experiment involved the overall plating process., cleaning, rinse, Nickel plating, Tin-Lead plating. Plating time was adjusted to meet the required specification. All other parameters were maintained constant. Two trials were performed to confirm the consistency of the result. The thickness data of the experiment conducted showed that the average mean value obtained from higher vibrational intensity is nearer to the standard mean. The distribution curve shown has a narrower specification limits and it has a reduced variation around the target value, Generally, intensity control in vi-barrel facilitates mixed up and easy transportation of components, However, it is desirable to maintain an optimum vibration intensity to prevent solution intrusion into the chips' internal electrode. A cathodic reaction can occur in the interface of the external and internal electrode. $2HD{\;}+{\;}e{\;}{\rightarrow}20H{\;}+{\;}H_2$ Hydrogen can penetrate into the body and create pressure which can cause cracks. At high intensity, the chip's motion becomes stronger, its contact between each other is delayed and so plating action is being controlled. However, the strong impact created by its collision can damage the external electrode's structure thereby resulting to bad plating condition. 1 lot of chip was divided into two equal partion. Each portion was loaded to the same barrel one after the other. Nickel plating and tin-lead plating was performed in the same station. Portion A maintained the normal barrel vibration intensity and portion B vibration intensity was increased two steps higher. All other parameters, current, solution condition were maintained constant. Generally, plating method find procedures were carried out in a best way to maintained the best plating condition. After plating, samples were taken out from each portion. molded and polished. Plating thickness was investigated for both. To check consistency of results. 2nd trial was done now using different lot of another characteristics.

  • PDF