Evaluation of measuring accuracy of body position sensor device for posture correction

자세교정을 위한 체위변환 감지 센서 디바이스의 정확성 평가

  • Received : 2021.09.16
  • Accepted : 2021.09.28
  • Published : 2021.09.30

Abstract

Recently Recently, the incidence of spinal diseases due to poor posture among students and office workers is increasing, and various studies have been conducted to help maintain correct posture. In previous studies, a membrane sensor or a pressure sensor was placed on the seat cushion to see the weight bias, or a sensor that restrained the user was attached to measure the position change. In our previous study, we developed a sensor device which can be easily attached to the body with an adhesive gel sheet and that measures and outputs the user's posture and body position in real time, but it has a limitation in the accuracy of the sensor value. In this study, a study was conducted to improve the performance of the position conversion sensor device and quantitatively evaluate the accuracy of the angle conversion measurement value, and a high accuracy with 2.53% of error rate was confirmed. In future research, it is considered that additional research targeting actual users is needed by diversifying posture correction training contents with multimedia elements added.

최근 학생 및 사무직 종사자의 자세 불량으로 인한 척추계 질환의 발병율이 증가하고 있으며, 바른 자세 유지를 돕기 위한 다양한 연구가 수행되었다. 기존 연구에서는 의자 방석부분에 멤브레인 센서 또는 압력센서를 배치하여 무게의 편중을 보거나, 사용자를 구속하는 센서를 부착하여 체위변환을 측정하였다. 본 연구자는 선행연구에서 점착성 겔시트로 간편히 몸에 부착할 수 있으며, 사용자의 자세 및 체위 변화를 실시간으로 측정하여 출력하는 센서 디바이스를 개발하였으나 센서값의 정확성에서 한계점을 보였다. 본 연구에서는 체위변환 센서 디바이스의 성능을 개선하고, 각도변환 측정값의 정확도를 정량적으로 평가하는 연구를 수행하였으며, 오차율 2.53%의 높은 정확도를 확인하였다. 향후 연구에서는 멀티미디어 요소가 추가된 자세교정 훈련 컨텐츠를 보다 다양화하여 실제 사용자를 대상으로 하는 추가 연구가 필요한 것으로 사료된다.

Keywords

Acknowledgement

이 연구는 2020년도 산업통상자원부 및 산업기술평가관리원(KEIT) 연구비 지원에 의한 연구임 [과제번호 : 20010234)

References

  1. M. S. Kim, J. Y. Seo, Y. H. Noh, D. U. Jeong, "Implementation of Cushion Type Posture Discrimination System Using FSR Sensor Array", Journal of the Institute of Convergence Signal Processing, Vol.20, No.2, pp.99-104, 2019
  2. M. K. Song, J. Y. Kong, "Effects of Sitting Habits and Physical Activity Levels on Spine and Pelvis Deformations in School Children", 2017
  3. S. Y. Ma, S. P. Hong, H. M. Shim, J. W. Kwon, S. M. Lee, "A study on Sitting Posture Recognition using Machine Learning", The Transactions of the Korean Institute of Electrical Engineers, Vo.65, No.9, pp.1557-1563, 2016 https://doi.org/10.5370/KIEE.2016.65.9.1557
  4. S. J. Moon, Y. S. Park, "The Design and Implementation of the Position Calibration System Using Sensor on u-WBAN", Journal of Korean Institute of The Intelligent System, Vo.20, No.2, pp.304-310, 2010 https://doi.org/10.5391/JKIIS.2010.20.2.304
  5. Y. J. Cho, K. S. Park, "Design and Development of the Multiple Kinect Sensor-based Exercise Pose Estimation System", Journal of The Korea Institute of Information and Communication Engineering, Vo.21, No.3, pp.558-567, 2017 https://doi.org/10.6109/JKIICE.2017.21.3.558
  6. Y. S. An, K. S. Kim, C. G. Song. "Posture guidance system using 3-axis accelerometer for scoliosis patient", Proceeding of the IEEK Conference, pp.396-398, 2009
  7. J. H. Choi, J. H. Park, J. Y. Seo, S. C. Kim, "Development of body position sensor device for posture correction training", Journal of the Institute of Covergence Signal Processing, Vol.21, No.2, pp.80-85, 2020