• Title/Summary/Keyword: high power

Search Result 23,183, Processing Time 0.051 seconds

A Three-Phase AC-DC High Step-up Converter for Microscale Wind-power Generation Systems

  • Yang, Lung-Sheng;Lin, Chia-Ching;Chang, En-Chih
    • Journal of Power Electronics
    • /
    • v.16 no.5
    • /
    • pp.1861-1868
    • /
    • 2016
  • In this paper, a three-phase AC-DC high step-up converter is developed for application to microscale wind-power generation systems. Such an AC-DC boost converter prossessess the property of the single-switch high step-up DC-DC structure. For power factor correction, the advanced half-stage converter is operated under the discontinuous conduction mode (DCM). Simulatanously, to achieve a high step-up voltage gain, the back half-stage functions in the continuous conduction mode (CCM). A high voltage gain can be obtained by use of an output-capacitor mass and a coupled inductor. Compared to the output voltage, the voltage stress is decreased on the switch. To lessen the conducting losses, a low rated voltage and small conductive resistance MOSFETs are adopted. In addition, the coupled inductor retrieves the leakage-inductor energy. The operation principle and steady-state behavior are analyzed, and a prototype hardware circuit is realized to verify the performance of the proposed converter.

Development of a High Power SONAR System Measuring Velocity by Using Two Gated Sinusoidal Signals (두 개의 정현 신호를 이용한 속도 측정용 고전력 쏘나 시스템 개발)

  • 장순석;안흥구;이제형
    • Journal of KSNVE
    • /
    • v.9 no.5
    • /
    • pp.1036-1041
    • /
    • 1999
  • This paper aims for the development of the high power sonar system for measuring the velocity of a moving object. The high power sonar system transmits two gated 190 kHz sinusoidal signals with 1.6 [ms] time interval to the moving object. Then the sonar system detects and calculates the changed time delay of the reflected ultrasonic signals in order to derive the velocity of the moving object. The transmission part uses a high power amplifier so that 250 W gated sinusoidal signals can be transmitted to the transmitter. 1M RAM is utilized for transmitting and storing of the ultrasonic signals. The time delay is calculted by the cross-correlation technique between the transmitted signals and the received signals. The measured value from the high power sonar system is compared with directly measured values by photo diodes. The result confirms the adjacency to 0.3% error.

  • PDF

Study on the High and High Voltage 35 kW, 50 kV Inverter Power Supply (대출력 고전압 35 kW, 50 kV 인버터 전원장치 개발에 관한 연구)

  • Son, Yoon-Gyu;Jang, Sung-Duck;Oh, Jong-Seok;Cho, Moo-Hyun
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.11
    • /
    • pp.628-634
    • /
    • 2002
  • A capacitor-charging power supply using high frequency inverter technology is strongly recommended for the charging section of the pulsed power supplies. A high frequency inverter swiching makes the overall system size small. The command-charging feature can guarantee the higher reliability of switching function. The protection circuit can be easily included in the system and the good regulation of charging voltage can be acieved by the feedback system. Several modules can be stacked to supply required output power and a failed module can be easily replaced. A 50-kV, 35-kW capacitor charging power supply is developed. In this paper the detailed design and test results of a prototype unit are presented.

Design of High Speed Motor for Surface Mounted Permanent Magnet (표면부착형 영구자석 초고속 회전기의 설계)

  • Song, Jae-Hong;Cha, Young-Bum;Yang, Hyun-Sub;Lee, Jeong-Jong;Hong, Jung-Pyo
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.939-941
    • /
    • 2003
  • High Speed permanent magnet machines are currently being developed for a number of applications including gas turbine power plants, air conditioning systems, machine tools, gas pumps, high performance vacuum pumps, flywheel energy storage systems, aircraft fuel pumps, and so on. Using a high-speed machine eliminates the necessity of the mechanical gearbox and could certainly increase the system efficiency and reduce the total cost. In addition, a high-speed machine has the advantage of small dimension and low weight, i.e. low weight to power and volume to power ratio. This paper presents a review of some important applications (mostly still under development) where high-speed machines arc used, highlighting the advantages of the technology in each case.

  • PDF

Implementation of a High Power Amplifier using Low Loss Radial Power Combiner and Water Cooling System (저 손실 레디알 전력 결합기와 수냉 시스템을 이용한 고전력 증폭기 구현)

  • Choi, Sung-Wook;Kim, Young
    • Journal of Advanced Navigation Technology
    • /
    • v.22 no.4
    • /
    • pp.319-324
    • /
    • 2018
  • In this paper, a high power amplifier using RF power solid-state semiconductor is implemented to overcome a problem of plasma generator which has the low efficiency, short life span, the difficult maintenance and the high-operation cost. This power amplifier consists of a radial combiner of low-loss and high power operation and the sixteen 300 W power amplifiers to obtain 3 kW output power for high power operation implemented in semiconductors at industrial scientific medical (ISM) band of 2.45 GHz. In addition, this amplifier overcomes the problem of heat generation due to high power by applying a water-cooled structure to the individual amplifiers. This power amplifier, which is made up of a small system, achieves 50% efficiency at the desired output.

The Characteristics on the Removal of Bacteria Using High Voltage and High Frequency Pulsed Power System (고압 고주파 펄스 파워 시스템을 이용한 세균 제거 특성)

  • Shim, Ji-Young;Kim, Mi-Jeong;Park, Je-Wook;Kim, Hee-Je
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1416-1417
    • /
    • 2007
  • The high frequency pulsed power system is widely available for use in high frequency generator applications. We designed and fabricated our own high frequency pulsed power system to obtain very sort pulse width and high peak value and investigated microbe removal characteristics using it. This paper introduces a simple high voltage high frequency pulsed power system for removing various bacteria caused by dirty water. This system include power supply circuit, switching MOSFET, and flyback converter. We can also control the switching using a PIC one chip microprocessor. As a result, we can obtain good removing characteristics of various bacteria by adjusting the charging voltage, the pulse repetition rate and the electrical field inducing time.

  • PDF

High-Efficiency and High-Power-Density 3-Level LLC Resonant Converter (고효율 및 고전력밀도 3-레벨 LLC 공진형 컨버터)

  • Gu, Hyun-Su;Kim, Hyo-Hoon;Han, Sang-Kyoo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.23 no.3
    • /
    • pp.153-160
    • /
    • 2018
  • Recent trends in high-power-density applications have highlighted the importance of designing power converters with high-frequency operation. However, conventional LLC resonant converters present limitations in terms of high-frequency driving due to switching losses during the turn-off period. Switching losses are caused by the overlap of the voltage and current during this period, and can be decreased by reducing the switch voltage. In turn, the switch voltage can be reduced through a series connection of four switches, and additional circuitry is essential for balancing the voltage of each switch. In this work, a three-level LLC resonant converter that can operate at high frequency is proposed by reducing switch losses and balancing the voltages of all switches with only one capacitor. The voltage-balancing principle of the proposed circuit can be extended to n-level converters, which further reduces the switch voltage stress. As a result, the proposed circuit is applicable to high-input applications. To confirm the validity of the proposed circuit, theoretical analysis and experimental verification results from a 350 W-rated prototype are presented.

Low Power Design on Heater and Cathode of Electron Gun for High Resolution CRT (고해상도 CRT용 전자총의 히터 및 캐소드 저전력 설계)

  • Kim Hack-Sung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.6
    • /
    • pp.618-625
    • /
    • 2005
  • This paper has achieved that an optimal design and experiments of heater and cathode of electron gun that serve to embody high current density in CRT display. For the high brightness, high resolution and larger size in CRT display, high current density of electron gun is indispensible. An Impregnation style cathode is used, and must heighten operating temperature of heater to get high current density for this, it is proportional hereupon and power dissipation increases. In this paper, to get low power cathode with high current density, There are produced and tested sample that differ lead type of heater, coating method, the pitch and number of winding of the first and second coiling in the heat emission area for the low power design of high current density cathode heater in this paper.

A Study On High Power Factor Sine Pulse Type Power Supply For Atmospheric Pressure Plasma Cleaning System with 3-Phase PFC Boost Converter (3상 PFC 부스트 컨버터를 채용한 상압플라즈마 세정기용 고역률 정형파 펄스 출력형 전원장치에 관한 연구)

  • Han, Hee-Min;Kim, Min-Young;Seo, Kwang-Duk;Kim, Joohn-Sheok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.1
    • /
    • pp.72-81
    • /
    • 2009
  • This paper presents quasi-resonant type high power factor ac power supply for atmospheric pressure plasma cleaning system adopting three phase PFC boost converter and it's control method. The presented ac power supply consists of single phase H-bridge inverter, step-up transformer for generating high voltage and three phase PFC boost converter for high power factor on source utility. Unlikely to the traditional LC resonant converter, the propose one has an inductor inside only. A single resonant takes place through the inside inductor and the capacitor from the plasma load modeled into two series capacitor and one resistance. The quasi-resonant can be achieved by cutting the switching signal when the load current decrease to zero. To obtain power control ability, the propose converter controlled by two control schemes. One is the changing output pulse period scheme in the manner of PFM(Pulse Frequency Modulation) control. On the other, to provide more higher power to load, the DC rail voltage is directly controlled by the 3-phase PFC boost converter. The significant merits of the proposed converter are the uniform power providing capability for high quality plasma generation and low reactive power in AC and DC side. The proposed work is verified through digital simulation and experimental implementation.

Probabilistic Safety Assessment of Offsite Power System Under Typhoon-induced High Wind (소외전력망의 태풍 동반 강풍 확률론적 안전성 평가)

  • Kim, Gungyu;Kwag, Shinyoung;Eem, Seunghyun;Jin, Seung-Seop
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.44 no.3
    • /
    • pp.277-282
    • /
    • 2024
  • Recently, the intensity and frequency of typhoons have been increasing due to climate change, and typhoons can cause a loss of offsite power (LOOP) at nuclear power plants (NPPs). Therefore, it is necessary to prepare for typhoon-induced high winds through the probabilistic safety assessment (PSA) of offsite power systems. However, research on PSA for offsite power system in NPPs under typhoon-induced high winds is still lacking. In this study, PSA was performed for offsite power systems subjected to typhoon-induced high winds at the Kori NPP site, which has experienced frequent damages to its offsite power system among NPP sites in Korea. In order to perform PSA for typhoon-induced high winds in offsite power systems, the typhoon hazard at Kori NPP site was derived using logic tree and Monte Carlo simulation. Utilizing the fragility of components constituting the power system, performed a fragility analysis of the power system. Lastly, the probability that offsite power system will not be able to supply power to the NPP was derived.