• Title/Summary/Keyword: high energy physics

Search Result 744, Processing Time 0.028 seconds

Growth and Characterization of AgGa$Se_2$ Single Crystal Thin Films by Hot Wall Epitaxy (Hot Wall Epitaxy (HWE)법에 의한 AgGa$Se_2$ 단결정 박막 성장과 특성)

  • Hong, Gwang-Jun;Lee, Gwan-Gyo;Park, Jin-Seong
    • Korean Journal of Materials Research
    • /
    • v.11 no.5
    • /
    • pp.419-426
    • /
    • 2001
  • The stochiometric $AgGaSe_2$ polycrystalline mixture of evaporating materials for the $AgGaSe_2$ single crystal thin film was prepared from horizontal furnace. To obtain the single crystal thin films, $AgGaSe_2$ mixed crystal and semi-insulating GaAs(100) wafer were used as source material and substrate for the Hot Wall Epitaxy (HWE) system, respectively. The source and substrate temperature were fixed at$ 630^{\circ}C$ and $420^{\circ}C$, respectively. The thickness of grown single crystal thin films is 2.1$\mu\textrm{m}$. The single crystal thin films were investigated by photoluminescence and double crystal X-ray diffraction(DCXD) measurement. The carrier density and mobility of AgGaSe$_2$ single crystal thin films measured from Hall effect by van der Pauw method are $4.89\Times10^{17}$ cm$^{-3}$ , 129cm2/V.s at 293K, respectively. From the Photocurrent spectrum by illumination of perpendicular light on the c-axis of the AgGaSe$_2$ single crystal thin film, we have found that the values of spin orbit splitting $$\Delta$S_{o}$ and the crystal field splitting $\Delta$C$_{r}$, were 0.1762eV and 0.2474eV at 10K, respectively. From the photoluminescence measurement of AgGaSe$_2$ single crystal thin film, we observed free excision (EX) observable only in high quality crystal and neutral bound exciton ($D^{o}$ , X) having very strong peak intensity. And, the full width at half maximum and binding energy of neutral donor bound excition were 8mev and 14.1meV, respectively. By Haynes rule, an activation energy of impurity was 141 meV.ion energy of impurity was 141 meV.

  • PDF

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2009 (설비공학 분야의 최근 연구 동향 : 2009년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwa-Taik;Lee, Dae-Young;Kim, Seo Young;Choi, Jong-Min;Baik, Yong-Kyu;Kwon, Young-Chul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.7
    • /
    • pp.492-507
    • /
    • 2010
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2009. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) Research trends of thermal and fluid engineering have been surveyed as groups of general thermal and fluid flow, fluid machinery and piping, and new and renewable energy. Various topics were covered in the field of general thermal and fluid flow such as an expander, a capillary tube, the flow of micro-channel water blocks, the friction and anti-wear characteristics of nano oils with mixtures of refrigerant oils, etc. Research issues mainly focused on the design of micro-pumps and fans, the heat resistance reliability of axial smoke exhaust fans, and hood systems in the field of fluid machinery and piping. Studies on ground water sources were executed concerning two well type geothermal heat pumps and multi-heat pumps in the field of new and renewable energy. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics and industrial heat exchangers. Researches on heat transfer characteristics included the heat transfer in thermoelectric cooling systems, refrigerants, evaporators, dryers, desiccant rotors. In the area of industrial heat exchangers, researches on high temperature ceramic heat exchangers, plate heat exchangers, frosting on fins of heat exchangers were performed. (3) In the field of refrigeration, papers were presented on alternative refrigerants, system improvements, and the utilization of various energy sources. Refrigeration systems with alternative refrigerants such as hydrocarbons, mixed refrigerants, and $CO_2$ were studied. Efforts to improve the performance of refrigeration systems were made applying various ideas of suction line heat exchangers, subcooling bypass lines and gas injection systems. Studies on heat pump systems using unutilized energy sources such as river water, underground water, and waste heat were also reported. (4) Research trend in the field of mechanical building facilities has been found to be mainly focused on field applications rather than performance improvements. In the area of cogeneration systems, papers on energy and economic analysis, LCC analysis and cost estimating were reported. Studies on ventilation and heat recovery systems introduced the effect on fire and smoke control, and energy reduction. Papers on district cooling and heating systems dealt with design capacity evaluation, application plan and field application. Also, the maintenance and management of building service equipments were presented for HVAC systems. (5) In the field of architectural environment, various studies were carried to improve indoor air quality and to analyze the heat load characteristics of buildings by energy simulation. These studies helped to understand the physics related to building load characteristics and to improve the quality of architectural environment where human beings reside in.

Educational Implications for Pre-Service Science Teacher Training through the Comparative Analysis between 'Integrated Science' based on the 2015 Revised Science Curriculum and Educational Contents presented in the Pre-Service Science Teachers' Textbooks of the College of Education (2015 개정 과학과 교육과정 '통합과학'과 사범대학 예비 과학 교사 교육 내용의 분석을 통한 예비 과학 교사 교육에 대한 시사점)

  • Kim, Nam Hui;Shim, Kew-Cheol
    • Journal of The Korean Association For Science Education
    • /
    • v.35 no.6
    • /
    • pp.1039-1048
    • /
    • 2015
  • The purpose of this study is to examine implications of pre-service science teacher training by analyzing science field integration and connection between learning content presented in 'Integrated Science' for high school students based on the 2015 revised science curriculum, and in pre-service science learning materials (textbooks) of the college of education. For this study, the 2015 revised 'Integrated Science' curriculum and 11 types of pre-service science teachers' learning materials related to physics, chemistry, biological science, and earth science were selected. The results were as follows. Most of the learning content presented in the 2015 revised 'Integrated Science' curriculum had integrated two or more science fields. Also, almost all learning content presented in the 2015 revised 'Integrated Science' curriculum were included in pre-service science teachers' education content, with educational content for chemistry introduced at the highest rate. The textbooks for pre-service science teachers had the most learning contents of 'Energy and Environment' domain of 'Integrated Science' for high school students. Accordingly, these results suggest that 'integrated science materials' should be developed for proper the curriculum implementation. Also, training courses for science teachers responsible for 'Integrated Science' are required. Furthermore, a revised curriculum for the college of education and a method to link with certification examinations for secondary school teachers are needed.

Study on the Change of Electrical Properties of two-dimensional SnSe2 Material via Cl doping under a High Temperature Condition (이차원 SnSe2 전자소재의 Cl 도핑에 따른 고온 전도 물성 고찰)

  • Moon, Seung Pil;Kim, Sung Wng;Sohn, Hiesang;Kim, Tae Wan;Lee, Kyu Hyoung;Lee, Kimoon
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.24 no.2
    • /
    • pp.49-53
    • /
    • 2017
  • We study on the change of electrical properties of two-dimensional (2D) $SnSe_2$ materials with respect to Cl doping as $SnSe_{1.994}Cl_{0.006}$ under a high temperature condition. (300~450 K) By the simple solid-state reaction method, non-and Cl-doped 2D $SnSe_2$ materials are successfully synthesized with negligible impurities as confirmed by X-ray diffraction. From the temperature dependence of resistivity, it is observed that the conduction mechanism is changed from hopping to degenerate conduction with Cl doping. By Hall effect measurement, an increase on electron carrier concentration from ${\sim}7{\times}10^{16}$ to ${\sim}3{\times}10^{18}cm^{-3}$ with Cl doping verifies that Cl is an effective electron donor which results in the encouraged carrier concentration. Detailed analysis for temperature dependent Hall mobility reveals that the electrical transports in high temperature regime are governed by the grain boundary-controlled mechanism for non-doped $SnSe_2$, which is effectively suppressed by Cl-doping as entering metallic transport regime.

Preparation and characterization of Mn doped copper nitride films with high photocurrent response

  • Yu, Aiai;Hu, Ruiyuan;Liu, Wei;Zhang, Rui;Zhang, Jian;Pu, Yong;Chu, Liang;Yang, Jianping;Li, Xing'ao
    • Current Applied Physics
    • /
    • v.18 no.11
    • /
    • pp.1306-1312
    • /
    • 2018
  • The Mn-doped copper nitride ($Cu_3N$) films with Mn concentration of 2.0 at. % have high crystallinity and uniform surface morphology. We found that the as-synthesized Mn-doped $Cu_3N$ films show suitable optical absorption in the visible region and the band gap is ~1.48 eV. A simple photodetector based on Mn doped $Cu_3N$ films was firstly fabricated via magnetron sputtering method. The fabricated device with doping of Mn demonstrated high photocurrent response and fast response shorter than 0.1 s both for rise and decay time superior to the pure $Cu_3N$. Furthermore, the energy levels of Mn-doped Cu3N matched well with ITO and Ag electrode. The excellent photoelectric properties reflect a good balance between sensitivities and response rate. Our investigation reveals the excellent potential of Mn-doped $Cu_3N$ films for application of photodetectors.

Active Phytochemicals of Indian Spices Target Leading Proteins Involved in Breast Cancer: An in Silico Study

  • Ashok Kumar Krishnakumar;Jayanthi Malaiyandi;Pavatharani Muralidharan;Arvind Rehalia;Anami Ahuja;Vidhya Duraisamy;Usha Agrawal;Anjani Kumar Singh;Himanshu Narayan, Singh;Vishnu Swarup
    • Journal of the Korean Chemical Society
    • /
    • v.68 no.3
    • /
    • pp.151-159
    • /
    • 2024
  • Indian spices are well known for their numerous health benefits, flavour, taste, and colour. Recent Advancements in chemical technology have led to better extraction and identification of bioactive molecules (phytochemicals) from spices. The therapeutic effects of spices against diabetes, cardiac problems, and various cancers has been well established. The present in silico study aims to investigate the binding affinity of 29 phytochemicals from 11 Indian spices with two prominent proteins, BCL3 and CXCL10 involved in invasiveness and bone metastasis of breast cancer. The three-dimensional structures of 29 phytochemicals were extracted from PubChem database. Protein Data Bank was used to retrieve the 3D structures of BCL3 and CXCL10 proteins. The drug-likeness and other properties of compounds were analysed by ADME and Lipinski rule of five (RO5). All computational simulations were carried out using Autodock 4.0 on Windows platform. The proteins were set to be rigid and compounds were kept free to rotate. In-silico study demonstrated a strong complex formation (positive binding constants and negative binding energy ΔG) between all phytochemicals and target proteins. However, piperine and sesamolin demonstrated high binding constants with BCL3 (50.681 × 103 mol-1, 137.76 × 103 mol-1) and CXCL10 (98.71 × 103 mol-1, 861.7 × 103 mol-1), respectively. The potential of these two phytochemicals as a drug candidate was highlighted by their binding energy of -6.5 kcal mol-1, -7.1 kcal mol-1 with BCL3 and -6.9 kcal mol-1, -8.2 kcal mol-1 with CXCL10, respectively coupled with their favourable drug likeliness and pharmacokinetics properties. These findings underscore the potential of piperine and sesamolin as drug candidates for inhibiting invasiveness and regulating breast cancer metastasis. However, further validation through in vitro and in vivo studies is necessary to confirm the in silico results and evaluate their clinical potential.

Skin Damage Sustained During Head-and-Neck and Shoulder Radiotherapy Due to the Curvature of Skin and the Use of Immobilization Mask (머리-목 그리고 어깨의 방사선 치료 시 피부곡면과 고정장치로 인한 피부손상연구)

  • Kim, Soo-Kil;Jeung, Tae-Sig;Lim, Sang-Wook;Park, Yeong-Mouk;Park, Dahl
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.86-92
    • /
    • 2010
  • The purpose of this study was to measure curvature contour skin dose using radiochromic film and TLD for a conventional open field. We also attempted to quantify the degradation of skin sparing associated with use of immobilization devices for high energy photon beams and to calculate the skin dose with a help of Monte Carlo (MC) simulation. To simulate head-and-neck and shoulder treatment, a cylindrical solid water phantom 11 cm in diameter was irradiated with 6 MV x-rays using $40{\times}40\;cm^2$ field at 100 cm source axis distance (SAD) to the center of the phantom. Aquaplastic mesh mask was placed on the surface of the cylindrical phantom that mimicked relevant clinical situations. The skin dose profile was obtained by taking measurements from $0^{\circ}$ to $360^{\circ}$ around the circumference of the cylindrical phantom. The skin doses obtained from radiochromic film were found to be 47% of the maximum dose of $D_{max}$ at the $0^{\circ}$ beam entry position and 61% at the $90^{\circ}$ oblique beam position without the mask. Using the mask (1.5 mm), the skin dose received was 59% at $0^{\circ}$ incidence and 78% at $80^{\circ}$ incidence. Skin dose results were also gathered using thin thermoluminescent dosimeters (TLD). With the mask, the skin dose was 66% at $0^{\circ}$ incidence and 80% at $80^{\circ}$ incidence. This method with the mask revealed the similar pattern as film measurement. For the treatments of the head-and-neck and shoulder regions in which immobilization mask was used, skin doses at around tangential angle were nearly the same as the prescription dose. When a sloping skin contour is encountered, skin doses may be abated using thinner and more perforated immoblization devices which should still maintain immoblization.

Practical Output Dosimetry with Undefined $N_{dw}{^{Co-60}}$ of Cylindrical Ionization Chamber for High Energy Photon Beams of Linear Accelerator ($N_{dw}{^{Co-60}}$이 정의되지 않은 원통형 이온전리함을 이용한 고에너지 광자선의 임상적 출력선량 결정)

  • Oh, Young-Kee;Choi, Tae-Jin;Song, Ju-Young
    • Progress in Medical Physics
    • /
    • v.23 no.2
    • /
    • pp.114-122
    • /
    • 2012
  • For the determination of absorbed dose to water from a linear accelerator photon beams, it needs a exposure calibration factor $N_x$ or air kerma calibration factor $N_k$ of air ionization chamber. We used the exposure calibration factor $N_x$ to find the absorbed dose calibration factors of water in a reference source through the TG-21 and TRS-277 protocol. TG-21 used for determine the absorbed dose in accuracy, but it required complex calculations including the chamber dependent factors. The authors obtained the absorbed dose calibration factor $N_{dw}{^{Co-60}}$ for reduce the complex calculations with unknown $N_{dw}$ only with $N_x$ or $N_k$ calibration factor in a TM31010 (S/N 1055, 1057) ionization chambers. The results showed the uncertainty of calculated $N_{dw}$ of IC-15 which was known the $N_x$ and $N_{dw}$ is within -0.6% in TG-21, but 1.0% in TRS-277. and TM31010 was compared the $N_{dw}$ of SSDL to that of PSDL as shown the 0.4%, -2.8% uncertainty, respectively. The authors experimented with good agreement the calculated $N_{dw}$ is reliable for cross check the discrepancy of the calibration factor with unknown that of TM31010 and IC-15 chamber.

Film Dosimetry for Intensity Modulated Radiation Therapy : Dosimetric Evaluation (필름을 사용한 세기변조치료법에 대한 선량측정)

  • Ju Sang Gyu;Yeo Inhwan Jason;Huh Seung Jae;Choi Byung Ki;Park Young Hwan;Ahn Yong Chan;Kim Dae Yong;Kong Young Kun
    • Radiation Oncology Journal
    • /
    • v.20 no.2
    • /
    • pp.172-178
    • /
    • 2002
  • Purpose : X-ray film over responds to low-energy photons in relative photon beam dosimetry because its sensor is based on silver bromide crystals, which are high-Z molecules. This over-response becomes a significant problem in clinical photon beam dosimetry particularly in regions outside the penumbra. In intensity modulated radiation therapy (IMRT), the radiation field is characterized by multiple small fields and their outside-penumbra regions. Therefore, in order to use film dosimetry for IMRT, the nature the source of the over-response in its radiation field need to be known. This study is aimed to verify and possibly improve film dosimetry for IMRT. Materials and Method : Modulated beams were constructed by a combination of five or seven different static radiation fields using 6 MeV X-rays. In order to verify film dosimetry, we used X-ray film and an ion chamber were used to measure the dose profiles at various depths in a phantom. In addition, in order to reduce the over-response, 0.01 inch thick lead filters were placed on both sides of the film. Results : The measured dose profiles showed a film over-response at the outside-penumbra and low dose regions. The error increased with depths and approached 15% at a maximum for the field size of $15{\times}15cm^2$ at 10 cm depth. The use of filters reduced the error to 3%, but caused an under-response of the dose in a perpendicular set-up. Conclusion : This study demonstrated that film dosimetry for IMRT involves sources of error due to its over-response to low-energy Photons. The use of filers can enhance the accuracy in film dosimetry for IMRT. In this regard, the use of optimal filter conditions is recommended.

Study on the Measurement of TMP Pumping Speed (터보분자펌프(TMP) 배기속도 측정에 관한 고찰)

  • Kang, S.B.;Shin, J.H.;Cha, D.J.;Koh, D.Y.;Cheung, W.S.;Lim, J.Y.
    • Journal of the Korean Vacuum Society
    • /
    • v.19 no.4
    • /
    • pp.249-255
    • /
    • 2010
  • Methods of the characteristics evaluation of turbo-molecular pumps (TMP) are well-defined in the international measurement standards such as ISO, PNEUROP, DIN, JIS, and AVS. The Vacuum Center in the Korea Research Institute of Standards and Science (KRISS) has recently designed, constructed, and established the integrated characteristics evaluation system of TMPs based on the international documents by continuously pursuing and acquiring the reliable international credibility through measurement perfection. The measurement of TMP pumping speed is normally performed with the throughput and orifice methods dependent on the mass flow regions. However, in the UHV range of the molecular flow region, the high uncertainties of the gauges, mass flow rates, and conductance are too critical to precisely accumulate reliable data. In order to solve the uncertainty problems of pumping speeds in the UHV range, we introduced a SRG with 1% accuracy and a constant volume flow meter (CVFM) to measure the finite mass flow rates down to $10^{-1}$ Pa-L/s with 3% uncertainty for the throughput method. In this way we have performed the measurement of pumping speed down to $10^{-4}$ Pa with an uncertainty of less than 6% for a 1000 L/s TMP. In this article we suggest that the CVFM has an ability to measure the conductance of the orifice experimentally with flowing the known mass through the orifice chambers, so that we may overcome the discontinuity problem encountering during introducing two measurement methods in one pumping speed evaluation sequence.