• Title/Summary/Keyword: high dose rate

Search Result 887, Processing Time 0.032 seconds

Induction of Mutants by Irradiation of $\gamma$-Ray on In vitro Shoots of Persimmon (기내$\gamma$-선 처리에 의한 감(Diospyros kaki Thunb.) 돌연변이 유기)

  • 고갑천
    • Korean Journal of Plant Tissue Culture
    • /
    • v.27 no.2
    • /
    • pp.143-148
    • /
    • 2000
  • This study was carried out to know the optimum dose of gamma-ray for the induction of mutation in vitro and the characteristics of the mutants induced by gamma-ray in persimmon (Diospyros kaki Thunb.). The LD50 (50% lethal dose) for in vitro shoots of the cultivar, Nishimurawase was between 1 krad and 2 krad and about 1 krad for the cultivar, Ichikikeijiro. As the dose of gamma-ray increased, the length of shoots decreased and necrosis of buds increased. For the cultivar, Nishmurawase, 37.5∼58.3% shoots rooted and the rooting rate and the number of roots per shoot was low in high gamma-ray. The irradiated young plants which were grown in the growth cabinet for 6 weeks were shorter in shoot length and had more branches than non-irradiated plants. The survival rate of irradiated plants grown in the green house for 3 months was 33%, while 77% for control plants.

  • PDF

Effect of ionizing radiation on cultured submandibular gland (SG) cells of mouse (전리 방사선 조사에 의한 마우스 배양 악하선 세포의 변화)

  • Lee, Song-Jae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.4 no.1
    • /
    • pp.71-77
    • /
    • 1990
  • The present study was undertaken to investigate effects of ionizing radiation on DNA synthesis and chromosomal abnormality in cultured submandibular gland(SG) cells. SG cells from C57BL/6N Crj mice were cultured in Dulbecco's modified Eagle's medium (DME) supplemented with $10\%$ fetal bovine serum, antibiotics and fungizone. The cultured SG cells were irradiated with graded doses of gamma ray ($^{60}Co$) at a dose rate of 58.4rad/min. The effect of irradiation of $^{60}Co$ on DNA synthesis in cultured cells was evaluated by measuring the incorporation of 3H-TdR. Using conventional chromosome techniques and Giemsa staining methods, chromosomal abnormalities in cultured SG cells, induced by irradiation of $^{60}Co$ werw examined. Cytological observations were carried out by a light microscope with high resolving power. The results obtained were as follows : 1. DNA synthesis of SG cells was quantitatively dependent on a radiation dose compare to control. 2. A polyploids and few chromosome-type break, such as single and double breaks, deltions and triradial figures were more predominantly in irradiated SG cells than in control. This increase of chromosomal abnormality was in the proposition to the irradiation doses.

  • PDF

Radionuclide concentrations in agricultural soil and lifetime cancer risk due to gamma radioactivity in district Swabi, KPK, Pakistan

  • Umair Azeem;Hannan Younis;Niamat ullah;Khurram Mehboob;Muhammad Ajaz;Mushtaq Ali;Abdullah Hidayat;Wazir Muhammad
    • Nuclear Engineering and Technology
    • /
    • v.56 no.1
    • /
    • pp.207-215
    • /
    • 2024
  • This study focuses on measuring the levels of naturally occurring radioactivity in the soil of Swabi, Khyber Pakhtunkhwa, Pakistan, as well as the associated health hazard. Thirty (30) soil samples were collected from various locations and analyzed for 226Ra, 232Th, and 40K radioactivity levels using a High Purity Germanium detector (HPGe) gamma-ray spectrometer with a photo-peak efficiency of approximately 52.3%. The average values obtained for these radionuclides are 35.6 ± 5.7 Bqkg-1, 47 ± 12.5 Bqkg-1, and 877 ± 153 Bqkg-1, respectively. The level of 232Th is slightly higher and 40K is 2.2 times higher than the internationally recommended limit of 30 Bqkg-1 and 400 Bqkg-1, respectively. Various parameters were calculated based on the results obtained, including Radium Equivalent (Raeq), External Hazard (Hex), Absorbed Dose Rate (D), Annual Gonadal Equivalent Dose (AGDE), Annual Effective Dose Rate, and Excess Lifetime Cancer Risk (ELCR), which are 170.3 ± 24 Bqkg-1, 0.46 ± 0.06 Bqkg-1, 81.4 ± 2.04 nGy h-1, 582 ± 78.08 µSvy-1, 99.8 ± 13.5 µSv Gy-1, and 0.349 ± 0.04, respectively. These values are below the limits recommended by the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR) in 2002. This study highlights the potential radiation threats associated with natural radioactivity levels in the soil of Swabi and provides valuable information for public health and safety.

Effect of the Space Dose Rate due to Change of X-ray Irradiation Energy and MU Value in Radiation Therapy Room (선형가속기의 엑스선 조사에너지와 MU값의 변화가 치료실 내 공간선량률 변화에 미치는 영향)

  • Kwon, Hyeonghyo;Park, Geonryul;Kim, Minji;Jo, Yeongdan;Kim, Youngjae
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.2
    • /
    • pp.77-83
    • /
    • 2020
  • This study investigated the radiation protection of therapeutic radiologists. Based on the change in X-ray energy and MU value, the space dose rate in the treatment room after the irradiation was measured. 6MV, 10MV and 15MV photon beams were exposed to radiation inside the treatment room based on 300MU, 600MU and 1000MU using a linear accelerator. And repeated 10 times under the same conditions. As a result of the experiment, 0.1555 μSv/h for 6MV 300MU, 0.157 μSv /h for 300sec, 0.152 μSv/h, 0.156 μSv/h for 600MU, and 0.157 μSv/h 0.152 μSv/h for 1000MU. 300MU of 10MV was 0.49 μSv/h, 0.309 μSv/h, and 0.69 μSv/h, 0.416 μSv/h for 600MU, respectively, and 1000MU was 0.977 μSv/h and 0.478 μSv/h, respectively. The 300MU of 15MV was 3.02 μSv/h, 1.2 μSv/h, 5.459 μSv/h at 600MU, 7.34 μSv/h at 1.836 μSv/h 1000MU, and 2.709 μSv/h. The average spatial dose rate of 6MV was not significantly different from the natural spatial dose rate in the treatment room. High spatial dose rates were measured at 10 MV and 15 MV and were attenuated over time. Therefore, entering the treatment room after a certain period of time (more than 60 seconds) is considered to be effective to prevent the exposure dose of radiation workers.

The Effects of Majarol on the Blood Pressure and Heart Rate in Rats and Isolated Frog Heart (Majarine 유도체인 majarol의 흰쥐에 있어서 혈압 및 심박동수에 대한 작용과 적출 개구리 심장에 대한 작용)

  • Lee Jong-Hwoa;Park Young-Hyun;Cho Byung-Heon;Kim Yu-Jae;Kim Jong-Bae;Kim Chun-Sook;Cha Young-Deog;Kim Young-Suk
    • The Korean Journal of Pharmacology
    • /
    • v.22 no.1 s.38
    • /
    • pp.34-44
    • /
    • 1986
  • In our previous studies, we had clarified many pharmacological effects of majarine: the bacteriostatic effect in vitro; the potentiation of hypnotic action of alcohol; hypotensive effect in rats and hypothermic effect in mice. This study was undertaken to search for a new antihypertensive drug. Red crystalline was obtained from majarine (which was extracted from Berberis koreana Palibin) by chemical methods. And this crystalline was identified as $C_{19}H_{16}NO_4$ contained one hydroxy group instead of methoxy group of majarine in isoquinoline ring and named 'Majarol' (5,6-Dihydro-9-hydroxy, 10-methoxybenzo-[g]-1,3-benzodioxolo [5,6-a] quinolizinium). We examined the effects of majarol on blood pressure and heart rate in urethane ancsthetized rats and the rate and amplitude of contraction of isolated frog heart. Several drugs: atropine sulfate, diphenhydramine chloride, hexamethonium bromide, phentolamine, epinephrine, propranolol and isoproterenol were used to clarify the mechanism of the hypotensive action of majarol. The results of experimints were as follows; 1. In low dose (0.5-2mg/kg, i.v.), majarol showed a typical transient hypotensive effect and slight decrease in heart rate. In high dose (5-10 mg/kg, i.v.), majarol showed a typical transient and a subsequent prolonged hypotensive effect and a significant prolonged decrease in heart rate was followed. 2. The hypotensive effects of majarol was not abolished by the pretreatments with atropine sulfate, hexamethonium bromide and diphenhydramine. The pretreatment with phentolamine inhibited significantly the hypotensive effects of majarol and the pretreatment wtih majarol blocked markedly the hypertensive effect of epinephrine. The positive chronotropic effect of isoproterenol was not blocked by the pretreatment with majarol. 3. In low dose, majarol increased the amplitude and decreased rate of contraction, but in high dose, majarol inhibited the amplitude and rate of contraction of isolated frog heart.

  • PDF

Effect of Alginate on the Growth of Nannochloropsis oculata NIES-2145 (알긴산이 Nannochloropsis oculata NIES-2145의 생장에 미치는 영향)

  • Park, Hyun-Jin;Kim, Young-Hwa;Lee, Jae-Hwa
    • KSBB Journal
    • /
    • v.26 no.3
    • /
    • pp.206-210
    • /
    • 2011
  • The growth effect of Nannochloropsis oculata (N.oculata), unicellular microalgae, by alginate was investigated. Alginate was depolymerized with sulfuric acid ($H_2SO_4$) and heat ($121^{\circ}C$), simultaneously. Addition of 0.75% alginate oligomer depolymerized with 0.2 N $H_2SO_4$ showed the maximum yield and the growth rate of N. oculata. Chlorophyll content and reducing sugar was increased by alginate oligomer in a dose-dependent manner. Alginate oligomer promoted the growth of N. oculata, whereas the original alginate polysaccharides had no significant effect. Laminaria japonica (L. japonica) extract containing high level of alginate was also increased growth rate and chlorophyll content. $CO_2$ supply addition to L. japonica extract showed no change the growth rate, although addition to alginate oligomer showed prominently increased. N. oculata could use more saccharides in presence of $CO_2$ according to reducing sugar determination. From these results, it is useful to establish optimal condition for high cell density cultivation of N. oculata.

Pharmacological Actions of New Woohwangchungsimwon Liquid on Cardiovascular System (신우황청심원액의 심혈관계에 관한 약효연구)

  • 조태순;이선미;김낙두;허인회;안형수;박대규
    • Biomolecules & Therapeutics
    • /
    • v.5 no.4
    • /
    • pp.390-401
    • /
    • 1997
  • In order to investigate the pharmacological properties of New Woohwangchungsimwon Liquid (NCL), effects of Woohwangchungsimwon Liquid (CL) and NCL were compared. In isolated rat aorta, NCL and CL showed the relaxation of blood vessels in maximum contractile response to phenylephrine (10$^{-6}$ M) without regard to intact endothelium or denuded rings of the rat aorta. Furthermore, the presences of the inhibitor of NO synthase and guanylate cyclase did not affect the relaxation of NCL and CL. NCL and CL inhibited the vascular contractions induced by acetylcholine, prostaglandin endoperoxide or peroxide in a dose-dependent manner. In conscious spontaneously hypertensive rats (SHRs), NCL and CL significantly decreased heart rate. NCL and CL, at high doses, had a negative inotropic effect that was a decrease of LVDP and (-dp/dt)/(+dp/dt) in the isolated perfused rat hearts, and also decreased the contractile force and heart rate in the isolated rat right atria. In excised guinea-pig papillary muscle, NCL and CL had no effects on parameters of action potential at low doses, whereas inhibited the cardiac contractility at high doses. These results suggested that NCL and CL have weak cardiovascular effects with relaxation of blood vessels and decrease of heart rate, and that this effect is no significant differences between two preparations.

  • PDF

Pharmacological Actions of New Wonbang Woohwangchungsimwon Liquid on Cardiovascular System (신원방우황청심원액의 심혈관계에 관한 약효)

  • 조태순;이선미;김낙두;허인회;안형수;권광일;박석기;심상호;신대희
    • Biomolecules & Therapeutics
    • /
    • v.7 no.1
    • /
    • pp.66-78
    • /
    • 1999
  • In order to investigate the pharmacological properties of New Wonbang Woohwangchungsimwon Liquid (NSCL), effects of Wonbang Woohwangchungsimwon Liquid (SCL) and NSCL were compared. In isolated rat aorta, NSCL and SCL showed the relaxation of blood vessels in maximum contractile response to phenylephrine (10$^{-6}$ M) regardless to intact endothelium or denuded rings of the rat aorta. Furthermore, the presences of the inhibitor of NO synthase and guanylate cyclase did not affect the relaxing effect of NSCL and SCL. NSCL and SCL inhibited the vascular contractions induced by acetylcholine, prostaglandin endoperoxide or peroxide in a dose-dependent manner. In conscious spontaneously hypertensive rats (SHRs), NSCL and SCL significantly decreased heart rate. NSCL and SCL, at high doses, had a negative inotropic effect that was a decrease of left ventricular developed pressure and (-dp/dt)/(+dp/dt) in the isolated perfused rat hearts, and also decreased the contractile force and heart rate in the isolated rat right atria. In excised guinea-pig papillary muscle, NSCL and SCL had no effects on parameters of action potential such as resting membrane potential, action potential amplitude, APD$_{90}$ and V$_{max}$ at low doses, whereas inhibited the cardiac contractility at high doses. These results suggested that NSCL and SCL have weak cardiovascular effects with relaxation of blood vessels and decrease of heart rate, and that this effect is no significant differences between cardiovascular effects of two preparations.s.

  • PDF

Comparison between the Calculated and Measured Doses in the Rectum during High Dose Rate Brachytherapy for Uterine Cervical Carcinomas (자궁암의 고선량율 근접 방사선치료시 전산화 치료계획 시스템과 in vivo dosimetry system 을 이용하여 측정한 직장 선량 비교)

  • Chung, Eun-Ji;Lee, Sang-Hoon
    • Radiation Oncology Journal
    • /
    • v.20 no.4
    • /
    • pp.396-404
    • /
    • 2002
  • Purpose : Many papers support a correlation between rectal complications and rectal doses in uterine cervical cancer patients treated with radical radiotherapy. In vivo dosimetry in the rectum following the ICRU report 38 contributes to the quality assurance in HDR brachytherapy, especially in minimizing side effects. This study compares the rectal doses calculated in the radiation treatment planning system to that measured with a silicon diode the in vivo dosimetry system. Methods : Nine patients, with a uterine cervical carcinoma, treated with Iridium-192 high dose rate brachytherapy between June 2001 and Feb. 2002, were retrospectively analysed. Six to eight-fractions of high dose rate (HDR)-intracavitary radiotherapy (ICR) were delivered two times per week, with a total dose of $28\~32\;Gy$ to point A. In 44 applications, to the 9 patients, the measured rectal doses were analyzed and compared with the calculated rectal doses using the radiation treatment planning system. Using graphic approximation methods, in conjunction with localization radiographs, the expected dose values at the detector points of an intrarectal semiconductor dosimeter, were calculated. Results : There were significant differences between the calculated rectal doses, based on the simulation radiographs, and the calculated rectal doses, based on the radiographs in each fraction of the HDR ICR. Also, there were significant differences between the calculated and measured rectal doses based on the in-vivo diode dosimetry system. The rectal reference point on the anteroposterior line drawn through the lower end of the uterine sources, according to ICRU 38 report, received the maximum rectal doses in only 2 out of the nine patients $(22.2\%)$. Conclusion : In HDR ICR planning for conical cancer, optimization of the dose to the rectum by the computer-assisted planning system, using radiographs in simulation, is improper. This study showed that in vivo rectal dosimetry, using a diode detector during the HDR ICR, could have a useful role in quality control for HDR brachytherapy in cervical carcinomas. The importance of individual dosimeters for each HDR ICR is clear. In some departments that do not have the in vivo dosimetry system, the radiation oncologist has to find, from lateral fluoroscopic findings, the location of the rectal marker before each fractionated HDR brachytherapy, which is a necessary and important step of HDR brachytherapy for cervical cancer.

Development of Dose Planning System for Brachytherapy with High Dose Rate Using Ir-192 Source (고선량률 강내조사선원을 이용한 근접조사선량계획전산화 개발)

  • Choi Tae Jin;Yei Ji Won;Kim Jin Hee;Kim OK;Lee Ho Joon;Han Hyun Soo
    • Radiation Oncology Journal
    • /
    • v.20 no.3
    • /
    • pp.283-293
    • /
    • 2002
  • Purpose : A PC based brachytherapy planning system was developed to display dose distributions on simulation images by 2D isodose curve including the dose profiles, dose-volume histogram and 30 dose distributions. Materials and Methods : Brachytherapy dose planning software was developed especially for the Ir-192 source, which had been developed by KAERI as a substitute for the Co-60 source. The dose computation was achieved by searching for a pre-computed dose matrix which was tabulated as a function of radial and axial distance from a source. In the computation process, the effects of the tissue scattering correction factor and anisotropic dose distributions were included. The computed dose distributions were displayed in 2D film image including the profile dose, 3D isodose curves with wire frame forms and dosevolume histogram. Results : The brachytherapy dose plan was initiated by obtaining source positions on the principal plane of the source axis. The dose distributions in tissue were computed on a $200\times200\;(mm^2)$ plane on which the source axis was located at the center of the plane. The point doses along the longitudinal axis of the source were $4.5\~9.0\%$ smaller than those on the radial axis of the plane, due to the anisotropy created by the cylindrical shape of the source. When compared to manual calculation, the point doses showed $1\~5\%$ discrepancies from the benchmarking plan. The 2D dose distributions of different planes were matched to the same administered isodose level in order to analyze the shape of the optimized dose level. The accumulated dose-volume histogram, displayed as a function of the percentage volume of administered minimum dose level, was used to guide the volume analysis. Conclusion : This study evaluated the developed computerized dose planning system of brachytherapy. The dose distribution was displayed on the coronal, sagittal and axial planes with the dose histogram. The accumulated DVH and 3D dose distributions provided by the developed system may be useful tools for dose analysis in comparison with orthogonal dose planning.