• Title/Summary/Keyword: heating jang

Search Result 532, Processing Time 0.029 seconds

Study of Radio Frequency Thawing for Cylindrical Pork Sirloin

  • Kim, Jinse;Park, Jong Woo;Park, Seokho;Choi, Dong Soo;Choi, Seung Ryul;Kim, Yong Hoon;Lee, Soo Jang;Park, Chun Wan;Han, Gui Jeung;Cho, Byoung-Kwan
    • Journal of Biosystems Engineering
    • /
    • v.41 no.2
    • /
    • pp.108-115
    • /
    • 2016
  • Purpose: Radio frequency (RF) heating is a promising thawing method, but it frequently causes undesirable problems such as non-uniform heating. This can occur because of the food shape, component distribution, and initial temperature differences between food parts. In this study, RF heating was applied to the thawing of cylindrically shaped pork sirloin by changing the shape of electrodes and the surrounding temperature. Methods: Curved electrodes were utilized to increase the thawing uniformity of cylindrically shaped frozen meat. Pork sirloin in the shape of a half-circle column was frozen in a deep freezer at $-70^{\circ}C$ and then thawed by RF heating with flat and curved electrodes. In order to prevent fast defrosting of the food surface by heat transfer from air to the food, the temperature of the thawing chamber was varied by -5, -10, and $-20^{\circ}C$. The temperature values of the frozen pork sirloin during RF thawing were measured using fiber-optic thermo sensors. Results: After multiple applications of curved electrodes resembling the food shape, and a cooled chamber at $-20^{\circ}C$ the half-cylindrically shaped meat was thawed without surface burning, and the temperature values of each point were similarly increased. However, with the parallel electrode, the frozen meat was partially burned by RF heating and the temperature values of center were overheated. The uniform heating rate and heat transfer prevention from air to the food were crucial factors for RF thawing. In this study, these crucial factors were accomplished by using a curved electrode and lowering the chamber temperature. Conclusions: The curved shape of the electrode and the equipotential surface calculated from the modeling of the parallel capacitor showed the effect of uniform heating of cylindrically shaped frozen food. Moreover, the low chamber temperature was effective on the prevention of the surface burning during RF thawing.

Determination of Inherent Strain Regions to Estimate Plate Deformation by Line Heating (선상가열 판변형 해석을 위한 고유변형도 영역의 결정법)

  • Chang-Doo Jang;Yun-Sok Yun;Dae-Eun Ko;Sung-Choon Moon
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.39 no.1
    • /
    • pp.82-89
    • /
    • 2002
  • The inherent strain method is known to be very effective in predicting the plate deformation by line heating. Traditionally the inherent strain regions have been determined from the temperature distribution and the phase transformation regions(Ac3) of welding experiments. Since the phenomena of line heating are similar to those of welding, the experimental results under the same welding conditions have been applied directly to line heating analysis. The results cannot, however, reflect the effect of heating pattern and plate thickness. Besides, water-cooling in the actual heating process can alter the steel's phase to martensite and shear plastic deformation occurs during the transformation. In this study, the experimental measurement of temperature distribution was substituted with a transient heat transfer analysis using FEM so that we could obtain the temperature distribution according to heat flux models of the heating pass. In order to consider plastic strains occurring additionally under phase transformation, inherent strain regions were assumed to be limited to the eutectoid temperature(Ac1). Using the regions, plate deformations could be predicted to validate our method and the results were in good agreement with the experimental ones

Analysis on Heating Effects of the Vertical Type Geothermal Heat Pump System

  • Kang, Youn Ku;Ryou, Young Sun;Jang, Jae Kyung;Kim, Young Hwa
    • Journal of Biosystems Engineering
    • /
    • v.39 no.2
    • /
    • pp.69-75
    • /
    • 2014
  • Purpose: This paper is aimed at analyzing the heating performance of the vertical closed loop type Geothermal Heat Pump System (GHPS) distributing the farm site and providing basic data of the GHPS. Method: Seedling greenhouse heating was made from October 2012 to May 2013. The seedling greenhouse was divided into 4 sectors (A, B, C and D zone, total $3,300m^2$) with different temperatures. It was heated from 5PM to 8AM, and during the night the greenhouse was covered by non-woven fabric thermal curtains along the upper 2m of the greenhouse for temperature maintenance. In order to analyze the heating performance of the GHPS, power consumption and operating time of the GHPS, inlet and outlet water temperature of the condenser, temperatures of each zone of the greenhouse, and ambient temperature were measured. Results: When operating only one heat pump unit, heat generated in the condenser decreased as the experiment progressed and power consumption increased correspondingly. However, the heating coefficient of performance decreased from 3.3 to 2.0 rapidly. Also, when operating two heat pump units, heat generated in the condenser decreased and power consumption increased. Heating coefficient of performance decreased from 4.5 to 3.7 rapidly. When the set temperature of the greenhouse was $13.7{\sim}20.1^{\circ}C$ and minimum ambient temperature was $-20.8{\sim}4.8^{\circ}C$, the annually accumulated heat and power consumption were 520,623 kW, 142,304 kW, respectively. Conclusion: When the set temperature of the greenhouse was $13.7{\sim}20.1^{\circ}C$ and the minimum ambient temperature was $20.8{\sim}4.8^{\circ}C$, the annually accumulated heat and power consumption were 520,623 kW, 142,304 kW, respectively. When operating only one heat pump unit, the heating COP was 2.0~3.3, and when operating 2 heat pump units, it was 3.7~4.5. If several heat pumps are installed in one GHPS, it is suggested that all heat pumps be operated except in special cases. Because the scale of the water pumps are set to the scale of when all heat pump units are operating, if even one unit is not operating, the power consumption will increase. That becomes the cause of COP decrease.

Design of Improved Switch Point Heating System for Low Power and Simplified Equipment (저전력 및 설비간략화를 위한 선로전환기용 융설장치 설계)

  • Jang, Dongwan;Jeon, Taehyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.1
    • /
    • pp.61-67
    • /
    • 2013
  • The turnout point system is installed to separate the main rail track from other tracks in rail load stations. It is also important to set up the switch point system to change the direction of the turnout point, to lead and change the direction of tracks. The switch point system can be negatively affected by heavy snow during winter seasons which can cause critical safety problems. Furthermore, the maintenance and repair of the conventional system is prohibitively expensive due to its complexity and high probability of failure. In this paper, an efficient switch point system is proposed which simplifies the equipment structure and lowers the cost for maintenance and repair, while improving safety and performance of the rail road system.

Friction Welding of Cr-Mo Steel Bars for Hydraulic of Pneumatic Valve Spools and AE Evaluation (유공압 밸브스풀용 Cr-Mo 강봉의 동종재 마찰용접과 AE평가)

  • ;;Oh, S. K.;Jang, H. K.
    • Journal of Welding and Joining
    • /
    • v.13 no.4
    • /
    • pp.103-112
    • /
    • 1995
  • This study was performed to optimize friction welding conditions of Cr-Mo steel bars used for hydraulic of pneumatic valve spools and to realize the real-time evaluation of weld quality by acoustic emission method. SNCM220, SCM435, SCAM645, and SCM415 steel bars were tested to find optimum conditions of friction welding. Auantitative equations which exhibit the relations of tensile strength, elongation, reduction of area and energy absorption with friction heating time were obtained by the experiment. Acoustic emission was also performed in the friction weldig process, and the real-time evaluation was enabled to find the optimum range of weld strength. Finally, the strength and toughness of welded joints were interpreted by the sem analysis of tensile fracture surfaces.

  • PDF

A Experimental Study for Developing of the Dry Double Floors Hydronic Ondol System (건식이중바닥온돌시스템 개발을 위한 실험적 연구)

  • Kim Nan-Haeng;Sohn Jang-Yeul
    • Journal of the Korean housing association
    • /
    • v.17 no.3
    • /
    • pp.1-7
    • /
    • 2006
  • The aim of the research was to evaluate the characteristics of thermal environment and thermal comfort in the Dry Double floors Hydronic Ondol System. Physical indoor thermal environments (the floor surface temperature, the vertical temperature, etc.) and skin temperature have especially been measured. Physical features conditions, sensation, thermal comfort, humidity sensation, comfort of body were investigated for the survey. As a result, (1) During the operation of the boiler (12 hour), the average indoor temperature is appeared to be $21.6^{\circ}C$. The floor surface temperature showed peak value of $31.4{\sim}40.6^{\circ}C$ after 8hours 30minutes after the start-point of the heating. The vertical difference of temperature was turned out to be not uniform. (2) While the skin temperature showed a narrow distribution of temperature in the Dry Double floors Hydronic Ondol system. (3) The response to thermal comfort which people felt was satisfactory, and most of them felt dry during the test.

Induction Melting Process using Graphite Crucible for Metallurgical Grade Silicon (Graphite Crucible을 이용한 실리콘 유도 용융 공정)

  • Park, Sung-Soon;Jang, Bo-Yun;Kim, Joon-Soo;Ahn, Young-Soo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.223-223
    • /
    • 2010
  • 태양 전지에 사용되는 실리콘의 전자기 유도 용융 기술은 잉곳(ingot)의 성장 및 금속 정련 등의 핵심 공정인 실리콘 용융에서 사용되는 중요한 기술이다. 하지만, 유도 용융에 사용되는 흑연 도가니에 의한 실리콘의 오염은 실리콘의 순도저하에 요인으로 작용한다. 흑연 도가니와 용융된 실리콘이 접하는 계면에서 탄소의 오염이 발생하게 되며, 실리콘 내부에 흡수한 탄소는 대표적인 비금속 불순물로 태양전지 효율을 감소시킨다. 본 연구에서 사용되는 흑연 도가니는 유도 코일의 전자기력에 의해 실리콘과 무접촉 또는 연접촉이 가능한 구조이다. 또한, 유도 자기장을 이용하여 실리콘과 같은 반도체를 용융할 경우, 고상에서의 낮은 전기전도도로 인해 효과적인 줄-발열(Joule Heating)이 불가능하므로 플라즈마와 같은 보조 열원을 필요로 한다. 본 연구에서는, 보조 열원 없이 세그먼트(segment)된 흑연 도가니를 이용한 실리콘 용융 연구를 진행하였다.

  • PDF

Improvement of Thermal Enviromental by Two Air Out in Hot Air Heating (이중 취출구에 의한 온풍난방시의 열환경 개선)

  • Jang, In-Seong;Kim, J.S
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.33 no.3
    • /
    • pp.209-217
    • /
    • 1997
  • The objective of this paper is to improve a discomfort caused by the unequal airflow and vertical temperature difference by buoyancy of the supplied hot air in the conventional hot air heating system. In order to the model experiment we manufactured the hot air heater with two air outlet and a model room. We observed the temperature, velocity and airflow distribution and calculated values of PMV and PPD using mean value of central verticality section's air temperature and velocity. We could improve distribution of vertical temperature and velocity at the central section of the model room owing to correlation of hot air of two air outlet.

  • PDF

Neutral Beam assisted Chemical Vapor Deposition at Low Temperature for n-type Doped nano-crystalline silicon Thin Film

  • Jang, Jin-Nyeong;Lee, Dong-Hyeok;So, Hyeon-Uk;Yu, Seok-Jae;Lee, Bong-Ju;Hong, Mun-Pyo
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.52-52
    • /
    • 2011
  • A novel deposition process for n-type nanocrystalline silicon (n-type nc-Si) thin films at room temperature has been developed by adopting the neutral beam assisted chemical vapor deposition (NBa-CVD). During formation of n-type nc-Si thin film by the NBa-CVD process with silicon reflector electrode at room temperature, the energetic particles could induce enhance doping efficiency and crystalline phase in polymorphous-Si thin films without additional heating on substrate; The dark conductivity and substrate temperature of P-doped polymorphous~nano crystalline silicon thin films increased with increasing the reflector bias. The NB energy heating substrate(but lower than $80^{\circ}C$ and increase doping efficiency. This low temperature processed doped nano-crystalline can address key problem in applications from flexible display backplane thin film transistor to flexible solar cell.

  • PDF

A Calculation Method on Heat Flux from Ondol Floor Surface (온돌면(溫突面)의 방열량(放熱量) 산정방법(算定方法)에 관한 연구(硏究))

  • Sohn, Jang Yeul;Ahn, Byung Wook;Pang, Seung Ki
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.1 no.2
    • /
    • pp.173-181
    • /
    • 1989
  • Until recently there was a lack of reliable performance data for the design and operation of Ondol heating systems. This paper presents a calculation method on heat flux from Ondol floor surface. Total heat flux from floor consists of radiation and convection component. In order to analyse the characteristics of both radiation and convection heat flux, each surface temperature is measured and several temperatures near each wall are measured vertically and horizontally in a practical Ondol heating space. Radiation heat flux is calculated and analysed by Gebhart's Absorption Factor Method with the consideration of instantaneous radiant exchanges. Convection heat output is derived from the vertical temperature profiles near floor. The vertical temperature profiles could be expressed by nonlinear regression equation models and convection coefficients could be estimated by the equations. As a result, radiation, convection and total heat flux are suggested by the expression of difference between floor surface and room air temperature.

  • PDF