A Study on the Kinetics of Thermal Degradation of Polyethylene (폴리에틸렌 열분해의 속도론적 연구)

  • Kim, Myung Soo;Oh, Sea Cheon;Lee, Hae Pyeong;Kim, Hee Taik;Yoo, Kyong Ok
    • Applied Chemistry for Engineering
    • /
    • v.10 no.4
    • /
    • pp.548-556
    • /
    • 1999
  • The thermal degradation of polyethylene has been studied using a nonisothermal thermogravimetric technique under a nitrogen atmosphere condition at several heating rates from 10 to $50^{\circ}C/min$. To obtain information on the kinetic parameters, the dynamic thermogravimetric analysis curve and its derivative have been analyzed by a variety of analytical methods such as Kissinger, Freeman-Carroll, Flynn-Wall, Coats-Redfern, Chatterjee-Conrad, Friedman, Horowitz-Metzger, Ozawa and Denq methods. The comparative works for the kinetic results obtained from various methods should be performed to determine the kinetic parameters, because three are tremendous differences in the calculated kinetic parameters depending upon the mathematical method taken in the analysis. From this work, it was found that the apparent activation energy of HDPE was larger than those of LDPE and LLDPE.

  • PDF

An Experimental Study for Supposed Heating Temperature of Deteriorated Concrete Structure by fire Accident (화재피해를 입은 콘크리트구조물의 수열온도 추정을 위한 실험적 연구)

  • 권영진
    • Fire Science and Engineering
    • /
    • v.18 no.3
    • /
    • pp.51-56
    • /
    • 2004
  • A fire outbreak in a reinforcement concrete structure looses the organism by the different contraction and expansion of hardened cement pastes and aggregate, and causes cracks by thermal stress, leading to the deterioration of the durability. So concrete reinforcement structure is damaged partial or whole structure system. Therefore diagnosis of deterioration is needed based on mechanism of fire deterioration in general concrete structures. Fundamental information and data on the properties of concrete exposed to high temperature are necessary for accurate diagnosis of deterioration. In this study, it was presented data for the accurate diagnosis and selection of repair and reinforcement system for the deteriorated concrete heated highly, various concrete such as standard design compressive strength, fine aggregate and admixture were exposed to a high temperature environment. And fundamental data were measured engineering properties such as explosive spatting, ultrasonic pulse velocity and compressive strength.

Air Pollution Control In Industrialized Cities of the I.R. Iran

  • Ganjidoust, Hossein;Ayatl, Blta
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2003.11a
    • /
    • pp.15-18
    • /
    • 2003
  • Recently, some researches related to air pollution problems in large cities of the Islamic Republic of Iran have been done. Famous institutes and research centers in countries like Japan, Sweden and Germany have been in cooperation with Iranian institutes in implementing the results. Due to quick increase in the population because of peoples' migration from countryside to cities, and rate of growth in the early years after the revolution, air pollution was an important problem in I.R.Iran. Therefore, air pollution control is one of the main issues in major cities of I.R. Iran. It is the purpose of this study to investigate the control mechanisms for air pollution problems in the major industrial cities. The necessary action plans that were taken in recent years in some of the cities, which were also suggested to be taken in the other ones, are the other purpose of this study. From the results of studies it was obtained in Iran, lots of researches are important to mention. Amongst the main activities that are done in recent years are: establishing of the meteorological research centers and atmosphere sciences; three applicator meteorological research centers and more than 40 new stations in the country; installation of newest computer systems in metrological information, using of wall map and continuous radio-traffic to announce traffic news; completing of subway construction in Tehran; forbidding of industrial activities in a definite distance away from Tehran and transferring them to suitable places; building of highways and freeways; improving of public transportation and gasifying them; developing of fuels quality and removing lead from them; and gasifying of the heating systems in houses and buildings.

  • PDF

OSL Age Determination of the Hearths in a Bronze Age Dwelling Site by using Bayesian Statistics (베이지안 통계학을 이용한 청동기시대 주거지내 화덕자리들의 광자극발광(OSL) 연대 결정)

  • Kim, Myung-Jin;Yang, Hye-Jin;Hong, Duk-Geun
    • Journal of Radiation Protection and Research
    • /
    • v.36 no.2
    • /
    • pp.52-58
    • /
    • 2011
  • OSL dating for three hearths having the sequence of use and discard in No. 29 and 29-1 dwelling sites at Sogol cultural site was carried out. Resulting from the deconvolution of natural CW-OSL decay curve and thermal zeroing test, it was turned out that OSL signal was entirely composed of the heat- and light-sensitive fast component with high photoionization cross-section and all quartz OSL signals were thermally bleached under $300^{\circ}C$ which is the minimum temperature related to heating and cooking in Bronze age. After dose recovery test and plateau test, paleodose of each hearth sample was evaluated by using SAR method, and OSL age was determined from the ratio of paleodose to annual dose rate. For the purpose of the precision improvement of OSL age, Bayesian statistics was applied to each hearth's age and the archaeological sequence information. Finally, it could be concluded to the accurate use period of each hearth from the resultant OSL ages.

Microwave Sealing of Alumina Substrate with Sealing Glass (봉착용 유리를 이용한 알루미나 기판의 마이크로파 봉착)

  • Park, Seong-Su;Cha, Mu-Gyeong;Ryu, Bong-Gi;Sin, Hak-Gi;Park, Chan-Yeong;Min, Seong-Gi;Min, Seong-Gi
    • Korean Journal of Materials Research
    • /
    • v.9 no.2
    • /
    • pp.149-154
    • /
    • 1999
  • Alumina substrate was sealed by PbO-ZnO-$B_2O_3$glass using microwave heating. The crystallization behaviour of sealing glass and the state of sealing joint were investigated and were compared with those of conventionally sealed one. Compared to the conventional one, the microwave heat-treated sample had well-grown $\textrm{PbTiO}_3$ crystals and high degree of crystallinity even though it had shorter heat-treatment time and lower heat-treatment temperature. Also, the microwave sealed sample exhibited relatively a good sealing state and almost same bending strength.

  • PDF

Measurement of Environmental Tobacco Smoke in the Air of Offices in Urban Areas - Focusing on the Impact of Smoking on the Concentrations of Suspended Particles - (도시지역 사무실내 공기 중 환경담배연기의 측정 - 흡연이 부유먼지 농도에 미치는 영향을 중심으로 -)

  • Baek Sung-Ok;Park Sang-Kon
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.6
    • /
    • pp.715-727
    • /
    • 2004
  • This study was carried out to evaluate non-smoker's exposure levels to environmental tobacco smoke (ETS) in the air of offices in urban areas. A total of 65 offices were selected from two large cities, i.e. Daegu and Daejeon. The field sampling was conducted repeatedly in summer (1999) and winter (1999~2000). The measured ETS markers included respirable suspended particles (RSP as PM$_{40}$ ), vapor and particulate phase ETS markers, including nicotine, 3-ethnyl pyridine (3-EP), ultraviolet absorbing particulate matter (UVPM), fluorescing particulate matter (FPM), and solanseol in ETS particles (SolPM). RSP was measured gravimetrically by a microbalance. The particle samples were then used for the determination of particulate ETS markers by HPLC, while vapor phase markers determined by GC/NPD. The analytical methods were validated for repeatability, linearity, detection limits, and duplication precision. The concentrations of RSP and other ETS markers were significantly higher in smoking offices than non-smoking offices. Despite the similar smoking strength in each office for different seasons, the concentration levels of ETS components appeared to be higher in winter than summer. The contributions of ETS to RSP concentrations based on SolPM, FPM, and UVPM methods were estimated to be in the range of 15.2 ~ 25.3% in smoking offices, whereas 2.4 ~ 15.9% in non-smoking offices. The cooling and heating types did not affect significantly the concentrations of RSP and other ETS markers. Finally, further research issues were suggested to obtain more scientific information on the non-smoker's exposure to ETS with respect to the frame of risk assessment..

The Implemention of RTD-l000A based on ARM Microcontroller (ARM 마이크로컨트롤러 기반 RTD-1000A의 구현)

  • Kim, Min-Ho;Hong, In-Sik
    • Journal of Internet Computing and Services
    • /
    • v.9 no.6
    • /
    • pp.117-125
    • /
    • 2008
  • With increase of concern about the Ubiquitous application, the necessity of the computer system which is miniaturized is becoming larger. The ARM processor is showing a high share from embedded system market. In this paper, ideal method for RTD-1000 controller construction and development is described using ARM microcontroller. Existing RTD-1000 measures distance of disconnection or defect of sensing casket by measuring receiving reflected wave which was sent via copper wire inside the leaking sensing rod. Using this RTD-1000, leakage and breakage of water and oil pipe can be sensed and it reports damage results to the networks. But, existing RTD-1000 wastes hardware resources much and costs a great deal to installation. Also, it needs a cooling device because the heating problem, and has some problem of the secondary memory unit such as the hard disk. So, long tenn maintenance has some problems in the outside install place. In this paper, for the resolving the problem of RTD-1000, RTD-1000A embedded system based on ARM is proposed and simulated.

  • PDF

Analytical Study on the Fire Resistance of SC Composite Column (SC 합성기둥의 내화성능에 대한 해석연구)

  • Lim, Yoon Hee;Kang, Seong Deok;Oh, Myoung Ho;Kim, Myeong Han;Kim, Sang Dae
    • Journal of Korean Society of Steel Construction
    • /
    • v.19 no.3
    • /
    • pp.335-344
    • /
    • 2007
  • The steel-concrete composite column (i.e., the SC composite column) supports large-gravity loads and simplifies the installation and removal of the work in pouring the concrete. The column takes advantage of the in-plant prefabrication of steel, the speed of erection of a steel structure, and the fire resistance of steel. This paper presents the results of a parametric study using heat transfer analysis and a P-M interaction curve, and compares these results with the experimental results to check the accuracy of the proposed parametric studies. The parametric studies, such as the study of the concrete ratio of an area and the fire protection thickness, provide information on the fire resistance of SC composite columns.

Thermal Degradation of High Molecular Components Obtained from Pyrolysis of Mixed Waste Plastics (혼합폐플라스틱의 열분해로부터 생성된 고분자성분의 열적분해)

  • Oh, Sea Cheon;Ryu, Jae Hun;Kwak, Hyun;Bae, Seong-Youl;Lee, Kyong-Hwan
    • Applied Chemistry for Engineering
    • /
    • v.19 no.2
    • /
    • pp.191-198
    • /
    • 2008
  • The thermal degradation characteristics of high molecular components obtained from pyrolysis of mixed waste plastics have been studied by thermogravimetric analysis (TGA) and gas chromatography spectrometry (GC-MS). The kinetics of thermal degradation has been studied by a conventional nonisothermal thermogravimetric technique at several heating rates between 10 and $50^{\circ}C/min$. The dynamic thermogravimetric analysis curve and its derivative have been analyzed using a variety of analytical methods reported in the literature to obtain information on the kinetic parameters such as activation energies and reaction orders. The yields of liquid products have been monitored by batch pyrolysis reactor under various reaction temperatures and reaction times. And the characteristic of liquid products with the increase in reaction temperature has been performed by GC-MS.

A Performance Measurement and Evaluation of a 400RT Vertical type Geothermal System installed in a Complex Building Before Occupancy (복합용도 건물에 적용된 400RT급 수직형 지열시스템의 입주전 성능평가)

  • Hwang, Kwang-Il;Shin, Dong-Keol;Kim, Joong-Hun;Shin, Seung-Ho;Jung, Myoung-Kwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.3
    • /
    • pp.7-14
    • /
    • 2008
  • 400RT geothermal system which is the biggest capacity among on-operations at present in Korea is measured and evaluated on 23rd${\sim}$26th Jan. 2008 during those days building is not allowed owners and/or tenants to move in. The geothermal system is consist with vertical-typed 112 geothermal heat exchangers which are installed circle-like 1 row with 4m interval, and has 16 units of 25USRT geothermal-source heat pump(GSHP)s. And each 5 units of circulation pump are running for geothermal heat exchangers and hot water supplies. The followings are the results. The temperatures at G.L. -70m of 2 boreholes are varied quite similarly. The average temperature difference between inlet and outlet of geothermal pipes is $4.1^{\circ}C$, and that of hot water supply is $3.2^{\circ}C$, of Zone 3's each 4 GSHPs when being operated. Despite temperature fluctuations by heating loads, the average temperature difference between main pipes of inlet and outlet of geothermal heat exchangers is measured as $4.1^{\circ}C$. This study propose "Geothermal System COP" which includes not only consumed electric power by compressor but also circulation pumps and auxiliary utilities. By comparing the geothermal system COP with GSHP's performance specification, it is clear that the performances of GHSPs of this site are satisfied with the specification.